Beurer BC 87 User manual

Type
User manual
ENGLISH
Wrist Blood Pressure Monitor
Instructions for use ................ 3
ESPAÑOL
Tensiómetro para muñeca
Manual de instrucciones ...... 28
SERIES 800W
Distributed by/Distribuido por :
Beurer North America LP
1 Oakwood Boulevard, Suite 255
Hollywood, FL 33020, USA
www.beurer.com
Questions or comments?
Call our US-based customer service toll free at 1-800-536-0366.
¿Preguntas o comentarios? Llame a nuestro servicio al cliente en
Estados Unidos gratis al teléfono 1-800-536-0366.
READ THIS MANUAL COMPLETELY AND CAREFULLY
BEFORE USING THIS PRODUCT
Keep this manual in a safe location for future reference
LEA TODO ESTE MANUAL CON ATENCIÓN ANTES
DE USAR ESTE PRODUCTO
Conserve este manual en un lugar seguro para consultarlo en el futuro
3
SAVE THESE INSTRUCTIONS FOR FUTURE
REFERENCE
If the instruction manual is damaged or if you
no longer have the instruction manual in your
possession, please contact customer service.
See warranty for service contact.
Dear Valued Customer,
Thank you for choosing one of our products. Our name
stands for high-quality, thoroughly tested products for
application in the areas of heating, weight management,
blood pressure, body temperature, pulse, gentle therapy,
massage, and beauty.
Register your product today to receive further benefits:
added protection for your purchase
health and wellness tips
new product information
continual outstanding customer service and support.
Visit www.registerbeurer.com or contact customer service at
1-800-536-0366.
Please read these instructions for use carefully and keep
them for later use. Make them accessible to other users and
observe the information they contain.
With kind regards,
Your Beurer team
ENGLISH
Contents
1. IMPORTANT SAFETY NOTES .............................4
2. Getting to Know your Instrument ........................8
3. Package Contents ...............................................8
4. Parts and Controls ...............................................9
5. Preparing for Measurement ...............................10
6. Measuring Blood Pressure ................................12
7. Evaluating Results .............................................15
8. Displaying and Deleting Measurements ............17
9. Care, Maintenance and Disposal ......................18
10. Troubleshooting Guide ....................................18
11. Technical Specifications ..................................19
12. FCC Compliance Information ..........................20
13. Warranty ..........................................................21
4
1. IMPORTANT SAFETY NOTES
Signs and symbols
Whenever used, the following signs identify safety and
property damage messages and designate a level of hazard
or seriousness.
READ THIS ENTIRE MANUAL, THE SAFETY SECTION
AND ALL INSTRUCTIONS AND WARNINGS COMPLETELY
AND CAREFULLY BEFORE USING THIS PRODUCT.
FOLLOW ALL SAFETY INSTRUCTIONS AND WARNINGS
TO AVOID HAZARDOUS SITUATIONS AND TO MAKE
CORRECT USE OF THIS PRODUCT.
This is the safety alert symbol. It alerts
you to potential personal injury hazards.
Obey all safety messages that follow this
symbol to avoid possible injury or death.
WARNING
Indicates a hazardous situation which,
if not avoided, could result in death or
serious injury.
CAUTION
Indicates a hazardous situation which,
if not avoided, may result in minor or
moderate injury
NOTICE
Addresses practices not related to
personal injury, such as product and/or
property damage.
Isolation of applied parts Type BF
Galvanically isolated applied part
(F stands for “floating”); meets the
requirements for leakage currents for
type B
Observe the instructions
Read the instructions before starting work
and/or operating devices or machines
Direct current
The device is suitable for use with direct
current only
Storage/Transport Permissible storage and transport
temperature and humidity
Operating
Permissible operating temperature and
humidity
Serial number
5
IP 22
Device protected against foreign objects
≥ 12.5 mm and against water dripping at
an angle
WARNING – To reduce the risk of fire,
electric shock, or serious personal
injury:
Do not use the blood pressure monitor on newborns or
patients with pre-eclampsia. Consult your doctor before
using the blood pressure monitor during pregnancy.
This device is not intended for use by people
(including children) with restricted physical, sensory
or mental skills or a lack of experience and/or a lack
of knowledge, unless they are supervised by a person
who has responsibility for their safety or they receive
instructions from this person on how to use the device.
Supervise children around the device to ensure they do
not play with it.
Small parts may present a choking hazard for small
children if swallowed. They should therefore always be
supervised.
Cardiovascular diseases may lead to incorrect
measurement accuracy. The same also applies to very
low blood pressure, diabetes, circulatory disorders, and
arrhythmias as well as chills or shaking.
The blood pressure monitor must not be used in
connection with a high-frequency surgical unit.
• D
mastectomy.
• D
further injury.
• M
which the arteries or veins are undergoing medical
treatment, e.g. intravascular access or intravascular or
therapy, or an arteriovenous (AV) shunt.
Do not use the device at the same time as other
medical electrical devices (ME equipment). This could
lead to a malfunction of the device and/or an inaccurate
measurement.
During the blood pressure measurement, the blood
circulation must not be stopped for an unnecessarily
from the wrist.
The device is not suitable for use on the women who
are or may be pregnant.
The device is not suitable for use on patients with
implanted, electrical devices, such as cardiac
pacemakers, defibrillators.
6
CAUTION – To reduce the risk of
personal injury or product/ property
damage:
• P
on other parts of the body.
Please note that when inflating, the functions of the
limb in question may be impaired.
Do not perform measurements more frequently than
necessary. The resulting restriction of the blood flow
may cause injury.
NOTICE:
We recommend that the batteries be removed if the
device is not to be used for a prolonged period.
Do not use the device outside of the specified storage
and operating conditions. This could lead to incorrect
measurements.
The device is only intended for the purpose described
in these instructions for use. The manufacturer is not
liable for damage resulting from improper or careless
use.
Using the blood pressure monitor outside your home
environment or whilst on the move (e.g. whilst travelling
in a car, ambulance or helicopter, or whilst undertaking
physical activity such as playing sport) can influence
the measurement accuracy and cause incorrect
measurements.
• O
values will be recorded.
Protect the device from impacts, humidity, dirt, marked
temperature fluctuations and direct sunlight.
Do not drop the device.
Do not use the device in the vicinity of strong
electromagnetic fields and keep it away from radio
systems or mobile telephones.
Never immerse or spill water or any other liquid onto
the monitor or any components, otherwise liquid will
enter it and cause damage.
Never attempt to repair, open and/or disassemble the
adjust it yourself. This may damage the unit and impair
the functions. If you need to have the unit repaired,
please contact our customer service. Please see
warranty for service contact. Before submitting any
complaint, first check the batteries and replace them if
necessary.
Bring the device to room temperature before taking
measurements. If the measuring device has been
stored near to the maximum or minimum storage
7
and transport temperature and is brought into an
environment with a temperature of 68 °F (20 °C), it is
recommended that you wait 2 hours before using the
measuring device.
Battery Handling Safety Precautions
Use only the size and type of batteries specified.
Be sure to follow the correct polarity when installing
the batteries. Reversed batteries may cause damage to
the device.
• D
Alkaline and Carbon-zinc or rechargeable batteries) or
old batteries with fresh ones. Always replace batteries
as a simultaneous set.
If the batteries in the device are depleted or the device
will not be used for a long period of time, remove the
batteries to prevent damage or injury from possible
battery leakage.
Do not try to recharge batteries not intended to be
recharged; they can overheat and rupture (follow
battery manufacturer’s directions).
Do not dispose of batteries in fire, batteries may
explode or leak.
Clean the battery contacts and also those of the device
prior to battery installation.
Remove discharged batteries from the product and
dispose/recycle in compliance with all applicable laws.
Keep batteries away from children and pets. Batteries
may be harmful if swallowed. Should a child or
pet swallow a battery, seek medical assistance
immediately.
If your skin or eyes come into contact with battery fluid,
assistance.
Do not disassemble, open or crush the batteries.
If a battery has leaked, put on protective gloves and
clean the battery compartment with a dry cloth.
Notes on electromagnetic compatibility
The device is suitable for use in all environments
listed in these instructions for use, including domestic
environments.
The use of the device may be limited in the presence
of electromagnetic disturbances. This could result in
issues such as error messages or the failure of the
display/device.
Avoid using this device directly next to other devices
or stacked on top of other devices, as this could lead
to faulty operation. If, however, it is necessary to use
the device in the manner stated, this device as well as
8
the other devices must be monitored to ensure they are
working properly.
The use of accessories other than those specified or
provided by the manufacturer of this device can lead to
an increase in electromagnetic emissions or a decrease
in the device’s electromagnetic immunity; this can
result in faulty operation.
Failure to comply with the above can impair the
performance of the device.
2. GETTING TO KNOW YOUR
INSTRUMENT
This blood pressure monitor performs non-invasive
measurement and monitoring of adult arterial blood pressure
and heart rate on adult patients with wrist circumference
from 5.3 to 8.5 in. You can use it to measure your blood
pressure quickly and easily, store the results, and display
stored readings and their average. This device comes with
a resting indicator which shows if the user’s circulatory
It also features an irregular heartbeat indicator, with values
classified and graphically evaluated according to industry
guidelines. The recorded data can provide healthcare service
providers with support during the diagnosis and treatment
of blood pressure problems, and therefore plays a part in
the long-term monitoring of the users health. The Blood
Pressure Monitor is intended for use indoors and by adults
only. For consistency, always measure your blood pressure
at the same time each day. Before each measurement,
relax for about five minutes. When performing multiple
measurements on an individual, wait five minutes between
each measurement. Do not take a measurement within 30
minutes of eating, drinking, smoking or exercising. Repeat the
measurement if you are unsure of the results. Measurements
are for your information only – they are no substitute for a
medical examination. Discuss the measurements with your
doctor and never base any medical decisions on them (e.g.
medicines and their administration).
3. PACKAGE CONTENTS
1 x Storage Box
2 x 1.5 V AAA batteries
1 x Quick Start Guide
1 x Instruction manual
9
4. PARTS AND CONTROLS
M1
M2
OK
2
1
3
4
5
6
7
1. Blood Pressure Risk Indicator
2. LCD Display
3. M1 Memory Button
4. START/STOP Button with position indicator
5. M2 Memory Button
6. Battery Compartment
7.
LCD Display Information
SYS
mmHg kPa
DIA
mmHg kPa
PUL
/min
1 2
3
4
5
6
789
10
11
1. Time and Date
2. Low Battery Icon
3. Bluetooth
®
Icon
4. Resting Indicator
5. User Number /
6. Memory Space Number/
Average ( )/Morning
Reading ( )/Evening
Reading ( )
7. Pulse Rate
8. Irregular Heartbeat /
Pulse Icons
9. Risk Indicator
10. Diastolic Pressure
11. Systolic Pressure
10
5. PREPARING FOR
MEASUREMENT
Inserting/changing batteries:
1. Push the tab on the middle of the Battery Compartment
Cover to remove it from the bottom of the device.
2. Insert two AAA alkaline batteries (included) according to
the polarity markings inside the compartment.
NOTE: Do not use rechargeable batteries.
3. Reattach the Battery Compartment Cover.
4. " " will flash. Set the hour format, date and time as
described below. Any saved measurements will be
retained.
1 2 3
Setting the hour format, date, time, Bluetooth
connectivity, and default user number:
If date and time are not set, stored measurements will not
have a valid timestamp associated with them.
NOTE: Press and hold the M1 or M2 Buttons to advance
values rapidly.
Before first use and after every battery
change:
When you insert batteries into the device, you will
automatically arrive at the relevant menu.
If batteries have already been inserted:
START/
STOP Button for 5 seconds.
1. Select an hour format (12 or 24 hour
display) with the M1/M2 Buttons and
press the START/STOP Button to confirm.
2. The year flashes on the LCD Display. Set
the year with the M1/M2 Buttons and
press the START/STOP Button to
confirm. .
3. The month flashes on the LCD Display. Set
the month with the M1/M2 Buttons and
press the START/STOP Button to confirm.
4. The day flashes on the LCD Display. Set the
day with the M1/M2 Buttons and press the
START/STOP Button to confirm.
11
NOTE: If the hour format is set to , the day/month
display sequence is reversed.
5. The hour flashes on the LCD Display. Set the
hour with the M1/M2 Buttons and press the
START/STOP Button to confirm.
6. The minutes flash on the LCD Display. Set the minutes
with the M1/M2 Buttons and press the START/STOP
Button to confirm.
7.
The Bluetooth icon flashes on the LCD Display. Use the
M1/M2 Buttons to select (Bluetooth icon appears in the
LCD Display) or deselect (Bluetooth icon disappears from
the LCD Display) automatic Bluetooth data transfer. Note
that Bluetooth transfers may impact battery life. See the
“Bluetooth Setup” subsection below for details. Press the
START/STOP Button to confirm.
8.
The User Number icon flashes on the LCD Display. Select
a User Number (U1 or U2) with the M1/M2 Buttons and
then press the START/STOP Button to confirm and exit.
Measurement will start after settings.
Bluetooth
®
Setup
In addition to displaying and saving measurements locally
on the blood pressure monitor itself, you can also transfer
measurements to your mobile device via Bluetooth®. To do
so, you will need to install the “Beurer HealthManager Pro”
app. These apps are freely available in either the Apple App
Store or Google Play Store.
System requirements:
iOS ≥ 14.0, Android ≥ 8.0
• Bluetooth® ≥ 4.0
For a list of compatible devices, scan the QR Code below:
To transfer the measured values, proceed as follows:
Start the app and follow the instructions.
Select your blood pressure monitor in the app.
Confirm the pairing request on your smartphone.
Take a measurement
• If the Bluetooth® function is activated, data will be
automatically transferred after the measurement.
(Data transfer at a later point): Go into the memory
recall mode for the desired user memory (see “Saving,
accessing and deleting measured values”). The data
transfer starts automatically.
12
Make sure the Beurer mobile app on your smartphone
is always activated and open before you start data
transfer from the blood pressure monitor.
Data transfer is in progress when the Bluetooth
®
symbol appears on the LCD Display.
6. MEASURING BLOOD
PRESSURE
The blood pressure monitor needs to be at room
temperature when measuring. Fundamentally, blood
pressure can be measured on both wrists. Blood pressure
can vary between the right and left arm, which may mean
Always perform the measurement on the same arm. If the
consult your doctor to determine which arm should be
used for the measurement.
1 2 3
0.4-0.6 in
M1
M2
O
k
M1
M2
O
k
M1
M2
O
k
1.
2. Position device about half an inch (1 cm) below the
bottom of your hand.
3.
Correct Posture:
1. Rest for at least five minutes before each
measurement.
2. Perform the measurement sitting
upright with your arms and back
supported and comfortably.
Place your feet flat on the floor,
do not cross your legs.
• • • • • • • • • • • • •
13
3.
heart.
4. Keep still during the measurement and do not talk.
Positioning indicator
This device has a positioning indicator below the START/
STOP Button to help determine the correct measuring
position of the device at heart level. It changes color
depending on the angle of observation.
Position indicator appears red
- Incorrect wrist position; wrist
is either too high or too low.
M1
Position indicator appears green
and "OK" shows in the indicator
window
- Correct wrist position; start
measurement using the
START/STOP Button.
M1
OK
In the vast majority of use cases, the position indicator
provides an excellent guide as to whether the measuring
as size and/ or physique on the user side, this function
may not be helpful in all cases. If you feel that the wrist
position according to the position indicator does not
match the level of the heart, use your own judgement.
User Number Selection
This device has two user memories with 120 memory
spaces each so you can save measurements from two
the device, make sure to set the appropriate user number
before measurement. See the "Setting the hour format,
date, time, Bluetooth connectivity, and default user
number" section for instructions on selecting a desired
User Number. The user can also be chosen by pressing
the M1/M2
Performing a Measurement
1.
press the START/STOP Button. All LCD Display
elements will briefly display, before HI appears on the
display and measurement will begin after about three
seconds. To cancel a measurement at any time, press
the START/STOP Button.
14
2.
will release. The pulse symbol ( ) will display, along
with systolic and diastolic pressure.
3.
An icon will appear in the LCD Display to indicate
whether you were suciently rested during the
measurement ( = Rested, = Not rested). See
the „Resting Indicator“ subsection below for details.
4.
Er_ (where the blank space
is a number 1-8) will appear
if the measurement was not
performed properly. Refer to the
Troubleshooting Guide“ section
for details about specific error
message numbers and then
repeat the measurement.
5. To select a desired user memory, press the M1 or M2
Button. Each of the two user memories can store 120
sets of measurements. If you do not select a user
memory, the measurement will be stored in the most
recently-used user memory.
6.
If Bluetooth® data transfer is active, the unit will transmit
measurement data to the "beurer HealthManager
Pro" mobile app installed on your paired mobile
device. The Bluetooth
®
icon will flash while the unit
establishes communication with your mobile device
and will display when a link is successful. After data
unsuccessful, the error message " " will display.
Also, if the unit cannot establish a Bluetooth
®
NOTE: Remember that you must add the SERIES 800W
blood pressure monitor to the "beurer HealthManager
Pro" app to enable data transfer.
7.
Press the START/STOP
pressure monitor if needed. The measurement is stored
in the selected user memory. The device will also shut
8.
Wait at least five minutes before taking another
measurement.
15
7. EVALUATING RESULTS
Irregular Heartbeat:
This device can detect irregular heartbeat patterns during
measurement and will indicate them by displaying the
Irregular Heartbeat Icon . This could be an indicator for
.lamronba si mhtyhr traeh eht erehw noitidnoc a ,aimhtyhrra
These symptoms (omitted or premature heartbeats, slow or
excessively fast heart rate) may be caused, among other
things, by heart disease, age, physical predisposition,
excessive use of stimulants, stress, or lack of sleep. This
function is not designed for diagnosing or treating an
arrhythmic disorder. Only your doctor can determine if you
do have arrhythmia.
Repeat the measurement if the Irregular Heartbeat Icon
displays after a measurement. Rest for at least five minutes
between measurements and do not talk or move during
measurement. If the icon appears often, contact your
doctor, since self-diagnosis and treatment based solely on
the test results may be dangerous. It is vital to follow your
doctor‘s instructions.
Risk Classification
Measurements can be classified and assessed by the table
below. However, these standard values are only a general
Hypertension
Category
Systolic
(in mmHg)
Diastolic
(in mmHg) Action
Color for
the risk
indcator
Grade 3:
Severe
hypertension
≥ 180 ≥ 110
Seek
medical
advice
Red
Grade 2:
Moderate
hypertension
160 – 179 100 – 109
Seek
medical
advice
Orange
Grade 1: Mild
hypertension 140 – 159 90 – 99
Have your
doctor
check
your blood
pressure
regularly
Yellow
High Normal 130 – 139 85 – 89
Have your
doctor
check
your blood
pressure
regularly
Green
Normal 120 – 129 80 – 84
Continue
self-
monitoring
Green
16
Hypertension
Category
Systolic
(in mmHg)
Diastolic
(in mmHg) Action
Color for
the risk
indcator
Optimal < 120 < 80
Continue
self-
monitoring
Green
Source: WHO, 1999
Consult your doctor regularly for advice. Your doctor will tell
you your individual values for normal blood pressure as well
as the value above which your blood pressure is classified
as dangerous.
The classification on the LCD Display shows where the
recorded blood pressure values fall. If the systolic and
Classification Indicator shows the higher category.
Resting Indicator
A common error made when taking a blood pressure
measurement is not ensuring the users circulatory system
and diastolic blood pressure values do not correspond to
proper blood pressure levels. This blood pressure monitor
uses integrated haemodynamic stability diagnostics (HSD)
to indicate whether the blood pressure was taken when the
Measured blood pressure value was obtained
when the users circulatory system was
the blood pressure at rest.
Indicates that the value was obtained when the
rested. The blood pressure values measured in
this case generally do not correspond to the
blood pressure at rest. Wait five minutes and
remeasure.
No resting
indicator
symbol
displayed
During the measurement it was not possible
to determine whether the users circulatory
minutes and remeasure.
this can be caused by various factors such as physical
or mental strain or distraction, speaking, or experiencing
irregular heartbeat during the measurement.
In an overwhelming number of cases, HSD will give a very
good guide as to whether the user’s circulatory system is
rested when taking a blood pressure measurement.
or chronic mental conditions may remain haemodynamically
unstable even in the long-term, something which persists
even after repeated periods of rest. The accuracy of the
17
results for the blood pressure at rest is reduced in these
users. Like any medical measurement method, the precision
of HSD is limited and can lead to incorrect results in some
cases. Nevertheless, the blood pressure measurements
represent particularly reliable results.
8. DISPLAYING AND DELETING
MEASUREMENTS
User Memory:
Every successful measurement is stored along with its date
and time. If there are more than 120 measurements in a user
memory bank, the oldest measurement is deleted.
M1 (for user 1) or M2 (for
user 2) Button to select a user memory. Confirm selection by
pressing the START/STOP button.
Average Values:
1.
"" is shown on the display. The
average of all saved measurements
in the selected user memory is
displayed. If Bluetooth® is activated
(the symbol flashes on the display),
the blood pressure monitor attempts
to connect to the app. If you press
the M1 Button in the meantime, the
transfer is cancelled and the average
values of the morning are displayed.
SYS
mmHg
DIA
mmHg
PUL
/min
2.
Press the relevant Memory Button
again; " " is shown on the display.
The average value of the morning
measurements for the last seven
days is displayed (morning: 5:00 AM
- 9:00 AM).
SYS
mmHg
DIA
mmHg
PUL
/min
3.
Press the Memory Button a third
time; " " is shown on the display.
The average value of the evening
measurements for the last seven
days is displayed (evening: 6:00 PM
- 8:00 PM).
SYS
mmHg
DIA
mmHg
PUL
/min
18
Individual Measured Values:
1.
Press the M1 Button again and the last individual
measurement is displayed. Press the M1 Button once
more to view all previous measurements.
2. START/STOP Button.
You can exit the menu at any time by pressing the START/
STOP Button.
Clearing Memory:
1.
To clear one of the user memories, you must first select it.
2.
Start individual measurement access as described above
and select a user memory.
3.
Press and hold the M1 and M2 Buttons for
five seconds. CL01 appears on the LCD
Display and all values in the selected user
memory will be deleted.
NOTE: To exit the menu at any time, press the START/STOP
Button.
9. CARE, MAINTENANCE AND
DISPOSAL
• C
cloth.
Do not use detergents or solvents.
Never immerse the device in water or other liquids.
When storing the device, make sure no heavy objects
are placed on top of it. Remove the batteries. Ensure
the Air Tube does not have any sharp kinks.
Disposal
Observe the local regulations for material disposal. Dispose
of the device in accordance with local regulations. If you
have any questions, please contact the local authorities
responsible for waste disposal.
10. TROUBLESHOOTING GUIDE
In case of errors, " " will appear in the LCD Display, where
” is a number 1-8. Error messages may appear if:
Error
Message
Possible cause Solution
Pressure or pulse
could not be
measured
Please wait one
minute and repeat the
measurement. Ensure
that you do not talk
or move during the
measurement
19
Movement or
speech during
measurement
Please wait five minutes
and then repeat the
measurement.
attached correctly
Remove and
before repeating the
measurement
An unknown error
occurred during
measurement
Please wait five
minutes and repeat the
measurement. Ensure
that you do not talk
or move during the
measurement
Er5
inflate properly
or readings
are outside
measurement
range
Remove and
before repeating the
measurement
Batteries are
almost depleted
Replace the batteries
Data not
transferred via
Bluetooth
®
Please refer to
the instructions in
"Bluetooth
®
Setup"
subsection in the
"Preparing for
Measurement" section.
Other device error Please wait five minutes
and then repeat the
measurement.
11. TECHNICAL SPECIFICATIONS
Model BC 87
Type BC 87W
Measurement
Method
Oscillometric, non-invasive blood
pressure measurement on the
upper arm
Measurement
Range Systolic 60-230 mmHg,
Diastolic 40-130 mmHg,
Pulse 40-199 beats/minute
20
Display Accuracy Pressure ± 3 mmHg,
Pulse ± 5%
Measurement
inaccuracy
Max. permissible standard
deviation according to clinical
testing: systolic 8 mmHg /
diastolic 8 mmHg
Memory 2 x 120 memory spaces
Dimensions 2.8 in L x 3.8 in W x 2.8 in H
(72 mm L x 96 mm W x 71 mm H)
Weight
batteries
5.3 in - 8.5 in (135 - 215 mm)
Operating Range 41° F - 104° F (5° C - 40° C),
15-90% relative humidity
(non-condensing)
Storage Range -4° F - 140° F (-20° C - 60° C),
≤93% relative humidity
(non-condensing)
Power Supply 2 x 1,5 V AAA batteries
Battery Life Approx. 300 measurements
12. FCC COMPLIANCE
INFORMATION
Upper Arm Blood Pressure Monitor SERIES 800W
Responsible Party – U.S. Contact InformationBeurer North
America LP
1 Oakwood Boulevard, Suite 255
Hollywood, FL 33020
United States
1-800-536-0366
info@beurer.com
FCC Compliance Statement
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and (2)
this device must accept any interference received,
including interference that may cause undesired operation.
Changes or modifications not expressly approved by the
party responsible for compliance could void the user’s
authority to operate the equipment.
NOTE: This equipment has been tested and found to
comply with the limits for a Class B digital device, pursuant
FCC Radiation Exposure Statement
This equipment complies with FCC radiation exposure
limits set forth for an uncontrolled environment.
This transmitter must not be co-located or operating in
conjunction with any other antenna or transmitter.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52

Beurer BC 87 User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI

in other languages