wms-25-RT-HV-M18

Microsonic wms-25-RT-HV-M18 User manual

  • Hello! I am an AI chatbot trained to assist you with the Microsonic wms-25-RT-HV-M18 User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Technical Data
+UB
–UB
Echo
1
4
2
3
U
Transmitter
wms-25... wms-35... wms-130... wms-340... wms-600...
5
24 width A/F
M12x1
M18x1
95
68
5
36 width A/F
84
M30x1.5
M12x1
64
5
36 width A/F
84
M30x1.5
M12x1
64
5
Ø47.5
36 width A/F
102
33
M30x1.5
M12x1
19.5
82
5
36 width A/F
105
36
M30x1.5
M12x1
22.5
Ø65
85
Blind zone 30 mm 65 mm 200 mm 350 mm 800 mm
Operating range 250 mm 350 mm 1,300 mm 3,400 mm 6,000 mm
Maximum range 350 mm 600 mm 2,000 mm 5,000 mm 8,000 mm
Transducer frequency 320 kHz 400 kHz 200 kHz 120 kHz 80 kHz
Resolution, sampling range 0.35 mm 0.18 mm 0.18 mm 0.18 mm 0.18 mm
Angle of beam spread see detection zone see detection zone see detection zone see detection zone see detection zone
Reproducibility ±0.15 % ±0.15 % ±0.15 % ±0.15 % ±0.15 %
detection zones
for different objects:
The dark grey areas represent the
zone where it is easy to recognise
the normal reflector (round bar).
This indicates the typical operating
range of the sensors. The light
grey areas represent the zone
where a very large reflector – for
instance a plate – can still be reco-
gnized. The requirement is an
optimal alignment of the sensor
and reflector.
It is not possible to evaluate ultra-
sonic reflections outside this area.
Round bar ø 10 mm
Plate
0 cm
5 cm
10 cm
15 cm
20 cm
25 cm
30 cm
35 cm
10 cm
5 cm
0 cm
5 cm
10 cm
Round bar ø 10 mm
Plate
0 cm
10 cm
20 cm
30 cm
40 cm
50 cm
60 cm
20 cm
10 cm
0 cm
10 cm
20 cm
35 cm
Round bar ø 10 mm
Plate
0 m
0.4 m
0.8 m
1.2 m
1.6 m
2 m
1.3 m
0.8 m
0.4
m
0 m
0.4
m
0.8
m
Round bar ø 27 mm
Plate
0 m
0.8
1.6
2.4
3.2
4 m
4.8
5.6
3.4
1.6
0.8
0 m
0.8
1.6
Round bar ø 27 mm
Plate
0 m
1.2
m
2.4
m
3.6
m
4.8
m
6 m
7.2
m
8.4
m
2.4
m
1.2
m
0 m
1.2
m
2.4
m
Accuracy Temperature drift 0.17%/K Temperature drift 0.17%/K Temperature drift 0.17%/K Temperature drift 0.17%/K Temperature drift 0.17%/K
Operating voltage UB/Voltage ripple 10 to 30 V DC, reverse polarity protection/±10 %
No-load current 30 mA 30 mA 30 mA 30 mA 30 mA
Housing Brass sleeve, nickel-plated, plastic parts: PBT; Ultrasonic transducer: polyurethane foam, epoxy resin with glass content
Class of protection to EN 6052 IP67 IP67 IP67 IP67 IP67
Type of connection 4-pin initiator plug, brass, nickel-plated
Operating temperature –20 to +70 °C –20 to +70 °C –20 to +70 °C –20 to +70 °C –20 to +70 °C
Storage temperature –40 to +85 °C –40 to +85 °C –40 to +85 °C –40 to +85 °C –40 to +85 °C
Weight 80 g 200 g 200 g 260 g 320 g
Signal input (Transmitter) Controlled by open collector (npn); IC 3 mA, UCE 30 V
Recommended tramsmitted pulse length 25 µs 80 µs 150 µs 300 µs 350 µs
Recommmended measuring cycle time 8 ms 12 ms 20 ms 40 ms 65 ms
Signal output (Echo) Positive-switched (pnp), Imax = 10 mA, short-circuit-proof and reverse polarity protection
Order No. wms-25/RT/HV/M18 wms-35/RT wms-130/RT wms-340/RT wms-600/RT
Operating manual
wms ultrasonic sensor
wms-25/RT/HV/M18 wms-340/RT
wms-35/RT wms-600/RT
wms-130/RT
Product Description
The wms sensors require a connection
to the customer´s own control and si-
gnal evaluation equipment.
Safety Notes
Ԏ
Read the operating manual prior
to start-up.
ԎConnection, installation and ad-
justments may only be carried
out by qualified staff.
Ԏ
No safety component in ac-
cordance with the EU Machine
Directive, use in the area of per-
sonal and machine protection
not permitted.
The wms sensors indicate a blind
zone, in which the distance cannot be
measured. The operating range indi-
cates the distance of the sensor that
can be applied with normal reflectors
with sufficient function reserve. When
using good reflectors, such as a calm
water surface, the sensor can also be
used up to its maximum range. Ob-
jects that strongly absorb (e.g. plastic
foam) or diffusely reflect sound (e.g.
pebble stones) can also reduce the
defined operating range.
Proper Use
wms ultrasonic sensors are used for
non-contact detection of objects.
Installation
Î
Mount the sensor at the place of
fitting.
ÎConnect a connection cable to the
M12 device plug.
Î
Connect the sensor to your own
control and signal evaluation equip-
ment according to Fig. 1.
Signal input »Transmitter«
A signal on the input makes the wms
sensor emitting a sound pulse. For this
a open collector output has to earth
the »transmitter« signal input for the
time given in the technical data table
below.
Signal output »Echo«
The signal output »Echo« subsequent-
ly transmitts all echo signals received
depending on the duration as 1-bit
values (echo yes/no).
34
12
colour
1 +UBbrown
3 –UBblue
4 Echo black
2 Transmitter white
Fig. 1: Pin assignment with view onto the sen-
sor plug and colour code of the connec-
tion cable
microsonic GmbH / Phoenixseestraße 7 / 44263 Dortmund / Germany / T +49 231 975151-0 / F +49 231 975151-51 / E [email protected] / W microsonic.de The content of this document is subject to technical changes. Specifications in this document are presented in a descriptive way only. They do not warrant any product features.
*B7293*MV-DO-074368-784561
/