EcoFlow DELTA 2 - App User manual

Type
User manual
APP USER MANUAL
V1.0
EcoFlow DELTA 2
Table of Contents
How to Connect to DELTA 2 1
Bluetooth connection 1
IoT connection 1
Homepage 2
Homepage style 2
Introduction 3
General Settings 3
Rename 3
Device sharing 4
Beep 4
Energy management 5
Input Settings 6
AC charging 6
Car input 7
Smart generator auto on/off 7
Output Settings 8
X-Boost 8
Auto Timeout 9
Other Settings 10
1
How to Connect to EcoFlow DELTA 2
IoT connection
There are two ways to connect to DELTA 2: Bluetooth and IoT.
Log in to the EcoFlow app, the Bluetooth connection window will pop up, and tap "Add" to connect to DELTA 2.
After the Bluetooth connection is successful, tap the icon in the upper right corner, select Wi-Fi, wait for the WI-FI
connection process to complete, and the IoT connection is completed.
Bluetooth connection
Select Wi-Fi
Wi-Fi
Password
DELTA 2
Add
2
Homepage style
Introduction
Homepage
There are 2 homepage styles of DELTA 2: standard and energy flow. The standard page displays the input and
output power of each port, and the energy flow page displays the remaining power, the remaining available time
and the internal temperature of the device in real time.
After connecting to Smart Extra Battery, it will indicate the icon and number of the Smart Extra Battery.
The app will display the corresponding data when the charging/discharging level has been set.
Energy ow style
Product name Settings
Total output
Solar Input
Remaining charging/
discharging time
DC output
AC output switch
12V DC output switch
USB output switch
Internet setup (Wi-Fi icon will
show up once it is connected)
Total input
AC input
Remaining power
AC output
Switching different page styles: Settings > Other > Homepage Style
Input Output
3
Total input power:
AC input;
Solar/Car charging input
Total output power:
AC output switch;
12V DC switch;
USB output switch
Standard
General Settings
The default name of the product is its serial number, but you can modify the product name through "Settings >
General > Rename".
Rename
General
Rename
Settings
SaveCancel
Rename
_ _ _ _
Remaining charging time Remaining charging time
Input Output Input Input
4
Tap "Device sharing" and add an account to "share" the device with other accounts to jointly control the device.
Turn on/off the key tone.
Device sharing
Beep
General
Rename
Device sharing
Settings
New invitation
Device sharing
On Off
General
Rename
Device sharing
Beep
Settings
General
Rename
Device sharing
Beep
Settings
5
Charging/discharging level
You can set the charging and discharging level on this page, with a range of 0-30% for discharging level and 50-
100% for charging level according to your preference. After setting, the device will stop charging or discharging at
the preset limits. After the limits are set, it will display the icon in the lower right corner of the screen.
Backup reserve level
You can customize personal preferences like power backup and energy saving by simply enabling this function in
the app by tapping the icon and setting the backup reserve level. A higher backup reserve level will allow you
to have a larger power reserve during power outages, whereas a lower backup reserve level will allow you to make
better use of solar power.
When the battery level is higher than the backup reserve level, DELTA 2 will be powered through solar charging,
and the AC input will be disabled; when the battery is lower than the backup reserve level, the device will start
charging from AC charging.
Energy management
Backup reserve level range: discharging level +5% ≤ backup reserve level ≤ charging level
Charging/Discharging level
Backup reserve level
0% 30%
Backup Reserve
50% 100%
Energy Management
Backup Reserve
Backup Energy saving
50%
35% 50%
6
Input Settings
You can adjust the AC input power of the product through AC charging power according to actual needs.
Customize: Select this item to set the AC input power by sliding left and right according to actual needs.
The charging power of other charging options can not be changed and is set to the default value, except for
automation.
Optimized battery charging: The AC input power is 500W.
Quiet charging: The AC input power is 200W.
AC charging speed
Customize the charging power here
Customize
Optimized battery
charging
Quiet charging
7
Set the input power for car charging, with 8A at maximum.
Connect Smart Generator to DELTA 2 to turn on the Smart Generator and monitor the battery level of DELTA 2.
You can set the battery level to start the Smart Generator engine, and when the total battery level is detected to be
lower than the preset engine start value, the engine will start to charge DELTA 2. Similarly, if it is monitored that the
battery level reaches the set value for turning off the engine, the engine will be turned off to stop charging.
Car input
Smart generator auto on/off
Input
AC charging
Car input
Smart generator auto on/off
30%0% 50% 100%
Smart Generator Auto On/Off
8
To prevent operational failure due to charging overload protection, when the total output power exceeds the rated
output power, the X-Boost function will be automatically activated. When using the X-Boost function, please note
the following:
1. X-Boost is not available when the AC output is turned on or when X-Boost is turned off in the recharging state (in
bypass mode, please refer to “Other Functions > X-Boost” in the user manual for details).
2. X-Boost is suitable for heating and motor equipment, but not for all electrical appliances. X-Boost is not suitable
for certain electrical appliances equipped with voltage protection (such as precise instruments). To verify whether
the X-Boost function can be used for a device, please refer to the actual test.
X-Boost
Output Settings
X-Boost Settings: Settings > Output > X-Boost
Enable X-Boost Disable X-Boost
X-Boost
Output
X-Boost
Output
9
There are “device timeout”, “screen timeout”, “AC timeout”, and “12V DC timeout” for the auto timeout functions of
DELTA 2.
Device timeout: If the device is not operating or has no load, it will automatically turn off once the preset timeout
duration has elapsed. If there is a load connected during standby, the shutdown time of the main power will be
delayed.
Device timeout setting: 30 minutes, 1 hour, 2 hours, 4 hours, 6 hours, 12 hours, 24 hours, always on.
Default: 2 hours.
Screen timeout: After the device is turned on, you can short press the main power button once to turn on/off the
screen, or you can set the duration of the screen through the "screen timeout" setting.
Screen timeout setting: 10 seconds, 30 seconds, 1 minute, 5 minutes, 30 minutes, always on.
Default: 5 minutes.
AC timeout: If AC output is not operating or has no load, the AC power will automatically turn off once the preset
timeout duration has elapsed.
AC timeout setting: 30 minutes, 1 hour, 2 hours, 4 hours, 6 hours, 12 hours, 24 hours, always on.
Default: 12 hours.
12V DC timeout: If 12V DC output is not operating or has no load, the 12V DC power will automatically turn off
once the preset timeout duration has elapsed.
12V DC timeout setting: 30 minutes, 1 hour, 2 hours, 4 hours, 6 hours, 12 hours, 24 hours, always on.
Default: 12 hours.
Auto Timeout
AC timeout
12V DC timeout
Screen timeout
Device timeout
10
1. To upgrade the firmware, please connect the device to Wi-Fi and switch it to IoT mode.
Firmware upgrade
Other Settings
2. Tap “Upgrade”.
If you have already switched the device into "IoT connection", you don’t need to select Wi-Fi for firmware
upgrade.
SN: xxxxxxxxxxxxx
50%
XXXXX
X.XX.XX.XXXX
X.XX.XX.XXXX
SN: xxxxxxxxxxxxx
X.XX.XX.XXXX
X.XX.XX.XXXX
XXXXX
11
You can choose a specific date for each charging/discharging cycle, and you can select the repetition
frequency by tapping “Repeat” (take "AC charging" as an example).
Customize
You can set a specific time point or period of time in a day to charge or discharge DELTA 2. The following modes are
currently available: AC charging, solar charging, AC discharging, and 12V DC discharging.
Lab features
12
Tap "Contact Customer Service" to enter any question you want to ask.
AC Always On
If this function is enabled, the AC output power is always on when the device is turned on; if this function is
disabled, you need to manually turn on the AC power after the device is turned off. In addition, once the "AC Always
On" is enabled, the AC power will not turn off automatically.
Help and feedback
13
Go to the parameter page, you can view the parameters of DELTA 2 and DELTA 2 Smart Extra Battery.
Go to the temperature unit page, you can set the temperature unit as Celsius or Fahrenheit.
You can unbind your phone from this device, and you can no longer set up the device via app.
Specifications
Temperature unit
Unlink
Cop yri ght ©2023 EcoFlow. All rights reserved.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16

EcoFlow DELTA 2 - App User manual

Type
User manual

Ask a question and I''ll find the answer in the document