GROHE 19347BE1 Installation guide

Category
Faucets
Type
Installation guide
D
.....1
NL
.....6
PL
.....11
P
.....16
BG
.....21
CN
.....26
GB
.....2
S
.....7
UAE
.....12
TR
.....17
EST
.....22
UA
.....27
F
.....3
DK
.....8
GR
.....13
SK
.....18
LV
.....23
RUS
.....28
E
.....4
N
.....9
CZ
.....14
SLO
.....19
LT
.....24
I
.....5
FIN
...10
H
.....15
HR
.....20
RO
.....25
DESIGN + ENGINEERING
GROHE GERMANY
www.grohe.com
20 297
20 431
ESSENCE NEW
99.0281.031/ÄM 235307/09.15
English .....1
Français .....2
Español .....3
I
S.v.p remettre cette instruction à l'utilisateur de la robinetterie!
Entregue estas instrucciones al usario final de la grifería!
Please pass these instructions on to the end user of the fitting!
20 297
20 431
4
English
Application
Operation is possible in conjunction with:
- Pressurized storage heaters
Operation is not possible with:
- Low-pressure storage heaters
(displacement water heaters)
Specifications
Flow rate at 60 psi flow pressure:
approx. 4.5 L/min or 1.2 gpm
Flow pressure
- min. 7.25 psi
- recommended 14.5 - 72.5 psi
- greater than 72.5 psi, fit pressure reducing valve
Max. operating pressure 145 psi
Test pressure 232 psi
Temperature
- max. (hot water inlet) 158 °F
Water connection cold - Right hand
hot - Left hand
Thermal desinfection possible
Note:
- Major pressure differences between cold and hot water
supply should be avoided.
Installation
Refer to the dimensional drawings on fold-out page I.
For deviation to the suggested installation, observe minimum
clearance required for escutcheon sizes.
Flush piping system prior and after installation of faucet
thoroughly!
Side valves, see fold-out page III, fig. [1].
Valve with a groove on the top edge of the cartridge (A) and
in addition marked with COLD should be mounted on the
right (cold water) side.
Valve without a groove on the top edge of the cartridge (A)
and in addition marked HOT should be mounted on the left
(hot water) side.
1. Screw the mounting set (B) to the bottom of the thread of the
side valve (C).
Make sure that the rubber washer (B1) is on the top of the
fiber washer (B2).
2. Insert the side valve (C) through the basin hole from below.
3. Close the headparts (clockwise for the hot side and counter-
clockwise for the cold side).
4. Place the escutcheon O-ring (D) on the basin and screw
down the handle with escutcheon (E) until it stops.
Be sure that the handle points away from the spout.
5. Tighten the mounting set (B) from below to secure the valve.
Spout, see fig. [2] to [4].
1. Place the escutcheon (G) and the ring (H) on the spout (I)
from bottom, observe the right position of the ring (H), and
insert the spout (I) through the basin hole from above, see
fig. [2].
2. Place the fastening set (J) against the bottom of the basin
and fasten with nut (K). Tighten nut (K) with a 23mm
wrench.
3. Insert the lift rod (F) through the spout.
4. Connect flexible hoses (L) to the side valves, see figs. [3]
and [4].
Mount pop-up drain, see fold-out pages II and III, fig. [5].
Ensure that flange of pop-up drain is sealed.
Connect wideset
Connect the side valves to the water supply.
Insure the supplied washers are used for all connections.
The cold water supply should be connected on the right side
valve (marked COLD) and the hot water supply to the left valve
(marked HOT).
Open cold and hot water supply and check connections
for leakage!
Maintenance
Inspect and clean all parts, replace as necessary and grease
with special grease.
Shut off cold and hot water supply.
I. Ceramic cartridge, see fig [6].
Secure side valve against sliding back!
1. Remove handle (E).
2. Unscrew the ceramic cartridge (A) using a 17mm wrench.
3. Change complete ceramic cartridge (A) or O-ring (A1).
Observe the different replacement part numbers of the
cartridges.
II. Flow straightener, see fold-out page II.
Unscrew and clean flow straightener (48 270).
Assemble in reverse order.
Replacement parts, see fold-out page II ( * = special
accessories).
Care
Instructions for care of this faucet will be found in the Limited
Warranty supplement.
1
2014/03/21
www.grohe.com
&
+49 571 3989 333
impressum@grohe.de
&
+43 1 68060
info-at@grohe.com
Argent Sydney
&
+(02) 8394 5800
Argent Melbourne
&
+(03) 9682 1231
&
+32 16 230660
info.be@grohe.com
&
+359 2 9719959
grohe-bulgaria@grohe.com
&
+99 412 497 09 74
&
+1 888 6447643
&
+41 448777300
&
+86 21 63758878
&
+357 22 465200
&
+420 277 004 190
grohe-cz@grohe.com
&
+45 44 656800
&
+34 93 3368850
&
+372 6616354
&
+33 1 49972900
marketing-fr@grohe.com
&
+358 10 8201100
teknocalor@teknocalor.fi
&
+44 871 200 3414
&
+30 210 2712908
nsapountzis@ath.forthnet.gr
&
+36 1 2388045
&
+852 2969 7067
&
+39 2 959401
&
+91 124 4933000
&
+354 515 4000
&
+81 3 32989730
&
+7 727 311 07 39
&
+372 6616354
LV
&
+372 6616354
grohe@grohe.ee
MAL
&
+1 800 80 6570
info-singapore@grohe.com
N
&
+47 22 072070
grohe@grohe.no
NL
&
+31 79 3680133
NZ
&
+09/373 4324
P
&
+351 234 529620
PL
&
+48 22 5432640
RI
&
+62 21 2358 4751
info-singapore@grohe.com
RO
&
+40 21 2125050
info-ro@grohe.com
ROK
&
+82 2 559 0790
info-singapore@grohe.com
RP
&
+63 2 8041617
RUS
&
+7 495 9819510
info@grohe.ru
S
&
+46 771 141314
SGP
&
+65 6 7385585
info-singapore@grohe.com
SK
&
+420 277 004 190
T
&
+66 2610 3685
info-singapore@grohe.com
TR
&
+90 216 441 23 70
UA
&
+38 44 5375273
info-ua@grohe.com
USA
&
+1 800 4447643
us-customerservice@grohe.com
VN
&
+84 8 5413 6840
info-singapore@grohe.com
BiH
AL
HR
KS
ME
MK
SLO
SRB
&
+385 1 2911470
Eastern Mediterranean,
Middle East - Africa
Area Sales Office:
&
+357 22 465200
IR
OM
UAE YEM
&
+971 4 3318070
grohedubai@grome.com
Far East Area Sales Office:
&
+65 6311 3600
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

GROHE 19347BE1 Installation guide

Category
Faucets
Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI