Schneider Electric PIR Motion Sensor Instruction Sheet

Type
Instruction Sheet
(1) (3)(2) (4)
(1) (2)
1.2 m
Side viewTop view
0 8 9
m
8 9
110°
m
0 9
m
Less sensitive to radial movementHighly sensitive to cross movement
(3)
(1)
L
N
L L’N N
Load
(2)
L
N
L L’N N L L’N N
Load
(3)
L
N
LL’NN Load
Staircase timer
Push
button
N
t
Ein
!
§
(1) (3)
(6)
(4)
Lux
(2)
ON AUTO OFF
(5)
(7) a. (7) b. (7) c.
Meter
+-
Time
20 min 6 sec
Test
1S.
Finish
Start
Walk test
LED
AUTO ON OFF
$
(1) (2)
%
$ Operation
(1) Open up the knob cover:
slightly.
(2) Knob setting:
To adjust Time, Lux, Meter knobs refer to the
following steps and make sure the slide switch is
at the position “AUTO”.
(3) Lux knob setting
a. Setting Lux knob value at the position “ ”,
means sensor can work in the dark only.
b. Setting Lux knob value at the position “ ”,
means sensor can work at any light level.
c. Adjusting the Lux knob according to your desire.
(4) Time knob setting
a.
b.
c.
(5) Meter knob setting
a. Setting Meter knob value at the position “-”,
performed.
b. Setting Meter knob value at the position
performed.
c. Adjusting the Meter knob according to your
desire in between the position “-” and “+”.
(6) Walk test
Note: It takes 30 secs for sensor to warm up
with LED and load turn on, then enters into
standby mode. The purpose of conducting a
walk test is to select a proper location to get the
best detection range. Set the slide switch at the
position “AUTO”, turn Meter knob to “+”, Time
knob to “test”, then conduct a walk test referring
to below steps:
Install the sensor correctly, to make sure wiring is
connected correctly.
Switch on the power.
Walk from outside across to the detection pattern,
once the sensor is triggered, Led and load will all
turn on for 2 sec.
Adjust Meter knob to targeted coverage.
Repeat the above steps until it meets your needs.
Pay attention to the walking direction while
proceeding the test.
Use the Red LED behind the lens for indication.
Lux setting value is disabled.
(7) Manual switch function
a. AUTO: Set slide switch at the middle position
(AUTO), sensor is in auto operation mode. If time
knob is set between 6 sec and 20 min, LED will
turn on for 1 sec once the sensor is triggered.
b. ON: Set the slide switch leftward, “ON” mode is
activated, load will be permanent on with LED
c. OFF: Set the slide switch rightward, “OFF” mode
% Unmounting the sensor
(1) Insert a screwdriver between the cover frame
and the wall surface to remove the cover frame.
Then twist the screwdriver to disassemble the
cover frame from the sensor.
(2) Use the other hand to support and remove the
cover frame.
en PIR Motion Sensor
About this product
The PIR Motion Sensor (hereinafter referred to as
Sensor) is 110° wall mounted. It is ideally located in
as corridors, staircases, dining rooms, cellars, drawing
rooms, bedrooms, garages, etc. Additionally, it has the
following features:
Suitable for a normal wall box for easy installation
and operation.
modes of function.
Screw-in terminal block for easy and safe wire
connection.
Replace two-way switch of staircase by PIR
Motion Sensor to make the operation fully
automatic.
Energy saving: Built-in photocell allows automatic
operation at night and in daylight.
!Mounting the sensor
CAUTION
HAZARD OF EQUIPMENT DAMAGE
Bulb burn of certain brands would cause high
inrush current which might damage the unit
permanently.
Circuit breakers are recommended to be installed
upfront for safety precaution.
Failure to follow these instructions can result in
injury or equipment damage.
(1) Mount the wall box to the wall.
(2) Connect the wires to the sensor.
(3) Place the sensor on the wall box and secure it
using the screws on both sides.
(4) Assemble the cover frame on the sensor,
ensuring proper engagement by hearing a clear
“click.”
Choose a suitable location to install
(1) Detection coverage: It is recommended to install
the sensor at the height of 0.8 m to 1.5 m. At the
height of 1.2 m, the detection range is up to 9 m
frontward and 8 m sideward.
(2) Installation tips: Since the sensor is respondent
to temperature change, please avoid the
following conditions:
a. Directing the sensor towards the objects whose
monitors, etc.
b. Mounting the sensor near the heat sources,
such as heating vents, air conditioners, vents as
dryers, lights, etc.
c. Aiming the sensor towards the objects which
may be sway in the wind, such as curtains, tall
plants, miniature garden, etc.
(3) Pay attention to the walking direction during the
test.
§Wiring diagram
DANGER
HAZARD OF ELECTRIC SHOCK, EXPLOSION,
OR ARC FLASH
Safe electrical installation must be carried out only
by skilled professionals. Skilled professionals must
prove profound knowledge in the following areas:
Connecting to installation networks.
Connecting several electrical devices.
Laying electric cables.
Safety standards, local wiring rules and
regulations.
Failure to follow these instructions will result in
death or serious injury.
(1) Normal Operation
(2) Two sensors control one load
(3) One sensor controls staircase timer (Set time
knob to 1s. )
Time: Adjustable from 6 sec to 20 min. Set the
time knob between 6 sec to 20 min. LED will turn
on for 1 sec once the sensor is triggered.
Test: Walk test operation. Set the Time knob at
“test”, once the sensor is triggered, both of load
next trigger should be 2 sec interval. Lux setting
value is disabled.
1S.
: Short impulse for staircase timer switch
1S.
“ ”, once the sensor is triggered, both of load
next trigger should be 9 sec interval.
Troubleshooting
Problem Possible cause Suggested solution
LED does
not turn on.
Power is not
switched on.
Switch on the power.
Wire is connected
incorrectly.
Refer to wiring
diagrams and
connect wiring
correspondingly.
Load does
not turn on.
Wire is connected
incorrectly.
Refer to wiring
diagrams and
connect wiring
correspondingly.
Defective load.Replace the defective
load with a new one.
Meter setting is too
short.
Setting Meter knob
to “+.
The slide switch is
at OFF”.
Adjust slide switch at
AUTO” or ON”.
Load does Time setting is
too long, sensor
is continuously
triggered.
Set time in test mode,
check whether the
sensor is nuisance
triggered.
Sensor is nuisance
triggering.
Keep away from
the detection zone
to avoid activating
sensor.
Wire is connected
incorrectly.
Please check if load is
connected correctly.
Nuisance
triggering
There are heat
sources or any
objects which may
be swayed in the
wind within the
Avoid aiming the sen-
sor toward any heat
sources, such as air
conditioners, electric
fans, heaters, or
objects. Make sure
there are no swaying
objects within the
Note:
Do not attempt to open or repair the unit without
The following conditions may cause lower
sensitivity:
In very hot days, the sensitivity may be less
since high ambient temperature is close to body
temperature.
In very cold days when heavy clothing is dressed,
especially the facial area is covered, very little
heat will be emitted from the body causing the unit
to be less sensitivity.
Cleaning: Wipe with dry cloth only. Soap or rough
cloth may damage the sensor lens.
Care
1. Use a soft damp cloth/tissue to remove dust or dirt.
2.
cleaning.
3. Do not use caustic cleaning agents.
Technical data
Rated Voltage 230 Vac
Detection Angle Up to 110°
Detection Range About 9 m for frontward, 8 m each
for sideward at the height of 1.2 m
(20 to 25 °C)
Mounting Height 0.8 to 1.5 m (optimal mounting
height: 1.2 m)
Lux Adjustment Adjustable from “ ” (about 5 Lux)
to “☼” (∞)
“test” & “ 1S ”
Meter Adjustable for detection zones
Manual Switch (3 modes) Manual on permanently / AUTO / OFF
Environmental Protection IP40
Operating Temperature 0 to 45 °C
Dimensions 98 x 101 x 40.70 mm
Types of load
Incandescent Lamp 2000 W maximum
AC Halogen Lamp 1000 W maximum
LV Halogen Lamp 1000 VA maximum (electronics
and traditional)
Fluorescent Lamp 900 VA maximum / 100 µF
(compensated)
Energy saving Lamp
(include CFL and PL Lamp)
600 VA maximum
Schneider Electric Industries SAS
If you have technical questions, please contact the
Customer Care Centre.
Customer Care: 1800 103 0011
Mktd. by: Schneider Electric India Pvt. Ltd.,
C56, Mayapuri Industrial Area, Phase II,
New Delhi - 110064, India.
Mfg. by: Schneider Electric India Pvt. Ltd.,
A9/10, Nimblak Road, MIDC, Nagapur,
Ahmednagar 414111, Maharashtra, India
UNSPIR_xx PIR Motion Sensor
en
MFR3778401-03 07/23
  • Page 1 1

Schneider Electric PIR Motion Sensor Instruction Sheet

Type
Instruction Sheet

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI