Whirlpool WGD4800XQ Installation guide

Category
Electric laundry dryers
Type
Installation guide
1
W10514185A
W10514176A-SP
Table of Contents
DRYER SAFETY ................................................................2
INSTALLATION REQUIREMENTS ....................................4
Tools and Parts .................................................................... 4
Location Requirements ...................................................... 4
ELECTRIC DRYER POWER HOOKUP – CANADA ONLY ......... 6
Electrical Requirements ..................................................... 6
Install Leveling Legs ........................................................... 6
GAS DRYER POWER HOOKUP ................................................. 7
Gas Supply Requirements .................................................. 7
Electrical Requirements ..................................................... 9
VENTING ...................................................................................... 9
Venting Requirements ......................................................... 9
Plan Vent System ............................................................... 10
Venting Kits ........................................................................ 11
Install Vent System ............................................................ 12
Make Gas Connection ...................................................... 12
Connect Vent ..................................................................... 13
LEVEL DRYER ........................................................................... 13
COMPLETE INSTALLATION CHECKLIST ............................... 13
REVERSE DOOR SWING (OPTIONAL) .................................... 14
TROUBLESHOOTING ............................................................... 21
INSTALLATION NOTES
Date of purchase: _________________________________
Date of installation: _______________________________
Installer: ________________________________________
Model number: ___________________________________
Serial number: ___________________________________
Date d’achat : _____________________________________
Date d’installation : ________________________________
Installateur : ______________________________________
Numéro de modèle : ________________________________
Numéro de série : __________________________________
NOTES CONCERNANT L’INSTALLATION
Table des matières
SÉCURITÉ DE LA SÉCHEUSE ....................................... 22
EXIGENCES D’INSTALLATION ...................................... 24
Outillage et pièces ............................................................ 24
Exigences d’emplacement ............................................... 25
RACCORDEMENT À L’ALIMENTATION ÉLECTRIQUE
DE LA SÉCHEUSE ÉLECTRIQUE – CANADA SEULEMENT ... 27
Spécications électriques ................................................ 27
Installation des pieds de nivellement .............................. 28
RACCORDEMENT D’UNE SÉCHEUSE À GAZ ....................... 28
Spécications de l’alimentation en gaz .......................... 28
Spécications électriques ................................................ 30
L’ÉVACUATION.......................................................................... 30
Exigences concernant l’évacuation ................................ 30
Planication du système d’évacuation ........................... 31
Trousses d’évacuation ...................................................... 32
Installation du circuit d’évacuation ................................. 33
Raccordement au gaz ....................................................... 34
Raccordement du conduit d’évacuation ......................... 34
RÉGLAGE DE L’APLOMB DE LA SÉCHEUSE......................... 35
ACHEVER L’INSTALLATION – LISTE DE VÉRIFICATION ....... 35
INVERSION DU SENS DE L’OUVERTURE DE LA PORTE
(FACULTATIF)
............................................................................. 36
DÉPANNAGE ............................................................................. 44
DRYER INSTALLATION INSTRUCTIONS
29" and 27" Wide Models
Gas (U.S.A. and Canada) & Electric (Canada Only)
INSTRUCTIONS D’INSTALLATION DE LA SÉCHEUSE
Modèles de 29" et de 27" de largeur
À gaz (É.-U. et Canada) et Électrique (Canada uniquement)
Para obtener acceso al manual de uso y cuidado en español, o para obtener información adicional acerca de su producto, visite:
www.whirlpool.com
Tenga listo su número de modelo completo. Puede encontrar el número de modelo y de serie dentro de la cavidad superior de la puerta.
4
Tools and Parts
Gather the required tools and parts before starting installation.
Tools needed for all installations:
Level
Tape measure
Pliers
Parts package is located in dryer drum. Check that all parts
are included.
Parts needed:
Check local codes. Check existing electrical supply and venting.
See “Electrical Requirements” and “Venting Requirements”
before purchasing parts.
Check code requirements. Some codes limit, or do not permit,
installing dryer in garages, closets, mobile homes, or sleeping
quarters. Contact your local building inspector.
Optional Equipment: (Not supplied with dryer)
Refer to your “Use and Care Guide” for information about
accessories available for your dryer.
Parts supplied:
Flat-blade screwdriver
#2 Phillips screwdriver
Adjustable wrench that
opens to 1" (25 mm) or
hex-head socket wrench
Tin snips (new vent
installations)
Caulking gun and
compound (for installing
new exhaust vent)
Vent clamps
1/4" nut driver or socket
wrench (recommended)
Leveling legs (4)
Tools needed for gas installations:
8" or 10" pipe wrench
8" or 10" adjustable wrench
(for gas connections)
Pipe-joint compound
resistant to LP gas
Utility knife
Location Requirements
You will need:
A location allowing for proper exhaust installation.
See “Venting Requirements.”
INSTALLATION REQUIREMENTS
Putty knife
5
Installation Spacing
A
B
C
18"*
(457 mm)
1"
(25 mm)
29"
(737 mm)
1"
(25 mm)
1"*
(25 mm)
14" max.*
(356 mm)
27¾"
(705 mm)
48 in.
(310 cm )
2
*
2
3"*
(76 mm)
3"*
(76 mm)
24 in.
(155 cm )
2
*
2
A. Recessed area
B. Side view – closet or conned area
C. Closet door with vents
*Required spacing
29" Wide Models
Dryer Dimensions
A. Wide opening side-swing door
B. Wide opening hamper door
A B
Installation clearances:
The location must be large enough to allow the dryer door to
open fully.
Most installations require a minimum 5½" (140 mm) clearance
behind the dryer for the exhaust vent with elbow. See “Venting
Requirements.”
A separate 30 amp circuit for electric dryers.
A separate 15 or 20 amp circuit for gas dryers.
If you are using power supply cord, a grounded electrical
outlet located within 2 ft. (610 mm) of either side of dryer.
See “Electrical Requirements.”
A sturdy oor to support dryer and a total weight (dryer
and load) of 200 lbs. (90.7 kg). The combined weight of a
companion appliance should also be considered.
Level oor with maximum slope of 1" (25 mm) under entire
dryer. If slope is greater than 1" (25 mm), install Extended
Dryer Feet Kit, Part Number 279810. If not level, clothes
may not tumble properly and automatic sensor cycles may
not operate correctly.
Do not operate your dryer at temperatures below 45°F (7°C).
At lower temperatures, the dryer might not shut off at the end
of an automatic cycle. Drying times can be extended.
The dryer must not be installed or stored in an area where it will
be exposed to water and/or weather.
Check code requirements. Some codes limit, or do not permit,
installation of the dryer in garages, closets, mobile homes, or
sleeping quarters. Contact your local building inspector.
NOTE: No other fuel-burning appliance can be installed in the
same closet as a dryer.
Mobile home – Additional installation requirements
This dryer is suitable for mobile home installations. The
installation must conform to the Manufactured Home
Construction and Safety Standard, Title 24 CFR, Part 3280
(formerly the Federal Standard for Mobile Home Construction
and Safety, Title 24, HUD Part 280) or the Canadian
Manufactured Home Standard CAN/CSA-Z240 MH.
Metal exhaust system hardware, available for purchase.
For further information, please reference the “Assistance
or Service” section of the “Use and Care Guide.”
Special provisions must be made in mobile homes to
introduce outside air into the dryer. The opening (such
as a nearby window) should be at least twice as large
as the dryer exhaust opening.
27" Wide Models
Dryer Dimensions
43"
(1092 mm)
27"
(686 mm)
A
23¾"
(603 mm)
43"
(1092 mm)
27"
(686 mm)
*29
1
/
2
"
(749 mm)
13¾"
(349 mm)
B
*29
1
/
2
"
(749 mm)
A. Large opening side-swing door
B. Wide opening hamper door
Installation Spacing
A
B
C
18"*
(457 mm)
1"
(25 mm)
27"
(686 mm)
1"
(25 mm)
1"*
(25 mm)
14" max.*
(356 mm)
29
½
"
(749 mm)
5
½"*
(140 mm)
48 in.
(310 cm )
2
*
2
24 in.
(155 cm )
2
*
2
3"*
(76 mm)
3"*
(76 mm)
A. Recessed area
B. Side view – closet or conned area
C. Closet door with vents
*Required spacing
Installation spacing for recessed area or closet
The dimensions shown are for the minimum spacing allowed.
Additional spacing should be considered for ease of
installation and servicing.
Additional clearances might be required for wall, door, and
oor moldings.
Additional spacing of 1" (25 mm) on all sides of the dryer is
recommended to reduce noise transfer.
For closet installation, with a door, minimum ventilation
openings in the top and bottom of the door are required.
Louvered doors with equivalent ventilation openings are
acceptable.
Companion appliance spacing should also be considered.
6
Install Leveling Legs
Prepare dryer for leveling legs
1.
To avoid damaging oor, use a large at piece of cardboard
from dryer carton; place under entire back edge of dryer.
Firmly grasp dryer body (not console panel) and gently lay
dryer down on cardboard.
GROUNDING INSTRUCTIONS
SAVE THESE INSTRUCTIONS
For a grounded, cord-connected dryer:
This dryer must be grounded. In the event of malfunction or
breakdown, grounding will reduce the risk of electric shock
by providing a path of least resistance for electric current.
This dryer is equipped with a cord having an equipment-
grounding conductor and a grounding plug. The plug must
be plugged into an appropriate outlet that is properly
installed and grounded in accordance with all local codes
and ordinances.
WARNING:
Improper connection of the equipment-
grounding conductor can result in a risk of electric shock.
Check with a qualied electrician or service representative
or personnel if you are in doubt as to whether the dryer is
properly grounded. Do not modify the plug provided with
the dryer: if it will not t the outlet, have a proper outlet
installed by a qualied electrician.
ELECTRIC DRYER POWER
HOOKUP – CANADA ONLY
Electrical Requirements
It is your responsibility:
To contact a qualied electrical installer.
To be sure that the electrical connection is adequate
and in conformance with the Canadian Electrical Code,
C22.1-latest edition and all local codes. A copy of the
above codes standard may be obtained from: Canadian
Standards Association, 178 Rexdale Blvd., Toronto, ON
M9W 1R3 CANADA.
To supply the required 4 wire, single phase, 120/240 volt,
60 Hz., AC only electrical supply on a separate 30-amp
circuit, fused on both sides of the line. A time-delay fuse or
circuit breaker is recommended. Connect to an individual
branch circuit.
This dryer is equipped with a CSA International Certied
Power Cord intended to be plugged into a standard 14-30R
wall receptacle. The cord is 5 ft. (1.52 m) in length. Be sure
wall receptacle is within reach of dryer’s nal location.
4-wire receptacle (14-30R)
Do not use an extension cord.
If using a replacement power supply cord, it is recommended
that you use Power Supply Cord Replacement Part Number
8579325. For further information, please reference the
“Assistance or Service” section of the “Use and Care Guide.”
7
Screw in leveling legs
2.
Examine leveling legs and nd diamond marking. Screw legs
into leg holes by hand. Use a wrench to nish turning legs
until diamond marking is no longer visible.
Now stand the dryer on its feet. Slide the dryer until it is
close to its nal location. Leave enough room to connect the
exhaust vent.
For mobile home use
Gas dryers must be securely fastened to the oor.
Mobile home installations require a Mobile Home Installation
Hold-down Kit. For ordering information, please reference the
“Use and Care Guide.”
diamond
marking
GAS DRYER POWER HOOKUP
Gas Supply Requirements
Gas type
Natural gas:
This dryer is equipped for use with Natural Gas. It is design-
certied by CSA International for LP (propane or butane) gases
with appropriate conversion.
Your dryer must have the correct burner for the type of gas
in your home. Burner information is located on the rating
plate in the door well of your dryer. If this information does
not agree with the type of gas available, please reference the
“Assistance or Service” section of the “Use and Care Guide.”
LP gas conversion:
Conversion must be made by a qualied technician.
No attempt shall be made to convert the dryer from the gas
specied on the model/serial rating plate for use with a different
gas without consulting the serving gas supplier.
IMPORTANT: The gas installation must conform with local codes,
or in the absence of local codes, with the National Fuel Gas
Code, ANSI Z223.1/NFPA 54 or the Canadian Natural Gas and
Propane Installation Code, CSA B149.1.
8
Gas supply line
1/2" NPT pipe is recommended.
3/8" approved tubing is acceptable for lengths under
20 ft. (6.1 m) if local codes and gas supplier permit.
Must include 1/8" NPT minimum plugged tapping accessible
for test gauge connection, immediately upstream of the gas
connection to the dryer (see illustration).
Must include a shut-off valve:
In the U.S.A.:
An individual manual shut-off valve must be installed within
six (6) feet (1.8 m) of the dryer in accordance with the
National Fuel Gas Code, ANSI Z223.1.
In Canada:
An individual manual shut-off valve must be installed in
accordance with the B149.1, Natural Gas and Propane
Installation Code. It is recommended that an individual
manual shut-off valve be installed within six (6) feet (1.8 m)
of the dryer.
The shut-off valve location should be easy to reach for opening
and closing.
A
B
E
D
C
A. 3/8" exible gas connector
B. 3/8" pipe to are adapter tting
C. 1/8" NPT minimum plugged tapping
D. 1/2" NPT gas supply line
E. Gas shut-off valve
Gas supply connection requirements
There are many methods by which your gas dryer can be
connected to the gas supply. Listed here are some guidelines
for two different methods of connection.
This dryer must be connected to the gas supply line with
a listed exible gas connector that complies with the standard
for connectors for gas appliances, ANSI Z21.24 or CSA 6.10.
Option 1 (Recommended Method)
Flexible stainless steel gas connector:
If local codes permit, use a new exible stainless steel gas
connector (Design Certied by the American Gas Association
or CSA International) to connect your dryer to the rigid gas
supply line. Use an elbow and a 3/8" are x 3/8" NPT adapter
tting between the stainless steel gas connector and the
dryer gas pipe, as needed to prevent kinking.
Option 2 (Alternate Method)
Approved aluminum or copper tubing:
Lengths over 20 ft. (6.1 m) can use 3/8" approved tubing
(if codes and gas supplier permit).
If you are using Natural Gas, do not use copper tubing.
3/8" are x 3/8" NPT adapter tting between dryer pipe
and 3/8" approved tubing.
Lengths over 20 ft. (6.1 m) should use larger tubing and
a different size adapter tting.
If your dryer has been converted to use LP gas, 3/8" LP
compatible copper tubing can be used. If the total length
of the supply line is more than 20 ft. (6.1 m), use larger pipe.
NOTE: Pipe joint compounds that resist the action of LP
gas must be used. Do not use TEFLON
®†
tape.
Dryer gas pipe
The gas pipe that comes out through the rear of your dryer
has a 3/8" male pipe thread.
29" Wide Model
A
1¼"
(32 mm)
9¼"
(235 mm)
A. 3/8" NPT dryer pipe
27" Wide Model
A
A. 3/8" NPT dryer pipe
*5
3
/4"
(146 mm)
1
1
/2"
(38 mm)
A. 3/8" NPT dryer pipe
Burner input requirements
Elevations up to 10,000 ft. (3,048 m):
The design of this dryer is certied by CSA International for
use at altitudes up to 10,000 ft. (3,048 m) above sea level at
the B.T.U. rating indicated on the model/serial number plate.
Burner input adjustments are not required when the dryer is
operated up to this elevation.
Elevations above 10,000 ft. (3,048 m):
When installed above 10,000 ft. (3,048 m), a 4% reduction
of the burner B.T.U. rating shown on the model/serial
number plate is required for each 1,000 ft. (305 m)
increase in elevation.
Gas supply pressure testing
The dryer must be disconnected from the gas supply piping
system during pressure testing at pressures greater than
1/2 psi.
†®TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company.
9
Electrical Requirements
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
re, or electrical shock.
WARNING
120 Volt, 60 Hz., AC only, 15- or 20-amp fused electrical
supply is required. A time-delay fuse or circuit breaker is
recommended. It is also recommended that a separate
circuit serving only this dryer be provided.
GROUNDING INSTRUCTIONS
SAVE THESE INSTRUCTIONS
For a grounded, cord-connected dryer:
This dryer must be grounded. In the event of malfunction or
breakdown, grounding will reduce the risk of electric shock
by providing a path of least resistance for electric current.
This dryer is equipped with a cord having an equipment-
grounding conductor and a grounding plug. The plug must
be plugged into an appropriate outlet that is properly
installed and grounded in accordance with all local codes
and ordinances.
WARNING: Improper connection of the equipment-
grounding conductor can result in a risk of electric shock.
Check with a qualied electrician or service representative
or personnel if you are in doubt as to whether the dryer is
properly grounded. Do not modify the plug provided with
the dryer: if it will not t the outlet, have a proper outlet
installed by a qualied electrician.
VENTING
Venting Requirements
WARNING: To reduce the risk of re, this dryer MUST BE
EXHAUSTED OUTDOORS.
IMPORTANT: Observe all governing codes and ordinances.
Dryer exhaust must not be connected into any gas vent,
chimney, wall, ceiling, attic, crawlspace, or a concealed space
of a building. Only rigid or exible metal vent shall be used for
exhausting.
Only a 4" (102 mm) heavy metal exhaust vent and clamps
may be used.
Do not use plastic or metal foil vent.
Rigid metal vent:
Recommended for best drying performance and to avoid
crushing and kinking.
Flexible metal vent: (Acceptable only if accessible to clean)
Must be fully extended and supported in nal dryer location.
Remove excess to avoid sagging and kinking that may result
in reduced airow and poor performance.
Do not install in enclosed walls, ceilings, or oors.
The total length should not exceed 7
3
/
4
ft. (2.4 m).
NOTE: If using an existing vent system, clean lint from entire
length of the system and make sure exhaust hood is not
plugged with lint. Replace plastic or metal foil vents with rigid
metal or exible metal vents. Review “Vent System Chart” and,
if necessary, modify existing vent system to achieve best drying
performance.
4"
(102 mm)
4" (102 mm) heavy metal exhaust vent
10
Exhaust hoods:
Must be at least 12" (305 mm) from ground or any object
that may obstruct exhaust (such as owers, rocks, bushes,
or snow).
Elbows:
45° elbows provide better airow than 90° elbows.
Clamps:
Use clamps to seal all joints.
Exhaust vent must not be connected or secured with screws
or other fastening devices that extend into interior of duct
and catch lint. Do not use duct tape.
See “Venting Kits” for more information.
Plan Vent System
Recommended exhaust installations
Typical installations vent the dryer from the rear of the dryer.
Other installations are possible.
B
B
C
D
E
F
G
H
I
A
A. Dryer
B. Elbow
C. Wall
D. Exhaust hood
E. Clamps
F. Rigid metal or exible metal vent
G. Vent length necessary to connect elbows
H. Exhaust outlet
I. Optional side exhaust outlet
Optional exhaust installations:
27" Wide Models can be converted to exhaust out the right side,
left side, or through the bottom (4-way vent kit). Each kit includes
step-by-step instructions. For ordering information, see “Venting
Kits.”
A. Standard rear offset exhaust installation
B. Left- or right-side exhaust installation
(27" wide models only)
C. Bottom exhaust installation (27" wide models only)
A B C
Recommended Styles:
Acceptable Style:
Louvered hood Box hood
Angled hood
Good
Better
11
Alternate installations for close clearances
Venting systems come in many varieties. Select the type best
for your installation. Two close-clearance installations are shown.
Refer to the manufacturer’s instructions.
Over-The-Top installation (also available with one offset elbow)
Periscope installation
NOTE: The following kits for close clearance alternate
installations are available for purchase.
Venting Kits
For more information, call 1-800-901-2042, or visit us
at www.applianceaccessories.com. In Canada, call
1-800-807-6777 or visit us at www.whirlpoolparts.ca.
Part Number Descriptions
8171587RP 0–5" Metal vent periscope
4396037RP 0"–18" Metal vent periscope
4396011RP 18"–29" Metal vent periscope
4396014 29"–50" Metal vent periscope
4392892 In-Wall metal DuraVent™ Periscope
W10186596 4-way vent kit – universal grey (27" Dryers Only)
4396028 Sure Connect™ venting kit
(over-the-top installation)
4396009RP 5' Universal connect vent, exible dryer venting
4396010RP 6' SecureConnect™ vent, exible dryer venting
4396013RB Dryer vent installer’s kit
4396033RP 5' exible dryer venting with clamps
4396727RP 8' exible dryer venting with clamps
4396004 Dryer offset elbow
4396005 Wall offset elbow
4396006RW DuraSafe™ close elbow
4396007RW Through-the-wall vent cap
4396008RP 4" steel dryer venting clamps – 2 pack
8212662 Flush mounting louvered vent hood 4"
Special provisions for mobile home installations:
The exhaust vent must be securely fastened to a noncombustible
portion of the mobile home structure and must not terminate
beneath the mobile home. Terminate the exhaust vent outside.
Determine vent path:
Select route that will provide straightest and most direct path
outdoors.
Plan installation to use fewest number of elbows and turns.
When using elbows or making turns, allow as much room
as possible.
Bend vent gradually to avoid kinking.
Use as few 90° turns as possible.
Determine vent length and elbows needed for best
drying performance:
Use following “Vent System Chart” to determine type of vent
material and hood combinations acceptable to use.
NOTE: Do not use vent runs longer than those specied
in “Vent System Chart.” Exhaust systems longer than those
specied will:
Shorten life of dryer.
Reduce performance, resulting in longer drying times and
increased energy usage.
Vent System Chart
Number of
90° turns or
elbows
Type
of vent
Box/louvered
hoods
Angled
hoods
1
4
3
2
0
Rigid metal
Rigid metal
Rigid metal
Rigid metal
Rigid metal
64 ft. (20 m)
54 ft. (16.5 m)
44 ft. (13.4 m)
35 ft. (10.7 m)
27 ft. (8.2 m)
58 ft. (17.7 m)
48 ft. (14.6 m)
38 ft. (11.6 m)
29 ft. (8.8 m)
21 ft. (6.4 m)
The “Vent System Chart” provides venting requirements that
will help achieve best drying performance.
NOTE: Side and bottom exhaust installations for 27" wide
models have a 90º turn inside the dryer. To determine
maximum exhaust length, add one 90º turn to the chart.
12
Install Vent System
12" min.
(305 mm)
12" min.
(305 mm)
Install exhaust hood
1.
Install exhaust hood and use caulking compound to seal
exterior wall opening around exhaust hood.
A
B
C
D
Plan pipe tting connection
2.
A combination of pipe ttings must be used to connect dryer
to existing gas line. A recommended connection is shown.
Your connection may be different, according to supply line
type, size, and location.
A. 3/8" exible gas connector
B. 3/8" dryer pipe
C. 3/8" to 3/8" pipe elbow
D. 3/8" pipe-to-are adapter tting
Open shut-off valve in supply line; valve is open when handle
is parallel to gas pipe. Then, test all connections by brushing
on an approved noncorrosive leak-detection solution.
Bubbles will show a leak. Correct any leaks found.
†®TEFLON is a registered trademark of E.I. Dupont De Nemours and Company.
Connect vent to exhaust hood
2.
Vent must t over the exhaust hood. Secure vent to exhaust
hood with 4" (102 mm) clamp. Run vent to dryer location
using straightest path possible. Avoid 90° turns. Use clamps
to seal all joints. Do not use duct tape, screws, or other
fastening devices that extend into interior of vent to secure
vent, because they can catch lint.
A
B
Connect gas supply to dryer
1.
Remove red cap from gas pipe. Using a wrench to tighten,
connect gas supply to dryer. Use pipe-joint compound
on threads of all non-ared male ttings. If exible metal
tubing is used, be sure there are no kinks.
NOTE: For LP gas connections, you must use pipe-joint
compound resistant to action of LP gas. Do not use
TEFLON
®†
tape.
Make Gas Connection
Vent System Chart
(29" Wide Long Vent Models Only)
Number of
90° turns
or elbows
Type
of vent
Box/louvered, or
Angled hoods
1
4
3
2
0
Rigid metal
120 ft. (36.6 m)
110 ft. (33.5 m)
100 ft. (30.5 m)
90 ft. (27.4 m)
80 ft. (24.4 m)
Rigid metal
Rigid metal
Rigid metal
Rigid metal
5 70 ft. (21.3 m)Rigid metal
Open shut-off valve
3.
A
B
Closed valve
Open valve
Non-ared
male tting
Flared
male tting
13
Connect Vent
Connect vent to exhaust outlet
1.
Move dryer to nal location
2.
Using a 4" (102 mm) clamp, connect vent to exhaust outlet
in dryer. If connecting to existing vent, make sure vent is
clean. Dryer vent must t over dryer exhaust outlet and inside
exhaust hood. Check that vent is secured to exhaust hood
with a 4" (102 mm) clamp.
Move dryer to nal location. Avoid crushing or kinking vent.
After dryer is in place, remove corner posts and cardboard
from under the dryer.
Level Dryer
Level dryer
1.
Not Level LEVEL Not Level
Check levelness of dryer from side to side. Repeat from
front to back.
NOTE: The dryer must be level for the moisture sensing system
to operate correctly.
Tighten and adjust leveling legs
2.
If dryer is not level, prop up using a wood block. Use wrench
to adjust legs up or down, and check again for levelness.
Once legs are level, make sure all four legs are snug against
the oor before tightening them.
Complete Installation Checklist
q
Check that all parts are now installed. If there is an extra
part, go back through steps to see what was skipped.
q
Check that you have all of your tools.
q
Dispose of/recycle all packaging materials.
q
Check dryer’s nal location. Be sure vent is not crushed
or kinked.
q
Check that dryer is level. See “Level Dryer.”
q
Remove lm on console and any tape remaining on dryer.
q
Wipe dryer drum interior thoroughly with a damp cloth to
remove any dust.
q
Read “Dryer Use” in your “Use and Care Guide.”
q
Set the dryer on a full heat cycle (not an air cycle) for
20 minutes and start the dryer.
If the dryer will not start, check the following:
Dryer is plugged into a grounded 3-prong outlet.
Electrical supply is connected.
Household fuse is intact and tight, or circuit breaker
has not tripped.
Dryer door is closed.
q
When the dryer has been running for 5 minutes, open the
dryer door and feel for heat. If you feel heat, cancel cycle
and close the door.
If you do not feel heat, turn the dryer off and check to see
whether gas supply line shut-off valve is open.
If the gas supply line shut-off valve is closed, open it,
then repeat the 5-minute test as outlined above.
If the gas supply line shut-off valve is open, contact a
qualied technician.
NOTE: You may notice an odor when the dryer is rst heated.
This odor is common when the heating element is rst used.
The odor will go away.
14
Reverse Door Swing (Optional)
If your door is the 29" Super Wide Side-Swing Door,
go to steps 1–13 beginning on this page.
If your door is the 27" Wide Side-Swing Door, go to steps 1–11
beginning on page 16.
If your door is the 27" Wide Side-Swing Door with Glass, go to
steps 1–13 beginning on page 19.
NOTE: Magnetized screwdriver is helpful.
29" Super Wide Side-Swing Door
Place towel on top of dryer to avoid damaging the surface.
Place towel on dryer
1.
Remove bottom screws
2.
Open dryer door. Remove bottom screws from dryer cabinet
side of hinges. Loosen (do not remove) top screws from dryer
cabinet side of hinges.
Lift door until top screws in dryer cabinet are in large part of
hinge slot. Pull door forward off screws. Set door (handle side
up) on top of dryer. Remove top screws from dryer cabinet.
Lift door off top screws
3.
Remove screws from hinges
4.
Remove screws attaching hinges to door.
15
Remove screws at top, bottom, and side of door (4 screws)
that hold the inner and outer door together. Holding door over
towel on dryer, grasp sides of outer door and lift to separate it
from inner door. Set outer door aside.
NOTE: Do not pry apart with putty knife or screwdriver.
Do not pull on door seal or plastic door catches.
Remove screws from door
5.
Remove the door catch, bezel, and plug from the inside of
the inner door by squeezing and pulling/pushing them. Place
the door catch, bezel, and plug on the sides opposite from
where they were.
Plug
Catch and bezel
Switch door catch, bezel, & plug
6.
Rotate outer door
7.
Rotate outer door 180º and set it back down on inner door.
Reattach outer door panel to inner door panel so handle is
on the side where hinges were just removed. Insert 4 door
screws.
Flip door over
8.
Flip door over so handle side is down.
Attach door hinges
9.
Reattach door hinges to dryer door so that the larger hole is
at the bottom of the hinge.
16
Close door and check that door strike aligns with door
catch. If it is needed, slide door catch left or right within slot
to adjust alignment.
Check door strike alignment
13.
Insert screws in hinge holes on
dryer cabinet
12.
NOTE: Two people may be needed to reinstall door.
Insert screws into the bottom holes on left side of dryer
cabinet. Tighten screws halfway. Position door so large
end of door hinge slot is over screws. Slide door up so
screws are in bottom of slots. Tighten screws. Insert and
tighten top screws in hinges.
27" Wide Model Side-Swing Door
Place towel on dryer
1.
Place towel on top of dryer to avoid damaging the surface.
Use a small, at-blade screwdriver to gently remove 4 hinge
hole plugs on left side of dryer cabinet. Transfer plugs into
hinge holes on opposite side of dryer cabinet.
Remove and transfer
hinge hole plugs
11.
Remove door strike and door strike plug from dryer cabinet.
Insert the door strike into door strike plug hole and secure
with screw. Insert door strike plug into original door strike
hole and secure with screw.
10. Remove door strike and
door strike plug
Door strike plugDoor strike
17
Lift door until top screws in dryer cabinet are in large part of
hinge slot. Pull door forward off screws. Set door (handle side
up) on top of dryer. Remove top screws from dryer cabinet.
Lift door off top screws
3.
Remove bottom screws
2.
Open dryer door. Remove bottom screws from dryer cabinet
side of hinges. Loosen (do not remove) top screws from dryer
cabinet side of hinges.
Remove screws attaching hinges to door.
Remove screws from hinges
4.
Rotate outer door
6.
Rotate outer door 180º and set it back down on inner door.
Be certain to keep cardboard spacer centered between doors.
Reattach outer door panel to inner door panel so handle is on
the side where hinges were just removed. Insert 6 door screws.
Remove screws at top, bottom, and side of door (6 screws).
Keep door screws separate from hinge screws as they are
different sizes. Holding door over towel on dryer, grasp sides
of outer door and lift to separate it from inner door.
NOTE: Do not pry apart with putty knife or screwdriver.
Do not pull on door seal or plastic door catches.
Remove screws from door
5.
Flip door over
7.
Flip door over so handle side is down.
18
Check door strike alignment
11.
Close door and check that door strike aligns with door catch.
If it is needed, slide door catch left or right within slot to
adjust alignment.
Insert screws in hinge holes on
dryer cabinet
10.
NOTE: 2 people may be needed to reinstall door.
Insert screws into the bottom holes on left side of dryer cabinet.
Tighten screws halfway. Position door so large end of door hinge
slot is over screws. Slide door up so screws are in bottom of
slots. Tighten screws. Insert and tighten top screws in hinges.
Attach door hinges
8.
Reattach door hinges to dryer door so that the larger hole is
at the bottom of the hinge.
Remove and transfer plugs
9.
Remove the 4 screws that attach 2 plugs on the left side.
Transfer plugs to opposite side using the same 4 screws.
19
27" Wide Model Side-Swing Door with Glass
Place towel on dryer
1.
Place towel on top of dryer to avoid damaging the surface.
Remove bottom screws
2.
Open dryer door. Remove bottom screws from dryer cabinet
side of hinges. Loosen (do not remove) top screws from dryer
cabinet side of hinges.
Lift door until top screws in dryer cabinet are in large part of
hinge slot. Pull door forward off screws. Set door (handle side
up) on top of dryer. Remove top screws from dryer cabinet.
Lift door off top screws
3.
Remove screws attaching hinges to door.
Remove screws from hinges
4.
Flip door over
5.
Flip door over so handle side is down.
20
Rotate outer door
8.
Rotate outer door 180º and set it back down on inner door.
Be certain to keep cardboard spacer centered between
doors. Reattach outer door panel to inner door panel so
handle is on the side where hinges were just removed. Insert
4 door screws.
Remove screws at top, bottom, and side of door (4 screws).
Keep door screws separate from hinge screws as they are
different sizes.
Remove screws from door
6.
Attach door hinges
9.
Reattach door hinges to dryer door so that the larger hole is
at the bottom of the hinge.
Holding door over towel on dryer, pry inner door and lift to
separate it from outer door.
NOTE: Do not pull on door seal or plastic door catches.
Separate inner from outer door
7.
Remove door strike and door strike label from dryer cabinet.
Insert the door strike into hole where door strike label was
removed and secure with screw. Cover original door strike
hole with door strike label and press rmly into place.
Remove door strike and door
strike label
10.
Door strike labelDoor strike
21
Check door strike alignment
13.
Close door and check that door strike aligns with door catch.
If it is needed, slide door catch left or right within slot to
adjust alignment.
Troubleshooting
See the Use and Care Guide or visit our website and
reference “Frequently Asked Questions” to possibly avoid
the cost of a service call.
Insert screws in hinge holes on
dryer cabinet
12.
NOTE: 2 people may be needed to reinstall door.
Insert screws into the bottom holes on left side of dryer
cabinet. Tighten screws halfway. Position door so large end of
door hinge slot is over screws. Slide door up so screws are in
bottom of slots. Tighten screws. Insert and tighten top screws
in hinges.
Remove and transfer plugs
11.
Remove the 4 screws that attach 2 plugs on the left side.
Transfer plugs to opposite side using the same 4 screws.
W10514185A
W10514176A-SP
01/13
Printed in U.S.A.
Imprimé aux É.-U.
®/™ ©2013 Whirlpool. All rights reserved.
Used under license in Canada.
®/™ ©2013 Whirlpool. Tous droits réservés.
Emploi sous licence au Canada.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44

Whirlpool WGD4800XQ Installation guide

Category
Electric laundry dryers
Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI

in other languages