LG ARNH763K3B2.ANWALUS Installation guide

Category
Split-system air conditioners
Type
Installation guide
INSTALLATION MANUAL
AIR CONDITIONER
• Please read this installation manual completely before installing the product.
• Installation work must be performed in accordance with the national wiring
standards by authorized personnel only.
• Please retain this installation manual for future reference after reading it
thoroughly.
TYPE : (For High Temperature)
Hydro Kit
P/NO : MFL67212806
http://www.lghvac.com
www.lg.com
ENGLISH
FRANÇAIS
ESPAÑOL
Hydro Kit
Installation Manual
TABLE OF CONTENTS
1. Safety Precautions.......................................................................................................................3
2. Installation Parts..........................................................................................................................6
3. General Information.....................................................................................................................7
Model Information ..........................................................................................................................7
4. Installation....................................................................................................................................8
Transporting the Unit .....................................................................................................................8
Selection of the best location.........................................................................................................9
Installation Space ..........................................................................................................................9
Foundation for Installation ...........................................................................................................10
Water Piping and Water Circuit Connection.................................................................................11
Water Tank Temperature Sensor ................................................................................................15
Installation Scenes.......................................................................................................................16
Refrigerant Piping ........................................................................................................................18
How to connect wirings................................................................................................................20
Wiring Connection .......................................................................................................................20
Connecting Cables ......................................................................................................................21
5. Accessories Installation............................................................................................................22
Location of Accessories and External Parts Connection .............................................................22
Water Pump Interlock Wiring (Filed Provided).............................................................................25
Water tank temperature sensor Connection ................................................................................25
Thermostat...................................................................................................................................26
Remote Temperature Sensor.......................................................................................................28
3Way Valve ..................................................................................................................................29
Dry Contact..................................................................................................................................30
6. System Set-Up............................................................................................................................31
DIP Switch Setting .......................................................................................................................31
Group Control Setting ..................................................................................................................32
Installer Setting ............................................................................................................................36
Installing recirculation pump ........................................................................................................44
Setting temperature unit ..............................................................................................................44
Installing Thermostat ...................................................................................................................45
Installing 2Way Valve...................................................................................................................46
7. Test Run......................................................................................................................................47
Caution before Operation Test.....................................................................................................47
Operation Test of Water Pipe.......................................................................................................47
Troubleshooting ...........................................................................................................................48
2
Hydro Kit
Do not modify or extend the
power cable.
• There is risk of fire or electric
shock.
Do not install, remove, or
reinstall the unit by yourself
(customer).
• There is risk of fire, electric
shock, explosion, or injury.
For antifreeze, always con-
tact the dealer or an author-
ized service center.
Almost the antifreeze is a toxic
product.
The refrigerant of this unit is R134a and
the unit is connected to the outdoor unit
where R410A refrigerant is used.
The installation tool such as manifold
gauge should comply with R410A.
For installation, always con-
tact the dealer or an
Authorized Service Center.
• There is risk of fire, electric
shock, explosion, or injury.
Do not install the unit on a
defective installation stand.
• It may cause injury, accident,
or damage to the unit.
Safety Precautions
1. Safety Precautions
To prevent injury to the user or other people and property damage, the following instructions must be fol-
lowed.
Be sure to read before installing the unit.
Be sure to observe the cautions specified here as they include important items related to safety.
Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is classified
by the following indications.
Meanings of symbols used in this manual are as shown below.
This symbol indicates the possibility of death or serious injury.
This symbol indicates the possibility of injury or damage to properties only.
Installation
Be sure not to do.
Be sure to follow the instruction.
Do not use a defective or
underrated circuit breaker.
Use this appliance on a ded-
icated circuit.
• There is risk of fire or electric
shock.
For electrical work, contact
the dealer, seller, a qualified
electrician, or an Authorized
Service Center.
• There is risk of fire or electric
shock.
Always ground the unit.
• There is risk of fire or electric
shock.
Install the panel and the cover
of control box securely.
• There is risk of fire or electric
shock.
Always install a dedicated
circuit and breaker.
• Improper wiring or installation
may cause fire or electric
shock.
Use the correctly rated
breaker or fuse.
• There is risk of fire or electric.
ENGLISH
Hydro Kit Installation Manual 3
Safety Precautions
Operation
Take care to ensure that
power cable could not be
pulled out or damaged dur-
ing operation.
• There is risk of fire or electric
shock.
Do not place anything on
the power cable.
• There is risk of fire or electric
shock.
Do not plug or unplug the power
supply plug during operation.
• There is risk of fire or electric
shock.
Do not touch (operate) the
unit with wet hands.
• There is risk of fire or electric
shock.
Do not place a heater or other
appliances near the power cable.
• There is risk of fire or electric
shock.
Do not allow water to run
into electric parts.
• There is risk of fire, failure of
the unit, or electric shock.
Do not store or use flammable
gas or combustibles near the
unit.
• There is risk of fire or failure
of unit.
Do not use the unit in a
tightly closed space for a
long time.
• It may cause damage to the
unit.
When flammable gas leaks,
turn off the gas and open a
window for ventilation
before turning the unit on.
• There is risk of explosion or
fire.
If strange sounds, or small or
smoke comes from unit, turn the
breaker off or disconnect the
power supply cable.
• There is risk of electric shock
or fire.
Stop operation and close the window
in storm or hurricane. If possible,
remove the unit from the window
before the hurricane arrives.
• There is risk of property dam-
age, failure of unit, or electric
shock.
Do not open the front cover of
the unit while operation. (Do not
touch the electrostatic filter, if
the unit is so equipped.)
• There is risk of physical injury,
electric shock, or unit failure.
When the unit is soaked
(flooded or submerged),
contact an Authorized
Service Center.
• There is risk of fire or electric
shock.
Be cautious that water could
not be poured to the unit
directly.
• There is risk of fire, electric
shock, or unit damage.
Ventilate the unit from time to
time when operating it
together with a stove, etc.
• There is risk of fire or electric
shock.
4
Hydro Kit
Do not install the unit outside.
• It may cause damage to the unit.
Use a vacuum pump or inert (nitrogen) gas when
doing leakage test or purging air. Do not compress
air or oxygen and do not use flammable gases.
• There is the risk of death, injury, fire or explosion.
Be sure the installation area does not deteri-
orate with age.
• If the base collapses, the unit could fall with it,
causing property damage, unit failure, and per-
sonal injury.
Do not install the water pipe system as
Open loop type.
• It may cause failure of unit.
Turn the main power off
when cleaning or maintain-
ing the unit.
• There is risk of electric shock.
Take care to ensure that
nobody could step on or fall
onto the unit.
• This could result in personal
injury and unit damage.
For installation, always con-
tact the dealer or an
Authorized Service Center.
There is risk of fire, electric shock,
explosion, or injury.
If the unit is not used for long
time, we strongly recommend
not to switch off the power sup-
ply to the unit.
There is risk of water freezing.
ENGLISH
Hydro Kit Installation Manual 5
Installation
Always check for gas
(refrigerant) leakage after
installation or repair of unit.
• Low refrigerant levels may cause
failure of unit.
Keep level even when
installing the unit.
• To avoid vibration or water leak-
age.
Use two or more people to
lift and transport the unit.
• Avoid personal injury.
Safety Precautions
Operation
Do not use the unit for special
purposes, such as preserving
foods, works of art, etc.
• There is risk of damage or loss of
property.
Use a soft cloth to clean.
Do not use harsh deter-
gents, solvents, etc.
• There is risk of fire, electric
shock, or damage to the plastic
parts of the unit.
Do not step on or put any-
thing on the unit.
• There is risk of personal injury
and failure of unit.
Use a firm stool or ladder
when cleaning or maintain-
ing the unit.
• Be careful and avoid personal
injury.
Installation Parts
6
Hydro Kit
2. Installation Parts
Thank you for choosing LG Electronics Hydro Kit.
Before starting installation, please make it sure that all parts are found inside the unit box.
Item Image Quantity
Installation Manual
1
Owner's Manual 1
Remote Controller
/ Cable
1
Sensor Holder 1
Water Tank
Temperature Sensor
1
Conduit mounting plate 2
P/NO : MFL67212802
www.lg.com
INSTALLATION MANUAL
AIR CONDITIONER
ţPlease read this installation manual completely before installing the product.
ţInstallation work must be performed in accordance with the national wiring
standards by authorized personnel only.
ţPlease retain this installation manual for future reference after reading it
thoroughly.
TYPE :
(For High Temperature)
Hydro Kit
OWNER’S MANUAL
AIR CONDITIONER
Please read this manual carefully before operating
your set and retain it for future reference.
P/NO : MFL67212703
www.lg.com
TYPE : (For High Temperature)
Hydro Kit
General Information
Model Information
With advanced inverter technology, Hydro Kit is suitable for applications like under floor heat-
ing, and hot water generation. By Interfacing to various accessories user can customize the range
of the application.
ENGLISH
Hydro Kit Installation Manual 7
Model name and related information
*1 : Tested under Eurovent Heating condition
(water temperature 55˚C(131˚F) 65 ˚C(149˚F) at outdoor ambient temperature
7℃(44℉) / 6℃(42℉))
Type
Hydro Kit
(For High Temperature)
Model Unit ARNH763K3B2
Power Supply Ø, V, Hz 1, 208/230, 60
Capacity Heating
kW 25
kcal/h
21500
Btu/h 85300
Net Weight kg(lbs) 94(207)
Refrigerant
Type R134a
Quantity kg(lbs) 3(6.61)
Noise Level dB 43
3. General Information
8
Hydro Kit
Installation
Transporting the Unit
• When carrying the suspended unit, pass the ropes between legs of base panel under the unit.
• Always lift the unit with ropes attached at six points so that impact is not applied to the unit.
Attach the ropes to the unit at an angle of 40° or less.
• Use only accessories and parts which are of the designated specification when installing.
40º or less
Line supporter
CAUTION
Be very careful while carrying the unit.
- Do not have only one person carry the unit if it is more than 20 kg (44.1 lbs).
- PP bands are used to pack some products. Do not use them as a mean for transportation because
they are dangerous.
- Tear plastic packaging bag and scrap it so that children cannot play with it. Otherwise plastic pack-
aging bag may suffocate children to death.
- When carrying the unit, be sure to support it at 6-points. Carrying and lifting the unit with 3-point
support may make it unstable, resulting in a fall.
4. Installation
Installation
ENGLISH
Hydro Kit Installation Manual 9
1. Select space for installing the unit, which will meet the following conditions:
• The place where the unit shall be installed inside.
• The place shall easily bear a load exceeding four times of the unit weight.
• The place where the unit shall be leveled.
• The place shall allow easy water drainage.
• The place where the unit shall be connected to the outdoor unit.
• The place where the unit is not affected by an electrical noise.
• The place where there should not be any heat source or steam near the unit.
Installation Space
• The following values are the least space for installation.
If any service area is needed for service according to field circumstance, obtain enough service
space.
• The unit of values is mm(inch).
(Unit: mm(inch))
400(15-3/4)520(20-15/32)300(11-13/16)
Service space
(front side)
330(13)600(23-5/8) 100(3-15/18)
Piping space
(front side)
Service space
(left side)
100
(3-5/16)
100
(3-5/16)
100
(3-5/16)
100
(3-5/16)
1080(42-17/32)1080(42-17/32)
200(7-7/8)
H-Beam supporter
Concreate supporter
Base pad
space
Anti vibration material)
(Unit: mm(inch)
Selection of the best location
Installation
10
Hydro Kit
Foundation for Installation
• Fix the unit tightly with bolts as shown below so that the unit will not fall down due to earthquake.
• Noise and vibration may occur from the floor or wall since vibration is transferred through the
installation part depending on installation status. Thus, use anti-vibration materials (cushion pad)
fully (The base pad shall be more than 200 mm (7-7/8 inch)).
75(2-15/16)
Flat washer
Anchor bolt
Spring washer
Nut
Anti-vibration material
Concrete
base
Support
3 or more screw
threads of the
2 bolts must be
shown
(Unit: mm(inch))
354(13-15/16)
392(15-7/16)
Installation
ENGLISH
Hydro Kit Installation Manual 11
General Considerations
Followings should be considered before beginning water circuit connection.
• Service space should be secured.
• Water pipes and connections should be cleaned using water.
• Space for installing external water pump should be provided.
• Turn the power off to the unit while filling the water piping.
Water Piping and Water Circuit Connection
While installing water piping, followings should be considered :
While inserting or putting water pipes, close the end of the pipe with pipe cap to avoid dust entering.
• When cutting or welding the pipe, always be careful that inner section of the pipe should not be
defective. For example, no weldments or no burrs are found inside the pipe.
• Pipe fittings (e.g. L-shape elbow, T-shape tee, diameter reducer, etc) should be tightened
strongly to be free from water leakage.
• Connected sections should be leakage-proof treatment by applying tefron tape, rubber bushing,
sealant solution, etc.
Appropriate tools and tooling methods should be applied to prevent mechanical breakage of the connections.
• Operation time of flow valve(e.g. 3way valve) should be less than 90 seconds.
• Wrap all cold surfaces of the pipe system individually with insulation sized to keep condensation
from forming on the pipes in the installed environment. For proper size insulation, use guidelines
provided by the insulation manufacturer.
Water Piping and Water Circuit Connection
Installation
12
Hydro Kit
On-site installation (1)
Hydro kit
(For High Temperature)
Union joint (2) Thermometer (6) Excessive pressure
safety valve(10)
Pressure gauge(7) Shut-off valve (9)
Drain valve(8)Strainer(4)P/T Service port(3)
Air vent (5)
[Install water tank]
[Install floor heating]
Outlet Water
or
Inlet water
Water cycle
* For the water pipe system, use the closed loop type.
1. Select parts whose pressure specifications are greater the operating water pressure for protec-
tion against excessive pressure
2. For the water pipe, use anti-corrosion steel pipe or copper pipe.
3. To replace the connected device easily, install the union joint (2).
4.
Install the service port (3) to clean the heat exchanger at each inlet and outlet of the water pipe.
5. Always install a strainer (4) at the inlet of the water pipe.
- For the strainer, use one with 50 mesh or above with measurement diameter of 0.4mm or
less. (Exclude other net)
- Always install the strainer on the horizontal pipe.
(When dirt, trash, rusted pieces get into the water pipe system, it can cause problems to the
product by corroding the metallic material.)
6. Install the air vent (5) at the top of the water pipe.
7. Install a thermometer (6) and pressure gauge (7) at the inlet and outlet of the water pipe.
8. Install the drain valve (8) that can be used for draining the water inside when replacing the part
or providing service.
9. Install the shut-off valve (9) to block the water by closing the valve when replacing the part or
cleaning.
10. Apply insulated treatment on the exterior of the water pipe so that condensation do not form.
11. Install a pressure relief valve (10) that meets the design water pressure to prevent unit or
water pipe damage at the pressure increase inside the water pipe system.
12. There is a drain hole at the bottom of the Hydro Kit to prevent risk of electric shock caused by
leakage of water.
Installation
ENGLISH
Hydro Kit Installation Manual 13
* Water tank & Floor heating installation
1. Use the pump (1) with sufficient capacity to assure loss of overall water pressure and to supply
water to the
Hydro Kit
.
2. Install the shut-off valve (2) on both sides of the pump to clean and repair the pump.
3. Install the flexible joint (3) to prevent noise and vibration transferred from the pump.
4. Install the pressure gauge (4) to monitor the water pressure from water tank. (Option)
5. Install the expansion tank (5) to accommodate the water contracted or expanded from the temper-
ature difference and to supply the water.
6. After the installation of water pipe system is completed, open the water supply valve (6) and sup-
ply the water.
7. When installing the water tank, insert the water tank temperature sensor (7) to measure the tem-
perature of the water inside the tank.
- For the water tank temperature sensor, use the sensor supplied on the product.
- When heating the floor, measure the space air temperature by remote temperature sensor
(Separately sold).
8. Use the water tank (9) with the heat exchange coil (8) installed so that the heat can be exchanged
sufficiently inside the tank.
Installation of water tank
Installation of floor heating
shut-off valve (2)
shut-off valve (2)
Pump (1)
Flexible joint (3) : Optional
Pressure gauge (4)
Water supply valve (6)
Pump (1)
Flexible joint (3) : Optional
Pressure gauge (4)
Water supply valve (6)
water tank (9)
(Indirect heating type)
Floor heating coil
(Radiator, FCU can be used)
Expansion tank (5)
Expansion tank (5)
Heat
exchange
coil (8)
water tank
temperature sensor (7)
Installation
14
Hydro Kit
Strainer
- Use the 50 mesh strainer.
(Exclude scale diameter of 0.4mm or less and other net)
- Check the strainer direction and assemble on the inlet hole (Refer to picture)
- Wrap the Teflon tape on the screw thread of the water pipe for more than 15 times for assembly.
- Install the service port facing downward. (Within left/right 45 degrees)
- Check if there is any leakage on the connecting part.
- Clean the strainer.
Water In
Strainer
Front Side
45°
Installation
ENGLISH
Hydro Kit Installation Manual 15
Installation Condition
Installing Domestic Hot Water tank requires following considerations :
• Domestic Hot Water tank should be located at the flat place.
• Water quality should comply with local or international plumbing code.
• As this water tank is Domestic Hot Water tank (indirect heat exchange), do not use anti water-
freezing treatment like ethylene grycol.
• It is highly recommend to wash out inside of the Domestic Hot Water tank after installation. It
ensures generating clean hot water.
• Near the Domestic Hot Water tank, there should be water supply and water drain for easy access
and maintenance.
PT 1/2 inch
Process PT 1/2 inch
female bolt
Sensor holder cap
Inside water tank
Water tank outer wall
Water Tank
Temperature Sensor
Sensor
holder
• If hot water mode is used, make sure to install
sensor to water tank.
• Make PT1/2 inch female bolt hole in the water
tank, and install sensor in the water tank.
• Insert the sensor deeply into the hole of the sen-
sor holder cap and use thermal paste.
• Lock the sensor holder cap.
Water Tank Temperature Sensor
Domestic Hot
Water tank
Water Tank
Temperature Sensor
Water In
Water Out
Water tank temperature sensor connection
Installation
16
Hydro Kit
Installation Scenes
Some installation scenes are presented for example. As these scenes are conceptual figures,
installer should optimize the installation scene according to the installation conditions.
1) Floor Heating only
2) Floor Heating + Hot water
3) Hot water only
Floor heating loopFan coil unit
Radiator
Floor heating loopFan coil unit
Domestic
Hot Water
tank
Hot water
City water
Radiator
Domestic
Hot Water
tank
Hot water
City water
Pump
3way valve
Bypass valve
Installation
ENGLISH
Hydro Kit Installation Manual 17
Water Quality
Water quality should comply with EN 98/83 EC Directives. Requirement for resolved chemical ingre-
dients is following table. Detailed water quality condition can be found in EN 98/83 EC Directives.
Frost protection
In areas of the country where entering water temperatures drop below 0℃(32℉), the water pipe must
be protected by using an approved antifreeze solution. Consult your
Hydro Kit
unit supplier for local-
ly approved solutions in your area. Calculate the approximate volume of water in the system. (Except
the
Hydro Kit
unit.)
And add antifreeze solution to the total volume to allow for the water contained in
Hydro Kit
unit.
Parameter Value
Acrylamide 0.10 μg/l
Antimony 5.0 μg/l
Arsenic 10 μg/l
Benzene 1.0 μg/l
Benzo(a)pyrene 0.010 μg/l
Boron 1.0 mg/l
Bromate 10 μg/l
Cadmium 5.0 μg/l
Chromium 50 μg/l
Copper 2.0 mg/l
Cyanide 50 μg/l
1.2-dichloroethane 3.0 μg/l
Epichlorohydrin 0.10 μg/l
Parameter Value
Fluoride 1.5 mg/l
Lead 10 μg/l
Mercury 1.0 μg/l
Nickel 20 μg/l
Nitrate 50 mg/l
Nitrite 0.50 mg/l
Pesticides 0.10 μg/l
Pesticides — Total 0.50 μg/l
Polycyclic aromatic hydrocarbons 0.10 μg/l
Selenium 10 μg/l
Tetrachloroethene and Trichloroethene 10 μg/l
Trihalomethanes — Total 100 μg/l
Vinyl chloride 0.50 μg/l
CAUTION
• If the unit is installed at existing hydraulic water loop, it is important to clean hydraulic pipes to remove
sludge and scale.
• Installing sludge strainer in the water loop is very important to prevent performance degrade.
• Chemical treatment to prevent rust should be performed by installer.
CAUTION
1. Use only one of the above antifreeze.
2. If a antifreeze is used, pressure drop and capability degradation of the system can occur.
3. If one of antifreezes is used, corrosion can occur. So please add corrosion inhibitor.
4. Please check the concentration of the antifreeze periodically to keep same concentration.
5. When the antifreeze is used (for installation or operation), take care to ensure that antifreeze
must not be touched.
6. Ensure to respect all laws and norms of your country about Anti-freeze usage.
Type of Antifreeze
Minimum Temperature for Freeze Protection
0℃(32℉) -5℃(23℉) -10℃(14℉) -15℃(5℉) -20℃(-4℉) -25℃(-13℉)
Ethylene glycol 0% 12% 20% 30% - -
Propylene glycol 0% 17% 25% 33% - -
Methanol 0% 6% 12% 16% 24% 30%
Installation
18
Hydro Kit
Cut the pipes
- Use the accessory piping kit or the pipes
purchased locally.
- Measure the distance between the indoor
and the outdoor unit.
- Cut the pipes a little longer than measured
distance.
Burrs removal
- Completely remove all burrs from the cut
cross section of pipe/tube.
- Put the end of the copper tube/pipe to down-
ward direction as you remove burrs in order
to avoid to let burrs drop in the tubing.
Pipe brazing
- Always make sure to flow Nitrogen at
0.2kgf/cm
2
within the pipe when while braz-
ing.
-
If the brazing is done without flowing Nitrogen,
it can generate a thick oxidized coating within
the pipe to interfere with normal operation of
valve and compressor etc.
Insulation
- Use insulation material with high thermal re-
sistance and rated for the anticipated operat-
ing temperature range.
- When installed in humid environment, use
thicker insulation material as specified by
system designer
Copper
tube
90°
Slanted Uneven Rough
Pipe
Reamer
Point down
Copper tube
Direction of Nitrogen
Regulator
Taping
Valve
Nitrogen
Nitrogen
Nitrogen
Panel
Inside product
Insulation
Copper
tube
Refrigerant Piping
Installation
ENGLISH
Hydro Kit Installation Manual 19
Precaution when connecting Heat Recovery systems
Pipe searching process
1. When pipe searching process is performed,
- Use ‘Mode 1’ if water temperature is higher than 30℃(86℉)
- Use ‘Mode 2’ if water temperature is lower than 30℃(86℉)
2. When pipe searching process is not performed,
- Check whether ‘CH14’ error occurs in the Hydro Kit.
*Refer to the installation manual of HR unit
No.1, 2 Valve
/
No.3, 4 Valve
Control
No.3, 4 Valve
Control
DIP S/W setting
No.2, 3 Valve
Control
No.1, 2 Valve
Control
No Hydro kits
connected
Example
Indoor Unit
Indoor Unit
Hydro kit
Indoor Unit
Indoor Unit
Hydro kit
Indoor Unit
Indoor Unit
Hydro kit
Hydro kit
Hydro kit
Indoor Unit
Indoor Unit
Indoor Unit
Indoor Unit
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
Gas pipe
Ø15.88
Liquid pipe
Ø9.52
Welding type
Hydro kit
Gas pipe
Ø22.2
Liquid pipe
Ø9.52
(When two
Hydro Kit are
installed)
- One connection of refrigerant pipe for HR unit is
insufficient for the flow of refrigerant. Join two
pipes with a branch pipe when connecting the
Hydro Kit.
- The pipe number of the connected gas pipe and
liquid pipe must be same.
- Flow water in the Hydro Kit when pipe-
searching process is performed.
- Pipe-searching process error may occur if the
pipe temperature does not increase.
- It is recommended that Hydro Kit is connect-
ed to No.1 valve and No.2 valve.
Recaution when connecting to synchronous type outdoor unit
Installation
20
Hydro Kit
Connect the wires to the terminals on the control board individually according to the outdoor unit
connection.
*Ensure that the wire color of the outdoor unit and terminal No. are same as those of the indoor unit
respectively.
Communication cable
Power cable
Earth
3(A)
L(L1) N(L2)
4(B)
Terminal block
of indoor unit
Terminal block
of indoor unit
Terminal block of outdoor unit
Outdoor unit
Indoor unit
DRY2DRY1
WARNING : Verify terminal screws are thoroughly tightened.
Remove the box cover of electric parts and connect the wiring
CAUTION
After checking the above status, prepare for the following wiring :
1)
Use individual power for the unit and refer to the circuit diagram posted on the inside of the control cover.
2) Use a properly sized circuit breaker with the Hydro kit.
3) The bolts used for cable connection may become loose by the vibration generated during the trans-
portation. Make sure to check again and fasten them tightly. (If they are loose, it may cause fire.)
4) Verify the power supply is within the tolerance range of the nameplate value ±10%
5) Electrical capacity shall be sufficient.
6) The initial voltage shall be maintained at 90% of the rated voltage on the name plate.
7) The size of the power wiring complies with the designated specification. (length and thickness of the
power cable)
8) Do not install the circuit breaker in the place where there is a lot of moisture or where it is wet.
9) The following problems may be the cause of voltage drop.
-
Magnetic switch vibration, defective contact, fuse damage, malfunction of overload protection device
Based on the owners manual, teach how to operate and use the unit to the user.
(temperature setting, etc.)
Wiring Connection
CAUTION
When connecting the power and communication
cable, always use the terminal connector (O-
ring, Y-ring).
Make sure to tighten so that the screw of the ter-
minal does not get loose.
How to connect wirings
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51

LG ARNH763K3B2.ANWALUS Installation guide

Category
Split-system air conditioners
Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI