AMG AMG4704ER-SF Instruction Sheet

Type
Instruction Sheet

AMG AMG4704ER-SF is a rackmount receive unit that can transmit and receive 1 data signal plus full duplex 100BaseT Ethernet connectivity over one single-mode fiber. It is designed to operate with an AMG4703E-SF or rackmount equivalent AMG4703ER-SF data transmit unit in a point-to-point configuration. The device has one channel, Channel A, which allows for a RS232, RS422 (full duplex, four wire), or RS485 (half duplex, two wire) interface, depending on the position of the switch located above the RJ45 connector.

AMG AMG4704ER-SF is a rackmount receive unit that can transmit and receive 1 data signal plus full duplex 100BaseT Ethernet connectivity over one single-mode fiber. It is designed to operate with an AMG4703E-SF or rackmount equivalent AMG4703ER-SF data transmit unit in a point-to-point configuration. The device has one channel, Channel A, which allows for a RS232, RS422 (full duplex, four wire), or RS485 (half duplex, two wire) interface, depending on the position of the switch located above the RJ45 connector.

AMG Systems Ltd. reserves the right to make changes to this
document without notice. The information herein is believed to
be accurate. No responsibility is assumed by AMG for its use.
Page
1
of
8
AMG4704ER
-
SF
Sheet
D18077
-
01.doc
AMG4704ER
-
SF
Instruction Manual
Data Receive Unit with Bi
-
directional Data Channel plus
Ethernet
The
AMG4704ER
-
SF
is a rackmount receive unit designed to transmit and receive 1 data signal plus
full duplex 100BaseT Ethernet connectivity over
one singlemode fibre.
The
AMG4704ER
-
SF
is designed to plug into an AMG2005 or AMG2009 subrack, which in turn fits
into a 19" rack system.
The
AMG4704ER
-
SF
is designed to operate with an
AMG4703E
-
SF
or rackmount equivalent
AMG4703ER
-
SF
data transmit unit
in a point to point configuration.
AMG Systems Ltd. reserves the right to make changes to this
document without notice. The informati
on herein is believed to
be accurate. No responsibility is assumed by AMG for its use.
Page
2
of
8
AMG4704ER
-
SF
Sheet
D18077
-
01.doc
Contents
Introduction
3
Unit Functional Schematic
................................
................................
................................
..................
3
Optical Connection
................................
................................
................................
.............................
3
Ethernet Operation
................................
................................
................................
.............................
3
Connections
4
Optical Connections
................................
................................
................................
...........................
4
Power Connection
................................
................................
................................
..............................
4
Ethernet Connection
................................
................................
................................
...........................
4
Data and Audio Channel Connections
................................
................................
...............................
4
Data and Audio Channel Configuration
5
Data and Audio Channel Configuration
................................
................................
..............................
5
Data Interface Connections Channel A
................................
................................
..............................
5
Data Channel A Configuratio
n
................................
................................
................................
............
5
Front Panel Indicators
6
Power LED
................................
................................
................................
................................
..........
6
Fibre Optic LED’s
................................
................................
................................
...............................
6
Low Speed Data LEDs
................................
................................
................................
.......................
6
Physical Information
7
Dimensions
................................
................................
................................
................................
.........
7
Mounting Details
................................
................................
................................
................................
.
7
Removal / replacement from / to the Case
................................
................................
.........................
7
Safety
7
Maintenance and Repair
7
AMG Systems Lt
d. reserves the right to make changes to this
document without notice. The information herein is believed to
be accurate. No responsibility is assumed by AMG for its use.
Page
3
of
8
AMG4704ER
-
SF
Sheet
D18077
-
01.doc
Introduction
Unit Functional Schematic
The
AMG4704ER
-
SF
transmits one data
signal to the
AMG4703ER
-
SF
.
It also receives one data channel
transmitted from the
AMG4703ER
-
SF
.
Ethernet connectivity is also provided
betwee
n the two units.
Optical Connection
The
AMG4704ER
-
SF
is connected as illustrated below when used with an
AMG4703ER
-
SF
data
transmit unit acting as a point to point system.
Ethernet Operation
In order for the AMG system to transmit Ethernet si
gnals, an onboard RJ45 Ethernet interface or
X16003 Ethernet interface adaptor should be fitted to both the Transmit unit and the Receive unit.
The Ethernet interface can operate at either 10Mbits/s half duplex, or 100Mbit/s full duplex, and data is
trans
mitted from one port the other port with the minimum of delay or buffering. The maximum
bandwidth (at 100Mbit/s full duplex) available for transmission across the fibre link is nominally
50MBit/s.
The 100BaseT port does not implement MDI/MDIX; it should
be connected with a straight though
cable to an external switch port and with a cross over cable when connected directly to a PC or DTE.
AMG Systems Ltd. reserves the right to make changes to this
document without notice. The information herein is believed to
be accurate. No responsibility is assumed by AMG for its use.
Page
4
of
8
AMG4704ER
-
SF
Sheet
D18077
-
01.doc
Connections
Optical Connections
PRIMARY OPTO IN
Connector
................................
............
LC/PC
Optical Fibre
................................
........
One fibre
-
Singlemode
Primary Optic
al Launch Power
............
-
5dBm
Wavelength
................................
..........
1310nm
Primary Optical Sensitivity
...................
-
22dBm
Wavelength
................................
..........
1550nm
Power Connection
Power supply
................................
.......
from plug in connection on the AMG2009 / AMG2015 subrack
Power consumption
.............................
5 Watts max.
Ethernet Connection
Ethernet Data Connec
tor
....................
RJ45
Interface
................................
...............
Auto
-
negotiation up to 100BASE
-
TX full duplex
Ethernet Data Rate
..............................
Maximum 50Mbits/s total Ethernet traffic on fibre
Data and Audio Channel Connections
DATA CHANNEL A
Data Channel A
................................
...
1 channel
Data Connector
................................
....
RJ45
Channel A Interface
.............................
On B
oard Data Interface
RS232, RS422 or RS485. Selected
by slide switch above the RJ45 connector.
RS232
switch position
-
high (closest to BNC connections)
RS422
switch position
middle
RS485
switch position
low (furthest from BNC connections)
DATA CHANNEL B
Data Channel B
................................
...
Not Present
AMG Systems Ltd. reserves the right to make changes to this
document without notice. The information h
erein is believed to
be accurate. No responsibility is assumed by AMG for its use.
Page
5
of
8
AMG4704ER
-
SF
Sheet
D18077
-
01.doc
Data and Audio Channel Configuration
Data and Audio Channel Configuration
The
AMG4704E
-
SF
and rackmount equivalent
AMG4704ER
-
SF
sends and receives data to/from
Channel A. Channel B is not available. Channel A i
s a single data interface selectable by the user with
the slide switch on the rear panel.
Data Interface Connections Channel A
Channel A
RJ45 Pin
No.
RS485
[switch low]
RS422 [switch
mid]
RS232
[switch high]
Cat 5/6 Cable
Colour Code T568B
1
IN + (A)
GND
White/orange
2
IN
-
(B)
IN
Orange
3
White/green
4
Blue
5
White/blue
6
Green
7
IN/OUT + (A)
OUT + (A)
N/A
White/brown
8
IN/OUT
-
(B)
OUT
-
(B)
OUT
Brown
Note: (A) or (B) in brackets in above tabl
e refers to RS485 / RS422 data specification, not Channel A,
Channel B.
Data Channel A Configuration
Channel A is always present and allows for a RS232, RS422 (full duplex, four wire) or RS485 (half
duplex, two wire) interface depending on the position o
f the switch located above the RJ45 connector.
The switch signifies the presence of the X16004 Low Speed Data/Audio Interface Board. If there are
LED's present on the RJ45 connector then an X16003 Ethernet Interface Board is fitted.
The data input for bot
h the RS485 and the RS422 modes detects a tri
-
state input condition by
monitoring the differential voltage level across the input. A differential level below 600mV positive or
negative will be detected as a tri
-
state condition. A level above 600mV positive
or negative will be
detected as a logic 1 or logic zero respect
ively. It is important therefore to terminate the RS485 bus or
the RS422 input bus using 120Ωif a pre
-
bias is present on the RS485 or RS422 bus.
A large number of third party equipment manufacturers apply a pre
-
bias on their RS485 bus. This pre
-
bias is
applied by pulling one arm of the RS485 bus high (+5 volts) and the other arm low (0 volts)
using high value resistors within the third party equipment. In order to ensure that the AMG equipment
detects a tri
-
state condition, then these resistors should ha
ve a value above 5k
Ω. If the third party
bias resistors are less the 750Ωthe bus can be double or triple terminated as required to ensure that a
tri
-
state level is detected.
Note: The Data Channel A is shipped from the factory set up for RS485 operation unless otherwise
r
equested.
AMG Systems Ltd. r
eserves the right to make changes to this
document without notice. The information herein is believed to
be accurate. No responsibility is assumed by AMG for its use.
Page
6
of
8
AMG
4704ER
-
SF
Sheet
D18077
-
01.doc
Front Panel Indicators
Power LED
Power
................................
...................
Green
-
unit powered
Off
-
no power applied to unit
Fibre Optic LED’s
Primary Opto Sync TX
.........................
Green
-
optical channel transmitting
Off
-
optical channel not transmitting
Primary Opto Sync RX
.........................
Green
-
optical channel receiving
Org
-
optical channel receiving but not sync.
Off
-
optical channel not transmitting
Low Speed Data LEDs
Channel A
Data Present TX (RS485 or RS422)
...
Green
-
logic zero (+V,
-
V) present on IN+, IN
-
Red
-
logic one (
-
V,V+) pre
sent on IN+, IN
-
Off
-
tri
-
state off or no connection on IN+, IN
-
Data Present TX (RS232)
....................
Green
-
logic zero (+V) present on input IN+
Red
-
logic transitions present on input IN+
Off
-
logic one (
-
V) present on input IN+
This represents the data si
gnals being transmitted on the optical fibre
Data Present RX (RS485 or RS422)
...
Green
-
logic zero (+V,
-
V) present on OUT+, OUT
-
Red
-
logic one (
-
V,+V) present on OUT+, OUT
-
Off
-
tri
-
state off or no connection on OUT+, OUT
-
Data Present RX (RS232)
...................
Gre
en
-
logic zero (+V) present on OUT+
Red
-
logic transitions present on OUT+
Off
-
logic one (
-
V) present on OUT+
This represents the data signals being received on the optical fibre
AMG Systems Ltd. reserves the right to make changes to this
document without notice. The information herein is believed to
be accurate. No responsibility is assumed by AMG for its use.
Page
7
of
8
AMG4704ER
-
SF
Sheet
D18077
-
01.doc
Physical Information
Dimensions
Height
................................
..................
3U Plug
-
in
Width
................................
...................
14HP
Dep
th
................................
...................
170mm excluding connectors
Weight
................................
.................
750grams
Mounting Details
The unit is designed to be mounted within an AMG2009 or AMG2015 Subrack on standard card
guides.
Removal / replacement from / to the Case
Note:
-
The AMG unit PCB's are static sensitive. H
andle with proper care and use normal electrostatic
discharge (ESD) procedures. Use properly grounded protection (for example, wrist straps) when
handling the PCB.
To remove units from the case to access the data expansion boards and the daughter boards,
remove
the 2 or 4 fixing screws on the rear panel and slide the PCB's out of the case.
Ensure that the fibres do not snag or get trapped.
To replace the PCB's into the case, slide the PCB's gently into the case aligning the boards with the
appropriate
slots. Ensure that the fibre do not snag or get trapped.
Safety
AMG Optical Fibre Products use Class 1 laser systems in accordance with EN 60825
-
2:2000.
It is always advisable to follow good practice when working with optical fibre systems. This includ
es:
Do not stare with unprotected eyes or with any unapproved collimating device at fibre
ends or connector faces, or point them at other people.
Use only approved filtered or attenuating viewing aids
For other safety issues and advice on good practice a
ssociated with optical fibre systems, please see
EN 60825
-
2:2000 or your local safety officer.
Maintenance and Repair
There are no user serviceable parts within AMG products. See unit data sheet for full specification.
In case of problem or failure, pl
ease call your local support centre or contact:
AMG Systems Ltd.
at
3 The Omega Centre, Stratton Business Park, Biggleswade, Beds., SG18 8QB, UK.
Phone
+44 (0) 1767 600 777
Technical Support
+44 (0) 1767 604 491
Email
techsupport@amgsystems.c
om
AMG Systems Ltd. reserves the right to make changes to this
document without notice. The information herei
n is believed to
be accurate. No responsibility is assumed by AMG for its use.
Page
8
of
8
AMG4704ER
-
SF
Sheet
D18077
-
01.doc
This page is intentionally blank.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

AMG AMG4704ER-SF Instruction Sheet

Type
Instruction Sheet

AMG AMG4704ER-SF is a rackmount receive unit that can transmit and receive 1 data signal plus full duplex 100BaseT Ethernet connectivity over one single-mode fiber. It is designed to operate with an AMG4703E-SF or rackmount equivalent AMG4703ER-SF data transmit unit in a point-to-point configuration. The device has one channel, Channel A, which allows for a RS232, RS422 (full duplex, four wire), or RS485 (half duplex, two wire) interface, depending on the position of the switch located above the RJ45 connector.