MrSteam Mechanical Blowdown Timer Installation & Operation Manual

Type
Installation & Operation Manual

MrSteam Mechanical Blowdown Timer is a device that can be used to automate the blowdown process of a boiler. It features a 24-hour and 7-day timer that allows you to set specific times for the boiler to be turned on and off. This can help to improve the efficiency of the boiler by reducing the amount of time that it is running unnecessarily. The timer also has a manual override switch that allows you to turn the boiler on or off at any time, regardless of the timer settings. This can be useful for troubleshooting or for performing maintenance on the boiler.

Here are some of the possible use cases for the MrSteam Mechanical Blowdown Timer:

MrSteam Mechanical Blowdown Timer is a device that can be used to automate the blowdown process of a boiler. It features a 24-hour and 7-day timer that allows you to set specific times for the boiler to be turned on and off. This can help to improve the efficiency of the boiler by reducing the amount of time that it is running unnecessarily. The timer also has a manual override switch that allows you to turn the boiler on or off at any time, regardless of the timer settings. This can be useful for troubleshooting or for performing maintenance on the boiler.

Here are some of the possible use cases for the MrSteam Mechanical Blowdown Timer:

PUR 100456 4/10
Mechanical Blowdown Timer
PN 103805
___________________________________________________________________________
Operation Instructions
24-HOUR AND 7-DAY TIMER
NOTE: The Time Clock controls boiler operation. The boiler is on when the timer is on. The Blowdown
Valve will open when the Timer turns the Boiler off.
PROGRAMMING
For boilers equipped with Automatic Blowdown Systems 81500 and
81600, refer to the following instructions for time clock operation
and settings.
Timer settings for blowdown operation are at the discretion of the
owner/operator. Please refer to the Boiler Installation, Operation
and Maintenance Manual for recommended blowdown operation.
The weekly program dial shows the seven days of the week and
AM/PM imprints for each day.
The timer is set by pushing the captive trippers to the outer ring
position for the entire period that the boiler is to be turned ON, i.e., 2 hours to each tripper on the 7-
day dial. When the
tripper is pushed to the inside, the switch is in the OFF position.
SETTING TIME
To set the current time and day of week, turn the minute hand clockwise
Do not set the time by rotating “Outer”Dial.
Turn the minute hand clockwise until the day of the week and the time of day on
the outer dial is aligned with the triangle marker on the inner dial (two o'clock).
Example for 7-day program dial Monday 10:30 AM. Turn the minute hand clockwise
until Monday 10:30 AM is aligned with the triangle on the inner dial.
The hour and minute hand will show exactly 10:30.
FOR MANUAL OVERRIDE
Manual override can be accomplished at the discretion of the owner/operator as follows.
3-WAY MANUAL OVERRIDE SWITCH
I= permanent ON I
= automatic
= permanent OFF
IMPORTANT: It is recommended that for periodic and effective blowdown,
the override switch be set in the automatic setting.
A Division of Sussman-Automatic Corporation
43-20 34th Street, Long Island City, NY 11101 • (718) 937-4500
1-800-238-3535 • Fax: (718) 937-4676 • email: [email protected]
www.sussmanboilers.com
  • Page 1 1

MrSteam Mechanical Blowdown Timer Installation & Operation Manual

Type
Installation & Operation Manual

MrSteam Mechanical Blowdown Timer is a device that can be used to automate the blowdown process of a boiler. It features a 24-hour and 7-day timer that allows you to set specific times for the boiler to be turned on and off. This can help to improve the efficiency of the boiler by reducing the amount of time that it is running unnecessarily. The timer also has a manual override switch that allows you to turn the boiler on or off at any time, regardless of the timer settings. This can be useful for troubleshooting or for performing maintenance on the boiler.

Here are some of the possible use cases for the MrSteam Mechanical Blowdown Timer:

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI