Lightolier IS-SQ6_Grid User manual

Type
User manual

Lightolier IS-SQ6_Grid is a lighting system that can be installed in a T-bar grid. It consists of a fixture, endplate, conduit, and knock-out hole. The fixture can be inserted into the grid and then installed using screws. The endplate is then attached to the fixture and the conduit is connected to the endplate. The knock-out hole is used to pass wires through the endplate.

The Lightolier IS-SQ6_Grid can be used in a variety of applications, including commercial and industrial settings. It is a versatile system that can be used to create a variety of lighting effects. The fixture can be used with a variety of lamps, including incandescent, fluorescent, and LED lamps.

Lightolier IS-SQ6_Grid is a lighting system that can be installed in a T-bar grid. It consists of a fixture, endplate, conduit, and knock-out hole. The fixture can be inserted into the grid and then installed using screws. The endplate is then attached to the fixture and the conduit is connected to the endplate. The knock-out hole is used to pass wires through the endplate.

The Lightolier IS-SQ6_Grid can be used in a variety of applications, including commercial and industrial settings. It is a versatile system that can be used to create a variety of lighting effects. The fixture can be used with a variety of lamps, including incandescent, fluorescent, and LED lamps.

"JSQPSU3PBE'BMM3JWFS."tt'BY
We reserve the right to change details of design, materials and finish.
XXXMJHIUPMJFSDPN½1IJMJQT(SPVQt
Lighting Systems IS-SQ6_Grid
1BHFPG *OTUSVDUJPO4IFFUGPS"TTFNCMZBOE*OTUBMMBUJPOPG42(SJE
#
3&"%"/%6/%&345"/%5)&4&*/4536$5*0/4#&'03&130$&&%*/(
3&5"*/5)&4&*/4536$5*0/4'03."*/5&/"/$&3&'&3&/$&
5IJTmYUVSFJTJOUFOEFEGPSJOTUBMMBUJPOJOBDDPSEBODFXJUIUIF/BUJPOBM&MFDUSJDBM$PEFBOEMPDBMSFHVMBUJPOT
5PBTTVSFGVMMDPNQMJBODFXJUIMPDBMDPEFTBOESFHVMBUJPOTDIFDLXJUIZPVSMPDBMFMFDUSJDBMJOTQFDUPSCFGPSF
JOTUBMMBUJPO5PQSFWFOUFMFDUSJDBMTIPDLUVSOPGGFMFDUSJDJUZBUFMFDUSJDBMQBOFMCFGPSFQSPDFFEJOH
%0/05*/45"--5)*44:45&.*/"8&503%".1-0$"5*0/
%0/05&/&3(*;&"/:5)*/(05)&35)"/5)&'*9563&4*/5)&4:45&.
$0/53"$503*43&410/4*#-&'03"%&26"5&-:3&*/'03$*/($&*-*/(504611035'*9563&8&*()5
4 7/8"
5 3/4"
4 7/8"
5 3/4"
"JSQPSU3PBE'BMM3JWFS."tt'BY
We reserve the right to change details of design, materials and finish.
XXXMJHIUPMJFSDPN½1IJMJQT(SPVQt
Lighting Systems IS-SQ6_Grid
1BHFPG *OTUSVDUJPO4IFFUGPS"TTFNCMZBOE*OTUBMMBUJPOPG42(SJE
#
Inserting the Fixture into the GridStep 1.
-JGUUIFmYUVSFUISPVHIUIFPQFOJOHOFYUUPUIFPQFOJOHUIBUUIFmYUVSFJTUPCFJOTUBMMFE'JHA.
Installing the First Fixture
Step 2.
0ODFUIFmYUVSFJTJOUIFHSJESFNPWFUIFLOPDLPVUPOUIFUPQPGUIFmYUVSFA.
3VOUIFXJSFTUISPVHIUIFLOPDLPVUIPMFBOEBUUBDIUIFDPOEVJUUPUIFmYUVSF'JHB.
.BLFFMFDUSJDBMDPOOFDUJPOTQFS/&$MPDBMDPEFT$
"UUBDIUIFFOEQMBUFUPUIFFOEPGUIFmYUVSFUIBUXJMMOPUCFKPJOFEUPBOPUIFSmYUVSF'JHD.
*OTFSUUIFHSJECSBDLFUTJOUPUIFTMPUTPOUIFJOOFSTJEFPGUIFmYUVSF'JHE.
1VTIUIFHSJECSBDLFUTPJUHPFTBHBJOTUUIFmYUVSFBOEUIFOTDSFXJUUPUIFmYUVSF'JHF.
Figure 1
T-Bar Grid
T-Bar Grid
Fixture
Figure 3
Figure 5
Figure 2
Figure 4
Conduit
Knock Out
Hole
Endplate
Grid Bracket
Tighten Screw
"JSQPSU3PBE'BMM3JWFS."tt'BY
We reserve the right to change details of design, materials and finish.
XXXMJHIUPMJFSDPN½1IJMJQT(SPVQt
Lighting Systems IS-SQ6_Grid
1BHFPG *OTUSVDUJPO4IFFUGPS"TTFNCMZBOE*OTUBMMBUJPOPG42(SJE
#
Endplate
Lamp
Socket
Lamp
Socket
Figure 6
Installing the Remaining Fixtures
Step 3.
*OTFSUUIFSFNBJOJOHmYUVSFTUIFTBNFBTUIFmSTUmYUVSFA.
$POOFDUUIFXJSFTCFUXFFOUIFmYUVSFTB.
0OUIFMBTUmYUVSFJOUIFSVOJOTUBMMUIFSFNBJOJOHFOEQMBUF'JH$
Installing the Lamps
Step 4.
8IFOJOTUBMMJOHMBNQTPOBmYUVSFXJUIFOEQMBUFTPOCPUIFOETJOTFSUUIFMBNQQJOTPOPOFFOEPGUIFMBNQA.
JOUPPOFPGUIFTMPUTPOUIFFOEQMBUF'JH
-JGUUIFPUIFSFOEPGUIFMBNQJOUPUIFmYUVSFB.
1VMMUIFMBNQQJOTPVUPGUIFFOEQMBUFBOEJOTFSUUIFMBNQJOUPUIFTPDLFUT$
'PSmYUVSFTUIBUPOMZIBWFPOFPSOPFOEQMBUFTJOTFSUUIFMBNQJOUPUIFPQFOJOHCFMPXUIFTPDLFUTUIBUHPFTD.
JOUPUIFOFYUmYUVSF5IFOTMJEFJUCBDLJOUPUIFmYUVSFBOEJOTFSUJUJOUPUIFTPDLFUT5IJTJTFBTJFSUIBOVTJOH
the slots in the endplate.
  • Page 1 1
  • Page 2 2
  • Page 3 3

Lightolier IS-SQ6_Grid User manual

Type
User manual

Lightolier IS-SQ6_Grid is a lighting system that can be installed in a T-bar grid. It consists of a fixture, endplate, conduit, and knock-out hole. The fixture can be inserted into the grid and then installed using screws. The endplate is then attached to the fixture and the conduit is connected to the endplate. The knock-out hole is used to pass wires through the endplate.

The Lightolier IS-SQ6_Grid can be used in a variety of applications, including commercial and industrial settings. It is a versatile system that can be used to create a variety of lighting effects. The fixture can be used with a variety of lamps, including incandescent, fluorescent, and LED lamps.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI