MULTISPAN MMC-1046RD,_2046R-B1-00 Owner's manual

Type
Owner's manual
ProximityPNP/NPN(Selectable)&MicroSwitch
Nonvolatile
Resetatbothfront&back
PowerSupply
ProtectionLevel
Operating
Relative
(Asperrequest)
Temperature
Humidity
230VAC,50Hz,Approx4VA
IP-65(Frontside)ASperIS/IEC60529:2001
0°CTo55°C
Upto95%RHNonCondensing
Model
Display
Size(HXWXD)
PanelCutout
Output
Range
Sensor
Memory
Reset
MMC-1046RD
96X96X43mm
92X92mm 68X68mm
72X72X45mm
UPPER:-6Digit7seg0.56”,
WhiteLEDDisplay
UPPER:-6Digit7seg0.56”,
WhiteLEDDisplay
LOWER:-4Digit7seg0.4”,
greenLEDDisplay
LOWER:-4Digit7seg0.4”,
greenLEDDisplay
MMC-2046R
1Relay,1C/O,230VAC,5A
Counter:0-999999,RPM:0-9999
Specifications:
www.multispanindia.com
Page-1
MMC-1046RD,2046R
OPERATINGMANUAL
COUNTERCUMRPMINDICATOR
MMC-1046RD,2046R
ConnectionTerminal
230V AC
50Hz,4VA
NC
I/P
NPN
+12V
I/P
PNP
GND
NO
C
L
N
1
2
3
4
5
6
7
8
9
10
11
12
13
14
!
RESET
MICRO SWITCH:-
M/S Connection 9 & 11
BATCH
MMC 1046RD
TOTAL
COUNT
RPM
R1
R2
SET
ENT RESET
TOTAL
MMC 2046R
COUNT
RPM
R1
1 2 3 4 78910
56
L N
www.multispanindia.com
MICRO SWITCH:- M/S Connection 7 & 9
230V AC
50Hz, 4VA
!
Made in India
RST
NCCNO
RELAY
+12V
I/P I/P
NPN PNP GND
MMC 1046RD-B1-00
17
8
2 3 4 5
1011121314
6
9
NOCNC
Relay
LN
!
100
270V AC
~
50/60 Hz
4VA
+12V
NPN
I/P
PNP
I/P GND RESET
MICRO S/W :- M/S Connection to 4 & 6
www.multispanindia.com
Made in India
MMC 2046R-A2-00
100to270VAC,50/60Hz,Approx4VA
www.multispanindia.com
Page-2
MMC-1046RD,2046R
KeyOperation
1)Presskeytosavethenewvalueaswellastoenterinto
SETTINGmode.
2)Presskeytoshifttothenextdigit.
3)Presskeytochangethevalue
4)Presskeyforsometimetorestartcount

COUNT
RPM
R1
R2
COUNT
RPM
BasicConfiguration
COUNT
RPM
COUNT
RPM
Presskey
SET
ENT
Presskey
SET
ENT
COUNT
RPM
COUNT
RPM
Presskey
SET
ENT
Presskey
SET
ENT
COUNT
RPM
Presskey
SET
ENT
COUNT
RPM
Presskey
SET
ENT
COUNT
RPM
SET
ENT
Presskeytosave&exit
Set Count
Relay Time
Scale
Exponent
Decimal Point
Yes / No
Memorye
Yes - when instrument is turned OFF, It will save
the memory, Even after the set point is triggered
and relay is in on condition. That Memory (counts)
will be retained once the instrument is turned ON
NO - when instrument is turned OFF, It will NOT save
the memory, Even after the set point is triggered
and relay is in on condition. That Memory (counts)
will NOT be retained once the instrument is turned ON
Count
Pulse
Fast, Slow, Medium
UP / Down
9.99 to 99.9,999
-1=X.1
-2=X.01
-3=X.001
0=X.1
1=X10
2=X100
0.00001 to 9.99999
www.multispanindia.com
Page-3
MMC-1046RD,2046R
Working
1)DoalltheconnectionasshowninconnectiondiagramandturnONinstrument.
2)UpperdisplaywillshowTotalCountValueandLowerdisplaywillshowRPMvalue.
3)Upperdisplayvalueincreasesonreceivingpulsesfromproximitysensorshowing
totalcountoftheproduction,whilelowerdisplaywillshownumberofproduction
perunittime.
4)ToshowgrandTotalPresskey
5)Resetcanbeprogrammedbytwomethod,a)ManualReset,b)AutoReset
Ifwesettime=00.0secthenitisinManualResetmode&wehavetopresskey
tostartnextcycle.Ifwesettime=00.1to99.9secthenitisinAutoResetmode&
nextcyclewillstartautomaticallyoncompletionoffirst.
6)Inmanualmodewhenwepresskeytoreset,theupperdisplayshowsʻ000000ʼ
readingandcountstartsagain.
7)Duringpowerfailurelastvaluegetsstoredinthememoryandresumescounting
fromthesamevalueongainingPoweragain.
www.multispanindia.com
Page-4
MMC-1046RD,2046R
Productimprovementandupgradeisaconstantprocedure.Soformoreupdatedoperatinginformationandsupport,
Pleasecontactourhelpline:+91-9081078681/9081078683orEmailat[email protected]Ver:2022
Allsafetyrelatedcodifications,symbolsandinstructionsthatappearinthisoperatingmanual
orontheequipmentmustbestrictlyfollowedtoensurethesafetyoftheoperatingpersonnelas
wellastheinstrument.
Ifalltheequipmentisnothandledinamannerspecifiedbythemanufacturer,itmightimpairthe
protectionprovidedbytheequipment.
=>Readcompleteinstructionspriortoinstallationandoperationoftheunit.
WARNING:Riskofelectricshock.
3)Cableusedforconnectiontopowersource,musthaveacrosssectionof1mmorgreater.Thesewires
shouldhaveinsulationscapacitymadeofatleast1.5kV.
2)Toreduceelectromagneticinterference,usewirewithadequateratingandtwistsofthesameofequalsize
shallbemadewithshortestconnection.
1)TopreventtheriskofelectricshockpowersupplytotheequipmentmustbekeptOFFwhiledoingthewiring
arrangement.Donottouchtheterminalswhilepowerisbeingsupplied.
4)Abetteranti-noiseeffectcanbeexpectedbyusingstandardpowersupplycablefortheinstrument.
1)Thisequipment,beingbuilt-in-type,normallybecomesapartofmaincontrolpanelandsuchincasethe
terminalsdonotremainaccessibletotheenduserafterinstallationandinternalwiring.
2)Donotallowpiecesofmetal,wireclippings,orfinemetallicfillingsfrominstallationtoentertheproduct
orelseitmayleadtoasafetyhazardthatmayinturnendangerlifeorcauseelectricalshocktotheoperator.
3)Circuitbreakerormainsswitchmustbeinstalledbetweenpowersourceandsupplyterminalto
facilitatepowerʻONʼorʻOFFʼfunction.Howeverthismainsswitchorcircuitbreakermustbe
installedatconvenientplacenormallyaccessibletotheoperator.
4)Useandstoretheinstrumentwithinthespecifiedambienttemperatureandhumidityrangesas
mentionedinthismanual.
WarningGuidelines
SafetyPrecautions
InstallationGuidelines
MechanicalInstallation
Maintenance
1)Preparethepanelcutoutwithproperdimensionsasshowabove.
2)Fittheunitintothepanelwiththehelpofclampgiven.
3)Theequipmentinitsinstalledstatemustnotcomeincloseproximitytoanyheatingsource,
causticvapors,oilssteam,orotherunwantedprocessbyproducts.
4)Usethespecifiedsizeofcrimpterminal(M3.5screws)towiretheterminalblock.Tighteningthe
screwsontheterminalblockusingthetighteningtorqueoftherangeof1.2N.m.
5)Donotconnectanythingtounusedterminals.

1)Theequipmentshouldbecleanedregularlytoavoidblockageofventilatingparts.
2)Cleantheequipmentwithacleansoftcloth.Donotuseisopropylalcoholoranyothercleaningagent.
3)Fusibleresistormustnotbereplacedbyoperator.
2
95mm - 3.75 inches
85mm - 3.34 inches
136mm - 5.35 inches
120mm - 4.72 inches
B
B
A
A
F
E
MODEL A
96mm 96mm 92mm 92mm 3mm 43mm
BC
D E
F
DIMENSIONS
MODEL A
72mm 72mm 68mm 68mm 3mm 45mm
BC
D E
F
DIMENSIONS
C
C
D
D
EF
BATCH
MMC 1046RD
TOTAL
COUNT
RPM
R1
R2
SET
ENT RESET
TOTAL
MMC 2046R
COUNT
RPM
R1
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

MULTISPAN MMC-1046RD,_2046R-B1-00 Owner's manual

Type
Owner's manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI