AR North America FFRCAM025-Pro Installation guide

Type
Installation guide
4
WARRANTY
AR Blue Mist warrants its products to be free of defects in material and workmanship for a
period of following time from the date of purchase:
1 YEAR WARRANTY: On all High Pressure Mist Pumps and Motors.
90 DAY WARRANTY: All other parts.
This warranty applies only to products used in consumer applications and is void in rental or
any commercial application.
The warranty does not cover damage or broken parts due to misuse of the system or damage
to the system due to the growth of trees,  oods, falling tree limbs, power surges or faulty
electrical connections, internal/external water damage, action of customer or of third parties.
The warranty does not cover modi cations to or replacement of any parts of the system
required by changes in federal, state, or local laws, regulations, or ordinances. Furthermore,
warranty does not cover normal wear and tear, appearance, accident,  re, external freezing,
hot water damage, overuse or misapplication. Issues such as noise level, clogging of the
nozzles and leaks arising from improper installation are not considered defect. Issues arising
from poor maintenance and failure to change  lter and oil at speci ed intervals (every 500
hours) does not qualify for warranty replacement. Water seal wear on high pressure pumps
may be limited to 1000 hours or less. Warranty does not cover damage to the pump when it
is run dry.
If the system is not maintained or if any person other than an authorized AR Blue Mist,
representative services, and/or modi es the system, the warranty will be void, and any
repairs will be charged to the customer. AR Blue Mist’s obligation under this warranty shall be
limited to replacing or repairing at AR Blue Mist discretion, any such product or part which
must be returned to AR Blue Mist with a Return Authorization Number (RMA), transportation
charges prepaid, and which upon examination, is found to AR Blue Mist’s satisfaction to have
been defective under the terms of this warranty. No credit will be allowed against future
purchases for items returned as defective under the terms of AR Blue Mist warranty.
This warranty does not extend to any products, which have been altered or modi ed after
shipment from AR Blue Mist nor does it apply to units that are returned in an unassembled
condition. This is a Limited Warranty. It covers the product only and the extent of the
coverage is limited to the cost of the product itself. As the manufacturer has no control over
shipping, handling and improper installation. AR Blue Mist is not liable for damages or any
expenses incurred through the use of its products. The warranty will be considered violated
if the products are used for other than the criteria described in each product‘s guidelines
for use. This warranty is non-transferable. Labor charges may apply. Nozzles and Filters are
excluded from this warranty.
NO IMPLIED WARRANTIES; LIMITATION OF LIABILITY. THERE ARE NO IMPLIED
WARRANTIES OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE. EXCEPT
FOR THE WARRANTY HEREIN, IN NO EVENT SHALL MIST-COOLING INC BE LIABLE TO
CUSTOMER OR ANY OTHER PARTY FOR LOSS OF PROFITS, INDIRECT, SPECIAL, INCIDENTAL,
CONSEQUENTIAL, EXEMPLARY, OR PUNITIVE DAMAGES ARISING OUT OF USE OF ITS
PRODUCTS. IN NO EVENT SHALL MIST-COOLING INC’.S MONETARY DAMAGES EXCEED THE
PURCHASE PRICE OF THE SYSTEM. THIS LIMITATION OF LIABILITY SHALL APPLY REGARDLESS
OF THE FORM OF ACTION, WHETHER IN CONTRACT OF TORT, INCLUDING MIST-COOLING
INC.’S PRICING REFLECTS THE ALLOCATION OF RISK AND LIMITATIONS ON LIABILITY
CONTAINED IN THIS AGREEMENT. ANY CUSTOMER PURCHASING AND/OR USING MIST-
COOLING INC.’S PRODUCTS HEREBY AGREES TO ABOVE TERMS.
If you wish to make a warranty claim, please contact us via email [email protected] or
1-866-235-5112. Original proof of purchase is required for any warranty claim.
1
OWNER MANUAL
MODEL: ARM-PRO20’PATIO
AR Pro 20’ Patio Misting Kit
Package Content
Pos: Description Part Number Qty
1 .012” NPB SS Nozzles ARM-20012-1 10
2 Push Lock Nozzle Adapter ARM-30100 10
3 Push Lock Elbow ARM-32100 1
4 24” Stainless Steel Tubing ARM-40024SS 13
5 Push Lock Union ARM-31100 2
6 Push Lock End Plug ARM-34100 1
7 Nylon Clamps 3/8”* ARM-44200 20
1 2
4
3
5
6 7
* Mounting Fasteners NOT included, select fasteners compatible with mounting surface.
2
Push Lock
Nozzle Adapter
Push Lock
Nozzle Adapter
with
Auto Drain
Nozzle**
Push Lock
Nozzle Adapter
Push Lo
c
Nozzle Ad
a
Push Lock
Elbow
Nylon
Clamps
Nylon
Clamps
Nylon
Clamps
Vinyl
Clamps**
Vinyl
Clamps**
Vinyl
Clamps**
Vinyl
Clamp**
Misting
Pump*
.012”
NPB SS
Nozzle
.012”
NPB SS
Nozzle
.012” NPB
Nozzle
24” Stainless
Steel Tubing
24” Stainless
Steel Tubing
24” Stainless
Steel Tubing
50’ Flexible
Nylon
Tubing**
50’ Flexible
Nylon
Tubing**
50’ Flexible
Nylon
Tubing**
Measure Area for mounting.
Notes:
Misting System is intended for outdoor use only.
• Misting Pumps and AR-Pro 50’ Connection Kit are sold separately
Creating corners can be done using the Push Lock Elbow
(one is included, and more can be purchased at the store or at
www.bluemist.com).
Pictured: 3/8” Push Lock Elbow (Part # ARM-32100-1)
* Choose between the
FFRCAM050-PRO (1/2 Gallon Misting Pump)
or
FFRCAM100-PRO (1 Gallon Misting Pump)
depending on your misting needs!
(EACH SOLD SEPARATELY)
** Part of the
AR-Pro 50’
Connection Kit
(SOLD SEPARATELY)
Male
Straight**
INSTALLATION INSTRUCTIONS
1. Measure the length of your patio perimeter (or perimeter of the area to be misted). Proper
installation of your new AR Pro 20’ Misting Kit requires mounting the 24” Stainless Steel Tubing
on the bottom outside edge of the fascia, header or beam of patio perimeter. It is important to
mount the line along the bottom edge, to prevent mist from spraying on structure. This installation
will create a curtain of mist around your patio or misted area and provide maximum cooling.
2. Start the installation by connecting the 3/8” Male Straight Fitting** to your Misting Pump’s*
outlet then connect the 50’ Flexible Nylon Tubing** to the 3/8” Male Straight Fitting**. Secure
the 50’ Flexible Nylon Tubing** to a vertical base using the Vinyl Clamps**.
3
c
k
a
pter
Push Lock
Nozzle Adapter
Push Lock
Nozzle Adapter
Push Lock
Nozzle Adapter
Nylon
Clamps
Nylon
Clamps
Nylon
Clamps
Rubber
Poppet
O-Rings
SS .012” NPB
SS Nozzle
.012” NPB
SS Nozzle
.012” NPB
SS Nozzle
Push Lock Plug
24” Stainless
Steel Tubing
24” Stainless
Steel Tubing
24” Stainless
Steel Tubing
3. After securing your
AR-Pro 50’
Connection Kit to your vertical base, use Push Lock Elbow to
connect 50’ Flexible Nylon Tubing** to your 24” Stainless Steel Tubing. Secure 24” Stainless
Steel Tubing to the bottom outside edge of fascia, header or beam with Nylon Clamps. If
necessary, cut the nylon tubing with a tubing cutter. Never use a saw on the tubing, this will
leave burs and prevent the compression joints from sliding over the tubing. Do NOT cut the 24”
Stainless Steel Tubing.
4. Space Nylon Clamps on 24” Stainless Steel Tubing apart. Use Push Lock Nozzle Adapters to
join sections of 24” Stainless Steel Tubing. Terminate system with Push Lock Plug.
5. Install a Push Lock Nozzle Adapter and Auto Drain Nozzle into an early section of your AR-Pro
50’ Connection Kit. This will allow the system to drain properly.
6. Secure the 24” Stainless Steel Tubing with the Nylon Clamps.
7. Flush the system for several minutes before inserting .012” NPB SS Nozzles.
8. While the system is  ushing, start inserting the .012” NPB SS Nozzles nearest to the pump  rst and
working your way towards the Push Lock Nozzle Adapter with the Push Lock Plug.
9. Shut water o to insert last .012” NPB SS Nozzle.
Caution: Hand tighten only. Never use pliers to tighten .012” NPB SS Nozzles.
MAINTENANCE INSTRUCTIONS
When turning the misting system o , it is bene cial to drain the water out of the line by
disconnecting the garden hose at the  lter. This will help eliminate mineral buildup.
.012” NPB SS Nozzles require cleaning or replacement periodically. Clean .012” NPB SS Nozzles
by soaking in vinegar or calcium removal product overnight. NOTE: Remove O-Rings and rubber
poppet prior to cleaning. Vinegar will degrade the rubber material.
Winterize your misting system by removing all .012” NPB SS Nozzles. Be sure all water is drained
from misting lines. This will prevent water from freezing and damaging the mist line.
NOZZLE CLEANING
1. Disassemble the .012” NPB SS Nozzles as illustrated.
2. After disassembling the .012” NPB SS Nozzles, use a cleaner (to help breakup hard water/calcium
build up) or ultrasonic cleaning machine to clean the metal parts so as to remove water stains and
calcium accumulations over time.
3. After the metal parts are cleaned and dried fully, reassemble in the reverse order it was taken apart.
4. Make sure the Metal Insert, Spring, and Rubber Poppet are dust and  ber free before the
assembly process.
Ru
Po
  • Page 1 1
  • Page 2 2

AR North America FFRCAM025-Pro Installation guide

Type
Installation guide

Ask a question and I''ll find the answer in the document