Tempo Communications OFL100 OTDR User manual

Type
User manual

Tempo Communications OFL100 OTDR is an Optical Time Domain Reflectometer used to measure the length and individual loss events on a single-mode fiber optic link. This handheld OTDR features an intuitive interface and powerful functions, making it an ideal tool for fiber optic testing and troubleshooting. With its high dynamic range and resolution, the OFL100 can accurately locate and characterize faults, breaks, and other impairments in fiber optic cables.

Tempo Communications OFL100 OTDR is an Optical Time Domain Reflectometer used to measure the length and individual loss events on a single-mode fiber optic link. This handheld OTDR features an intuitive interface and powerful functions, making it an ideal tool for fiber optic testing and troubleshooting. With its high dynamic range and resolution, the OFL100 can accurately locate and characterize faults, breaks, and other impairments in fiber optic cables.

Tempo Communications Inc. 1390 Aspen Way • Vista, CA 92081 USA • 800-642-2155
OFL100 OTDR
INSTRUCTION MANUAL
Read and understand all of the instructions
and safety information in this manual
before operating or servicing this tool.
Register this product at www.TempoCom.com
SET ESC
ON
CHARGE
OFL100
Tempo Communications Inc. 1390 Aspen Way • Vista, CA 92081 USA • 800-642-2155
2
Table of Contents
Preface 3
Description ............................................................................................................................................................ 3
Safety ....................................................................................................................................................................... 3
Purpose of This Manual ................................................................................................................................. 3
Warranty ................................................................................................................................................................. 3
Important Safety Information 4
Section 1. Introduction 7
Section 2. Basic OTDR Information 8
Principle of OTDRs ............................................................................................................................................ 8
 .......................................................................................8
Section 3. OFL100 Operation 8
Host .......................................................................................................................................................................... 8
Function Keys ...................................................................................................................................................... 9
Main Interface ...................................................................................................................................................... 9
Auto OTDR ..........................................................................................................................................................10
 ......................................................................................................................................................10
Parameter Settings ..........................................................................................................................................11
OFL100 Pulsewidth Selection .....................................................................................................................11
Threshold/Criterion ........................................................................................................................................12
Threshold Settings ................................................................................................................................12
 ..................................................................................................................................... 12
OFL Trace ............................................................................................................................................................. 12
OTDR File Saving ..............................................................................................................................................13
File Operation .....................................................................................................................................................13
 ............................................................................................................................................................14
OPM ........................................................................................................................................................................14
VFL ..........................................................................................................................................................................14
Laser Source .......................................................................................................................................................15
Optical Loss Test .............................................................................................................................................. 15
RJ45 Sequence Testing ................................................................................................................................. 15
System Settings ............................................................................................................................................... 16
Section 4. OFL100 Troubleshooting 17
Section 5. Trace Viewer 17
OFL100
3
Tempo Communications Inc. 1390 Aspen Way • Vista, CA 92081 USA • 800-642-2155
Preface
Description


Safety
Safety is essential in the use and maintenance of Tempo Communications tools and equipment.

practices related to the use of this tool. Observe all of the safety information provided.
Purpose of This Manual
-
cedures for the Tempo Communications OFL100 handheld OTDR.
This instruction manual is free to download from www.tempocom.com
Warranty
Tempo Communications Inc. warrants to the original purchaser of these goods for use that these products will

and conditions contained in Tempo Communication’s standard one-year limited warranty.


upon request.

OFL100
Tempo Communications Inc. 1390 Aspen Way • Vista, CA 92081 USA • 800-642-2155
4
Important Safety Information










damage.
Read and understand all of the instructions and safety information in
this manual before operating or servicing this tool.



gases or fumes.
Before applying power, verify that the unit is set to match the available line
voltage.

OFL100
5
Tempo Communications Inc. 1390 Aspen Way • Vista, CA 92081 USA • 800-642-2155
Important Safety Information 

Do not connect to live bers.


Do not use repaired fuses or short-circuited fuse holders.

While there is no potential for eye damage due to


optical viewing instruments, such as microscopes,


intense beam of light energy onto the retina of the
eye, which can result in permanent damage.



because they may be connected to active laser transmitters.




VISIBLE LASER RADIATION
AVOID DIRECT EYE EXPOSURE
CLASS 2 LASER PRODUCT
MAX OUTPUT < 1mW
WAVELENGTH 650±20nm
PULSE DURATION CW
INVISIBLE LASER RADIATION DO NOT VIEW
DIRECTLY WITH OPTICAL INSTRUMENTS
CLASS 1M LASER PRODUCT
IEC 60825-1:2014
IEC 60825-1:2014
WARNING
VISIBLE LASER RADIATION
AVOID DIRECT EYE EXPOSURE
CLASS 2 LASER PRODUCT
MAX OUTPUT < 1mW
WAVELENGTH 650±20nm
PULSE DURATION CW
INVISIBLE LASER RADIATION DO NOT VIEW
DIRECTLY WITH OPTICAL INSTRUMENTS
CLASS 1M LASER PRODUCT
IEC 60825-1:2014
IEC 60825-1:2014
WARNING
OFL100
Tempo Communications Inc. 1390 Aspen Way • Vista, CA 92081 USA • 800-642-2155
6
Important Safety Information 


Avoid touching the electrolyte in the batteries, which is corrosive and may cause

Do not open the case of the unit for any reason. It contains no user-serviceable
parts.
Use this unit for the manufacturer’s intended purpose only, as described in this
manual. Any other use can impair the protection provided by the unit.




• Do not leave the unit in direct sunlight or near direct sources of heat.

• Do not immerse the unit in water or store in areas with high humidity.
• When necessary, clean the case, front panel, and rubber cover with a damp cloth.
Do not use abrasives, harsh chemicals, or solvents.
• Replace the protective dust cap when the unit is not in use.
• Store the unit and interface adapters in a cool, dry, and clean place.





before cleaning.

The OFL100 uses a polymer lithium battery and is to be charged with the supplied
charger at 5V/2A at a temperature range of 0° to 50°. The OFL100 will not charge.
Do not use any other charger to charge the OFL100.
Do not attempt to change the battery. Please send the OFL100 to our Vista plant or

OFL100
7
Tempo Communications Inc. 1390 Aspen Way • Vista, CA 92081 USA • 800-642-2155
Section 1. Introduction







loss, and homogeneity.
The OFL100 is easy to use, small, and compact with large touchscreen LCD display with graphical interfaces.
-

Basic applications:
 
 
 
• Measure fusion splice losses.

 
 
Do not discard this product or throw away!
For recycling information, go to www.TempoCom.com.
Tempo Communications Inc. hereby declares that the OFL100 is in compliance with the essential requirements

downloaded from www.TempoCom.com/support/compliance.
OFL100
Tempo Communications Inc. 1390 Aspen Way • Vista, CA 92081 USA • 800-642-2155
8
Section 2. Basic OTDR Information
Principle of OTDRs



components. Its non-destructive, single-ended connection and rapid measurement have made the OTDR an








between IOR and the smoothness of boundary.



Basic Denition and Classication of Events




Section 3. OFL100 Operation
1 OTDR/LS port
2 OPM port
3 VFL port
4 Flashlight
5 LAN 1
6 LAN 2
7 SD Card
8 Type C USB
1 Dust cover
2 4.3 inch color LCD
3 Function keys
4 Charging indicator
5 Power on status indicator
1 RJ45 Sequence Test
Remote
Main ViewTop
Host
Bottom
OFL100
9
Tempo Communications Inc. 1390 Aspen Way • Vista, CA 92081 USA • 800-642-2155
Function Keys
Main Interface
Press less than two seconds to turn on the OFL100 on.
Press for longer than two seconds to obtain the pop-up message to turn the OFL100 off.
While the OFL100 is on, a short press will toggle the flashlight on and off.
Direction key
SET key
Press to access basic OFL100 test settings.
ESC key
Exit current function.
Zoom control / AB cursor switch key
Test / Stop key
Press to start or stop test.
Press to move selection up, down, le or right.
Toggles between cursor movement and
zooming in on the currently displcayed trace.
Power ON/OFF key:
SET ESC
ON
CHARGE


function or directly select on the screen.


desired function.

screen shot. The screen shot is automatically

Date & Time USB
SD Card Shortcut menu
Battery
Flashlight
OFL100
Tempo Communications Inc. 1390 Aspen Way • Vista, CA 92081 USA • 800-642-2155
10
Auto OTDR
All parameters are automatically determined and the
OFL100 will measure the length and attenuation of a

Expert OTDR

the most accurate test result.
AutoTest
Perform an automatic test with OFL100
determined settings.
Real Test
Perform an updated real time test at a rate of

events.
Averaging Test
Perform a test with user determined settings with a
static display upon completing the measurement.
The trace and event list are
displayed at the same time.


Switch to event icon
display mode.



interface.
OFL100
11
Tempo Communications Inc. 1390 Aspen Way • Vista, CA 92081 USA • 800-642-2155
Parameter Settings
Wavelength: The wavelength can be set to
1310nm or 1550nm.
Range: The range can be set to capture the entire

Pulse width: Refers to the time width of the optical
pulse signal emitted during test. The larger the pulse



detection distance of the OTDR can be. However, the
large pulse width will cause saturation of the initial


The longer the length, the larger the pulse width,

measurement mode.
IOR: 


IOR for the most accurate measurements.
Test time: Used in the average test mode to set the
total averaging time. A longer averaging time will
result in the best signal to noise ratio.
Unit: 
or miles.
OFL100 Pulsewidth Selection
OFL100
Tempo Communications Inc. 1390 Aspen Way • Vista, CA 92081 USA • 800-642-2155
12
OFL100 Trace
Select correct parameter, the test results such as trace

Curve Zoom:

out mode.
Event List
Total length: 
Total loss:
Average Loss:
under test.
Total events: The total number of events, the number
of passed events and the number of failed events of

NO.: The order of the current event.
Type: The type of the current event.
Distance: The location of the current event.
Segment Section: the distance between the previous
event and the current event.
Loss: the loss of the current event.
Reectivity: the return loss of the current event.
/
/
Zoom in or out in X direction

Threshold/Criterion
Threshold Settings
Event loss threshold: Set the loss threshold for
connectors and fusion splices between 0.2 and 30dB.

will be listed in the event table.
Refelction threshold: Set the return loss threshold


than 40dB will be recorded in the event table.
End threshold:
determined by the end threshold setting. The range



Eligibility Criteria
Setting the threshold determines the pass or fail
criteria for each event.
Fresnel events:
connectors.
Raleigh events:
fusion splices.
OFL100
13
Tempo Communications Inc. 1390 Aspen Way • Vista, CA 92081 USA • 800-642-2155
OTDR File Saving




same day’s date.

will be automatically generated according to the rules;
File naming method 

Optical Fiber Code ID: 
code set when the line is installed:
Location A: 
Location B: 
Direction: 
from B to A;
Operator: 

number




increases in order.

1
4
+
1
2 4
+ +
3
1
2 4
+ + +
File Operation
File Operation
All the test curves are saved in the standard SD



OFL100
Tempo Communications Inc. 1390 Aspen Way • Vista, CA 92081 USA • 800-642-2155
14
VFL



cables. The VFL can also locate contaminated and
damaged connectors.
Open: Turns the visual fault locator on in continuous
wave mode.
1Hz: 
2Hz: 
Close: 
WARNING
Avoid looking directly at the laser output port;
permanent eye damage may occur
OPM
The OPM can be used to measure absolute and
relative power. The OPM can identify and measure

emitted from a compatible laser.
Wavelength: Set the desired wavelength.
Reference: Set the current power as the reference.
The Relative power will be set to 0dB where loss
measurements can be made.
Calibration: 
Threshold: Set the threshold value of power

be displayed in red; if it is lower than the threshold
value, it will be displayed in green.
Event Map
Start of ber
Raleigh loss event such as a fusion
Connector
Splitter
End of link
Rising event, caused by the
inconsistency of refractive index of two
sections of ber
OFL100
15
Tempo Communications Inc. 1390 Aspen Way • Vista, CA 92081 USA • 800-642-2155
Optical Loss Test
The optical loss test allows the technician to measure
the insertion loss of passive optical components.
To measure insertion loss:





Laser Source

that is 1310nm or 1550nm. These can be used with a



Open: Turns the laser source on.
Wavelength: Allows the technician to set the
wavelength of laser source.
Mode: 

Power + : Increase the output power.
Power - : Reduce the output power.
The slider bar at the bottom of the screen can be used

WARNING
Avoid looking directly at the laser output port;
permanent eye damage may occur
RJ45 Sequence Testing
Connect the cable under test to LAN2 port and the

instrument. Straight connect and Interleaved type
cables can be tested.
Direct Cable Test: The indicators of the host and

Interleaved Cable Test: The indicators of the host and

4,5,2,7,8.
Both T568A and T568B cables can be tested.
Do not connect live cables to the OFL100. Doing so may
result in permanent damage.
OFL100
Tempo Communications Inc. 1390 Aspen Way • Vista, CA 92081 USA • 800-642-2155
16
System Settings
Automatic shutdown: The technician can select the

a period of inactivity equal to 5/15/30/45/60 minutes or
to never shut down.
Backlight brightness: 
brightness to 20%/40%/60%/80% or 100%.
Beeper: The technician can enable or disable the beeper

Language: Allows the technician to select the desired
language.
USB connection: Allows the technician to connect and
transfer data via the USB port.
Time & date: Allows the technician to set the time
and date.
Restore factory settings: Allows the technician to

Upgrade: Provides the technician the utility to update

OFL100
17
Tempo Communications Inc. 1390 Aspen Way • Vista, CA 92081 USA • 800-642-2155
Fault Description Cause of Failure Solution
OTDR will not turn on. The battery is dead. Charge the battery and observe the charging
indicator. If the red light is displayed, continue
charging.
OTDR cannot be charged normally. Ambient temperature not within acceptable
levels.
Replace charger. Try charging the OFL100 with
the USB port.
Check that the charger is working. Set range to greater than the length of the ber.
OTDR does not measure and display
test results.
OTDR parameters are not set correctly. Set range to greater than the length of the ber.
OTDR bulkhead is contaminated. Clean OTDR bulkhead and eld ber ferrule.
OTDR bulkhead is damaged. Send to Vista for bulkhead repair.
Optical output connector mismatch. Use correct ber size and connector to match
bulkhead.
The noise of test curve is excessive,
and the waveform is not smooth.
The eld ber is not connected properly to
the bulkhead.
Clean and reconnect the eld ber to the bulk-
head.
The pulse width setting is too small. Increase the test pulse width.
Averaging time is set too low. Increase the averaging time.
Events are saturated. The pulse width is too long. Decrease test pulse width.
The last connector is open and likely a at
polished connector.
Terminate the last connector or place a Mandrel
wrap on the ber before the last connector.
After a reective event there is a long
tail.
OTDR bulkhead is contaminated. Clean OTDR bulkhead and eld ber ferrule.
OTDR bulkhead is damaged. Send to Vista for bulkhead repair.
The reection peak at the end of the
ber cannot be measured.
OTDR parameters are not set correctly. Set range to greater than the length of the ber.
The pulse width is too short. Increase the test pulse width.
False positive in curve analysis. Event threshold setting is too low. Increase the threshold analysis setting.
Section 4. OFL100 Troubleshooting

measurement records in the instrument to be uploaded to a PC via the USB port.
The measurements can then be displayed, saved, or printed as a PDF for close out reporting.
The Trace Viewer Documents:
- Fiber trace
- Test conditions/settings
- Fiber information
- File name/date
All events are listed with test results documented in tabular form.

Section 5. Trace Viewer
OFL100
Tempo Communications Inc. 1390 Aspen Way • Vista, CA 92081 USA • 800-642-2155
18
Operating Instructions of the Trace Viewer
Icon description
Menu Description
File Print Prints the currently open trace le
Export PDF Generates a PDF report from the current trace le
Bat Print Process multiple trace les at once
SOR Format Converts otdr format les into sor format les
Event Analyse
Operation
Set Analysis
Thresholds
Set loss threshold, reective loss threshold and end loss threshold
Fiber Information The optical cable number, optical cable code, optical ber number, start/end
position, operator, equipment name, test date, launch/receive optical ber and
other information of the trace can be modied.
Interface
Settings
Unit Select Set the unit of optical ber length: km, kft, mi
Mark-Line
Settings
Current location: the location of the cursor is in the original trace;
Event location: the cursor switches to the start and end event positions.
Language Change language
Icon Instructions
Open sor le
Save sor le
Horizontal enlargement and reduction of curve
Vertical enlargement and reduction of curve
Curve initialization
Move the current cursor left and right
Move curve up and down
Switch A and B cursors
Toggle curve
Analysis curve
Add and delete events
Modify the current event
OFL100
19
Tempo Communications Inc. 1390 Aspen Way • Vista, CA 92081 USA • 800-642-2155
Curve output form
Single curve printing
Open curve

 
Generate report
 

the paper report.
 
the printer and print the paper report.
Number of les Output form Required conditions
Single/multiple
curve les
Paper report Connect the computer to the printer
Electronic report NA
OFL100
Tempo Communications Inc. 1390 Aspen Way • Vista, CA 92081 USA • 800-642-2155
20
 

electronic PDF report.
Multiple curve printing











  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21

Tempo Communications OFL100 OTDR User manual

Type
User manual

Tempo Communications OFL100 OTDR is an Optical Time Domain Reflectometer used to measure the length and individual loss events on a single-mode fiber optic link. This handheld OTDR features an intuitive interface and powerful functions, making it an ideal tool for fiber optic testing and troubleshooting. With its high dynamic range and resolution, the OFL100 can accurately locate and characterize faults, breaks, and other impairments in fiber optic cables.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI