Alcatel-Lucent 1850 TSS-160 User manual

Category
Network switches
Type
User manual
Alcatel-Lucent 1850 TSS-160
TRANSPORT SERVICE SWITCH | RELEASE 3
The Alcatel-Lucent 1850 TSS-160 is a compact version of the Alcatel-Lucent TSS-320. The two models share
the universal switch matrix architecture, operate on a common software release and use common circuit
packs. The Alcatel-Lucent 1850 TSS-160 is a next-generation, Packet-Optical Transport platform that supports
any mix of traffic, from all-circuit to all-packet. With the Alcatel-Lucent 1850 TSS-160, businesses can begin
with circuit-based transport and gradually ramp up packet transport by simply changing line cards. The Alcatel-
Lucent 1850 TSS-160 supports current traffic requirements while eliminating the scalability issues encountered
when traditional multiservice provisioning platforms (MSPPs) are confronted with the high growth of packet-
based traffic.
The Alcatel-Lucent 1850 TSS-160 offers
the flexibility to split increasing traffic
demands among any combination of
Carrier Ethernet, Transport Multi-
Protocol Label Switching (T-MPLS),
wavelength division multiplexing
(WDM), optical data unit (ODU) and
SDH/SONET transport technologies. It
offers powerful cross-layer network
management and a unified control
plane, simplifying operations and
reducing the total cost of ownership.
Features
• Commonsoftwareandcircuitpacks
with Alcatel-Lucent 1850 TSS-320
• Unique,universalswitcharchitecture
¬ Switches packets or circuits in their
native format
¬ Accommodates any traffic mix,
from all-circuit to all-packet
¬ Offers TDM and packet line cards
for technology-specific processing
• Fullyintegratesphotonic,optical
and data layers
¬ Any transport-technology mix
¬ Carrier Ethernet service through
T-MPLS for standards-based con-
nection-oriented packet transport
¬ SONET/SDH Optical Transport
Hierarchy (OTH) switching, includ-
ing higher-order and lower-order
(HO/LO) synchronous transport
signal (STS) and VC-switching
¬ Very long haul (VLH)/ultra long
haul (ULH) support
¬ ATM pseudo-wire transport and
gateway functions
¬ Dense WDM (DWDM)
¬ Transport-oriented OAM and
G-MPLS
Alcatel-Lucent 1850 TSS-160 | Release 3 | Data Sheet2
Technical specifications
Alcatel-Lucent 1850 TSS-160
system
Alcatel-Lucent 1850 TSS-160
subrack
• 8slots,20Gb/sperslot:16half
slots,10Gb/sperhalfslot
• Two160Gb/sprotectedswitching
fabrics
• Twoprotectedcontrollers
• Protectedpowersupply
• Uptothreesubracksinastandard
ETSI or ANSI rack
Interfaces
• Datacards
¬10xGigabitEthernet(GE)
packet module, Small Form-
Factor Pluggable (SFP)
¬10GEpacketmodule,10Gb/s
Form-Factor Pluggable (XFP)
¬ Multiservice packet over
SONET/SDH(PoS)packet
module, portless
¬ ATM gateway packet module,
portless
• SONET/SDHcards
¬1xOC-192/STM-64:XFP
¬4xOC-48/STM-16:SFP
¬8xOC-3-12/STM-1-4:SFP
¬10xanyportcard:adata/TDM
concentrator:SFP
¬ 1 x optical transport unit
(OTU)-2:10Gb/sbidirectional
transponder, tunable optics
• VLH/ULHcards
¬10Gb/sbooster+10dBm
¬10Gb/spre-amp+10dBm
• FixedOADM(FOADM)DWDM
cards (packs)
¬8channelsMUX/DEMUX,
L1 band
¬8channelsMUX/DEMUX,
L2 band
¬Opticalamplifier22/917dB
¬10Gtransponder,clientand
linepluggable:XFP
• ROADMDWDMcards(packs)
¬ Optical protection switch
¬ DWDM ROADM wavelength
router
¬DWDMtransponder:tunable
line optics, XFP client
¬DWDMMUX/DEMUX
¬ DWDM amplifier
• Deliversmultidegreerecongu-
rable optical add/drop multiplexer
(ROADM) functionality
¬ Reconfigurable 44 x 10 G channel
DWDM
¬ Wavelength selective switch (WSS)
1 x 9 ports
¬ Mesh capable ROADM up to
8 degrees
Benefits
• Switchesanycombinationofpackets
and circuits in their native formats
using a single platform
• Fullyscalespackettransport,smoothly
progressing from all-circuit to all-
packet, allowing service providers
to transform networks to packet
transport
• Efcientlyaggregatesandgrooms
metro and long-haul transport
• Simpliesnetworkplanningusing
ROADM and WDM
• Reducestotalcostofownershipand
simplifies operations through cross-
layer network management and
unified control plane
• Supportsabroadrangeofapplica-
tions, such as triple play services,
business Ethernet and mobility
backhaul
Service level agreement (SLA)
management
• Trafficprofiles
¬Bandwidthguaranteed
¬Regulated:minimumband-
width guaranteed plus burst
¬Besteffort
•Hitlesstraffic-profilemodification
• Metering
¬SingleRateTokenBucket:
RFC2697
¬DualRateTokenBucket:
RFC 2698
¬ IETF and Metro Ethernet Forum
(MEF) Metering, Policing and
Marking
¬ Color-blind and color-aware,
based on Ethernet priority bits
Ethernet functionality
• Ethernetprotocol:802.3
• EthernetMediaAccessControl
(MAC) autolearning and aging
• Ethernet-MACstaticconfiguration
• AccessControlList(ACL)
• VirtualLAN(VLAN)push,pop,
swap:servicedelimiting
• Ethernetvirtualbridging:802.1Q
• Ethernetproviderbridging:802.1ad
• QinQ
• RapidSpanningTreeProtocol
(RSTP) and Multiple Spanning
Tree Protocol (MSTP)
• Linkaggregation
• Jumbo-framemanagement
• Y.1731/802.1agOAM:continuity
check (CC), link trace (LT),
loopback(LB)
• 802.3ahOAM:Ethernetinthe
first mile (EFM)
• EightQualityofService(QoS)
classes
• TwolevelsQoS:perclass,per
transport service
• Ethernetflow,RGYcounters
• L2controlprotocolfiltering/
tunneling
• MetroEthernetForum(MEF)9
andMEF14certified:EPL,EVPL
and E-LAN
Ethernet traffic classification
• Port
• EthernetVLAN
• Ethernetprioritybits
• IPv4differentiatedservices
code points (DSCP)
•EtherType
• MPLSExpbits
Alcatel-Lucent 1850 TSS-160 | Release 3 | Data Sheet 3
Ethernet forwarding criteria
• Port
• PortplusMAC
• PortplusVLAN
• PortplusMACplusVLAN
• PortplusMACplusVLANplus
Prio bits
• Unicasttraffic
• Multicasttraffic
• Broadcasttraffic
IGMP functionality
• InternetGroupManagement
Protocol(IGMP)snooping
• IGMPproxy
• IGMPfastleave
ATM functionality
• Pseudo-wireemulationedgeto
edge(PWE3):ATM-PWE3gateway
• OC-3/STM-1ATMunchannalized
• ATMvirtualpathidentifier/virtual
channelidentifier(VPI/VCI)
N:1mappingwithPWE3static
configuration
• ATMQoS,OAMF4,F5:PWEOAM
T-MPLS functionality
• Dataplane:T-MPLS,MPLS
• T-MPLSOAM:CV,automaticpro-
tection switching (APS), forward
defect indication (FDI)
• TunnelLinProtection1:1
• Ethernetline(E-line),E-LAN
and E-Tree
SONET/SDH functionality
• Cross-connection
• Termination
• EthernetmappingoverSONET/SDH
¬Genericframingprocedure:
GFP,G.7041
• Virtualconcatenation(VCAT)
• Linkcapacityadjustmentscheme
(LCAS)
•Performancemonitoring
• HOandLOcapabilities
DWDM functionality
• Nodeconfigurations
¬ Terminal
¬ In-line amplifier (ILA)
•Networkconfigurations
¬ Point-to-point
¬ Linear
¬ Ring
¬ Mesh
Protection
• Ethernetnetworkprotection
¬RSTP:802.1w
¬MSTP:802.1s
¬ Link aggregation
• T-MPLSnetworkprotection
¬TunnelLinProtection1:1
•SONET/SDHnetworkprotection
¬Single-anddual-endedAPS1+1
¬ Subnetwork Connection
Protocol (SNCP), unidirectional
path-switchedring(UPSR)
¬ Multiplex Section-Protection
Ring(MSPRING)2Fbidirectional
lineswitchingring(BLSR)
•Equipmentprotection
¬ Power protection
¬ Controller protection
¬Universalswitchprotection
G-MPLS control plane
• T-MPLStunnelsetup
• TDMHOpathsetup
Management
• Alcatel-Lucent1350Optical
Management System (OMS)
TL1
• Zero-installationcraft(ZIC)terminal
• Commandlineinterface(CLI)
• SimpleNetworkManagement
Protocol (SNMP)
• SecureShell(SSH)v2/Secure
Sockets Layer (SSL) for secure
connection
Physical specifications
ANSI
Dimensions: Alcatel-Lucent 1850
TSS-160 subrack
• Subrackdimensions
¬Height:304mm(12.0in.)
¬Width:498mm(19.6in.)
¬Depth:305mm(12.0in.)
or 356 mm (14.0 in.)
• Designedtobeinstalledina
standard ANSI rack
¬Height:2.13m(7.0ft.)
¬Width:660mm(26.0in.)
¬Depth:305mm(12.0in.)
or 356 mm (14.0 in.)
Power and cooling
• Powersupply:DCfeed(-48-VDC
nominal)
• Powersupply:-58-V
• Powerconsumption:upto2000W
• Cooling:forcedair
Environment
• Operatingtemperature:
-5°Cto+45°C(23°Fto113°F)
• Relativehumidity:0%to90%,
non-condensed
Regulatory compliance
• CEandULcertification
• NEBSlevel3
• FCCpart15classA
ETSI
Dimensions: Alcatel-Lucent 1850
TSS-160 subrack
• Subrackdimensions
¬Height:304mm(12.0in.)
¬Width:498mm(19.6in.)
¬Depth:290mm(11.4in.)
• Designedtobeinstalledina
standard ETSI rack
¬Height:2.20m(7.2ft.)
¬Width:600mm(23.6in.)
¬Depth:300mm(11.8in.)
Power and cooling
• Powersupply:DCfeed(-48-VDC
nominal)
• Powersupply:-65-V
• Powerconsumption:upto2000W
• Cooling:forcedair
Environment
• Operatingtemperature:
-5°Cto+45°C(23°Fto113°F)
• Relativehumidity:0%to90%,
non-condensed
Regulatory compliance
•CEcertification
• Operatingconditions:
ETS 300 019, Class 3.2
•Storageconditions:
ETS 300 019, Class 1.2
•Transportationconditions:
ETS 300 019, Class 2.2
• Electrostaticdischarge(ESD)/elec-
tromagneticcompatibility(EMC):
ETS 300 386 “Telecommunications
Center”
www.alcatel-lucent.com Alcatel, Lucent, Alcatel-Lucent and the Alcatel-Lucent logo
are trademarks of Alcatel-Lucent. All other trademarks are the property of their respective owners.
The information presented is subject to change without notice. Alcatel-Lucent assumes no responsibility
for inaccuracies contained herein. Copyright © 2008 Alcatel-Lucent. All rights reserved.