Omega PX750 Smart Kit Owner's manual

Type
Owner's manual
User’s Guide
Model PX750 Smart Kit
http://www.omega.com
PX750
Smart Kit
OMEGAnet
®
On-Line Service Internet e-mail
http://www.omega.com [email protected]
Servicing North America:
USA: One Omega Drive, Box 4047
ISO 9001 Certified Stamford, CT 06907-0047
Tel: (203) 359-1660 FAX: (203) 359-7700
Canada: 976 Bergar
Laval (Quebec) H7L 5A1
Tel: (514) 856-6928 FAX: (514) 856-6886
For immediate technical or application assistance:
USA and Canada: Sales Service: 1-800-826-6342 / 1-800-TC-OMEGASM
Customer Service: 1-800-622-2378 / 1-800-622-BESTSM
Engineering Service: 1-800-872-9436 / 1-800-USA-WHENSM
TELEX: 996404 EASYLINK: 62968934 CABLE: OMEGA
Mexico and
Latin America: Tel: (95) 800-826-6342 FAX: (95) 203-359-7807
En Espan˜ol: (95) 203-359-7803 e-mail: [email protected]
Servicing Europe:
Benelux: Postbus 8034, 1180 LA Amstelveen, The Netherlands
Tel: (31) 20 6418405 FAX: (31) 20 6434643
Toll Free in Benelux: 0800 0993344
Czech Republic: ul. Rude armady 1868, 733 01 Karvina-Hranice
Tel: 420 (69) 6311899 FAX: 420 (69) 6311114
Toll Free: 0800-1-66342 e-mail: [email protected]
France: 9, rue Denis Papin, 78190 Trappes
Tel: (33) 130-621-400 FAX: (33) 130-699-120
Toll Free in France: 0800-4-06342
Germany/Austria: Daimlerstrasse 26, D-75392 Deckenpfronn, Germany
Tel: 49 (07056) 3017 FAX: 49 (07056) 8540
Toll Free in Germany: 0130 11 21 66
United Kingdom: One Omega Drive, River Bend Technology Centre
ISO 9002 Certified Northbank, Irlam, Manchester
M44 5EX, England
Tel: 44 (161) 777-6611 FAX: 44 (161) 777-6622
Toll Free in the United Kingdom: 0800-488-488
It is the policy of OMEGA to comply with all worldwide safety and EMC/EMI regulations that apply. OMEGA is constantly pursuing certification of
its products to the European New Approach Directives. OMEGA will add the CE mark to every appropriate device upon certification.
The information contained in this document is believed to be correct, but OMEGA Engineering, Inc. accepts
no liability for any errors it contains, and reserves the right to alter specifications without notice.
WARNING: These products are not designed for use in, and should not be used for, patient-connected applications.
Omega Model PX750 Smart Pressure Transmitters
S-1
RETROFITTING OVERVIEW
The procedure for retrofitting a transmitter is divided into three parts:
1.Removing the analog electronics assembly.
2.Installing the smart electronics kit.
3.Characterizing the retrofitted transmitter.
Two tools are required to remove the analog electronics and to install
the smart electronics:
Flat-bladed screwdriver
¼-in. nut driver or wrench
The following equipment is needed to characterize the retrofitted
transmitter:
A Omega Model HC275 Communicator with
SMART FAMILY
®
Interface
An accurate pressure source, preferably 0.025% accuracy or
better
A 250 ohm resistor
The Smart Retrofit Kit, P/N PX750-SMART-KIT, contains the following items:
REMOVING THE ANALOG
ELECTRONICS ASSEMBLY
The vast majority of installed Model PX750 Transmitters have either
4–20 mA linear or 4–20 mA square root output .
The following steps describe how to remove the analog electronics
assembly from transmitters for smart retrofitting.
NOTE
Numbers in parentheses indicate parts shown in Figure C-1.
Quantity Description
1 Smart electronic assembly
1 Electronics cover
1Cover O-ring
2 Terminal eyelets
2 Board spacers
2Standoffs
Use proper earth grounding techniques when handling the
smart electronics assembly. The smart electronics
assembly is potentially sensitive to electric static discharge.
S-2
Smart Kit
LINEAR OUTPUT
SQUARE ROOT OUTPUT
1151-1151E02A 1151-1151D02B
Ref.
No.
Part
Description
1 Retainer Screws (Linear)
2 Amplifier Board (Linear)
3 Header Board Assembly
4 Standoff Screws (Linear)
5 Calibration Board (Linear)
6 Bayonet Connector Pins
7 Standoff Screws (Linear)
8 Sensor Module Electronics
9Wiring
10 Zero and Span Adjust Screws
11 Housing Cover
12 Retainer Screws (Square Root)
13 Two-board Amplifier/Squaring
Assembly (Square Root)
14 Calibration Board (Square Root)
FIGURE C-1. Model PX750 Analog Electronics.
S-3
Smart Kit
1-4 With power disconnected, remove cover and three retainer screws (1/12).
Pull the amplifier board (2/13) directly off the bayonet connectors (6).
1151-006AB
1151-007AB
Model PX750 Smart Pressure Transmitters
S-4
5.Pull the header board assembly (3) off the bayonet connectors.
The header board must be reinserted. Do not cut the wires (9) or
remove the header board.
6.If the transmitter has linear output electronics, remove the three
standoffs (4). Use a ¼-in. nut driver or wrench.
1151-008AB
1151-009AB
S-5
Smart Kit
7.Align the zero and span adjust screws (10) so that the
potentiometer blades are perpendicular to the board.
1151-010AB
Model PX750 Smart Pressure Transmitters
S-6
8.For linear output models, grip the calibration board (5) by the
interface pin. For square root output modes insert a retainer
screw into the threaded rivet for use as a handle. Pull out the
calibration board. (Removing the calibration board disables the
conventional zero and span screws.)
1151-011AB
1151-012AB
S-7
Smart Kit
Insert the standoffs (7), if necessary. The transmitter is now ready to
receive the plug-in smart electronics assembly.
1151-013AB
Model PX750 Smart Pressure Transmitters
S-8
INSTALLING
THE SMART RETROFIT KIT
Installing the smart retrofit electronics kit in the transmitter requires
installing plastic spacers to accommodate the retrofit kit and securing
the retrofit electronics. After the retrofit kit has been installed, it is
necessary to attach eyelets to the terminal side of the transmitter. The
eyelets enable hook-up with a HART-based communicator (see Figure
C-2).
FIGURE C-2. Spacer Assembly.
1.Slide the bottom half of one spacer over one of the rows of bayonet
connectors. Then repeat the procedure for the other row.
Use proper earth grounding techniques when handling the
smart electronics assembly. The smart electronics
assembly is potentially sensitive to electric static discharge.
1151-0763A01B
This side faces bottom
of electronics assembly
This side faces toward
electronics housing cover
1151-014AB
S-9
Smart Kit
2.Align the header board with the bayonet connector pins, and slide
the header board halfway down the pins.
3.Align the tops of both spacers with the bayonet connector pins,
and slide them down the pins, pushing firmly on both the spacers
and the header board to seat the board.
1151-015AB
1151-016AB
Model PX750 Smart Pressure Transmitters
S-10
4. Align the smart electronics assembly with the bayonet connector
pins, making sure all pins line up with the proper receptacles.
Next push the assembly slowly inward until it is fully seated.
5. Tighten the three captive screws on the smart electronics assembly to
secure it in place.
6. Attach the electronics cover provided in the smart retrofit kit, and
tighten securely.
7. Remove the cover from the terminal side of the transmitter.
Two eyelets that fit under the + and – signal terminal screws are
provided to facilitate connections to HART-based communicator.
The signal terminal is the upper block as indicated on the transmitter
housing.
8. Remove the signal terminal + and – screws. Attach an eyelet to each
screw, and reinsert the screws.
9. Reattach the cover on the terminal side, and tighten securely.
Model PX750 Smart Pressure Transmitters
S-11
CHARACTERIZATION The transmitter is now ready to be characterized. Characterization is a one-time
calibration of the sensor in the Model PX750 Transmitter. During characterization,
known pressures are applied to the sensor, and corresponding digital values are stored
in the EEPROM located in the smart transmitter electronics. The microprocessor uses
these values to make linearization corrections. The digital-to-analog converter then
converts the corrected digital signal into a 4-20 mA dc output. The Model PX750
Transmitter will stay in high alarm (approximately 22 mA output) until the
characterization sequence is completed.
NOTE
The transmitter must be re-characterized if either the sensor module or the smart
transmitter electronics are repaired or replaced.
Before Characterizing the 1. Be prepared to answer the following questions:
Transmitter Module type?
Module range?
Pressure units on your pressure source?
Serial number?
2. Connect the pressure source.
3. Remove the terminal side cover of the Model PX750 Smart Pressure
Transmitter.
4. Connect power supply leads to the terminal block. Apply power to
the transmitter.
NOTE
Failure to use accurate equipment may result in a transmitter that
Cannot meet its accuracy specification
.
Characterizing with a 1. Connect the Model HC275 Hart communicator electrical
Model 275 Communicator connections to the SIGNAL terminal block. The Model HC275
connections are not polarity sensitive.
2. Turn the Model HC275 on by pushing the I/O button.
3. Follow the HC275 menus to characterize:
§ Device setup
§ Detailed setup
§ Sensor
§ Pressure sensor
§ Sensor service
§ Characterize
4. Follow the instructions on the screen.
5. Verify the new transmitter configuration:
§ Tag
§ Range points
§ Linear/square root
§ Damping
6. Verify that the Fail Safe Mode Switch and the Transmitter Security Switch on
the smart electronics circuit board are correct.
7. Attach the electronics cover and tighten.
8. Put the transmitter back in service.
WARRANTY/DISCLAIMER
OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a
period of 13 months from date of purchase. OMEGA Warranty adds an additional one (1) month grace period to
the normal one (1) year product warranty to cover handling and shipping time. This ensures that OMEGA’s
customers receive maximum coverage on each product.
If the unit malfunctions, it must be returned to the factory for evaluation. OMEGA’s Customer Service
Department will issue an Authorized Return (AR) number immediately upon phone or written request. Upon
examination by OMEGA, if the unit is found to be defective, it will be repaired or replaced at no charge.
OMEGA’s WARRANTY does not apply to defects resulting from any action of the purchaser, including but not
limited to mishandling, improper interfacing, operation outside of design limits, improper repair, or
unauthorized modification. This WARRANTY is VOID if the unit shows evidence of having been tampered with
or shows evidence of having been damaged as a result of excessive corrosion; or current, heat, moisture or
vibration; improper specification; misapplication; misuse or other operating conditions outside of OMEGA’s
control. Components which wear are not warranted, including but not limited to contact points, fuses, and triacs.
OMEGA is pleased to offer suggestions on the use of its various products. However, OMEGA neither assumes
responsibility for any omissions or errors nor assumes liability for any damages that result from the use of its
products in accordance with information provided by OMEGA, either verbal or written. OMEGA warrants only
that the parts manufactured by it will be as specified and free of defects. OMEGA MAKES NO OTHER
WARRANTIES OR REPRESENTATIONS OF ANY KIND WHATSOEVER, EXPRESS OR IMPLIED,
EXCEPT THAT OF TITLE, AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED.
LIMITATION OF LIABILITY: The remedies of purchaser set forth herein are exclusive, and the total liability of
OMEGA with respect to this order, whether based on contract, warranty, negligence, indemnification, strict
liability or otherwise, shall not exceed the purchase price of the component upon which liability is based. In no
event shall OMEGA be liable for consequential, incidental or special damages.
CONDITIONS: Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as a “Basic
Component” under 10 CFR 21 (NRC), used in or with any nuclear installation or activity; or (2) in medical
applications or used on humans. Should any Product(s) be used in or with any nuclear installation or activity,
medical application, used on humans, or misused in any way, OMEGA assumes no responsibility as set forth in
our basic WARRANTY / DISCLAIMER language, and, additionally, purchaser will indemnify OMEGA and
hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the Product(s) in such
a manner.
RETURN REQUESTS / INQUIRIES
Direct all warranty and repair requests/inquiries to the OMEGA Customer Service Department. BEFORE
RETURNING ANY PRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN AUTHORIZED RETURN
(AR) NUMBER FROM OMEGA’S CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID
PROCESSING DELAYS). The assigned AR number should then be marked on the outside of the return package
and on any correspondence.
The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent breakage
in transit.
OMEGA’s policy is to make running changes, not model changes, whenever an improvement is possible.
This affords our customers the latest in technology and engineering.
OMEGA is a registered trademark of OMEGA ENGINEERING, INC.
© Copyright 1999 OMEGA ENGINEERING, INC. All rights reserved. This document may not be copied, photocopied,
reproduced, translated, or reduced to any electronic medium or machine-readable form, in whole or in part, without the prior
written consent of OMEGA ENGINEERING, INC.
FOR WARRANTY RETURNS,
please have the following information available
BEFORE contacting OMEGA:
1. Purchase Order number under which
the product was PURCHASED,
2. Model and serial number of the
product under warranty, and
3. Repair instructions and/or specific
problems relative to the product.
FOR NON-WARRANTY REPAIRS, consult OMEGA for
current repair charges. Have the following information available
BEFORE contacting OMEGA:
1. Purchase Order number to cover the
COST of the repair,
2. Model and serial number of the product, and
3. Repair instructions and/or specific problems
relative to the product.
Where Do I Find Everything I Need for
Process Measurement and Control?
OMEGA…Of Course!
TEMPERATURE
Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies
Wire: Thermocouple, RTD & Thermistor
Calibrators & Ice Point References
Recorders, Controllers & Process Monitors
Infrared Pyrometers
PRESSURE, STRAIN AND FORCE
Transducers & Strain Gauges
Load Cells & Pressure Gauges
Displacement Transducers
Instrumentation & Accessories
FLOW/LEVEL
Rotameters, Gas Mass Flowmeters & Flow Computers
Air Velocity Indicators
Turbine/Paddlewheel Systems
Totalizers & Batch Controllers
pH/CONDUCTIVITY
pH Electrodes, Testers & Accessories
Benchtop/Laboratory Meters
Controllers, Calibrators, Simulators & Pumps
Industrial pH & Conductivity Equipment
DATA ACQUISITION
Data Acquisition & Engineering Software
Communications-Based Acquisition Systems
Plug-in Cards for Apple, IBM & Compatibles
Datalogging Systems
Recorders, Printers & Plotters
HEATERS
Heating Cable
Cartridge & Strip Heaters
Immersion & Band Heaters
Flexible Heaters
Laboratory Heaters
ENVIRONMENTAL MONITORING AND CONTROL
Metering & Control Instrumentation
Refractometers
Pumps & Tubing
Air, Soil & Water Monitors
Industrial Water & Wastewater Treatment
pH, Conductivity & Dissolved Oxygen Instruments
M-3265/0799
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15

Omega PX750 Smart Kit Owner's manual

Type
Owner's manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI