Chamberlain 916GA is a safety sensor kit designed to provide additional safety and security for your gate system. It includes OPEN and CLOSE safety sensors that can be used to detect obstacles in the path of the gate, preventing it from closing or opening and causing injury or damage. The sensors can be installed on either side of the gate, up to 30 feet apart, and can be used with Chamberlain GA400D, GA420D, and GA200D gate operators. The kit also includes all the necessary hardware for installation, making it easy to set up and use.

Chamberlain 916GA is a safety sensor kit designed to provide additional safety and security for your gate system. It includes OPEN and CLOSE safety sensors that can be used to detect obstacles in the path of the gate, preventing it from closing or opening and causing injury or damage. The sensors can be installed on either side of the gate, up to 30 feet apart, and can be used with Chamberlain GA400D, GA420D, and GA200D gate operators. The kit also includes all the necessary hardware for installation, making it easy to set up and use.

Danger
Inside Property
®
Brackets
Hex Head Bolt (2)
Wing Nut (2)
Wire Nut (4)
ENTRAPMENT
Safety Sensors
Entrapment
DangerDanger
THE PROTECTOR SYSTEM
®
SAFETY SENSORS MODEL 916GA
CARTON INVENTORY
Verify carton inventory below.
OPEN and ENTRAPMENT Safety Sensors
CLOSE Safety Sensors
CLOSE
Safety Sensors
To prevent SERIOUS INJURY or DEATH:
Disconnect ALL electric and battery power BEFORE performing
ANY service or maintenance.
Correctly connect and align the safety sensors.
Install the sensor so beam is NO HIGHER than 24" (61 cm) above
ground.
This product is for use with Chamberlain
®
GA400D, GA420D, and
GA200D gate operators ONLY.
ATTENTION
AVERTISSEMENT AVERTISSEMENT
AVERTISSEMENT
WARNING
CAUTION
WARNING
WARNINGWARNING
PRECAUCIÓN
ADVERTENCIA
ADVERTENCIAADVERTENCIA
1
OPEN
Safety Sensors
IMPORTANT INFORMATION ABOUT THE SAFETY SENSORS
When properly connected and aligned, the sensor will detect an obstacle
in the path of its electronic beam.
The sensors must be installed so that the sending and receiving eyes
face each other across the gate, no more than 24" (61 cm) above the
ground. The sensors can be installed on the left or right of the gate as
long as the sun never shines directly into the receiving eye lens.
The safety sensors must be securely fastened to a solid surface such as
metal or a treated wood post (not provided). The light beam path must
be unobstructed during normal operation of the gate.
NOTE: Due to the variety of gates and mounting applications, PVC
conduit, wire, mounting hardware and posts are not provided. Refer to
your local hardware store for additional hardware.
APPLICATIONS
ENTRAPMENT SAFETY SENSORS
This will pause an opening gate until the obstruction has been
removed. Upon removing the obstruction, the gate will continue to
open. This will have no effect on the gate closing.
OPEN (PHOTO EYE/IR) SAFETY SENSORS
GA400D/GA420D - This will pause an opening gate until the
obstruction has been removed. Upon removing the obstruction, the
gate will continue to open. This will have no effect on the gate closing.
• GA200D - This will stop a closing or opening gate, once the
obstruction is removed the gate will continue to operate normally
upon the next command given.
CLOSE (PHOTO EYE/IR) SAFETY SENSORS
GA400D/GA420D - This will reverse a closing gate to the full open
position (open limit). This will have no effect on a gate opening.
• GA200D - This will stop a closing or opening gate, once the
obstruction is removed the gate will continue to operate normally
upon the next command given.
The Safety Sensor Kit is compatible with Chamberlain
®
Gate Access
Systems GA400D, GA420D, and GA200D. The Safety Sensors are
designed to detect an obstacle in the path of the electronic beam and
stop the gate operator.
Safety Sensors
(Includes receiving and sending sensor)
Inside Property
Metal
OR
Wood
ENTRAPMENT
Safety Sensor Posts
OPEN
Safety Sensor Posts
Inside Property
Outside Property
CLOSE
Safety Sensor Posts
Inside Property
6" (15 cm) trench for
safety sensor wires
OPEN SAFETY SENSORS
Inside Property
6" (15 cm) trench for
safety sensor wires
Outside Property
6" (15 cm) trench
for safety sensor
wires
CLOSE SAFETY SENSORSENTRAPMENT SAFETY SENSORS
NOTE: For ideal protection the safety sensors should be installed as close
to one another as possible with the maximum distance up to 30' (9.1 m).
To AVOID damaging gas, power or other underground utility lines,
contact underground utility locating companies BEFORE digging.
ATTENTION
AVERTISSEMENT AVERTISSEMENT
AVERTISSEMENT
WARNING
CAUTIONCAUTION
WARNING
WARNING
PRECAUCIÓN
ADVERTENCIA
ADVERTENCIAADVERTENCIA
2
SAFETY SENSOR POSTS
Use a metal or treated wood post (not provided) to elevate the sensors.
Safety sensors must be installed no higher than 24" (61 cm) above the
ground.
POWER
Disconnect power and batteries to the operator.
TRENCH FOR WIRING
Before digging, contact local underground utility locating companies.
Dig a narrow trench 6" (15 cm) deep from control box to safety sensor
posts. Be careful not to damage any buried wire. Run conduit from
control box to safety sensor posts and run low voltage wire* (not
provided) through conduit.
* UL approved Class 1 or Class 3 direct burial/underground, sunlight/UV resistant 16 gauge 2-conductor/standard wire.
ASSEMBLE SAFETY SENSORS
Insert hex head bolt through safety sensor and slide safety sensor into
bracket. Secure with wing nut.
MOUNT SAFETY SENSORS
Mount safety sensor assembly to post using appropriate hardware (not
provided). Safety sensors must be installed no higher than 24" (61 cm)
above the ground.
NOTE: Install safety sensor assembly with the two holes in the bracket
facing up and the LEDs visible at the top.
Safety Sensor Post
Mark Safety
Sensor Post No
Higher than 24"
(61 cm)
Safety Sensor Post
Safety Sensor
Assembly
Safety Sensor Post
Conduit
Safety Sensor Wires
Low Voltage
Wires to
Control Box
Wire Nuts
3
WIRE SAFETY SENSORS
1. Separate wires.
2. Strip 7/16" (11 mm) of insulation from low voltage wires.
3. Combine all like-colored wires and twist together with wire nuts.
CLOSE
EDGE
R93
L1
K2
OPEN EDGE/
OPEN
PHOTO
CLOSE
PHOTO
Z22
P1
F2
MOV1
D1
Q12
U4
CONTROL
INPUTS
FORCE
TIMER TO
CLOSE
OFF MAX
OPEN
SINGLE BUTTON
RESET
STOP
SHADOW
INTERRUPT
CHGR
OVLD
COM
COM
CTRL
LOOP
INPUTS
D129
Z4
U3
D2
D44
C11
C13
C12
K1
F3
K3
K4
R196
F7
CTRL
OVLD
TIMER
RUNNIN G
GATE 2
SET
OPEN
LIMIT
SET
CLOSE
LIMIT
LEARN
LIMITS
DIAGNOSTIC
GATE 1
LEARN
XMITTER
LOCK /
ON OFF
PWR
C69
OFF MAX
J2
Ø
PWR
SINGLE BUTTON
AC PWR
/SOLAR
D8
D4
R9
R329
R27
MOV2
R4
C2
BIPART DELAY
F12
Q9
Q6
Q1
J19
CESSORY
0VLD
C75
C73
C72
C71
C7
Ø
C66 C65
C68
C33
F11
R186
R42
Ø
R423
J24 J23 3
Ø
A 32V
30
C64
R22
U2
J18
K6
JU1
JU1
JU2
DB1
R184
OPEN
PHOTO
CLOSE
Z8
GE/
DGE/
Open
Safety
Sensors
Entrapment
Safety
Sensors
Close Safety Sensors
Black
striped
wires
Black
striped
wires
Black
Black
Black
striped
wires
Red
Red
Black
Black
Red
Red
Black
Black
Red
Red
YEL
T ALARM
JU1
R6
SWITCHIR
++
__
GRN
BRN
WHT
RED
BLU
SWITCHIR
++
__
Entrapment/Open
Safety Sensors
Black
striped
wires
Red
wires
Black
Striped Wire
Black
Striped Wire
Red
Red
Close
Safety Sensors
Red
Lead
Wire
Black
Striped
Lead
Wire
Indicator Light
MODEL GA200D
MODEL GA400D AND GA420D
NOTE: If the safety sensor wires need to be extended, the polarity must
be maintained when connecting the safety sensors to the control board.
The black striped wire connects to the negative (-) terminal and the red
wire connects to the positive (+) terminal.
MODEL GA200D ONLY
• Insert red lead wire into IR+ terminal.
• Insert black striped lead wire into IR- terminal.
MODELS GA400D AND GA420D ONLY
Entrapment Safety Sensors
Connect ENTRAPMENT safety sensor wires to P8 terminal.
Open Safety Sensors
Connect OPEN (Photo Input) safety sensor wires to P7 terminal.
Close Safety Sensors
Connect CLOSE (Photo Input) safety sensor wires to P9 terminal.
ALIGN SAFETY SENSORS
1. Reconnect power and batteries to the operator. The indicator lights in
both the sending and receiving eyes will glow steadily if wiring
connections and alignment are correct.
NOTE: The sending eye indicator light will glow regardless of alignment
or obstruction. If the indicator light in the receiving eye is off, dim, or
flickering (and the invisible light beam path is not obstructed), alignment
is required.
2. Loosen the sending eye wing nut and readjust, aiming directly at
the receiving eye. Lock in place.
3. Loosen the receiving eye wing nut and adjust sensor until it
receives the sender’s beam. When the indicator light glows
steadily, tighten the wing nut.
NOTE: When properly aligned, the indicator lights in both the sending
and receiving eyes will glow steadily.
TEST THE SYSTEM
1. Press the remote control button to open the gate.
2. Place an obstruction in the path of the close or entrapment safety
sensor.
3. Press the remote control button to close the gate. The gate
should stop.
4. Remove the obstruction and the operator will resume normal function.
The gate operator will not function from a remote control if the indicator
light in either sensor is off indicating the sensor is misaligned or
obstructed. If the system continues to fail the test, call for a trained gate
systems technician.
Verify all other safety devices operate correctly.
TROUBLESHOOTING
If the sending or receiving LEDs do not light up after installation, please
check the following:
Power supply to the operator. Operator may be in stand-by mode,
press the reset button to wake up the operator. Verify voltage at
inputs.
A short in the wires. Check wires.
Incorrect wire connections between the safety sensors and operator.
Verify wiring.
A broken wire. Check wires.
If both sensors are flashing:
• Align sensors.
• Remove obstruction.
GA200D - Disconnect safety sensors then turn power on unit.
GA400D/GA420D - Erase the programming for the safety
sensors - remove safety sensor. Press learn limits button then
press reset button.
© 2008, The Chamberlain Group, Inc.
01-33959C All Rights Reserved
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Chamberlain 916GA User manual

Category
Gate Opener
Type
User manual
This manual is also suitable for

Chamberlain 916GA is a safety sensor kit designed to provide additional safety and security for your gate system. It includes OPEN and CLOSE safety sensors that can be used to detect obstacles in the path of the gate, preventing it from closing or opening and causing injury or damage. The sensors can be installed on either side of the gate, up to 30 feet apart, and can be used with Chamberlain GA400D, GA420D, and GA200D gate operators. The kit also includes all the necessary hardware for installation, making it easy to set up and use.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI