protech ZOOM 450 ccpm User manual

Type
User manual
Vortex-flowmeter
VERSAFLOW VORTEX
Quick Start
VERSAFLOW VORTEX
34-VF-25-56 iss.1 GLO Sept 07 US 2
General safety notes
You can find the newest and/or additional information on the CD-ROM
provided, in the handbook, the datasheet, special manuals, certificates
and the download center at www.honeywell.com/ps.
Installation, mounting, commissioning, and maintenance can be
performed only by trained personnel.
Responsibility for suitability and intended use of this instrument rests
solely with the user.
The supplier accepts no liability for inappropriate use by the customer.
Improper installation and operation may lead to loss of warranty.
Moreover, the "general terms and conditions" on the back of the bill
apply, which form the basis for the sales contract.
If you have to send the device back to the manufacturer or supplier, fill
out the form contained on the CD-ROM and enclose it with the device.
Unless this form is completely filled out, it will unfortunately not be
possible for the manufacturer to perform repair or inspection.
Respect general and local electrical safety requirements.
VERSAFLOW VORTEX
www.honeywell.com/ps 3
Visual check
Check the consignment for damage.
Check the information on the nameplate against your order specifications.
Scope of delivery
1 Flowmeter in the version ordered
2 Quick Start directions
3 Certificates, calibration report and parameter datasheet
4 CD with complete documentation
5 Bar magnet
VERSAFLOW VORTEX
34-VF-25-56 iss.1 GLO Sept 07 US 4
Transportation
Permitted temperature ranges
1 Max. medium temperature see tech. datasheet
2 Max. storage temperature and ambient temperature
Ambient temp.: Ex devices -20...+65°C, non Ex devices -40...+85°C
Storage temperature: -50...+85°C
3 Protect device from direct exposure to sunlight
VERSAFLOW VORTEX
www.honeywell.com/ps 5
Preferred installation locations for the signal converter
Thermal insulation
1 Above a horizontal pipe
2 Below a horizontal pipe
3 On a vertical pipe
1 Max. height of insulation up to intermediate piece between measuring sensor and signal con-
verter
2 Max. thickness of the insulation up to the bend of the pressure pipe
3 Insulation
VERSAFLOW VORTEX
34-VF-25-56 iss.1 GLO Sept 07 US 6
Minimum inlet runs
1 General inlet run without disturbing flow 20 DN
2 Behind a control valve 50 DN
3 After a pipe diameter reduction 20 DN
VERSAFLOW VORTEX
www.honeywell.com/ps 7
1 After a single bend 90° 20 DN
2 After a double bend 2x90° 30 DN
3 After a double three-dimensional 2x90° bend 40 DN
VERSAFLOW VORTEX
34-VF-25-56 iss.1 GLO Sept 07 US 8
Minimum outlet runs
INFORMATION!
If a flow straightener 2 is installed, the required inlet run is
shortened.
1 Straight inlet run upstream of straightener 2 DN
2 Flow straightener
3 Straight pipe run between flow straightener and flowmeter 8 DN
4 Minimum straight outlet run 5 DN
1 Upstream of pipe expanders, pipe bends, control valves, etc. 5 DN
2 Upstream of metering points 5 6 DN
VERSAFLOW VORTEX
www.honeywell.com/ps 9
Piping with control valves
Vapor and gas measurement
1 Recommended: Installing the flowmeter upstream of the control valve, distance 5 DN
2 Not recommended: Installing the flowmeter directly downstream of control valves, due to vor-
tex formation.
CAUTION!
Prohibited: Installing the flowmeter in a lower pipe bend 1, risk of
condensate formation 2!
1 Lower pipe bends
2 Condensate
VERSAFLOW VORTEX
34-VF-25-56 iss.1 GLO Sept 07 US 10
Liquid measurement, prohibited installation locations
CAUTION!
Prohibited: Installing the flowmeter in an upper pipe bend 1, risk
of gas bubbles 2 forming!
CAUTION!
Prohibited: Installing the device in a downstream pipe 3 or
upstream pipe of a run-out 4.
There is the risk of a partially-filled pipe!
VERSAFLOW VORTEX
www.honeywell.com/ps 11
Liquid measurement, recommended installation locations
CAUTION!
It is absolutely necessary to maintain the required inlet and outlet
runs!
1 Recommended: If the flowmeter is installed in a downpipe, it is absolutely essential to install
a riser pipe immediately after it.
2 Recommended: Installing the flowmeter in an inclined riser pipe.
3 Recommended: Installing the flowmeter in a vertical riser pipe.
4 Recommended: Installing in the bottom pipe bend.
VERSAFLOW VORTEX
34-VF-25-56 iss.1 GLO Sept 07 US 12
General installation instructions
CAUTION!
Make sure that the connection flanges are sitting concentrically.
On metering points with varying thermal loads the flowmeters are
to be mounted with stress bolts (DIN 2509).
1 Installed length of flowmeter + thickness of gaskets.
VERSAFLOW VORTEX
www.honeywell.com/ps 13
CAUTION!
The inside diameters of the connection pipe flange, of the
flowmeter and of the gaskets must be the same! The gaskets
must not project into the pipe cross-section.
1 Internal diameter connection pipe
2 Internal diameter flange and gasket
3 Internal diameter measuring sensor
VERSAFLOW VORTEX
34-VF-25-56 iss.1 GLO Sept 07 US 14
Installing instruments in flange design
Install the flowmeter as follows:
Fix the flowmeter to one side of a flange using bolts and fixing nuts 2.
Insert the gaskets 1 between sensor and flange and align them.
Check that the gaskets are concentric; they must not project into the pipe.
Install the gasket, bolts and fixing nuts on the other flange side.
Align the meter and the gaskets so that they are concentric.
Now tighten all nuts step by step alternately across the diagonal.
VERSAFLOW VORTEX
www.honeywell.com/ps 15
Installing instruments in sandwich design
Install the flowmeter as follows:
Push the first bolt 3 through hole 5 of both flanges.
Screw on the nuts with washers at both ends of the bolt 3 but do not
tighten them.
Mount the second bolt through the holes 4.
Place the sensor 1 between the two flanges.
Insert the gaskets 6 between sensor 1 and flanges and align them.
Check that the flanges are sitting concentrically.
Install the remaining bolts, nuts and washers. But do not tighten the nuts
yet.
Turn the centering ring 2 anti-clockwise and align the flowmeter.
Check that the gaskets 6 are concentric; they must not extend into the
pipe.
Now tighten all nuts step by step alternately across the diagonal.
VERSAFLOW VORTEX
34-VF-25-56 iss.1 GLO Sept 07 US 16
Turning the connection housing
Turn the connection housing as follows
Switch off the power supply to the flowmeter.
Loosen the four Allen screws 1 on the underside of the converter
housing.
Lift the converter housing and turn it to the required position in 90° steps.
Screw the converter housing back on tightly.
DANGER!
All work on the flowmeter electrics may only be carried out by
appropriately trained personnel. The regional occupational health
and safety directives and safety regulations must be observed
without exception.
Do not damage the electrical cable by over tightening.
Do not undo the electrical plug connection.
1
VERSAFLOW VORTEX
www.honeywell.com/ps 17
Turning the LCD display
Turn the display as follows:
Switch off the power supply to the flowmeter.
Unscrew the cover in front of the display 1 from the converter housing.
Pull the display 2 carefully a few centimetres out of the anchor fitting and
turn it to the required position 3.
Press the display back onto the spacer pins 4, until it clicks firmly into
place.
Turn the cover with gasket 5 back onto the housing and tighten it by
hand.
INFORMATION!
If the flowmeter is installed in a vertical pipe, you have to turn the
display by 90
°
; if installed below a pipe, turn 180
°
.
123 4 5
VERSAFLOW VORTEX
34-VF-25-56 iss.1 GLO Sept 07 US 18
Protection category
Therefore it is essential to observe the following points:
Use only original gaskets that are clean and free of any damage. Defective
gaskets have to be replaced.
The electrical cables used must be undamaged and must comply with
regulations.
The cables must be laid with a loop 1 upstream of the flowmeter to
prevent water from getting into the housing.
The cable glands 2 have to be tightened firmly.
Align the meter in such a way that the cable gland is never pointing up 3.
Close the unused cable glands using blanking plugs 4.
DANGER!
The flowmeter meets the requirements of protection category IP
67.
After all servicing and maintenance work on the flowmeter, the
specified protection category has to be ensured again.
VERSAFLOW VORTEX
www.honeywell.com/ps 19
Electrical connections of the signal converter
The following procedures are to be performed:
Unscrew the housing cover 1 of the electrical terminal compartment.
Connect the device using the standard procedures.
Pay attention to the correct polarity.
Connect the grounding 7 or 8.
The two grounding points are equally effective from a technical point of
view.
Lubricate the thread of the cover periodically before closing it.
1 Housing cover of the electrical terminal compartment
2 Electrical connection terminals with the housing cover open
3 Terminal A Current output -
4 Terminal A+ Current output +
5 Terminal B Pulse output -
6 Terminal B+ Pulse output +
7 PE terminal in housing
8 PE terminal on connection piece between measuring sensor and signal converter.
VERSAFLOW VORTEX
34-VF-25-56 iss.1 GLO Sept 07 US 20
Electrical connection for current output
The maximum load resistance R
max
is calculated as follows:
1 Power supply
2 Optional amperemeter
3 Load
=R
max
22 mA
U
B
14V
-
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24

protech ZOOM 450 ccpm User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI