ASHG07LUCA

Fujitsu ASHG07LUCA Installation guide

  • Hello! I am an AI chatbot trained to assist you with the Fujitsu ASHG07LUCA Installation guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
hcstueDsiaçnarFloñapsEonailatIkIv
EsêugutroP
hsilgnE
eçkrüT
INSTALLATION MANUAL
For authorized service personnel only.
INSTALLATIONSANLEITUNG
Nur für autorisiertes Personal.
MANUEL D'INSTALLATION
Pour le personnel agréé uniquement.
MANUAL DE INSTALACIÓN
Solo para personal autorizado.
MANUALE D'INSTALLAZIONE
Ad uso esclusivo del personale autorizzato.
MANUAL DE INSTALAÇÃO
Apenas para técnicos autorizados.
KURULUM KILAVUZU
Yetkili servis personeli içindir.
INSTALLATION MANUAL
AIR CONDITIONER
INDOOR UNIT
Compact Wall Mounted Type
PART No. 9319357003-05
9319357003-05_IM.indb 1 10/20/2017 15:56:52
En-1
TION
1. SAFETY PRECAUTIONS
• Besuretoreadthismanualthoroughlybeforeinstallation.
• Thewarningsandprecautionsindicatedinthismanualcontainimportantinformation
pertainingtoyoursafety.Besuretoobservethem.
• Handthismanual,togetherwiththeoperatingmanual,tothecustomer.Requestthe
customertokeepthemonhandforfutureuse,suchasforrelocatingorrepairingthe
unit.
WARNING
Thismarkindicatesprocedureswhich,ifimproperlyper-
formed,mightleadtothedeathorseriousinjuryoftheuser.
Requestyourdealeroraprofessionalinstallertoinstalltheindoorunitinaccordance
withthisinstallationmanual.Animproperlyinstalledunitcancauseseriousaccidents
suchaswaterleakage,electricshock,orre.Iftheindoorunitisinstalledindisregard
oftheinstructionsintheinstallationmanual,itwillvoidthemanufacturer’swarranty.
DonotturnONthepoweruntilallworkhasbeencompleted.TurningONthepowerbe-
foretheworkiscompletedcancauseseriousaccidentssuchaselectricshockorre.
Ifrefrigerantleakswhileworkisbeingcarriedout,ventilatethearea.Iftherefrigerant
comesincontactwithaame,itproducesatoxicgas.
Installationworkmustbeperformedinaccordancewithnationalwiringstandardsby
authorizedpersonnelonly.
Thisapplianceisnotintendedforusebypersons(includingchildren)withreduced
physical,sensoryormentalcapabilities,orlackofexperienceandknowledge,unless
theyhavebeengivensupervisionorinstructionconcerninguseoftheappliancebya
personresponsiblefortheirsafety.Childrenshouldbesupervisedtoensurethatthey
donotplaywiththeappliance.
CAUTION
Thismarkindicatesprocedureswhich,ifimproperly
performed,mightpossiblyresultinpersonalharmtotheuser,
ordamagetoproperty.
Readcarefullyallsecurityinformationbeforeuseorinstalltheairconditioner.
Donotattempttoinstalltheairconditionerorapartoftheairconditionerbyyourself.
Thisunitmustbeinstalledbyqualiedpersonnelwithacapacitycerticateforhandling
refrigerantuids.Refertoregulationandlawsinuseoninstallationplace.
Theinstallationmustbecarriedoutincompliancewithregulationsinforceintheplace
ofinstallationandtheinstallationinstructionsofthemanufacturer.
Thisunitispartofasetconstitutinganairconditioner.Itmustnotbeinstalledaloneor
withnon-authorizedbythemanufacturer.
Alwaysuseaseparatepowersupplylineprotectedbyacircuitbreakeroperatingonall
wireswithadistancebetweencontactof3mmforthisunit.
Contents
1. SAFETYPRECAUTIONS........................................................................................... 1
2. ABOUTTHEUNIT...................................................................................................... 1
3. GENERALSPECIFICATION...................................................................................... 2
4. ELECTRICALREQUIREMENT.................................................................................. 2
5. SELECTINGTHEMOUNTINGPOSITION................................................................ 3
6. INSTALLATIONWORK.............................................................................................. 3
7. ELECTRICALWIRING.............................................................................................. 6
8. FINISHING................................................................................................................. 7
9. FRONTPANELREMOVALANDINSTALLATION...................................................... 7
10. TESTRUN.................................................................................................................. 8
11. REMOTECONTROLLERINSTALLATION................................................................. 8
12. OPTIONALKITINSTALLATION(UTY-TWBXF)......................................................... 9
13. SELECTINGTHEREMOTECONTROLLERCUSTOMCODE............................... 10
14. FUNCTIONSETTING............................................................................................... 10
15. CUSTOMERGUIDANCE..........................................................................................11
16. ERRORCODES........................................................................................................11
Theunitmustbecorrectlygroundedandthesupplylinemustbeequippedwithadif-
ferentialbreakerinordertoprotectthepersons.
Theunitsarenotexplosionproofandthereforeshouldnotbeinstalledinexplosive
atmosphere.
Nevertouchelectricalcomponentsimmediatelyafterthepowersupplyhasbeen
turnedoff.Electricshockmayoccur.Afterturningoffthepower,alwayswait5minutes
beforetouchingelectricalcomponents.
Thisunitcontainsnouser-serviceableparts.Alwaysconsultauthorizedserviceperson-
neltorepairs.
Whenmoving,consultauthorizedservicepersonnelfordisconnectionandinstallation
oftheunit.
2. ABOUT THE UNIT
2.1. Precautions for using R410A refrigerant
Thebasicinstallationworkproceduresarethesameasconventionalrefrigerant(R22)
models.
However,paycarefulattentiontothefollowingpoints:
Sincetheworkingpressureis1.6timeshigherthanthatofconventionalrefrigerant
(R22)models,someofthepipingandinstallationandservicetoolsarespecial.(See
thetablebelow.)
Especially,whenreplacingaconventionalrefrigerant(R22)modelwithanewrefrigerant
R410Amodel,alwaysreplacetheconventionalpipingandflarenutswiththeR410Apiping
andarenuts.
ModelsthatuserefrigerantR410Ahaveadifferentchargingportthreaddiametertopre-
venterroneouschargingwithconventionalrefrigerant(R22)andforsafety.Therefore,
checkbeforehand.[ThechargingportthreaddiameterforR410Ais1/2-20UNF.]
Bemorecarefulthatforeignmatter(oil,water,etc.)doesnotenterthepipingthanwith
refrigerant(R22)models.Also,whenstoringthepiping,securelysealtheopeningby
pinching,taping,etc.
Whenchargingtherefrigerant,takeintoaccounttheslightchangeinthecompositionof
thegasandliquidphases.Andalwayschargefromtheliquidphasewhererefrigerant
compositionisstable.
2.2. Special tools for R410A
Tool name Contents of change
Gauge manifold
Pressureis high and cannot be measured with a conven-
tional (R22) gauge. To prevent erroneous mixing of other
refrigerants,thediameterofeachporthasbeenchanged.
It is recommended the gauge with seals -0.1 to 5.3 MPa
(-1to53bar)forhighpressure.
-0.1to3.8MPa(-1to38bar)forlowpressure.
Charge hose
Toincreasepressureresistance,thehosematerialandbase
sizewerechanged.
Vacuum pump
Aconventional vacuum pump can be used by installing a
vacuumpumpadapter.
Gas leakage detector SpecialgasleakagedetectorforHFCrefrigerantR410A.
Copper pipes
Itisnecessarytouseseamlesscopperpipesanditisdesirablethattheamountofresidual
oilislessthan40mg/10m.Donotusecopperpipeshavingacollapsed, deformed or
discoloredportion(especiallyonthe interiorsurface).Otherwise,theexpansionvalueor
capillarytubemaybecomeblockedwithcontaminants.
AsanairconditionerusingR410AincurspressurehigherthanwhenusingR22,itisneces-
sarytochooseadequatematerials.
WARNING
Donotusetheexisting(forR22)pipingandarenuts.
Iftheexistingmaterialsareused,thepressureinsidetherefrigerantcyclewillriseand
causefailure,injury,etc.(UsethespecialR410Amaterials.)
Wheninstallingandrelocatingtheairconditioner,donotmixgasesotherthanthe
speciedrefrigerant(R410A)toentertherefrigerantcycle.
Ifairorothergasenterstherefrigerantcycle,thepressureinsidethecyclewillriseto
anabnormallyhighvalueandcausefailure,injury,etc.
AIRCONDITIONER INSTALLATIONMANUAL
CompactWallMountedType
PARTNo.9319357003-05
[Originalinstructions]
• Branchboxwhichisspeciedinthismanualistheequipmenttosupporttheindoorunit
ofmulti-connectiontype.
9319357003-05_IM.indb 1 10/20/2017 15:56:53
En-2
2.3.
For authorized service personnel only.
WARNING
Fortheairconditionertooperatesatisfactorily,installitasoutlinedinthisinstallation
manual.
Connecttheindoorunitandoutdoorunitorbranchboxwiththeairconditionerpiping
andcablesavailablefromyourlocaldistributor.Thisinstallationmanualdescribesthe
correctconnectionsusingtheinstallationsetavailablefromyourlocaldistributor.
Donotturnonthepoweruntilallinstallationworkiscomplete.
CAUTION
Thisinstallationmanualdescribeshowtoinstalltheindoorunitonly.
Toinstalltheoutdoorunitorbranchbox,refertotheinstallationmanualincludedwith
theoutdoorunitorbranchbox.
• Becarefulnottoscratchtheairconditionerwhenhandlingit.
• Afterinstallation,explaincorrectoperationtothecustomer,usingtheoperatingmanual.
2.4. Accessories
Thefollowinginstallationaccessoriesaresupplied.Usethemasrequired.
Name and Shape
Q’ty
Name and Shape
Q’ty
Operatingmanual
1
Remotecontroller
holder
1
Installationmanual
(Thismanual)
1
Clothtape
1
Wallhookbracket
1
Tappingscrew
(large)
5
Remotecontroller
1
Tappingscrew
(small)
2
Battery
2
Aircleaningfilter
2
SealA
Itisusedwhenthediameterof
gaspipeisØ12.70ormore.
ItisnecessarywhenusingAS14.
1
Thefollowingitemsarenecessarytoinstallthisairconditioner.(Theitemsarenotinclud-
edwiththeairconditionerandmustbepurchasedseparately.)
Name Q’ty Name Q’ty
Connectionpipeassembly 1 Wallcap 1
Connectioncable(4-conductor)
1 Saddle 1set
Wallpipe 1 Drainhose 1
Decorativetape 1 Tappingscrews 1set
Vinyltape 1 Sealant 1
2.5. Optional parts
Refertoeachinstallationmanualforthemethodofinstallingoptionalparts.
Parts name Model No. Application
Wiredremotecontroller* UTY-RNNÜM Forairconditioneroperation
Simpleremotecontroller* UTY-RSNÜM Forairconditioneroperation
Externalconnectkit* UTY-XWZXZ5 Forcontrolinput/outputport
Communicationkit UTY-TWBXF Fortheinstallationofoptionalparts
*Optionalcommunicationkitisnecessaryfortheinstallation.
3. GENERAL SPECIFICATION
Thisinstallationmanualbrieyoutlineswhereandhowtoinstalltheairconditioningsystem.Please
readovertheentiresetofinstructionsfortheindoorandoutdoorunitsandmakesureallaccessory
partslistedarewiththesystembeforebeginning.
3.1. Type of copper pipe and insulation material
CAUTION
Refertotheinstallationmanualfortheoutdoorunitfordescriptionofallowablepipelength
andheightdifference.
Selecting pipe sizes
Thediametersoftheconnectionpipesaccordingtothecapacityoftheindoorunit.
Refertothefollowingtablefortheproperdiametersoftheconnectionpipesbetweenthe
indoorunitandoutdoorunitorbranchbox.
Capacityofindoorunit
Gaspipesize(thickness)
[mm]
Liquidpipesize(thickness)
[mm]
7,9,12 Ø9.52(0.8) Ø6.35(0.8)
14 Ø12.70(0.8) Ø6.35(0.8)
CAUTION
Installheatinsulationaroundboththegasandliquidpipes.Failuretodosomay
causewaterleaks.
Useheatinsulationwithheatresistanceabove120°C.Reversecyclemodelonly)
Inaddition,ifthehumiditylevelattheinstallationlocationoftherefrigerantpipingis
expectedtoexceed70%,installheatinsulationaroundtherefrigerantpiping.Ifthe
expectedhumiditylevelis70-80%,useheatinsulationthatis15mmorthickerandif
theexpectedhumidityexceeds80%,useheatinsulationthatis20mmorthicker.
Ifheatinsulationisusedthatisnotasthickasspecied,condensationmayformonthesurface
oftheinsulation.
Inaddition,useheatinsulationwithheatconductivityof0.045W/(m•K)orless20°C.
3.2. Additional materials required for installation
A.Refrigeration(armored)tape
B.Insulatedstaplesorclampsforconnectingwire(Seeyourlocalelectricalcodes.)
C.Putty
D.Refrigerationlubricant
E.Clampsorsaddlestosecurerefrigerantpiping
4. ELECTRICAL REQUIREMENT
Theindoorunitispoweredfromtheoutdoorunitorbranchbox.Donotpowerindoorunit
fromseparatepowersource.
WARNING
Refertolocalcodesforacceptablecabletype.
9319357003-05_IM.indb 2 10/20/2017 15:56:55
En-3
5. SELECTING THE MOUNTING POSITION
Decidethemountingpositionwiththecustomerasfollows:
5.1. Indoor unit
(1) Installtheindoorunitlevelonastrongwallwhichisnotsubjecttovibration.
(2) Theinletandoutletportsshouldnotbeobstructed:theairshouldbeabletoblowall
overtheroom.
(3)
Installtheunitadedicatedelectricalbranchcircuit.
(4)
Donotinstalltheunitwhereitwillbeexposedtodirectsunlight.
(5)
Installtheunitwhereconnectiontotheoutdoorunitorbranchboxiseasy.
(6) Installtheunitwherethedrainpipecanbeeasilyinstalled.
(7) Takeservicing,etc.intoconsiderationandleavethespacesshownin“6.1.Installation
dimensions”.Alsoinstalltheunitwheretheltercanberemoved.
Correctinitialinstallationlocationisimportantbecauseitisdifculttomoveunitafteritis
installed.
WARNING
Selectinstallationlocationsthatcanproperlysupporttheweightoftheindoor.Installthe
unitssecurelysothattheydonottoppleorfall.
CAUTION
Donotinstalltheunitinthefollowingareas:
•
Areawithhighsaltcontent,suchasattheseaside.Itwilldeterioratemetalparts,causingtheparts
tofailortheunittoleakwater.
•
Arealledwithmineraloilorcontainingalargeamountofsplashedoilorsteam,suchasa
kitchen.
Itwilldeteriorateplasticparts,causingthepartstofailortheunittoleakwater.
•
Areathatgeneratessubstancesthatadverselyaffecttheequipment,suchassulfuricgas,chlorine
gas,acid,oralkali.
Itwillcausethecopperpipesandbrazedjointstocorrode,whichcancauserefrigerantleakage.
•
Areathatcancausecombustiblegastoleak,containssuspendedcarbonbersorammable
dust,orvolatileinammablessuchaspaintthinnerorgasoline.
•
Ifgasleaksandsettlesaroundtheunit,itcancauseare.
•
Areawhereanimalsmayurinateontheunitorammoniamaybegenerated.
Donotusetheunitforspecialpurposes,suchasstoringfood,raisinganimals,growing
plants,orpreservingprecisiondevicesorartobjects.
Itcandegradethequalityofthepreservedorstoredobjects.
Donotinstallwherethereisthedangerofcombustiblegasleakage.
Donotinstalltheunitnearasourceofheat,steam,orammablegas.
Installtheunitwheredrainagedoesnotcauseanytrouble.
Installtheindoorunit,outdoorunit,branchbox,powersupplycable,transmissioncable,
andremotecontrolcableatleast1mawayfromatelevisionorradioreceivers.The
purposeofthisistopreventTVreceptioninterferenceorradionoise.
(Eveniftheyareinstalledmorethan1mapart,youcouldstillreceivenoiseundersome
signalconditions.)
Ifchildrenunder10yearsoldmayapproachtheunit,takepreventivemeasuressothat
theycannotreachtheunit.
Installtheindoorunitonthewallwheretheheightfromtheoorsmorethan1.8m.
6. INSTALLATION WORK
6.1. Installation dimensions
160mmorover**
1.5morover
Remote
controller
Remotecontroller
holder
Tappingscrews
(small,accessories)
1.8morover
(Wallcap)
120mmorover*
Wallhook
bracket
160mmorover**
* Thedistance between thewall hook bracket andthe ceiling
shouldbe120mmormore.
** Thesidenexttothesidewallmustfollowthesizeindicatedinthe
figure.
6.2. Indoor unit piping direction
Thepipingcanbeconnectedinthe6directionsindicatedinthefollowing.
Whenthepipingisconnectedindirection(2),(3),(4)or(5),cutalongthepipinggroove
inthesideoftheundercoverwithahacksaw.
(Rear)
(2)Right
outlet
(5)Left
outlet
(6)Leftrear
outlet
(3)Rightbottomoutlet
(1)Rightrearoutlet
(4)Leftbottomoutlet
6.3. Under cover removal
(1)Remove thescrew caps andscrews fromthe
undercover(ineachof3places).
(2)Liftupthecentralpartoftheundercover.
(3)Releasethetabsbypressingonthesideofthe
undercover(in2placesontheside).
(4)
Removetheundercoverwhileturningit.
(1)
(1)
(1)
Undercover
Screwcap
Screw
(4)
(4)
(3)
(2)
6.4. Under cover installation
(1)Pushthetabsonthesideoftheundercoverinto
thebase(in2placesontheside).
(2)Pressinthetoppartsofthetrianglemarkingson
theundercover(in2places).
(3)Attachthescrews(in3places).
(4)Attachthescrewcaps(in3places).
(1)
(1)
(1)
(2)
(2)
6.5. Cutting the knockout hole
Cuttingtheknockoutholeforpipingonundercover:
Thepipingcanbeconnectedinthe6directionsindicatedinthefollowing.
Whenthepipingisconnectedindirection(2),(3),(4)or(5),useacuttingtooltocutalong
thegrooveforthepipingthatwillcomingoutoftheundercover.
For(5)Leftoutlet
For(4)Leftbottomoutlet
For(3)Rightbottomoutlet
For(2)Rightoutlet
9319357003-05_IM.indb 3 10/20/2017 15:57:56
En-4
6.6.
Cutting the hole in the wall for the connecting piping
(1) Cuta65mmdiameterholeinthewallatthepositionshowninthefollowing.
(2) Cuttheholesothattheoutsideendislower(5to10mm)thantheinsideend.
(3) Alwaysalignthecenterofthewallhole.Ifmisaligned,waterleakagewilloccur.
(4)
Cutthewallpipetomatchthewallthickness,stickitintothewallcap,fastenthecapwith
vinyltape,andstickthepipethroughthehole.
(5) Forleftpipingandrightpiping,cuttheholealittlelowersothatdrainwaterwillow
freely.
Wall
Fastenwith
vinyltape
65mmdia.hole
65mmdia.hole
Wallhookbracket
Centermark
Centermark
Wallcap*
Wallpipe*
(Inside)
(Outside)
5to10mmlow
*Locallypurchased
WARNING
Ifthewallpipeisnotused,thecableinterconnectingtheindoorunit(s)andoutdoorunit
orbranchboxmaytouchmetalandcauseelectricdischarge.
6.7. Installing the wall hook bracket
(1)Installthewallhookbracketsothatitiscorrectlypositionedhorizontallyandvertically.
Ifthewallhookbracketistitled,waterwilldriptotheoor.
(2)Install thewall hook bracketso thatitis strongenough tosupportthe weightof the
unit.
•
Fastenthewallhookbrackettothewallwith5ormorescrewsthroughtheholesnearthe
outeredgeofthebracket.
•
Checkthatthereisnorattleatthewallhookbracket.
Wallhookbracket
Tappingscrews
(large,accessories)
CAUTION
Installthewallhookbracketlevel,bothhorizontallyandvertically.
6.8.
Forming the drain hose and pipe
[Rear piping, Right piping, Bottom piping]
•Installtheindoorunitpipinginthedirectionofthewallholeandbindthedrainhose
andpipetogetherwithvinyltape.
•Installthepipingsothatthedrainhoseisatthebottom.
•Wrapthepipesoftheindoorunitthatarevisiblefromtheoutsidewithdecorativetape.
[For Left rear piping, Left piping]
Interchangethedraincapandthedrainhose.
CAUTION
Insert drain hose and drain capsecurely.Drain shouldslope down to avoid water
leakage.
When inserting, be sure not to attach any material besides water.If any other
materialisattached,itwillcausedeteriorationandwaterleakage.
Afterremovingdrainhose,besurenottoforgetmountingdraincap.
Besuretoxthedrainhosewithtapetothebottomofpiping.
Preventdrainwaterfreezingunderlowtemperatureenvironment.
When installing indoor unit’s drain hose outdoors, necessary measure for frost
protectionshouldbetakentopreventdrainwaterfreezing.
Underlowtemperatureenvironment(whenoutdoortemperatureunder 0 °C), after
coolingoperationis executed,waterinthedrain hosecouldbe frozen.Oncedrain
waterisfrozen,thedrainhosewillbeblockedandwaterleakagemayresultatthe
indoorunit.
Installation method of Drain cap
Useahexagonalwrench4mmatoppositesidetoinsert
thedraincap,tillthedraincapcontactsthetipofdrain
cock.
Rightpiping
Bottompiping
Bindwithvinyltape
Refrigerantpipes(top)
Rearpiping
Indoorunitdrainhose(bottom)
Forleftoutletpiping,
cutoffthepiping
outletcuttinggroove
withahacksaw.
Indoorunit
drainhose
Draincap
Removethedraincapbypulling
attheprojectionattheendofthe
capwithpliers,etc.
Removal method of drain hose
Removethescrewattheleftof
drainhoseandpulloutdrainhose.
Installation method of drain hose
Vertically insertthe drain hose toward the
inside,sothatthedrainxture(white)canac-
curately align with thescrew hole around the
draincock.
Afterinsertingand before replacing, please
reinstallandxtheremovedscrews.
• Pleaseholdaroundthejointofthedrainhoseduringworking.
•
Asthescrewisinside,besuretousescrewdrivertreatedwithmagnet.
Screw
Drainxture
Drainhose
Screwhole
Draincock
Drainhose
Screw
Drainxture
•
Forleftpipingandleftrearpiping,alignthemarksonthewallhookbracketandshapethe
connectionpipe.
•Bendtheconnectionpipingatabendradiusof70mmormoreandinstallnomorethan
35mmfromthewall.
•
Afterpassingtheindoorpipinganddrainhosethroughthewallhole,hangtheindooruniton
thehooksatthetopandbottomofthewallhookbracket.
Nogap
Hexagonal
wrench
Drain
cock
Draincap
9319357003-05_IM.indb 4 10/20/2017 15:58:10
En-5
[Installing the indoor unit]
• Hangtheindoorunitfromthehooksatthetopofthewallhookbracket.
• Insertthespacer,etc.betweentheindoorunitandthewallhookbracketandseparate
thebottomoftheindoorunitfromthewall.
Indoorunit
Wallhookbracket
(Spacer)
Connectionpipe(6.35mmdia.)
Alignthemarks
Indoorunit
Connectionpipe(9.52or12.7mmdia.)
Tophooks
Bottomhooks
Wallhookbracket
BendR70mmwith
apipebender
Afterhookingtheindoorunittothetophook,hookthettingsoftheindoorunittothe2
bottomhookswhileloweringtheunitandpushingitagainstthewall.
6.9. Flare connection (Pipe connection)
CAUTION
Tightenthearenutswithatorquewrenchusingthespeciedtighteningmethod.Oth-
erwise,thearenutscouldbreakafteraprolongedperiod,causingrefrigeranttoleak
andgeneratehazardousgasiftherefrigerantcomesintocontactwithaame.
6.9.1. Flaring
UsespecialpipecutterandaretoolexclusiveforR410A.
(1) Cuttheconnectionpipetothenecessarylengthwithapipecutter.
(2) Holdthepipedownwardsothatcuttingswillnotenterthepipeandremoveanyburrs.
(3)
Insertthearenut(alwaysusethearenutattachedtotheindoorunit(s)andoutdoorunit
orbranchbox respectively) onto the pipe and perform the are processing with aare
tool.UsethespecialR410Aaretool,ortheconventionalaretool.Leakageofrefriger-
antmayresultifotherarenutsareused.
(4) Protect thepipesbypinchingthem orwith tapetopreventdust,dirt, orwater from
enteringthepipes.
Die
A
Pipe
B
L
Checkif[L]isflared uniformly
andisnotcrackedorscratched.
Pipeoutsidediameter
[mm(in.)]
DimensionA[mm]
DimensionB[mm]
FlaretoolforR410A,
clutchtype
6.35(1/4)
0to0.5
9.1
9.52(3/8) 13.2
12.70(1/2) 16.6
15.88(5/8) 19.7
19.05(3/4) 24.0
WhenusingconventionalaretoolstoareR410Apipes,thedimensionAshouldbeap-
proximately0.5mmmorethanindicatedinthetable(foraringwithR410Aaretools)to
achievethespeciedaring.UseathicknessgaugetomeasurethedimensionA.
Widthacross
flats
Pipeoutsidediameter[mm(in.)]
Widthacrossflats
ofFlarenut[mm]
6.35(1/4) 17
9.52(3/8) 22
12.70(1/2) 26
15.88(5/8) 29
19.05(3/4) 36
6.9.2. Bending pipes
• Ifpipesareshapedbyhand,becarefulnottocollapsethem.
• Donotbendthepipesinananglemorethan90°.
• Whenpipesarerepeatedlybendorstretched,thematerialwillharden,makingitdifcult
tobendorstretchthemanymore.
• Donotbendorstretchthepipesmorethan3times.
CAUTION
Topreventbreakingofthepipe,avoidsharpbends.
Ifthepipeisbentrepeatedlyatthesameplace,itwillbreak.
6.9.3. Pipe connection
CAUTION
BesuretoInstallthepipeagainsttheportontheindoorunitcorrectly.Ifthecentering
isimproper,thearenutcannottightensmoothly.Ifthearenutisforcedtoturn,the
threadswillbedamaged.
Donotremovethearenutfromtheindoorunitpipeuntilimmediatelybeforecon-
nectingtheconnectionpipe.
Holdthetorquewrenchatitsgrip,keepingitintherightanglewiththepipe,inorder
totightenthearenutcorrectly.
Tightenthe are nuts with a torque wrench usingthe specied tightening method.
Otherwise,thearenutscouldbreakafteraprolongedperiod,causingrefrigerantto
leakandgeneratehazardousgasiftherefrigerantcomesintocontactwithaame.
Connectthepipingsothatthecontrolboxcovercaneasilyberemovedforservicing
whennecessary.
Inordertopreventwaterfromleakingintothecontrolbox,makesurethatthepiping
iswellinsulated.
Whentheflarenutistightenedproperlybyyourhand,holdthebodysidecouplingwitha
wrench,thentightenwithatorquewrench.(Seethetablebelowfortheflarenuttightening
torques.)
Tightenwith2wrenches.
Holdingwrench
Flarenut
Connectionpipe
Torquewrench
Indoor unitpipe
(Bodyside)
Flarenut[mm(in.)] Tighteningtorque[N·m(kgf·cm)]
6.35(1/4)dia. 16to18(160to180)
9.52(3/8)dia. 32to42(320to420)
12.70(1/2)dia. 49to61(490to610)
15.88(5/8)dia. 63to75(630to750)
19.05(3/4)dia. 90to110(900to1,100)
9319357003-05_IM.indb 5 10/20/2017 15:58:23
En-6
7. ELECTRICAL WIRING
Cable Cablesize(mm
2
) Type Remarks
Connectioncable 1.5 Type60245IEC57 3Cable+Ground,1φ230V
Max.CableLength:Limitvoltagedroptolessthan2%.Increasecablegaugeifvoltagedropis
2%ormore.
7.1.
Wiring system diagram
WARNING
Beforeconnectingthewires,makesurethepowersupplyisOFF.
Everywiremustbeconnectedrmly.
Nowireshouldbeallowedtotouchrefrigeranttubing,thecompressororanymoving
part.
Loosewiringmaycausetheterminaltooverheatorresultinunitmalfunction.Are
hazardmayalsoexist.Therefore,besureallwiringistightlyconnected.
Connectwirestothematchingnumbersofterminals.
Groundingline
Type60245IEC57
Cablesize1.5mm
2
(Inter-unit)
OUTDOORUNIT
orBRANCHBOX
Pleaseconnectitto
thespeciedterminal.
INDOORUNIT
TERMINAL
Powerline
Controlline
7.2.
Indoor unit wiring
(1)Bypullingthetaboneachsideoftheintakegrillewithyourhandtowardyou,open
theopenpanelandtheintakegrilletogetheruntilitbecomehorizontally.
(2)Fixtheintakegrillewiththegrillestay.
(Forthedetails,referto“9.1.Intakegrilleremoval”.)
(3)Removethewirecover.(Removethe1screw.)
(4)Removethecableclamp.(Removethe1screw.)
(5)Bendtheendoftheconnectioncableasshowninthegure.
(6)Connecttheendoftheconnectioncablefullyinsertingintotheterminalblock.
(7)Fastentheconnectioncablewithacableclamp.(Attachthe1screw.)
Endofconnectioncable
30mm
Cableclamp
Connection
cable
Screw
Screw
Wirecover
Connectioncable
Terminalblock
Cableclamp
Connection
cable
Screw
Screw
Wirecover
50mm
(8)Insertthewirecovertabintothesquareholeoftheindoorunitandfastenwitha
screw.
(9)Returnthegrillestaytotheoriginalposition.
(Referto“9.2.Intakegrilleinstallation”.)
(10)Closetheopenpanelandtheintakegrilletogether.
(Referto“9.2.Intakegrilleinstallation”.)
7.3. How to connect wiring to the terminals
Cautionwhenwiringcable
Whenstrippingofftheinsulationofaleadwire,alwaysuseaspecialtoolsuchasawire
stripper.Ifthereisnospecialtoolavailable,carefullystriptheinsulationwithaknifeetc.
(1) Useringterminalswithinsulatingsleevesasshowninthegurebelowtoconnectto
theterminalblock.
(2) Securelyclamptheringterminalstothewiresusinganappropriatetoolsothatthe
wiresdonotcomeloose.
Strip:10mm
Ring
terminal
Sleeve
(3) Usethespeciedwires,connectthemsecurely,andfastenthemsothatthereisno
stressplacedontheterminals.
(4) Useanappropriatescrewdrivertotightentheterminalscrews.Donotuseascrew-
driverthatistoosmall,otherwise,thescrewheadsmaybedamagedandpreventthe
screwsfrombeingproperlytightened.
(5) Donottightentheterminalscrewstoomuch,otherwise,thescrewsmaybreak.
Screwwithspecialwasher
Wire
Ringterminal
Terminalblocks
Wire
Screwwithspecialwasher
Ringterminal
(6) Seethetablebelowfortheterminalscrewtighteningtorques.
Tighteningtorque[N·m(kgf·cm)]
M4screw 1.2to1.8(12to18)
CAUTION
Attachthecableclamprmlybyholdingtheconnectioncable,andmakesurethatthe
clampisxedsecurely.
Incompleteattachmentofthecableclampmightcauseamalfunctionoftheopen
panel.
Matchtheterminalblocknumbersandconnectioncablecolorswiththoseofthe
outdoorunitorbranchbox.
Erroneouswiringmaycauseburningoftheelectricparts.
Connecttheconnectioncablesrmlytotheterminalblock.Imperfectinstallationmay
causeare.
Alwaysfastentheoutsidecoveringoftheconnectioncablewiththecableclamp.(If
theinsulatorischafed,electricdischargemayoccur.)
Alwaysconnectthegroundwire.
Donotusetheearthscrewoftheindoorunitfortheconnectionotherthanaspecied
outdoorunitorbranchbox.
9319357003-05_IM.indb 6 10/20/2017 15:58:24
En-7
9. FRONT PANEL REMOVAL AND INSTALLATION
CAUTION
Donotopentheopenpanelforciblywithyourhands.
Openingthepanelforciblywithyourhandsmaycauseaproduct
malfunction.
(Openpanelisautomaticallyopenedorclosedwhenthepower
supplyisturnedonor off,orwhen theindoorunitoperationis
stopped.)
9.1. Intake grille removal
(1) Bypullingthetaboneachsideoftheintakegrillewithyourhandtowardyou,open
theopenpanelandtheintakegrilletogetheruntilitbecomehorizontally.
Tab Tab
• Do not open the open panel only.Forcible opening of the open panel might
causeadamage.
•Whenyouopentheopenpanelandtheintakegrille,donotopenthemforciblyto
wideranglethanhorizontal.Forcibleopeningmightcauseadamage.
GOOD PROHIBITED
Intakegrilletab Intakegrilletab
OpenPanel
(2) Whileholdingtheintakegrillewithyourhand,raisethegrillestayindirectionofthe
arrowuntiltheclawclicks.
Grillestay
Click
Claw
(3) Fixtheintakegrillewiththegrillestay.
(4) Removeeachscrewsecuringthegrille-fall-protectionclamper,bothontheupperleft
andrightofthefrontpanel.
(5) Pulltheopen paneland theintake grilletogethertowardyou,and separateit from
theunit.
(a)
(b)
(c)
(d)
Openpaneland
intakegrille
Openpaneland
intakegrille
Grillestay
Grille-fall-
protection
clamper
Grillestay
9.2. Intake grille installation
(1) While holding the open panel and the intake grille horizontally,insert the grille-
installation shaft into the pillow block, both on the upper left and right of the front
panel.
Grille-installationshaft
Pillowblock
(2) Whileholdingtheintakegrillewithyourhand,xitwiththegrillestay.
(3) Secureeachofthefall-protectionclamperwiththescrew,bothontheupperleftand
right.
8. FINISHING
(1) Insulatebetweenpipes.
• Insulatesuctionanddischargepipesseparately.
• Forrear,right,andbottompiping,overlaptheconnectionpipeheatinsulationand
indoorunitpipeheatinsulationandbindthemwithvinyltapesothatthereisno
gap.
• Forleftandleftrearpiping,butttheconnectionpipeheatinsulationandindoorunit
pipeheatinsulationtogetherandbindthemwithandvinyltapesothatthereisno
gap.
• Forleftandleftrearpiping,wraptheareawhichaccommodatestherearpiping
housingsectionwithclothtape.
• Forleftandleftrearpiping,bindtheconnectioncabletothetopofthepipewith
vinyltape.
• Forleftandleftrearpiping,bundlethepipinganddrainhosetogetherbywrapping
themwithclothtapeovertherangewithinwhichtheytintotherearpiping
housingsection.
(2) Temporarilyfastentheconnectioncablealongtheconnectionpipewithvinyltape.
(Wraptoabout1/3thewidthofthetapefromthebottomofthepipesothatwater
doesnotenter.)
(3) Fastentheconnectionpipetotheoutsidewallwithasaddle,etc.
(4) Fillthegapbetweentheoutsidewallpipeholeandthepipewithsealersothatrain
waterandwindcannotblowin.
(5) Fastenthedrainhosetotheoutsidewall,etc.
Pipe
Saddle*
Outsidewallcap*
Sealerputty*
(Outdoors)
*Locallypurchased
Wall
SealAisusedwhenthediameter
ofgaspipeisØ12.70ormore.
Butt connection pipe (heat
insulation)againsttheindoor
unitpipe(heatinsulation)and
wrapwithsealAsothatthere
isnogap.
Overlaptheinsulation
Vinyltape
Wrapwithclothtape
Clothtape
Drainhose
Connectioncable
Pipe
Drainhose
Drainhose Connectionpipe
Wallpipe Connectioncable
Left piping For connection from the left rear
Pipe
Connectionpipe
(heatinsulation)
Bindthepipestogether
sothatthereisnogap.
Indoorunitpipe
(heatinsulation)
Checkthefollowing:
GOOD
Drainhose
Saddle
Liftedup Wave Endinwater
PROHIBITED
Openpanel
9319357003-05_IM.indb 7 10/20/2017 15:58:31
En-8
(4) Lifttheintakegrilleslightlytoreleasethegrillestay,andreturnthegrillestaytothe
originalposition.
Grillestay
Click
(5) PresspointAandpointClightlyuntiltheyclick,thenpresslightlyatpointB.
A B C
Click
Click
ForpointC,please
slightlypressinnerside.
Iftheindoorunitoperationisstartedwithoutclosingtheintakegrillermly,thelampsash
andtheindoorunitoperationisstopped.
Whenthegrilleisclosedrmly,ashingofthelampsstopandtheindoorunitstartstheoperation.
9.3. Front panel removal
(1) Removeintakegrille.(Referencetheintakegrilleremoval.)
(2) Removewirecover.(Removethe1screw.)
(3) Remove4screws.
Screws(4positions)
Wirecover
Screw(Wirecover)
(4) Thefrontpanelispulledtothefront,raisingtheuppersurface,andafrontpanelis
removed.
Frontpanel
9.4. Front panel installation
(1) First, t the lower part of the front panel, and insert top and bottom hooks. (2 top
sides,7bottomsides,2center)
Indoorunit
Bottomholes
(3position)
Bottomhooks
(3position)
Bottomholes
(4position)
Centerholes
(2position)
Centerhooks
(2position)
Tophooks
(2position)
Topholes
(2position)
Indoorunit
Frontpanel
Bottomhooks
(2position)
Bottomhooks
(2position)
Frontpanel
(2)Attachthe4screws.
(3)Attachthewirecover.(Attachthe1screw.)
(4)Attachtheintakegrille.
CAUTION
InstalltheFrontpanelandIntakegrillesecurely.Ifinstallationisimperfect,theFront
panelorIntakegrillemayfalloffandcauseinjury.
10. TEST RUN
Check items
(1) Isoperationofeachbuttonontheremotecontrollerunitnormal?
(2) Doeseachlamplightnormally?
(3) Doairowdirectionlouversoperatenormally?
(4) Isthedrainnormal?
(5) Donothaveanabnormalnoiseandvibrationduringoperation?
Donotoperatetheairconditionerintestrunforalongtime.
[Operation method]
Fortheoperationmethod,refertotheoperatingmanual.
Theoutdoorunit,maynotoperate,dependingontheroomtemperature.Inthiscase,
keeponpressingtheMANUALAUTObuttonoftheindoorunitformorethan10
seconds.TheOPERATIONindicatorlamp(green)andTIMERindicatorlamp(orange)
willbegintoashsimultaneouslyduringcoolingtestrun.Then,heatingtestrunwill
begininabout3minuteswhenHEATisselectedbytheremotecontroloperation.(Please
followtheoperatingmanualforremotecontroloperation.)
(Whentheairconditionerisrunningbypressingthetestrunbutton,theOPERATION
indicatorlampandTIMERindicatorlampwillsimultaneouslyashslowly.)
PressandholdMANUALAUTO
buttonfor10seconds
MANUALAUTObutton
Whenendingthetestrun,keeponpressingtheMANUALAUTObuttonoftheindoor
unitformorethan3seconds.
[Using the wired remote controller] (Option)
Fortheoperationmethod,refertotheoperatingmanual.
(1) Stoptheairconditioneroperation.
(2) PresstheMODEbuttonandtheFANbuttonsimultaneouslyfor
2secondsormoretostartthetestrun.
Testrundisplay
(3) Pressthestart/stopbuttontostopthetestrun.
11. REMOTE CONTROLLER INSTALLATION
CAUTION
Check that the indoor unit correctly receivesthe signal from the remote controller,
theninstalltheremotecontrollerholder.
Selecttheremotecontrollerholderselectionsitebypayingcarefulattentiontothefol-
lowing:
Avoidplacesindirectsunlight.
Selectaplacethatwillnotbeaffectedbytheheatfromastove,etc.
11.1. Remote controller holder installation
Installtheremotecontrolleramaximumdistanceof6mfromtheremotecontrolsignal
receiver.However,when installing the remote controller,check that it operates cor-
rectly.
I
nstalltheremotecontrollerholdertoawall,pillar,etc.withthetappingscrew.
Remote controller
holder xing
Remote controller
mounting
Remotecontroller
holder
Tapping
screws
(small,
accessories)
(1)Set
Remote
controller
(2)Down
9319357003-05_IM.indb 8 10/20/2017 15:58:34
En-9
12.2. Installation work
12.2.1. Removing intake grille and front panel
(Referto9.1.intakegrilleremovaland9.3.frontpanelremoval)
12.2.2. Removing control cover, connector and control box
Screw1
Screw2
Controlcover
Groundwire(Green)
Controlbox
Screw3
CN5(Whiteconnector)
CN4(Redconnector)
CN14*1.
(Whiteconnector)
CN7
(Whiteconnector)
Connectorwires
(CN4,CN5,CN7,CN14)
(1)Removethescrew1thenremovethecontrolcover.
(2)Removetheconnectorwires.
*1.WhenthereisCN14connector,pullitout.
(3)Removetheconnectingcablesandthescrew2and3,thenremovethecontrolbox.
12.2.3. Installing relay control board and relay wire terminal
Controlunitboard
Connector(CN8)
Relaywire
Notice*2.
Clasp
Connector(CND01)
Relaycontrolboard
Clasps
*2.Notice the installingdirection
oftherelaycontrolboard.(The
elevationofthecontrolboxis
fit for therecess of the relay
controlboard.)
(1)Inserttherelaycontrolboardtoward2clasps.
(2)Thensettheboardwiththeclasp.
(3)Connecttherelaywireterminaltotheconnector(CND01)ontherelaycontrolboard.
(4)Connecttherelaywireterminaltotheconnector(CN8)onthecontrolunitboard.
CAUTION
Becarefulnottodamagethepartsontheboard.
Otherwise,itwillcausemalfunction.
12.2.4. Installing option kit
Remote controller cord modication
(1)Useatooltocutofftheterminalontheendoftheremotecontrollercord,andthen
removetheinsulationfromthecutendofthecord.
(2)Connecttheremotecontrollercordandconnectingcord.
(Suppliedwithwiredremotecontroller.)
Important:Besuretoinsulatetheconnectionbetweenthecords.
12.
OPTIONAL KIT INSTALLATION (UTY-TWBXF)
Thisairconditionercanbeconnectedwiththefollowingoptionalkits.
• Wiredremotecontroller
• Simpleremotecontroller
• Externalconnectkit
BEFORE INSTALL WIRED REMOTE CONTROLLER
• Whenyouusewiredremotecontroller,somefunctionsmaynotbeused.
CAUTION
Beforeinstalling,besuretodisconnectallpowersupply.
Don’ttouchtheheatexchanger.
Duringinstallingorremovingoperation,besurenottohavewirecaughtbypartsor
drawithard.Oritmayresulttroublestotheair-conditioner.
Avoidplaceindirectsunlight.
Selectplacethatwillnotbeaffectedbytheheatfromastove,etc
Beforesettinguptheoptionalkit,pleaseconrmwhetherair-conditionercanreceive
thesignal.
Donotconnectthewiredremotecontrollertotheterminalforpowersupply.
Whenconnectingthewiredremotecontrollerwiththeindoorunit,usetheconnecting
cable(suppliedwithwiredremotecontrollerorsimpleremotecontroller).
Recommendedcablelengthofwiredremotecontrolleris10m.Makesuretodoinsu-
lateofconnectingpartwhenextendedthecable.
Donotconnectpowersupplywiththeterminal.
INDOORUNIT
PCB
TERMINAL
12.1. Accessories (Communication kit)
Thefollowinginstallationaccessoriesaresupplied.Usethemasrequired.
Name and Shape
Q’ty
Description
Relaycontrolboard
1
Forconnectingthe
wiredremotecontrol
unitandexternal
connectwire.
Cabletie
1
Forxingthewires
fromcontrolbox.
Relaywire
1
Forconnectingthe
relaycontrolboardand
controlunitboard.
Wiringlabel
1
Fordisplaytheadditional
wiringdiagram.
9319357003-05_IM.indb 9 10/20/2017 15:58:55
En-10
13.
SELECTING THE REMOTE CONTROLLER CUSTOM CODE
Whentwoormoreairconditionersareinstalledinaroomandtheremotecontrolleris
operatinganairconditionerotherthantheoneyouwishtoset,changethecustomcode
oftheremotecontrollertooperateonlytheairconditioneryouwishtoset(4selections
possible).
Whentwoormoreairconditionersareinstalledinaroom,pleasecontactyourretailerto
settheindividualairconditionercustomcodes.
Selecting the Remote Controller Custom Code
Usethefollowingstepstoselectthecustomcodeoftheremotecontroller.(Notethatthe
airconditionercannotreceiveasignaliftheairconditionerhasnotbeensetforthematch-
ingcustomcode.)
(1) PresstheSTART/STOP(
)buttonuntilonlytheclock
isdisplayedontheremotecontrollerdisplay.
(2) PresstheMODEbuttonforatleast5secondstodisplay
thecurrentcustomcode(initiallysetto
).
(3) PresstheSETTEMP.(
/ )buttonstochangethe
customcodebetween
.
Matchthecodeonthedisplaytotheairconditioner
customcode.
(4) PresstheMODEbuttonagaintoreturntotheclock
display.Thecustomcodewillbechanged.
•Ifnobuttonsarepressedwithin30secondsafterthecustomcodeisdisplayed,the
systemreturnstotheoriginalclockdisplay.Inthiscase,startagainfromstep1.
•TheairconditionercustomcodeissettoApriortoshipment.
14. FUNCTION SETTING
Performthe“FUNCTIONSETTING”accordingtotheinstallationconditionsusingthe
remotecontroller.
CAUTION
Conrmwhetherthewiringworkforoutdoorunithasbeennished.
Conrmthatthecoverfortheelectricalenclosureontheoutdoorunitisinplace.
• Thisprocedurechangestothefunctionsettingsusedtocontroltheindoorunitaccording
totheinstallationconditions.Incorrectsettingscancausetheindoorunittomalfunction.
• Afterthepoweristurnedon,performthe“FUNCTIONSETTING”accordingtothe
installationconditionsusingtheremotecontroller.
• Thesettingsmaybeselectedbetweenthefollowingtwo:FunctionNumberorSettingValue.
• Settingswillnotbechangedifinvalidnumbersorsettingvaluesareselected.
• Refertotheinstallationmanualenclosedwiththeremotecontrolunitwhenthewired
remotecontrolunit(option)isused.
• Adjustthecustomcodeoftheindoorunitandthecustomcodeoftheremotecontroller.
Entering the Function Setting Mode
WhilepressingthePOWERFULbuttonandSETTEMP.( )simultaneously,pressthe
RESETbuttontoenterthefunctionsettingmode.
Selecting the Function Number and Setting Value
(1) Press the SETTEMP. ( / ) buttonsto select
thefunctionnumber.(Pressthe10°CHEATbutton
toswitchbetweentheleftandrightdigits.)
(2) PressthePOWERFULbuttontoproceedtosetting
thevalue. (PressthePOWERFULbuttonagainto
returntothefunctionnumberselection.)
(3) Press the SETTEMP. (
/ )buttons to select
thesettingvalue.(Pressthe 10°CHEATbuttonto
switchbetweentheleftandrightdigits.)
(4)
PresstheMODEbutton,intheorderlistedtoconrm
thesettings.
Pleaseconrmthatthebeepsounds.
(5) Next,pleasepressSTART/STOP(
)button.
Pleaseconrmthatthebeepsounds.
(6) PresstheRESETbuttontocancelthefunctionset-
tingmode.
(7) AftercompletingtheFUNCTIONSETTING,besuretodisconnectthepowerandre-
connectitagain.
CAUTION
Afterdisconnectingthepower,wait10secondsormorebeforereconnectingitagain.
TheFunctionSettingdoesnotbecomeactiveunlessthepowerisdisconnectedthen
reconnectedagain.
Function number
Setting
value
20mm
Remote
controllercord
Remote
controllercord
Red
Red
White
White
Black
Black
Insulated
connection
Connector
30mm
35~45mm
70~80mm
Installing the wired remote controller terminal (sold separately)
Connectthewiredremotecontrollerterminaltotheconnector
(CNC01)ontherelaycontrolboard.
Relaywire
Connector:CNC01
Wiredremote
controllercord
Rib
Installing the external connect kit terminal (sold separately)
Connectthewireofexternalinput/outputtotheboardofexternalconnectkit.
(
EXTERNALINPUTCONNECTTONO.CNA01
EXTERNALOUTPUTCONNECTTONO.CNB01,CNB02
)
External
connectkitcord
ErrorStatusOutput
connector:CNB02(Blackconnector)
OperationStatusOutput
connector:CNB01(Whiteconnector)
ControlInput
(Operation/StoporForcedstop)
connector:CNA01(Whiteconnector)
Rib
Fixing the wires
Afterconnectingtheterminals,threadthewiresthroughthenotchesandclasp
ofthecontrolboxascircledonthegurebelow.
Thenxthewiresontothecontrolboxwiththeprovidedcabletie.
Relaycontrolboard
Cabletie
12.2.5.
Installing the control box, connector and the control cover
(1) Attachthecontrolboxtotheindoorunit.
(2) Connecttheconnectorwires.
(3)
Attachthecontrolcover.
(4)
Attachthe3screws.Screw2isthescrewwhichinstallsthegroundwire.
12.2.6.
Labelling
Pastethewiringlabelbesidethelabelforschematicdiagraminsidethefrontpanel.
12.2.7. Installing the front panel and intake grille
(Referto9.2.intakegrilleinstallationand9.4.frontpanelinstallation)
9319357003-05_IM.indb 10 10/20/2017 15:58:58
En-11
Remote controller custom code
ChangetheindoorunitCustomCode,dependingontheremotecontrollers.
(♦...Factorysetting)
Setting Description
Function
Number
Setting Value
A
44
00
B 01
C 02
D 03
External input control
“Operation/Stop”modeor“Forcedstop”modecanbeelected.
(♦...Factorysetting)
Setting Description
Function
Number
Setting Value
Operation/Stopmode
46
00
(Settingforbidden) 01
Forcedstopmode 02
Setting record
Recordanychangestothesettingsinthefollowingtable.
Setting Description Setting Value
Filtersign
Coolerroomtemperaturecorrection
Heaterroomtemperaturecorrection
Autorestart
Indoorroomtemperaturesensorswitchingfunction
Remotecontrollercustomcode
Externalinputcontrol
AftercompletingtheFUNCTIONSETTING,besuretodisconnectthepowerandrecon-
nectitagain.
15. CUSTOMER GUIDANCE
Explainthefollowingtothecustomerinaccordancewiththeoperatingmanual:
(1)Starting and stopping method, operation switching, temperature adjustment, timer,
airowswitching,andotherremotecontrolunitoperations.
(2)Airlterremovalandcleaning,andhowtousetheairlouvers.
(3)Givetheoperatingmanualtothecustomer.
16. ERROR CODES
Ifyouuseawirelessremotecontroller,thelamponthephotodetectorunitwilloutputer-
rorcodesbywayofblinkingpatterns.Ifyouuseawiredremotecontroller,errorcodeswill
appearontheremotecontrollerdisplay.Seethelampblinkingpatternsanderrorcodesin
thetable.Anerrordisplayisdisplayedonlyduringoperation.
Error display
Wired
remote
controller
Error code
Description
OPERATION
lamp
(green)
TIMER
lamp
(orange)
ECONOMY
lamp
(green)
(1)
(1)
Serialcommunicationerror
(1)
(2)
Wiredremotecontroller
communicationerror
(1)
(5)
Checkrununfinished
(2)
(1)
UnitnumberorRefrigerantcircuit
addresssettingerror[Simultane-
ousMulti]
(2)
(2)
Indoorunitcapacityerror
(2)
(3)
Combinationerror
Filter Sign
Theindoorunithasasigntoinformtheuserthatitistimetocleanthelter.Selectthe
timesettingfortheltersigndisplayintervalinthetablebelowaccordingtotheamountof
dustordebrisintheroom.Ifyoudonotwishtheltersigntobedisplayed,selecttheset-
tingvaluefor“Noindication”.
(♦...Factorysetting)
Setting Description
Function
Number
Setting Value
Standard(400hours)
11
00
Longinterval(1,000hours) 01
Shortinterval(200hours) 02
Noindication 03
Cooling Room Temperature Correction
Dependingontheinstalledenvironment,theroomtemperaturesensormayrequireacor-
rection.
Thesettingsmaybeselectedasshowninthetablebelow.
(♦...Factorysetting)
Setting Description
Function
Number
Setting Value
Standard
30
00
Slightlylowercontrol 01
Lowercontrol 02
Warmercontrol 03
Heating Room Temperature Correction
Dependingontheinstalledenvironment,theroomtemperaturesensormayrequireacor-
rection.
Thesettingsmaybechangedasshowninthetablebelow.
(♦...Factorysetting)
Setting Description
Function
Number
Setting Value
Standard
31
00
Lowercontrol 01
Slightlywarmercontrol 02
Warmercontrol 03
Auto Restart
Enableordisableautomaticsystemrestartafterapoweroutage.
(♦...Factorysetting)
Setting Description
Function
Number
Setting Value
Yes
40
00
No 01
*Autorestartisanemergencyfunctionsuchasforpowerfailureetc.Donotstartandstop
theindoorunitbythisfunctioninnormaloperation.Besuretooperatebythecontrolunit,
orexternalinputdevice.
Indoor room temperature sensor switching function
(Onlyforwiredremotecontroller)
The following settings are needed when using the wired remote controller temperature
sensor.
(♦...Factorysetting)
Setting Description
Function
Number
Setting Value
No
42
00
Yes 01
*Ifsettingvalueis“00”:
Roomtemperatureiscontrolledbytheindoorunittemperaturesensor.
*Ifsettingvalueis“01”:
Roomtemperatureiscontrolledbyeitherindoorunittemperaturesensororremotecon-
trollerunitsensor.
9319357003-05_IM.indb 11 10/20/2017 15:59:00
En-12
Error display
Wired
remote
controller
Error code
Description
OPERATION
lamp
(green)
TIMER
lamp
(orange)
ECONOMY
lamp
(green)
(2)
(4)
•Connectionunitnumbererror
(indoorslaveunit)[Simultane-
ousMulti]
•Connectionunitnumbererror
(indoorunitorbranchunit)
[FlexibleMulti]
(2)
(7)
Primaryunit,secondaryunitset-
uperror[SimultaneousMulti]
(3)
(2)
IndoorunitPCBmodel
informationerror
(3)
(5)
Manualautoswitcherror
(4)
(1)
Roomtemp.sensorerror
(4)
(2)
IndoorunitHeatEx.Middletemp.
sensorerror
(5)
(1)
Indoorunitfanmotorerror
(5)
(3)
Drainpumperror
(5)
(7)
Dampererror
(5)
(8)
Intakegrilleerror
(5)
(15)
Indooruniterror
(6)
(2)
OutdoorunitmainPCBmodel
informationerroror
communicationerror
(6)
(3)
Invertererror
(6)
(4)
Activefiltererror,PFCcircuiter-
ror
(6)
(5)
TripterminalLerror
(6)
(10)
DisplayPCBmicrocomputers
communicationerror
(7)
(1)
Dischargetemp.sensorerror
(7)
(2)
Compressortemp.sensorerror
(7)
(3)
OutdoorunitHeatEx.liquid
temp.sensorerror
(7)
(4)
Outdoortemp.sensorerror
(7)
(5)
SuctionGastemp.sensorerror
(7)
(6)
•2-wayvalvetemp.sensorerror
•3-wayvalvetemp.sensorerror
(7)
(7)
Heatsinktemp.sensorerror
(8)
(2)
•Sub-coolHeatEx.gasinlet
temp.sensorerror
•Sub-coolHeatEx.gasoutlet
temp.sensorerror
(8)
(3)
Liquidpipetemp.sensorerror
(8)
(4)
Currentsensorerror
(8)
(6)
•Dischargepressuresensor
error
•Suctionpressuresensorerror
•Highpressureswitcherror
(9)
(4)
Tripdetection
Error display
Wired
remote
controller
Error code
Description
OPERATION
lamp
(green)
TIMER
lamp
(orange)
ECONOMY
lamp
(green)
(9)
(5)
Compressorrotorposition
detectionerror
(9)
(7)
Outdoorunitfanmotorerror
(9)
(9)
4-wayvalveerror
(10)
(1)
Dischargetemp.error
(10)
(3)
Compressortemp.error
(10)
(4)
Highpressureerror
(10)
(5)
Lowpressureerror
(13)
(2)
Branchboxeserror
[FlexibleMulti]
Displaymode
:0.5sON/0.5sOFF
:0.1sON/0.1sOFF
():Numberofflashing
[Troubleshooting with the indoor unit display]
OPERATIONindicatorlamp(green)
TIMERindicatorlamp(orange)
ECONOMYindicatorlamp(green)
[Troubleshooting with the wired remote controller display (Option)]
Ifan error occurs, the following display willbeshown. (“Er” will appear in the setroom
temperaturedisplay.)
Errorcode
9319357003-05_IM.indb 12 10/20/2017 15:59:05
/