BLACK
GREEN
RED
COLOR KEY
Bk
Gn
Rd
YELLOW
WHITE
3L2 5L3
13
NO
2T1
4T2
6T3
14
NO
TEST
TRIP IND.
97 NO
98 NO
95 NC
96 NC
2T1
4T2
6T3
O
R
54
NO
NO
53
ON
OFF
RESET
10 HP 440V Motor
440 Volt
3-Phase
Power Source
M
A
1L1
TECO
CU-
16
Ground





Figure 1.

MODEL T24202
10 HP 440V 3-PHASE
MAGNETIC SWITCH
INSTRUCTIONS
Electrocution or fire
could occur if this
switch is not installed
by an electrician or
qualified service per-
sonnel!

WARNING: NO PORTION OF THIS MANUAL MAY BE REPRODUCED IN ANY SHAPE
OR FORM WITHOUT THE WRITTEN APPROVAL OF GRIZZLY INDUSTRIAL, INC.

OPERATION :
               






Thermal Relay Overload Amp
Adjustment Dial:
    
    
    


     
    
    
     

Trip Indicator:   
    

Manual Trip Test Lever:  

      
    



OFF Button:    

Manual Contactor Override
Lug: 
    

ON Button:  
     
    

Manual/Auto Reset Lever: 

     
    
    

     
     
   

Reset Button:  

 

REF DESCRIPTION REF DESCRIPTION
1 SWITCH BOX 7 PHLP HD SCR M3-.5 X 10
2 SWITCH BOX COVER ASSEMBLY 8 CAPTURED GROUND SCR M4-.7 X 10
3 CONTACTOR TECO CU-16 440V 9 PHLP HD SCR 10-24 X 1-1/2
4 FIELD SWITCH TECO CNA-1 10 LIQUID-TITE STRAIN RELIEF
5 OL RELAY TECO RHU-10K1 15-20A 11 RUBBER SEAL
6 GROUNDING PLATE 12 PLASTC SCREW M10-1.5 X 20 GRAY
Parts Breakdown
1
2
12
3
4
5
6
7
8
9
10
11
Parts breakdown provided for reference only. Not all parts shown are available for purchase.
/