Simplicity PORTABLE GENERATOR, BRIGGS & STRATTON, 3000, 030617-00 User manual

Category
Power generators
Type
User manual

This manual is also suitable for

Not for
Reproduction
BRIGGS & STRATTON POWER PRODUCTS GROUP, LLC
MILWAUKEE, WISCONSIN, U.S.A.
Manual No. 80007316 Revision -
Portable Generator
Operator’s Manual
This generator is rated in accordance with CSA (Canadian Standards Association) standard C22.2 No. 100-04 (motors and generators).
Not for
Reproduction
2 BRIGGSandSTRATTON.COM
H
K
B
L
D
C
G
3
N
A
F
E
2
A
D
A
B
C
G
E
F
1
P
J
M
R
Not for
Reproduction
3 3
7
A
B
4
C
9
A
8
B
A
C
5
A
B
C
6
C
A
B
D
E
Not for
Reproduction
4 BRIGGSandSTRATTON.COM
Thank you for purchasing this quality-built Briggs & Stratton® generator. We are pleased that you’ve placed your confidence in the Briggs & Stratton brand. When
operated and maintained according to the instructions in this manual, your Briggs & Stratton generator will provide many years of dependable service.
This manual contains safety information to make you aware of the hazards and risks associated with generators and how to avoid them. This generator is designed
and intended only for supplying electrical power for operating compatible electrical lighting, appliances, tools and motor loads, and is not intended for any other
purpose. It is important that you read and understand these instructions thoroughly before attempting to start or operate this equipment. Save these original
instructions for future reference.
This generator requires final assembly before use. Refer to the Assembly section of this manual for instructions on final assembly procedures. Follow the
instructions completely.
Where to Find Us
You never have to look far to find Briggs & Stratton support and service for your generator. There are thousands of Briggs & Stratton authorized service
dealers worldwide who provide quality service. You can also find the nearest Authorized Service Dealer in our dealer locator map on the Internet at
BRIGGSandSTRATTON.COM.
Copyright © 2013 Briggs & Stratton Power Products Group, LLC
Milwaukee, WI, USA. All rights reserved.
BRIGGS & STRATTON POWER PRODUCTS is a registered
trademark of Briggs & Stratton Corporation
Milwaukee, WI, USA
ORIGINAL INSTRUCTIONS
Generator
Model Number
Revision
Serial Number
Date Purchased
Engine
Model Number
Type Number
Code Number
Table of Contents
Safe Operation Checklist............................. 5
Operator Safety .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. 6
Equipment Description............................................6
Important Safety Information . . .. . . .. . . .. . . .. . . .. . . .. . . .. . . .. . . .. . . 6
Assembly .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. 8
Unpack Generator................................................8
Install Wheel Kit. . .. . . .. . . .. . . .. . . .. . . .. . . .. . . .. . . .. . . .. . . .. . . .. . . 8
Add Engine Oil. . . .. . . .. . . .. . . .. . . .. . . .. . . .. . . .. . . .. . . .. . . .. . . .. . . 8
Add Fuel. .. . . .. . . .. . . .. . . .. . . .. . . .. . . .. . . .. . . .. . . .. . . .. . . .. . . .. . . 8
System Ground ..................................................8
Connecting to a Building’s Electrical System .......................8
Generator Location ..............................................8
Features and Controls ..............................11
Ground Fault Protection .........................................11
Operation .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . . 12
Starting the Engine ..............................................12
Connecting Electrical Loads .....................................12
Stopping the Engine. . .. . . .. . . .. . . .. . . .. . . .. . . .. . . .. . . .. . . .. . . .. . 12
Don’t Overload Generator. .. . . .. . . .. . . .. . . .. . . .. . . .. . . .. . . .. . . .. . 13
Maintenance .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . . 14
Maintenance Schedule ..........................................14
Generator Maintenance .........................................14
Fuel Valve Maintenance . . .. . . .. . . .. . . .. . . .. . . .. . . .. . . .. . . .. . . .. . 14
Engine Maintenance . .. . . .. . . .. . . .. . . .. . . .. . . .. . . .. . . .. . . .. . . .. . 15
Storage. . .. . . .. . . .. . . .. . . .. . . .. . . .. . . .. . . .. . . .. . . .. . . .. . . .. . . .. . 16
Troubleshooting.....................................17
Product Specifications ..............................17
Common Service Parts .............................17
Warranties ..........................................18
Generator Owner Warranty ......................................18
Not for
Reproduction
5
Safe Operation Checklist
Safe operation of the portable generator requires the completion of the following tasks:
Carbon Monoxide (CO) Alarm
Carbon monoxide (CO) alarm(s) in working order.
Smoke Alarm
Smoke alarm(s) in working order.
Generator Location
Generator placed in a Carbon Monoxide (CO) safe zone. See Generator Location to reduce the Risk of Carbon Monoxide Poisoning.
Generator placed in a fire safe zone. See Generator Location to reduce the Risk of Fire.
Generator located on flat and level surface.
Oil and Fuel
Engine oil filled to proper level. See Add Engine Oil.
Fuel tank filled at or below the red fuel level indicator. See Add Fuel.
Inspect fuel lines, tank, cap and fittings each time before using generator. DO NOT use if fuel leak or damage is found.
Electrical
When connecting to a buildings electrical system install listed transfer equipment. See Connecting to a Building’s Electrical System.
Electrical cords are rated for intended loads. See Cord Sets and Receptacles.
Electrical cords do not run through doorways, windows, holes in ceilings, walls or floors. Inspect electrical cords thoroughly before each use. DO NOT use if
damaged.
All labeled electrical cord safeties are understood and being followed.
Operation
Start engine. See Starting the Engine.
Not for
Reproduction
6 BRIGGSandSTRATTON.COM
Operator Safety
Equipment Description
Read this manual carefully and become familiar with your
generator. Know its applications, its limitations and any
hazards involved.
The generator is an engine–driven, revolving field, alternating current (AC)
generator. It was designed to supply electrical power for operating compatible
electrical lighting, appliances, tools and motor loads. The generator’s revolving
field is driven at about 3,000 rpm by a single-cylinder engine.
Every effort has been made to ensure that the information in this manual is both
accurate and current. However, the manufacturer reserves the right to change,
alter or otherwise improve the generator and this documentation at any time
without prior notice.
Important Safety Information
The manufacturer cannot possibly anticipate every possible circumstance that
might involve a hazard. The warnings in this manual, and the tags and decals
affixed to the unit are, therefore, not all-inclusive. If you use a procedure, work
method or operating technique that the manufacturer does not specifically
recommend, you must satisfy yourself that it is safe for you and others. You must
also make sure that the procedure, work method or operating technique that you
choose does not render the generator unsafe.
Safety and Control Symbols
The safety alert symbol indicates a potential personal injury hazard. A
signal word (DANGER, WARNING, or CAUTION) is used with the alert
symbol to designate a degree or level of hazard seriousness. A safety symbol
may be used to represent the type of hazard. The signal word NOTICE is used
to address practices not related to personal injury.
DANGER indicates a hazard which, if not avoided, will result in death or
serious injury.
WARNING indicates a hazard which, if not avoided, could result in death
or serious injury.
CAUTION indicates a hazard which, if not avoided, could result in minor
or moderate injury.
NOTICE address practices not related to personal injury.
WARNING Starter cord kickback (rapid retraction) will pull hand and
arm toward engine faster than you can let go which could cause
broken bones, fractures, bruises, or sprains resulting in serious
injury.
When starting engine, pull cord slowly until resistance is felt and then pull
rapidly to avoid kickback.
NEVER start or stop engine with electrical devices plugged in and turned
on.
WARNING
Generator voltage could cause electrical shock or burn
resulting in death or serious injury.
Use approved transfer equipment to prevent backfeed by
isolating generator from electric utility workers.
When using generator for backup power, notify utility company.
DO NOT connect generator to a building’s electrical system.
Use a residual current circuit breaker with overload protection device
(RCBO) in any damp or highly conductive area, such as metal decking or
steel work.
DO NOT touch bare wires or receptacles.
DO NOT use generator with electrical cords which are worn, frayed, bare
or otherwise damaged.
DO NOT operate generator in the rain or wet weather.
DO NOT handle generator or electrical cords while standing in water,
while barefoot, or while hands or feet are wet.
DO NOT allow unqualified persons or children to operate or service
generator.
Suffocation
Fire
Toxic Fumes
Explosion
Electrical
Shock
Kickback
Suffocation
Operator’s
Manual
Moving Parts Flying Objects
Hot Surface
Heavy Objects
Carbon
Monoxide Alarm
Alarm Bonded to
Ground
Ground
Terminal
Choke Run
Off On
Volt Meter Oil Level Fuel Start
Circuit Breaker Engine Control Do Not Start
Engine
!
WARNING POISONOUS GAS HAZARD. Engine exhaust contains
carbon monoxide, a poisonous gas that could kill you in minutes.
You CANNOT see it, smell it, or taste it. Even if you do not smell
exhaust fumes, you could still be exposed to carbon monoxide
gas. If you start to feel sick, dizzy or weak while using this product, shut it off
and get to fresh air RIGHT AWAY. See a doctor. You may have carbon
monoxide poisoning.
Operate this product ONLY outside far away from windows, doors and
vents to reduce the risk of carbon monoxide gas from accumulating and
potentially being drawn towards occupied spaces.
Install battery-operated carbon monoxide alarms or plug-in carbon
monoxide alarms with battery back-up according to the manufacturer’s
instructions. Smoke alarms cannot detect carbon monoxide gas.
DO NOT run this product inside homes, garages, basements,
crawlspaces, sheds, or other partially-enclosed spaces even if using fans
or opening doors and windows for ventilation. Carbon monoxide can
quickly build up in these spaces and can linger for hours, even after the
product has shut off.
ALWAYS place this product downwind and point the engine exhaust away
from occupied spaces.
Not for
Reproduction
7
NOTICE
Exceeding generators wattage/amperage capacity could damage
generator and/or electrical devices connected to it.
DO NOT exceed the generator’s wattage/amperage capacity. See Don’t
Overload Generator in the Operation section.
Start generator and let engine stabilize before connecting electrical loads.
Connect electrical loads in OFF position, then turn ON for operation.
Turn electrical loads OFF and disconnect from generator before stopping
generator.
NOTICE
Improper treatment of generator could damage it and shorten its
life.
Use generator only for intended uses.
If you have questions about intended use, ask dealer or contact local service
center.
Operate generator only on level surfaces.
DO NOT expose generator to excessive moisture, dust, dirt, or corrosive
vapors.
DO NOT insert any objects through cooling slots.
If connected devices overheat, turn them off and disconnect them from
generator.
Shut off generator if:
-electrical output is lost;
-equipment sparks, smokes, or emits flames;
-unit vibrates excessively.
WARNING Fuel and its vapors are extremely flammable and
explosive which could cause burns, fire or explosion
resulting in death or serious injury.
WHEN ADDING OR DRAINING FUEL
Turn generator engine OFF and let it cool at least 2 minutes before
removing fuel cap. Loosen cap slowly to relieve pressure in tank.
Fill or drain fuel tank outdoors.
DO NOT overfill tank. Allow space for fuel expansion.
If fuel spills, wait until it evaporates before starting engine.
Keep fuel away from sparks, open flames, pilot lights, heat, and other
ignition sources.
Check fuel lines, tank, cap and fittings frequently for cracks or leaks.
Replace if necessary.
DO NOT light a cigarette or smoke.
WHEN STARTING EQUIPMENT
Ensure spark plug, muffler, fuel cap, and air cleaner are in place.
DO NOT crank engine with spark plug removed.
WHEN OPERATING EQUIPMENT
DO NOT operate this product inside any building, carport, porch, mobile
equipment, marine applications, or enclosure.
DO NOT tip engine or equipment at angle which causes fuel to spill.
DO NOT stop engine by moving choke control to “Choke” position (
).
WHEN TRANSPORTING, MOVING OR REPAIRING EQUIPMENT
Transport/move/repair with fuel tank EMPTY or with fuel shutoff valve
OFF.
DO NOT tip engine or equipment at angle which causes fuel to spill.
Disconnect spark plug wire.
WHEN STORING FUEL OR EQUIPMENT WITH FUEL IN TANK
Store away from furnaces, stoves, water heaters, clothes dryers, or other
appliances that have pilot light or other ignition source because they could
ignite fuel vapors.
WARNING Exhaust heat/gases could ignite combustibles, structures
or damage fuel tank causing a fire, resulting in death or
serious injury.
Contact with muffler area could cause burns resulting in
serious injury.
DO NOT touch hot parts and AVOID hot exhaust gases.
Allow equipment to cool before touching.
Keep at least 1.5 m (5 ft.) of clearance on all sides of generator including
overhead.
Contact the original equipment manufacturer, retailer, or dealer to obtain
a spark arrester designed for the exhaust system installed on this engine.
Replacement parts must be the same and installed in the same position
as the original parts.
WARNING Unintentional sparking could cause fire or electric shock
resulting in death or serious injury.
WHEN ADJUSTING OR MAKING REPAIRS TO YOUR GENERATOR
Disconnect the spark plug wire from the spark plug and place the wire
where it cannot contact spark plug.
WHEN TESTING FOR ENGINE SPARK
Use approved spark plug tester.
DO NOT check for spark with spark plug removed.
WARNING Starter and other rotating parts could entangle hands,
hair, clothing, or accessories resulting in serious injury.
NEVER operate generator without protective housing or covers.
DO NOT wear loose clothing, jewelry or anything that could be caught in
the starter or other rotating parts.
Tie up long hair and remove jewelry.
CAUTION Excessively high operating speeds could result in minor
injury.
Excessively low speeds impose a heavy load.
DO NOT tamper with governor spring, links or other parts to increase
engine speed.
DO NOT modify generator in any way.
Not for
Reproduction
8 BRIGGSandSTRATTON.COM
Assembly
Your generator is ready for use after it has been properly serviced with the
recommended petrol and oil.
If you have any problems with the servicing of your generator, contact your local
Briggs & Stratton service center. If you need assistance, please have the model,
revision, and serial number from the identification label available. See Features
and Controls for identification label location.
Unpack Generator
1. Set the carton on a rigid, flat surface.
2. Remove everything from carton.
The generator is supplied with:
Operator’s manual
Wheel kit
Bottle of engine oil
Install Wheel Kit Figure
1
NOTICE Wheel kit is not intended for over-the-road use.
Install the wheel kit as follows:
1. Tip generator so that engine end is up.
2. Slide a washer (A) over axle stud (B).
3. Slide a wheel (C) over axle stud (B).
NOTICE Be sure to install wheel with raised hub inboard.
4. Slide axle stud (B) through mounting bracket.
5. Insert retaining pin (D) through hole on axle stud.
6. Repeat steps 2 thru 5 to secure second wheel.
7. Line up holes in support leg (E) with holes in generator frame.
8. Attach support leg using four capscrews (F) and four flange nuts (G).
Tighten with 10 and 13 mm wrenches.
9. Return generator to normal operating position (resting on wheels and
support leg).
Add Engine Oil
1. Place generator on a level surface.
2. Add engine oil as described in Adding Engine Oil of the Engine
Maintenance section.
NOTICE
Improper treatment of generator could damage it and shorten its life.
DO NOT attempt to crank or start the engine before it has been properly
serviced with the recommended oil. This could result in an engine failure.
Add Fuel Figure
2
Fuel must meet these requirements:
Clean, fresh, unleaded petrol.
A minimum of 87 octane/87 AKI (91 RON). For high altitude use, see High
Altitude.
Petrol with up to 10% ethanol (gasohol) is acceptable.
NOTICE Use of unapproved fuels will damage the engine components and
void the engine warranty.
DO NOT use unapproved petrol, such as E15 and E85.
DO NOT mix oil in petrol or modify the engine to run on alternate fuels.
To protect the fuel system from gum formation, mix in a fuel stabilizer when
adding fuel. See Storage. All fuel is not the same. If you experience starting
or performance problems after using fuel, switch to a different fuel provider
or change brands. This engine is certified to operate on petrol. The emission
control system for this engine is EM (Engine Modifications).
1. Clean area around fuel fill cap, remove cap.
2. Slowly add unleaded fuel to fuel tank. Be careful not to fill above the red
fuel level indicator (A). This allows adequate space for fuel expansion
as shown.
3. Install fuel cap and let any spilled fuel evaporate before starting engine.
High Altitude
At altitudes over 1500 meters (5,000 feet), a minimum 85 octane / 85 AKI
(89 RON) petrol is acceptable. To remain emissions compliant, high altitude
adjustment is required. Operation without this adjustment will cause decreased
performance, increased fuel consumption, and increased emissions. See a
Briggs & Stratton authorized dealer for high altitude adjustment information.
Operation of the engine at altitudes below 750 meters (2,500 feet) with the
high altitude kit is not recommended.
System Ground
The generator is provided with a grounding fastener. The generator has a
system ground that connects the generator frame components to the ground
terminals on the AC output receptacles. The system ground is connected to
the AC neutral wire (the neutral is bonded to the generator frame).
Special Requirements
There may be Federal, local codes, or ordinances that apply to the intended
use of the generator. Please consult a qualified electrician, electrical inspector,
or the local agency having jurisdiction:
In some areas, generators are required to be registered with local utility
companies.
If the generator is used at a construction site, there may be additional
regulations which must be observed.
Connecting to a Building’s Electrical System
Connections for standby power to a building’s electrical system must use a
listed transfer switch installed by a current licensed electrician. The connection
must isolate the generator power from the utility power and must comply with
all applicable laws and electrical codes.
Generator Location
Before starting the portable generator there are two equally important safety
concerns regarding carbon monoxide (CO) poisoning and fire that must be
addressed.
NOTICE Satisfying the RISK OF CARBON MONOXIDE POISONING location
requirements may not satisfy the fire location requirements. Satisfying
the RISK OF FIRE location requirements may not satisfy the CARBON
MONOXIDE POISONING location requirements.
Operation Location of Portable Generator to REDUCE THE RISK OF
CARBON MONOXIDE POISONING
All fossil fuel burning equipment, such as a portable generator, contains
carbon monoxide (CO) gas in the engine exhaust, a poisonous gas that could
kill you in minutes. You CANNOT smell it, see it, or taste it. Even if you do not
smell exhaust fumes, you could still be exposed to carbon monoxide gas. The
following must be completed prior to starting the portable generator engine:
WARNING
Generator voltage could cause electrical shock or burn
resulting in death or serious injury.
Use approved transfer equipment to prevent backfeed by isolating
generator from electric utility workers.
When using generator for backup power, notify utility company.
DO NOT connect generator to a building’s electrical system.
Use a residual current circuit breaker with overload protection device
(RCBO) in any damp or highly conductive area, such as metal decking or
steel work.
DO NOT touch bare wires or receptacles.
DO NOT use generator with electrical cords which are worn, frayed, bare
or otherwise damaged.
DO NOT operate generator in the rain or wet weather.
DO NOT handle generator or electrical cords while standing in water,
while barefoot, or while hands or feet are wet.
DO NOT allow unqualified persons or children to operate or service
generator.
WARNING Fuel and its vapors are extremely flammable and explosive
which could cause burns, fire or explosion resulting in
death or serious injury.
WHEN ADDING FUEL
Turn generator engine OFF and let it cool at least 2 minutes before removing
fuel cap. Loosen cap slowly to relieve pressure in tank.
Fill fuel tank outdoors.
DO NOT overfill tank. Allow space for fuel expansion.
If fuel spills, wait until it evaporates before starting engine.
Keep fuel away from sparks, open flames, pilot lights, heat, and other
ignition sources.
Check fuel lines, tank, cap and fittings frequently for cracks or leaks.
Replace if necessary.
DO NOT light a cigarette or smoke.
Not for
Reproduction
9
By law it is required in many states to have a Carbon Monoxide (CO)
alarm (A) in operating condition in your home. Install/maintain battery-
operated carbon monoxide alarms or plug-in carbon monoxide alarms
with battery back-up according to the manufacturer’s instructions. A CO
alarm is an electronic device that detects hazardous levels of CO. When
there is a buildup of CO, the alarm will alert the occupants by flashing
visual indicator light and alarm. Smoke alarms cannot detect CO gas.
Operate this product ONLY outside far away from windows, doors and
vents to reduce the risk of carbon monoxide gas from accumulating and
potentially being drawn towards occupied spaces.
DO NOT run this product inside homes, garages, basements,
crawlspaces, sheds, or other partially enclosed spaces even if using
fans or opening doors and windows for ventilation. Carbon monoxide
can quickly build up in these spaces and can linger for hours, even after
this product has shut off.
Your neighbor(s) home may be exposed to the engine exhaust from
your portable generator and must be considered when deciding on a
location for the safe operation of your portable generator.
ALWAYS place this product downwind and point the engine exhaust
away from occupied spaces.
If you start to feel sick, dizzy, or weak while using this product, shut it off and
get to fresh air RIGHT AWAY. See a doctor. You may have carbon monoxide
poisoning.
EXAMPLE OF LOCATION TO REDUCE THE RISK OF CARBON MONOXIDE POISONING
Only use OUTSIDE and FAR
AWAY from windows, doors
and vents.
Direct exhaust AWAY
from windows, doors,
and vents.
KEEP
FAR AWAY
CO Alarm
in Living Areas
E
X
H
A
U
S
T
(
C
O
)
DO NOT OPERATE IN ANY OF THE FOLLOWING LOCATIONS
Generator too
close to home and
exhaust directed
towards windows,
doors and vents.
Garage
Attic
Living Area
Basement
Crawlspace
Entryway,
Porch
E
X
H
A
U
S
T
(
C
O
)
Not for
Reproduction
10 BRIGGSandSTRATTON.COM
EXAMPLE OF LOCATION TO REDUCE THE RISK OF FIRE
Direct exhaust AWAY from
windows, doors, and vents.
E
X
H
A
U
S
T
(
C
O
)
(1.5 m) 5 ft. min.
1.5m (5 ft.) min.
OPERATION LOCATION OF PORTABLE GENERATOR TO REDUCE
THE RISK OF FIRE
WARNING Exhaust heat/gases could ignite combustibles, structures
or damage fuel tank causing a fire, resulting in death or serious
injury.
Portable generator must be at least 1.5 m (5 feet) from any structure,
overhang, trees, windows, doors, any wall opening, shrubs, or vegetation
over 30.5cm (12 inches)in height.
DO NOT place portable generator under a deck or other type of structure
that may confine airflow.
Smoke alarm(s) MUST be installed and maintained indoors according
to the manufacturer’s instructions/recommendations. Carbon monoxide
alarms cannot detect smoke.
DO NOT place portable generator in manner other than shown.
Not for
Reproduction
11
Features and Controls Figure
3
Read this Operator’s Manual and safety rules before operating
your generator. Compare the illustrations with your generator, to
familiarize yourself with the locations of various controls and
adjustments. Save this manual for future reference.
A - ON/OFF Switch — Set this switch to on (I) before starting engine. Set
switch to off (0) to shut off engine.
B - Circuit Breakers(DC) — The receptacle is provided with circuit breakers
to protect the 12 Volt DC receptacle against electrical overload.
C - 12 Volt DC Receptacle Use this receptacle for devices that are
equipped with automotive-type plugs. The maximum current output is 5 Amps.
D - Residual Current Breaker with Overload Protection Device A residual
current breaker with overload protection device (RCBO) is provided to
protect against electrical ground fault and protect the generator against
electrical overload.
E - 230 Volt AC Outlets — May be used to supply electrical power for the
operation of 230 Volt AC, single phase, 50 Hz electrical, lighting, appliance,
tool, and motor loads.
F - Oil Fill Cap — Check and add engine oil here.
G - Oil Drain Plug — Drain engine oil here.
H - Grounding Fastener — Consult your local agency having
jurisdiction for grounding requirements in your area.
J - Identification Label — Provides model and serial number of generator.
Please have these readily available if calling for assistance.
K - Spark Arrester Muffler — Exhaust muffler lowers engine noise and is
equipped with a spark arrester screen.
L - Air Cleaner — Protects engine by filtering dust and debris out of intake air.
M - Recoil Starter — Used to start the engine manually.
N - Choke Lever — Used when starting a cold engine.
P - Fuel Valve — Used to turn fuel supply on and off to engine.
R - Fuel Tank — Capacity of 15 liters (4.0 U.S. gallons).
Items Not Shown:
Engine Identification — Provides model, type and code of engine. Please
have these readily available if calling for assistance.
Ground Fault Protection
This unit is equipped with a residual current breaker with overload protection
device (RCBO). This device meets applicable federal, state and local codes.
The RCBO protects against electrical shock that may be caused if your body
becomes a path which electricity travels to reach ground. This could happen
if you touch a “Live” appliance or wire, or are touching plumbing or other
materials that connect to the ground.
When protected by a RCBO, one may still feel a shock, but the RCBO should
cut current off quickly enough so that a person in normal health should not
suffer any serious electrical injury.
Test RCBO
Test your RCBO circuit breaker every month, as follows:
1. While generator is running, push Test (T) button. The circuit breaker
should trip (handle will move to approximate center position), which will
disconnect power to outlets.
NOTICE If circuit breaker does not trip:
DO NOT use generator.
Call a Briggs & Stratton Power Products service center.
2. If handle moves to center, reset circuit breaker by firmly moving handle
to Off or 0 (down) position, then to On or I (up) position.
NOTICE If circuit breaker does not reset properly:
DO NOT use generator.
Call a Briggs & Stratton Power Products service center.
During Generator Use
If circuit breaker trips during use, it usually indicates faulty electrical equipment
or cords. However, test the circuit breaker as follows;
1. Disconnect loads, reset and test circuit breaker as described earlier. Let
generator run without any loads for 1 minute.
NOTICE If circuit breaker trips in the 1 minute period:
DO NOT use generator.
Call a Briggs & Stratton Power Products service center.
2. If circuit breaker tests correctly, the electrical equipment or extension
cords may be faulty. Replace faulty electrical equipment and cords
before further use.
NOTICE If circuit breaker tests correctly:
Have qualified personnel check all electrical equipment and cords for any
defects.
Replace electrical equipment and cords or take to a qualified repair center.
WARNING Electric Shock Hazard could result in death or serious
injury.
The RCBO will not protect you against the following situations:
-Line-to-line shocks;
-Current overloads or line-to-line short circuits.
The fuse or circuit breaker at the control panel must provide such
protection.
WARNING Electric Shock Hazard could result in death or serious
injury.
DO NOT touch bare wires or receptacles.
DO NOT use generator with electrical cords which are worn, frayed, bare
or otherwise damaged.
DO NOT operate generator in the rain or wet weather.
DO NOT handle generator or electrical cords while standing in water,
while barefoot, or while hands or feet are wet.
DO NOT allow unqualified persons or children to operate or service
generator or electrical loads.
Not for
Reproduction
Operation
Starting the Engine Figure
3
Disconnect all electrical loads from the generator. Use the following start
instructions:
1. Make sure unit is on a flat, level surface.
NOTICE Failure to start and operate the unit on a flat, level surface will cause
the unit not to start or shut down during operation.
2. Turn fuel valve (3, P) to on position (I).
3. Move choke lever (3, N) to choke position (
).
4. Push on/off switch to on position (I), grasp recoil handle (3, M) and pull
slowly until slight resistance is felt. Then pull rapidly one time only to
start engine.
If engine starts, proceed to step 6.
If engine fails to start, proceed to step 5.
5. Move choke lever to half choke position and pull recoil handle twice.
If engine fails to start, repeat steps 3 thru 4.
6. Slowly move choke lever to run position ( ). If engine falters, move
choke lever to half choke position until engine runs smoothly, and then
to run position (
).
NOTICE If engine floods, place choke lever in run position (
) and crank
until engine starts.
NOTICE If engine starts after 3 pulls but fails to run, or if unit shuts down
during operation, make sure unit is on a level surface and check for proper oil
level in crankcase. This unit may be equipped with a low oil protection device.
If so, oil must be at proper level for engine to start.
Connecting Electrical Loads
Use only high quality, well-insulated extension cables with the generator’s
230 Volt AC outlets. Inspect extension cables before each use. Check that
all extension cables are suitably rated and are not damaged. Keep extension
cables as short as possible to minimize voltage drop.
1. Let engine stabilize and warm up for a few minutes after starting.
2. Plug in and turn on the desired 230 Volt AC, single phase, 50 Hz
electrical loads.
NOTICE
DO NOT connect 3-phase loads to the generator.
DO NOT connect 60 Hz loads to the generator.
DO NOT OVERLOAD THE GENERATOR. See Don’t Overload
Generator.
NOTICE Exceeding generators wattage/amperage capacity could damage
generator and/or electrical devices connected to it.
DO NOT exceed the generator’s wattage/amperage capacity. See Don’t
Overload Generator in the Operation section.
Start generator and let engine stabilize before connecting electrical loads.
Connect electrical loads in OFF position, then turn ON for operation.
Turn electrical loads OFF and disconnect from generator before stopping
generator.
Stopping the Engine
1. Turn OFF and unplug all electrical loads from generator panel
receptacles. NEVER start or stop engine with electrical devices plugged
in and turned ON.
2. Let engine run at no-load for several minutes to stabilize internal
temperatures of engine and generator.
3. Turn on/off switch to off (0) position.
4. Turn fuel valve to the off position (0).
WARNING Exhaust heat/gases could ignite combustibles, structures
or damage fuel tank causing a fire, resulting in death or
serious injury.
Contact with muffler area could cause burns resulting in
serious injury.
DO NOT touch hot parts and AVOID hot exhaust gases.
Allow equipment to cool before touching.
Keep at least 1.5 m (5 ft.) of clearance on all sides of generator including
overhead.
Contact the original equipment manufacturer, retailer, or dealer to obtain
a spark arrester designed for the exhaust system installed on this engine.
Replacement parts must be the same and installed in the same position
as the original parts.
WARNING
Generator voltage could cause electrical shock or burn
resulting in death or serious injury.
DO NOT connect generator to a building’s electrical system.
DO NOT touch bare wires or receptacles.
DO NOT use generator with electrical cords which are worn, frayed, bare
or otherwise damaged.
DO NOT operate generator in the rain or wet weather.
DO NOT handle generator or electrical cords while standing in water,
while barefoot, or while hands or feet are wet.
DO NOT allow unqualified persons or children to operate or service generator.
WARNING Damaged or overloaded electrical cables could overheat,
arc, and burn resulting in death or serious injury.
ONLY use suitably rated extension cables.
Follow all safety instructions on extension cables.
Inspect cables before each use.
WARNING Fuel and its vapors are extremely flammable and
explosive which could cause burns, fire or explosion
resulting in death or serious injury.
DO NOT stop engine by moving choke control to “Choke” position (
).
WARNING Starter cord kickback (rapid retraction) will pull hand and
arm toward engine faster than you can let go which could cause
broken bones, fractures, bruises, or sprains resulting in serious
injury.
When starting engine, pull cord slowly until resistance is felt and then pull
rapidly to avoid kickback.
NEVER start or stop engine with electrical devices plugged in and turned on.
12 BRIGGSandSTRATTON.COM
Not for
Reproduction
Don’t Overload Generator
Capacity
You must make sure your generator can supply enough rated (running) and surge
(starting) watts for the items you will power at the same time. Follow these simple
steps:
1. Select the items you will power at the same time.
2. Total the rated (running) watts of these items. This is the amount of
power your generator must produce to keep your items running. See
Wattage Reference Guide.
3. Estimate how many surge (starting) watts you will need. Surge wattage
is the short burst of power needed to start electric motor-driven tools or
appliances such as a circular saw or refrigerator. Because not all motors
start at the same time, total surge watts can be estimated by adding only
the item(s) with the highest additional surge watts to the total rated watts
from step 2.
Example:
Total Rated (Running) Watts = 2480
Highest Additional Surge Watts = 1800
Total Generator Output Required = 4280
Power Management
To prolong the life of your generator and attached devices, it is important to take
care when adding electrical loads to your generator. There should be nothing
connected to the generator outlets before starting its engine. The correct and
safe way to manage generator power is to sequentially add loads as follows:
1. With nothing connected to the generator, start the engine as described
in this manual.
2. Plug in and turn on the first load, preferably the largest load you have.
3. Permit the generator output to stabilize (engine runs smoothly and
attached device operates properly).
4. Plug in and turn on the next load.
5. Again, permit the generator to stabilize.
6. Repeat steps 4 and 5 for each additional load.
NEVER add more loads than the generator capacity. Take special care to
consider surge loads in generator capacity, as described above.
* Wattages listed are approximate only. Check tool or appliance for actual wattage.
Tool or Appliance
Rated (Running)
Watts
Additional Surge
(Starting) Watts
Window AC - 10,000 BTU 1200 1800
Deep Freezer 500 500
Television 500
Security System 180
Light (100 Watts) 100
2480 Total Running
Watts
1800 Highest Surge
Watts
Wattage Reference Guide
Tool or Appliance
Rated*
(Running)
Watts
Additional
Surge (Starting)
Watts
Essentials
Light Bulb - 100 watt 100
Deep Freezer 500 500
Sump Pump 800 1200
Refrigerator/Freezer - 18 cf 800 1600
Water Well Pump - 1/3 hp 1000 2000
Heating/Cooling
Window AC - 10,000 BTU 1200 1800
Window Fan 300 600
Furnace Fan Blower - 1/2 hp 800 1300
Kitchen
Microwave Oven - 1000 Watt 1000
Coffee Maker 1500
Electric Stove - Single Element 1500
Family Room
DVD/CD Player 100
VCR 100
Stereo Receiver 450
Color Television - 27 in 500
Personal Computer w/17 in monitor 800
Other
Security System 180
AM/FM Clock Radio 300
Garage Door Opener - 1/2 hp 480 520
DIY/Job Site
Quartz Halogen Work Light 1000
Airless Sprayer - 1/3 hp 600 1200
Reciprocating Saw 960 960
Electric Drill - 1/2 hp 1000 1000
Circular Saw - 7-1/4 in 1500 1500
13
Not for
Reproduction
Maintenance
Maintenance Schedule
Follow the hourly or calendar intervals, whichever occurs first. More frequent
service is required when operating in adverse conditions noted below.
¹
Service more often under dirty or dusty conditions.
General Recommendations
Regular maintenance will improve the performance and extend the life of the
generator.
See any authorized dealer for service.
The generator’s warranty does not cover items that have been subjected to
operator abuse or negligence. To receive full value from the warranty, the
operator must maintain the generator as instructed in this manual.
NOTICE
Improper treatment of generator could damage it and shorten its
life.
NEVER operate generator without protective housing or covers to assure
proper cooling.
Some adjustments will need to be made periodically to properly maintain your
generator.
All service and adjustments should be made at least once each season.
Follow the requirements in the Maintenance Schedule chart above.
NOTICE Once a year you should clean or replace the spark plug and replace
the air filter. A new spark plug and clean air filter assure proper fuel-air mixture
and help your engine run better and last longer.
Generator Maintenance
Generator maintenance consists of keeping the unit clean and dry. Operate
and store the unit in a clean dry environment where it will not be exposed to
excessive dust, dirt, moisture, or any corrosive vapors. Cooling air slots in the
generator must not become clogged with snow, leaves, or any other foreign
material.
NOTICE DO NOT use water or other liquids to clean generator. Liquids can
enter engine fuel system, causing poor performance and/or failure to occur. In
addition, if liquid enters generator through cooling air slots, some of the liquid
will be retained in voids and cracks of the rotor and stator winding insulation.
Liquid and dirt buildup on the generator internal windings will eventually
decrease the insulation resistance of these windings.
Cleaning
Daily or before use, look around and underneath the generator for signs of oil or
fuel leaks. Clean accumulated debris from inside and outside the generator. Keep
the linkage, spring and other engine controls clean. Keep the area around and
behind the muffler free from any combustible debris. Inspect cooling air slots and
openings on generator. These openings must be kept clean and unobstructed.
Engine parts should be kept clean to reduce the risk of overheating and
ignition of accumulated debris:
Use a damp cloth to wipe exterior surfaces clean.
NOTICE
Improper treatment of generator could damage it and shorten its
life.
DO NOT expose generator to excessive moisture, dust, dirt, or corrosive
vapors.
DO NOT insert any objects through cooling slots.
Use a soft bristle brush to loosen caked on dirt or oil.
Use a vacuum cleaner to pick up loose dirt and debris.
Fuel Valve Maintenance Figure
4
The fuel valve is equipped with a fuel sediment cup, screen, and o-ring that
need to be cleaned.
1. Move fuel valve to off (0) position.
2. Remove sediment cup (A) from fuel valve. Remove o-ring (B) and
screen (C) from fuel valve.
3. Wash sediment cup, o-ring, and screen in a nonflammable solvent. Dry
them thoroughly.
4. Place screen and o-ring into fuel valve. Install sediment cup and tighten
securely.
5. Move fuel valve to on (I) position, and check for leaks. Replace fuel
valve if there is any leakage.
First 5 Hours
Change engine oil
Every 8 Hours or Daily
Clean debris
Check engine oil level
Every 25 Hours or Yearly
Service engine air cleaner
1
Every 50 Hours or Yearly
Change engine oil
1
Every 100 Hours or Yearly
Service fuel valve
Service spark plug
Inspect muffler and spark arrester
Clean cooling system
1
14 BRIGGSandSTRATTON.COM
Not for
Reproduction
15
Engine Maintenance
Oil
Oil Recommendations
We recommend the use of Briggs & Stratton Warranty Certified oils for best
performance. Other high-quality detergent oils are acceptable if classified for
service SF, SG, SH, SJ or higher. DO NOT use special additives.
Outdoor temperatures determine the proper oil viscosity for the engine.
Use the chart to select the best viscosity for the outdoor temperature range
expected.
* Below 4°C (40°F) the use of SAE 30 will result in hard starting.
** Above 27°C (80°F) the use of 10W30 may cause increased oil consumption.
Check oil level more frequently.
Checking Oil Level
Figure
5
Oil level should be checked prior to each use or at least every 8 hours of
operation. Keep oil level maintained.
1. Make sure generator is on a level surface.
2. Clean area around oil fill (A) and remove oil fill cap.
3. Verify oil is at the point of overflowing (B) at oil fill opening.
4. Replace and tighten oil fill cap.
Adding Engine Oil
Figure
5
1. Make sure generator is on a level surface.
2. Check oil level as described in Checking Oil Level.
3. If needed, slowly pour oil into oil fill opening to the point of overflowing
at oil fill.
4. Replace and tighten oil fill cap.
Changing Engine Oil
Figure
3
If you are using your generator under extremely dirty or dusty conditions, or in
extremely hot weather, change the oil more often.
CAUTION Avoid prolonged or repeated skin contact with used motor
oil.
Used motor oil has been shown to cause skin cancer in certain laboratory
animals.
Thoroughly wash exposed areas with soap and water.
KEEP OUT OF REACH OF CHILDREN. DON’T POLLUTE.
CONSERVE RESOURCES. RETURN USED OIL TO COLLECTION
CENTERS.
Change the oil while the engine is still warm from running, as follows:
1. Make sure unit is on a level surface.
2. Disconnect the spark plug wire from the spark plug and place the wire
where it cannot contact spark plug.
3. Clean area around oil drain plug (3, G). The oil drain plug is located at
base of engine, opposite carburetor.
4. Remove oil drain plug and drain oil completely into a suitable container.
5. Reinstall oil drain plug and tighten securely. Remove oil fill cap.
6. Repeat steps 3 and 4 to add engine oil as described in Adding Engine
Oil.
7. Wipe up any spilled oil.
Service Air Cleaner
Figure
6
Your engine will not run properly and may be damaged if you run it with a dirty
air cleaner. Service more often if operating under dirty or dusty conditions.
To service the air cleaner, follow these steps:
1. Loosen screw (A) and tilt cover (B) down.
2. Carefully remove cartridge (C) assembly.
3. To clean cartridge, gently tap pleated paper side on a flat surface.
4. Reinstall clean or new cartridge assembly inside cover.
5. Insert cover’s tabs (D) into slots in bottom of base (E).
6. Tilt cover up and tighten screw securely to base
Service Spark Plug
Figure
7
Changing the spark plug will help your engine to start easier and run better.
1. Clean area around spark plug.
2. Remove and inspect spark plug.
3. Check electrode gap with wire feeler gauge and reset spark plug gap to
recommended gap if necessary (see Specifications).
4. Replace spark plug if electrodes are pitted, burned or porcelain
is cracked. Use the recommended replacement spark plug. See
Specifications.
5. Install spark plug and tighten firmly.
WARNING Unintentional sparking could cause fire or electric shock
resulting in death or serious injury.
WHEN ADJUSTING OR MAKING REPAIRS TO YOUR GENERATOR
Disconnect the spark plug wire from the spark plug and place the wire
where it cannot contact spark plug.
WHEN TESTING FOR ENGINE SPARK
Use approved spark plug tester.
DO NOT check for spark with spark plug removed.
Not for
Reproduction
Inspect Muffler and Spark Arrester Figure
8
Inspect the muffler for cracks, corrosion, or other damage. Remove the
spark arrester, if equipped, and inspect for damage or carbon blockage. If
replacement parts are required, make sure to use only original equipment
replacement parts.
Clean and inspect the spark arrester as follows:
1. To remove muffler guard (A), remove screws that connects guard to
muffler (B).
2. Remove screws that attaches spark arrester screen (C) to muffler.
Remove spark arrester screen.
3. Inspect screen and obtain a replacement if torn, perforated or otherwise
damaged. DO NOT use a defective screen. If screen is not damaged,
clean it with a brush.
4. Reattach screen to muffler. Reattach muffler guard.
Clean Cooling System
Figure
9
Over time debris may accumulate in cylinder cooling fins and cannot be
observed without partial engine disassembly. For this reason, we recommend
you have a Briggs & Stratton authorized dealer clean the cooling system (A)
per recommended intervals (see Maintenance Schedule in the Maintenance
section). Equally important is to keep top of engine free from debris. Also see
Cleaning.
Carburetor Adjustment
The carburetor on this engine is low emission. It is equipped with a non-
adjustable idle mixture valve. Top speed has been set at the factory. If
adjustment is required, see a Briggs & Stratton authorized dealer.
CAUTION Excessively high operating speeds could result in minor
injury.
Excessively low speeds impose a heavy load.
DO NOT tamper with governor spring, links or other parts to increase engine
speed.
DO NOT modify generator in any way.
Storage
If you will not be using the generator for more than 30 days, use the following
guidelines to prepare it for storage.
Generator Storage
Clean the generator as outlined in Cleaning.
Check that cooling air slots and openings on generator are open and
unobstructed.
Long Term Storage Instructions
Fuel can become stale when stored over 30 days. Stale fuel causes acid and
gum deposits to form in the fuel system or on essential carburetor parts. To
keep fuel fresh, use Briggs & Stratton Advanced Formula Fuel Treatment &
Stabilizer, available wherever Briggs & Stratton genuine service parts are sold.
For engines equipped with a FRESH START® fuel cap, use Briggs & Stratton
FRESH START available in a drip concentrate cartridge.
There is no need to drain petrol from the engine if a fuel stabilizer is added
according to instructions. Run the engine for 2 minutes to circulate the
stabilizer throughout the fuel system before storage.
If petrol in the engine has not been treated with a fuel stabilizer, it must be
drained into an approved container. Run the engine until it stops from lack of
fuel. The use of a fuel stabilizer in the storage container is recommended to
maintain freshness.
Change Engine Oil
While engine is still warm, drain oil from crankcase. Refill with recommended
grade. See Changing Engine Oil.
Other Storage Tips
1. Do Not store petrol from one season to another unless it has been
treated as described in Long Term Storage Instructions.
2. Replace petrol container if it starts to rust. Rust and/or dirt in petrol can
cause problems if it’s used with this unit.
3. Cover unit with a suitable protective cover that does not retain moisture.
4. Store generator in clean, dry area.
16 BRIGGSandSTRATTON.COM
WARNING Contact with muffler area can result in serious burns.
Exhaust heat/gases can ignite combustibles, structures
or damage fuel tank causing a fire.
DO NOT touch hot parts and AVOID hot exhaust gases.
Allow equipment to cool before touching.
Keep at least 1.5 m (5 feet) of clearance on all sides of generator
including overhead.
Contact the original equipment manufacturer, retailer, or dealer to obtain
a spark arrester designed for the exhaust system installed on this engine.
Replacement parts must be the same and installed in the same position
as the original parts.
WARNING Fuel and its vapors are extremely flammable and explosive
which could cause burns, fire or explosion resulting in
death or serious injury.
WHEN STORING FUEL OR EQUIPMENT WITH FUEL IN TANK
Store away from furnaces, stoves, water heaters, clothes dryers or other
appliances that have pilot light or other ignition source because they could
ignite fuel vapors.
WHEN DRAINING FUEL
Turn generator engine OFF and let it cool at least 2 minutes before
removing fuel cap. Loosen cap slowly to relieve pressure in tank.
Drain fuel tank outdoors.
Keep fuel away from sparks, open flames, pilot lights, heat, and other
ignition sources.
Check fuel lines, tank, cap and fittings frequently for cracks or leaks.
Replace if necessary.
DO NOT light a cigarette or smoke.
WARNING Storage covers could cause a fire resulting in death or
serious injury.
DO NOT place a storage cover over a hot generator.
Let equipment cool for a sufficient time before placing the cover on the
equipment.
Not for
Reproduction
Power Ratings: The gross power rating for individual petrol engine models is labeled in accordance with SAE (Society of Automotive Engineers) code J1940 Small
Engine Power & Torque Rating Procedure, and is rated in accordance with SAE J1995. Torque values are derived at 2600 RPM for those engines with “rpm” called
out on the label and 3060 RPM for all others; horsepower values are derived at 3600 RPM. The gross power curves can be viewed at www.BRIGGSandSTRATTON.
COM. Net power values are taken with exhaust and air cleaner installed whereas gross power values are collected without these attachments. Actual gross engine
power will be higher than net engine power and is affected by, among other things, ambient operating conditions and engine-to-engine variability. Given the wide
array of products on which engines are placed, the petrol engine may not develop the rated gross power when used in a given piece of power equipment. This
difference is due to a variety of factors including, but not limited to, the variety of engine components (air cleaner, exhaust, charging, cooling, carburetor, fuel pump,
etc.), application limitations, ambient operating conditions (temperature, humidity, altitude), and engine-to engine variability. Due to manufacturing and capacity
limitations, Briggs & Stratton may substitute an engine of higher rated power for this engine.
* This generator is rated in accordance with CSA (Canadian Standards Association) standard C22.2 No. 100-04 (motors and generators).
Troubleshooting
Problem Cause Correction
Engine is running, but no AC output is
available.
1. One of the circuit breakers is open.
2. Fault in generator.
3. Poor connection or defective cord set.
4. Connected device is bad.
1. Reset circuit breaker.
2. Contact authorized service facility.
3. Check and repair.
4. Connect another device that is in good condition.
Engine runs good at no-load but “bogs
down” when loads are connected.
1. Short circuit in a connected load.
2. Engine speed is too slow.
3. Generator is overloaded.
4. Shorted generator circuit.
5. Clogged or dirty fuel filter.
1. Disconnect shorted electrical load.
2. Contact authorized service facility.
3. See Don’t Overload Generator in Operation section.
4. Contact authorized service facility.
5. Clean or replace fuel filter.
Engine will not start; shuts down when
running or starts and runs rough.
1. On/off switch set to off position (0).
2. Fuel Valve is in off (0) position.
3. Low oil level.
4. Dirty air cleaner.
5. Clogged or dirty fuel filter.
6. Out of fuel.
7. Stale fuel.
8. Spark plug wire not connected to spark plug.
9. Bad spark plug.
10. Water in fuel.
11. Flooded.
12. Excessively rich fuel mixture.
13. Intake valve stuck open or closed.
14. Engine has lost compression.
1. Set on/off switch to on position (I).
2. Turn fuel valve to on (I) position.
3. Fill crankcase to proper level or place generator
on level surface.
4. Clean or replace air cleaner.
5. Clean or replace fuel filter.
6. Fill fuel tank.
7. Drain fuel tank and carburetor; fill with fresh fuel.
8. Connect wire to spark plug.
9. Replace spark plug.
10. Drain gas tank and carburetor; fill with fresh fuel.
11. Wait 5 minutes and re-crank engine.
12. Contact authorized service facility.
13. Contact authorized service facility.
14. Contact authorized service facility.
Engine lacks power.
1. Load is too high.
2. Dirty air filter.
3. Clogged or dirty fuel filter.
1. See Don’t Overload Generator.
2. Replace air filter.
3. Clean or replace fuel filter.
Engine “hunts” or falters.
1. Carburetor is running too rich or too lean.
2. Clogged or dirty fuel filter.
1. Contact authorized service facility.
2. Clean or replace fuel filter.
Product Specifications
Model 030617
Starting Wattage ........................................3,500 Watts
Wattage* ...............................................3,000 Watts
Load Current at 230 Volts AC ..............................13.0 Amps
Rated Frequency ..........................................50 Hertz
Phase ................................................Single Phase
Displacement ....................................250cc (15 24cu. in.)
Spark Plug Gap .................................. 0.76 mm (0.030 in.)
Fuel Capacity ..................................15 L (4.0 U.S. gallon)
Oil Capacity ...................................0.6 Liters (20 Ounces)
Common Service Parts
Air Cleaner ..........................................491588 or 5043
Resistor Spark Plug ..........................................491055
17
Not for
Reproduction
18 BRIGGSandSTRATTON.COM
BRIGGS & STRATTON POWER PRODUCTS GROUP, LLC PORTABLE GENERATOR OWNER WARRANTY POLICY
ABOUT YOUR WARRANTY
We welcome warranty repair and apologize to you for being inconvenienced. Any Authorized Service Dealer may perform warranty repairs. Most warranty
repairs are handled routinely, but sometimes requests for warranty service may not be appropriate. For example, warranty service would not apply if equipment
damage occurred because of misuse, lack of routine maintenance, shipping, handling, warehousing or improper installation. Similarly, the warranty is void if the
manufacturing date or the serial number on the portable generator has been removed or the equipment has been altered or modified. During the warranty period,
the Authorized Service Dealer, at its option, will repair or replace any part that, upon examination, is found to be defective under normal use and service. This
warranty will not cover the following repairs and equipment:
Normal Wear: Outdoor Power Equipment, like all mechanical devices, needs periodic parts and service to perform well. This warranty does not cover
repair when normal use has exhausted the life of a part or the equipment.
Installation and Maintenance: This warranty does not apply to equipment or parts that have been subjected to improper or unauthorized installation or
alteration and modification, misuse, negligence, accident, overloading, overspeeding, improper maintenance, repair or storage so as, in our judgment, to
adversely affect its performance and reliability. This warranty also does not cover normal maintenance such as air filters, adjustments, fuel system cleaning
and obstruction (due to chemical, dirt, carbon, lime, and so forth).
Other Exclusions: This warranty excludes wear items such as o-rings, filters, etc., or malfunctions resulting from accidents, abuse, modifications,
alterations, or improper servicing or freezing or chemical deterioration. Accessory parts such as starting batteries, generator adapter cord sets and storage
covers are excluded from the product warranty. This warranty excludes used, reconditioned, and demonstration equipment, equipment used for prime
power in place of utility power, equipment used in life support applications, and failures due to acts of God and other force majeure events beyond the
manufacturers control. 198189E, Rev. D, 09/10/2012
BRIGGS & STRATTON POWER PRODUCTS GROUP, LLC
MILWAUKEE, WI, USA
Effective September 1, 2012; replaces all undated Warranties and all Warranties dated before September 1, 2012.
2 years*
1 year
Consumer Use
Commercial Use
*Second year parts only
WARRANTY PERIOD
LIMITED WARRANTY
Briggs & Stratton warrants that, during the warranty period specified below, it will repair or replace, free of charge, any part that is defective in material or
workmanship or both. Transportation charges on product submitted for repair or replacement under this warranty must be borne by purchaser. This warranty
is effective for and is subject to the time periods and conditions stated below. For warranty service, find the nearest Authorized Service Dealer in our dealer
locator map at BRIGGSandSTRATTON.com. The purchaser must contact the Authorized Service Dealer, and then make the product available to the
Authorized Service Dealer for inspection and testing.
There is no other express warranty. Implied warranties, including those of merchantability and fitness for a particular purpose, are limited to
one year from purchase, or to the extent permitted by law. All other implied warranties are excluded. Liability for incidental or consequential
damages are excluded to the extent exclusion is permitted by law. Some states or countries do not allow limitations on how long an implied warranty
lasts, and some states or countries do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation and exclusion may
not apply to you. This warranty gives you specific legal rights and you may also have other rights which vary from state to state or country to country.**
** In Australia - Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a
major failure and for compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods
fail to be of acceptable quality and the failure does not amount to a major failure. For warranty service, find the nearest Authorized Service Dealer in our dealer
locator map at BRIGGSandSTRATTON.COM, or by calling 1300 274 447, or by emailing or writing to [email protected], Briggs & Stratton
Australia Pty Ltd, 1 Moorebank Avenue, NSW, Australia, 2170.
The warranty period begins on the date of purchase by the first retail end user, and continues for the period of time stated above. “Consumer Use” means personal
residential household use by a retail consumer. “Commercial Use” means all other uses, including use for commercial, income producing or rental purposes. Once
equipment has experienced commercial use, it shall thereafter be considered as commercial use for purposes of this warranty. Equipment used for prime power in
place of utility are not applicable to this warranty.
NO WARRANTY REGISTRATION IS NECESSARY TO OBTAIN WARRANTY ON BRIGGS & STRATTON PRODUCTS. SAVE YOUR PROOF OF
PURCHASE RECEIPT. IF YOU DO NOT PROVIDE PROOF OF THE INITIAL PURCHASE DATE AT THE TIME WARRANTY SERVICE IS REQUESTED, THE
MANUFACTURING DATE OF THE PRODUCT WILL BE USED TO DETERMINE THE WARRANTY PERIOD.
Not for
Reproduction
19
Not for
Reproduction
BRIGGS & STRATTON POWER PRODUCTS GROUP, LLC
MILWAUKEE, WISCONSIN, U.S.A.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20

Simplicity PORTABLE GENERATOR, BRIGGS & STRATTON, 3000, 030617-00 User manual

Category
Power generators
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI