Briggs & Stratton 01813-0 Owner's manual

Type
Owner's manual

This manual is also suitable for

Brig, s & Stratton Power Products Automatic Transfer Switch
Installation and Owner's Manual
TABLE OF CONTENTS
TABLE OF CONTENTS ........................... 2
SAFETY RULES .................................. 3
INTRODUCTION ................................ 4
For the Home or Business Owner: .............. 4
For the Installing Dealer/Contractor: ............. 4
Owner Orientation ........................... 4
Installer Responsibilities ........................ 4
Equipment Description ......................... 5
INSTALLATION .................................. 5
Unpacking ................................... 5
Delivery Inspection ........................ 5
Shipment Contents ........................ 5
Mounting Dimensions ...................... 5
Mounting Guidelines ....................... 6
Power Wiring Interconnections ................ 6-7
SYSTEM OPERATION ............................. 8
TESTING THE AUTOMATIC TRANSFERSWITCH .... 8
Automatic Sequence........................... 8
Utility Fail................................ 8
EngineWarm-Up .......................... 8
Transfer ................................. 8
Utility Pickup............................. 8
Retransfer ............................... 8
EngineCool Down ........................ 8
Specifications................................. 8
Model 01813 ............................. 8
Model 01814 ............................. 8
When CallingThe Factory ...................... 8
TROUBLESHOOTING ............................ 9
DIAGRAMS, EXPLODEDVIEWS, PARTSLISTS..... 10-13
NOTES ....................................... 14
WARRANTY ................................... 15
1:7;1_-_:_Je_.'l Bri_s & Stratton Power Products Automatic Transfer Switch
Installation and Owner's Manual
SAFETY RULES
This is the safety alert symbol. It is used to
alert you to potential personal injury
hazards. Obey all safety messages that follow
this symbol to avoid possible injury or death.
The safety alert symbol (_i,) is used with a signal word
(DANGER, CAUTION,WARNING), a pictorial and/or a
safety message to alert you to hazards. DANGER indicates
a hazard which, if not avoided, will result in death or
serious injury. WARNING indicates a hazard which, if not
avoided, could result in death or serious injury.
CAUTION indicates a hazard which, if not avoided, might
result in minor or moderate injury. CAUTION, when
used without the alert symbol, indicates a situation that
could result in equipment damage. Follow safety messages
to avoid or reduce the risk of injury or death.
The manufacturer cannot possibly anticipate every possible
circumstance that might involve a hazard.The warnings in
this manual, and the tags and decals affixed to the unit are,
therefore, not all-inclusive. If you use a procedure, work
method or operating technique that the manufacturer does
not specifically recommend, you must satisfy yourself that it
is safe for you and others.You must also make sure that the
procedure, work method or operating technique that you
choose does not render the transfer switch unsafe.
WARNING
Only qualified electricians should attempt installation
of this system, which must strictly comply with
applicable codes, standards and regulations.
WARN ING
DO NOT touch bare wires or receptacles.
DO NOT use transfer switch with worn, frayed, bare or
otherwise damaged wiring.
DO NOT handle electrical cords while standing in water,
while barefoot, or while hands or feet are wet.
If you must work around a unit while it is operating, stand on
an insulated dry surface to reduce shock hazard.
DO NOT allow unqualified persons or children to operate or
service transfer switch.
In case of an accident caused by electrical shock, immediately
shut down the source of electrical power and contact local
authorities. Avoid direct contact with the victim.
CAUTION
Use transfer switch only for intended uses.
If you have questions about intended use, ask dealer or
contact Briggs and Stratton Power Products.
DO NOT expose transfer switch to excessive moisture, dust,
dirt, or corrosive vapors.
Despite the safe design of the transfer switch, operating this
equipment imprudently, neglecting its maintenance or being
careless can cause possible injury or death.
Remain alert at all times while working on this equipment.
NEVER work on the equipment when you are physically or
mentally fatigued.
If connected devices overheat, turn them off and turn off their
circuit breaker/fuse.
Bri_s & Stratton Power Products Automatic Transfer Switch
Installation and Owner's Manual
INTRODUCTION
Thank you for your purchase of this Briggs & Stratton
Power Products Automatic Transfer Switch.This product is
intended for use with Briggs & Stratton Home Standby
Generator sets ONLY.This is an optional home standby
system which provides an alternate source of electric
power and to serve loads such as heating, refrigeration
systems, and communication systems that, when stopped
during any power outage, could cause discomfort, or the
like.This product DOES NOT qualify for emergency
standby as defined by NFPA 70 (NEC).
Briggs and Stratton Power Products (BSPP) has made every
effort to provide for a safe, streamlined and cost-effective
installation. Each installation is unique, it is impossible to
know of and advise of all conceivable procedures and
methods by which installation might be achieved.We could
not know of possible hazards and/or the results of each
method or procedure. For these reasons,
Only licensed electrical contractors should
install transfer switches. Installations must
strictly comply with all applicable federal,
state and local codes, standards and
regulations.
Your BSPPTransfer Switch is supplied with this combined
"Installation and Owner's Manuar'.This is an important
document and should be retained by the owner after the
installation has been completed.
Every effort has been expended to make sure that the
information in this manual is both accurate and current.
However, the manufacturer reserves the right to change,
alter or otherwise improve the system at any time without
prior notice.
For the Home or Business Owner
To help you make informed choices and communicate
effectively with your installation contractor(s),
Read and understand the
Owner Orientation Section of this manual
BEFORE contracting or starting
your transfer switch installation.
To arrange for proper installation, contact the store at
which you purchased your BSPPTransfer Switch, your
dealer, or your utility power provider.
The Transfer Switch Warranty is VOID
unless the system is installed by a
licensed electrical professional.
For the Installing Dealer/Contractor
Check federal, state and local codes for questions on
installation.
If you need more informationabout the transfer switch,
call 1-800-743-4115,between 8:00AM and 5:00 PM CT.
Owner Orientation
The illustrations are for typical circumstances and are
meant to familiarize you with the installation options
available with your transfer switch.
Local codes, appearance, and distances are the factors that
must be considered when negotiating with an installation
professional.As the distance from the existing electrical
service increases, compensation in wiring materials must be
allowed for.This is necessary to comply with local codes
and overcome electrical voltage drops.
The factors mentioned above will have a direct effect
on the overall price of your transfer switch installation.
NOTE: Your installer must check local codes AND obtain
permits before installing the system.
Read and follow the instructions given in this manual.
Follow a regular schedule in caring for and using your
transfer switch, as specified in the manual.
Installer Responsibilities
Read and observe the safety rules.
Read and follow the instructions given in this manual.
Check federal, state and local codes.
[_ ] Briggs&StrattonPowerProductsAutomaticTransferSwitch
Installation and Owner's Manual
Equipment Description
These switches are a new generation of transfer switches
that are intended to transfer the entire load of normal
residential installations.The load is connected either to
utility power (normal) or home standby power
(emergency).The transfer switch monitors utility and
generator voltages and will automatically connect to the
appropriate source of power.
Major components of the transfer switch are a 2 pole
double throw transfer switch, control circuit board, fused
utility terminals and interconnecting wiring.
The transfer switch is solenoid-operated from utility or
generator inputs and contain suitable mechanical and
electrical interlock switches to eliminate the possibility of
connecting the utility service to the generator output. It
has ratings capable of switching full utility power into the
residence. In addition, a manual override lever is provided
for the transfer function.
The control circuit board has active circuits sensing utility
and generator voltages. It creates a signal for the generator
start-up, switch transfer, retransfer when utility is restored
and generator cool down periods.The control board also
contains red and green LED's indicating the power sources
available and two relay operated contacts that provide
supervisory control of external loads.
INSTALLATION
Unpacking
Delivery Inspection
After removing the carton, carefully inspect the transfer
switch components for any damage that may have occurred
during shipment.
IMPORTANT: If loss or damage is noted at time of
delivery, have the person(s) making delivery note all damage
on the freight bill and affix his signature under the
consignor's memo of loss or damage. If loss or damage is
noted after delivery, contact the carrier for claim
procedures. Missing or damaged parts are not warranted.
Shipment Contents
Automatic Power Transfer Switch
Installation and Owner's Manual
Mounting Dimensions
Figure I depicts the physical size and mounting hole
locations of the NEMA 3R automatic transfer switch
enclosure.This enclosure is suitable for indoor/outdoor use.
L
Enclosure Dimensions Mounting Dimensions
Model 01813
16'
Enclosure Dimensions
<-----_ 1,.----------_11.
@ @
@ @
Mounting Dimensions
Model 01814
The transfer switch enclosure is commonly secured
through the predrilled holes, as shown.
06"
Bri_s & Stratton Power Products Automatic Transfer Switch
Installation and Owner's Manual
Mounting Guidelines
The Automatic Transfer Switch isenclosed in a N EMA Type
3R enclosure suitable for indoor/outdoor use. Guidelines for
mounting the Automatic Transfer Switch include:
Install the switch on a firm, sturdy supporting structure.
The switch must be installed with minimum NEMA 3R
hardware for conduit connections.
To prevent switch contact distortion, level and plumb the
enclosure.This can be done by placing washers between
the switch enclosure and the mounting surface.
NEVER install the switch where any corrosive substance
might drip onto the enclosure.
Protect the switch at all times against excessive moisture,
dust, dirt, lint, construction grit and corrosive vapors.
A typical installation of the Automatic Power Transfer
Switch is depicted in Figure 2. It is best if it is mounted
near the utility meter, either inside or outside. Discuss
layout suggestions/changes with the owner before beginning
the system installation process.
Power Wiring Interconnections
All wiring must be the proper size, properly supported and
protected by conduit.
Complete the following connections between the transfer
switch, main distribution panel, utility power and generator
(Figure 3, on next page).
I. Ensure utility power is turned OFF. Connect utility
power supply leads to transfer switch terminals
marked "UTILITY CONNECTION".
2. Connect utility neutral to the transfer switch
"NEUTRAL" terminal.
.
4.
5.
.
7.
8.
9.
CAUTION
Failureto follow above warning could causedamageand/or
malfunction of equipment.
Connect main distribution panel power leads to transfer
switch terminals marked "LOAD CONNECTION".
Connect main distribution panel neutral lead to
transfer switch "NEUTRAL" terminal.
Connect generator power supply leads from the
generator's control panel to transfer switch terminals
marked "GENERATOR CONNECTION".
Connect generator Neutral from the control panel to
the transfer switch "NEUTRAL" terminal.
Connect generator"GND" from the control panel to
the transfer switch "GND" terminal.
Connect main distribution panel "GND" to the
transfer switch "GND" terminal.
Connect generator utility 240VAC terminals to
transfer switch utility 240VAC terminals.
10. Terminal strip on control module in transfer switch has
four connections for customer use.There are two sets
of"Normally Closed" contacts available.They will be
activated when generator power is required.These can
be used for supervisory control of large connected
loads on generator, for example, disconnecting air
conditioner, water heater, etc. or an alarm source.
I I. Tighten all wire connections/fasteners to proper torque.
Li_,'__-_li'A._mliitm';t_laS,'_?LPt_l_IL_'_ft'_'qr_...1
r--
r-
r----'---
r'-"--
r-"---
/
Main
Breaker
Panel
/
Transfer Switch
/
/
t Generator
1_ I Brig, s & Stratton Power Products Automatic Transfer Switch
Installation and Owner's Manual
Utility
Connection
Generator
Connection
Ground Lug
Utility
Connection
Generator
Connection
Ground Lug
To Generator
To Utility Power
©
o
Normally
Closed
J Contacts
Load
Connection
Neutral
Terminal
Neutral
Bus _-
Main Distribution Panel
I Main I
MODEL 0 1813
[
To Utility Power
oi I
TO Generator
_ Normally
° _llj 2°Se_SLoad
_ / Connection
_. Neutral
_ Terminal
Main Distribution Panel
II IMainl
Neutral
°l J
MODEL 0 1814
WERFRODUCTS
Brig, s & Stratton Power Products Automatic Transfer Switch
Installation and Owner's Manual
SYSTEM OPERATION
To select automatic transfer operation, do the following:
I. Set service disconnect switch that sends utility power
to transfer switch to "On" position.
2. Set generator's main circuit breaker to its "On"
position.
3. Install 15Amp fuse in control panel on generator.
4. Set AUTO/OFF/MANUAL switch on generator to
"AUTO" position.
The system will now be in automatic operation mode.
TESTING THE
AUTOMATIC TRANSFER
SWITCH
Turn the service disconnect feeding the transfer switch, to
the "Off" position.The automatic sequence will follow.To
go back to utility power, turn the service disconnect to the
"On" position.
Automatic Sequence
Utility Fail
Utility voltage sensor senseswhen utility voltage isbelow
70 percent of nominal. Enginestart sequence isinitiated
after 6 second time delay.
Engine Warm-Up
Time delay to allow for engine warm-up before transfer
fixed at 20 seconds or 50 seconds with optional cold
weather package.
Transfer
Transfers from utility to standby supply occurs after
standby voltage isabove set levels. Minimum engine run
time is 4 minutes after transfer.
Utility Pickup
Voltagepickup level is80 percent of nominal voltage.
Retransfer
Retransfer from standby to utility supply 10 seconds after
utility voltage supply is above pickup level.
Engine Cool Down
Engine will run for 60 seconds after retransfer.
Specifications
UL® 1008 Listed Transfer Switch
Model 01813
Maximum Load/Circuit:
from Load Center .......... 100Amps
RatedAC Voltage ............. 250 Volts
Poles ...................... 2
Frequency .................. 50/60 Hz
Fault Current Rating .......... 22,000 RMS Symmetrical
Amperes
Supervisory Contacts Rating ... 5Amp, 125Volt AC
Weight ..................... 21 Ibs.
Model 01814
Maximum Load/Circuit:
from Load Center .......... 200 Amps
RatedAC Voltage ............. 250 Volts
Poles ...................... 2
Frequency .................. 50/60 Hz
Fault Current Rating .......... 25,000 RMS Symmetrical
Amperes
Supervisory Contacts Rating ... 5Amp, 125Volt AC
Weight ..................... 34 Ibs.
When Calling the Factory
Before contacting Briggs and Stratton Power Products
regarding service or repair of this transfer switch, obtain
the Model Number and Serial Number from the unit data
decal located on or inside the case.
To contact Briggsand Stratton Power Products call
1-800-743-4115,between 8:00AM and 5:00 PM CT.
Briggs & Stratton Power Products Automatic Transfer Switch
Installation and Owner's Manual
TROUBLESHOOTING
Problem Cause Correction
Automatic transfer switch does I. Generator breaker open. I. Reset generator circuit breaker.
not transfer to generator 2. Generator voltage not acceptable. 2. Refer to generator manual.
I. Service disconnect breaker open. I. Reset service disconnect breaker.
Automatic transfer switch does
2. Utility voltage not acceptable. 2. Wait for utility voltage to return
not transfer to utility to normal.
Generator is still running after Engine cool down period. Engine should stop after I minute.
switch transfers to utility power
NC contacts not operating correctly.
Supervised loads (air conditioner,
etc.) are not operating when
utility is present
Check NC contact for proper
operation and/or check control wiring
to external load.
Brig,s&StrattonPowerProductsAutomaticTransferSwitch
Installation and Owner's Manual
TRANSFER SWITCH SCHEMATIC
WI RE SCHEMAT I C
N1 o
UTILITY SUPPLY
240VAC
N2 o
TD GENERATDR
UTILITY
240 VAC
600VAC
2 AMP
FUSE N2
I
TRANSFER SWITCH
I I
55GI i I '
I 1 i
NI
0 I
ml
I
I
I
I
127i I I
i]?? i
i
J3 J2 J1 J4 J6 J5 I
I
CI]N'rRI]L ttl]ARII
N, 12. C[]tTACTS
SUPERV IS[]RY
CI]NTRI]L
128
J
1
I
I
I
I
I
I
1
I
I
I
I
I
I
I
El--
E1
o T1
MAIN DISTRIBUTII]N
PANEL
o T2
E2
oE1
6ENERATI]R SUPPLY
240 VAC
oE2
10
Brig,s & Stratton Power Products Automatic Transfer Switch
Installation and Owner's Manual
TRANSFER SWITCH WIRING DIAGRAM
I RE D I A_RAH
TRANSFER
SWITCH
E
205
128
\
\
_'-- El
206
CONTROL SOARD
O UTILITY O
0
0
ZE
o o
UTILITY
240 VAC
NC1
NC1
NC2
NO2
FUSE
HBLDER
II
Briggs&StrattonPowerProductsAutomaticTransferSwitch
Installation and Owner's Manual
I
2J_
_P3
TRANSFER SWITCH EXPLODEDVIEW & PARTS LIST
MODEL 01813
\
\
\
Item
I
2
3
4
5
6
7
8
9
10
II
12
13
14
15
16
23
24-
Part #
192154GS
192155GS
191995GS
36701GS
36903GS
36905GS
36933GS
193159GS
191668GS
192701GS
B4856GS
22097GS
22473GS
22127GS
190841GS
B4857GS
_29
Description
ENCLOSURE
BACK PANEL
TRANSFER SWITCH. 100A, with
Cover & Handle
SCREW
SCREW
SCREW
SCREW
DECAL, Reinstall After
CONTROL, Board
SPACER, Nylon
LUG, Ground
WASHER, Lock
WASHER
NUT
TERMINAL, Neutral
FUSE
2
'\
\
\
\
\
\
\
\
\
3
Item Part #
17 192151GS
18 192557GS
19 190850GS
20 192702GS
21 B5106GS
22 B5107GS
23 92688GS
24 92690GS
25 90992GS
26 90984GS
27 B4986GS
28 92597GS
29 92165GS
30 93307GS
31 23897GS
32 23762GS
33 36901GS
>
Description
HOLDER, Fuse
STANDOFF, Purse Lock
DECAL, ATS, BSPP
DECAL, Term Strip
DECAL, Connection, Utility
DECAL, Connection, Generator
DECAL, 100A, ATS
DECAL, UL Listed, 100A, ATS
DECAL, Warning Shock
DECAL, Fuse
DECAL, Ground
DECAL, Utility, 240V AC
DECAL, APPVD CB
DECAL, Load
WASHER
WASHER
SCREW
12
I
2J_
_P3
Briggs&StrattonPowerProductsAutomaticTransferSwitch
Installation and Owner's Manual
TRANSFER SWITCH EXPLODEDVIEW & PARTS LIST
MODEL 01814
\
\
\
Item
I
2
3
4
5
6
7
8
9
10
II
12
13
14
15
16
Part #
192156GS
192170GS
192024GS
36701GS
36903GS
36905GS
36901GS
193159GS
191668GS
192701GS
B4856GS
22097GS
22473GS
22127GS
192696GS
B4857GS
3
\
31\
8
'\
\
\
\
\
30
\
27
_-29
Description
ENCLOSURE
BACK PANEL
TRANSFER SWITCH, 200A, with
Cover & Handle
SCREW
SCREW
SCREW
SCREW
DECAL, Reinstall After
CONTROL, Board
SPACER, Nylon
LUG, Ground
WASHER, Lock
WASHER
NUT
TERMINAL, Neutral
FUSE
Item Part #
17 192151GS
18 192557GS
19 190850GS
20 192702GS
21 B5106GS
22 B5107GS
23 192689GS
24 192691GS
25 190992GS
26 190984GS
27 B4986GS
28 192597GS
29 192166GS
30 193307GS
31 23897GS
32 23762GS
Description
HOLDER, Fuse
STANDOFF, Purse Lock
DECAL, ATS, BSPP
DECAL, Term Strip
DECAL, Connection, Utility
DECAL, Connection, Generator
DECAL, 200A, ATS
DECAL, UL Listed, 200A, ATS
DECAL, Warning Shock
DECAL, Fuse
DECAL, Ground
DECAL, Utility 240V AC
DECAL, APPVD CB
DECAL, Load
WASHER
WASHER
13
Brig,s&StrattonPowerProductsAutomaticTransferSwitch
Installation and Owner's Manual
NOTES
14
Effective January 1, 2003 replaces all undated Warranties and all Warranties dated before January 1, 2003
!!iil
!!iil
Briggs & Stratton Power Products Group, LLC will repair or replace, free of charge, any part(s), of the equipment that is defective in material
or workmanship or both. Transportation charges on parts submitted for repair or replacement under this warranty must be borne by
purchaser. This warranty is effective for the time periods and subject to the conditions stated below. For warranty service, find the nearest
Authorized Service Dealer in our dealer Iocator map at www.briggspowerproducts.com.
THERE IS NO OTHER EXPRESS WARRANTY. IMPLIED WARRANTIES, INCLUDING THOSE OF MERCHANTABILITY AND FITNESS
FOR A PARTICULAR PURPOSE, ARE LIMITED TO ONE YEAR FROM PURCHASE, OR TO THE EXTENT PERMITTED BY LAW ANY
AND ALL IMPLIED WARRANTIES ARE EXCLUDED. LIABILITY FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES ARE EXCLUDED
TO THE EXTENT EXCLUSION IS PERMITTED BY LAW. Some states or countries do not allow limitations on how long an implied warranty
lasts, and some states or countries do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation
and exclusion may not apply to you. This warranty gives you specific legal rights and you may also have other rights which vary from state
to state or country to country.
Consumer Use
Commercial Use
The engine and starting batteries are warranted solely by the manufacturers of those products.
2 years for all consumer products in the European Union. Parts only on 2nd year for consumer use of Portable Generator and
Home Generator System - Less than 10 KW, outside of European Union.
The warranty period begins on the date of purchase by the first retail consumer or commercial end user, and continues for the period of time
stated in the table above. "Consumer use" means personal residential household use by a retail consumer. "Commercial use" means all other
uses, including use for commercial, income producing or rental purposes. Once equipment has experienced commercial use, itshall thereafter
be considered as commercial use for purposes of this warranty. Equipment used for Prime Power in place of utility are not applicable to
this warranty. Electric Powered Pressure Washers used for commercial purposes are not warranted.
NO WARRANTY REGISTRATION IS NECESSARY TO OBTAIN WARRANTY ON BRIGGS & STRATTON PRODUCTS. SAVE YOUR
PROOF OF PURCHASE RECEIPT. IF YOU DO NOT PROVIDE PROOF OF THE INITIAL PURCHASE DATE AT THE TIME WARRANTY
SERVICE IS REQUESTED, THE MANUFACTURING DATE OF THE PRODUCT WILL BE USED TO DETERMINE THE WARRANTY
PERIOD.
We welcome warranty repair and apologize to you for being inconvenienced. Any Authorized Service Dealer may perform warranty repairs. Most
warranty repairs are handled routinely, but sometimes requests for warranty service may not be appropriate. For example, warranty service would not
apply if equipment damage occurred because of misuse, lack of routine maintenance, shipping, handling, warehousing or improper installation.
Similarly, the warranty is void if the manufacturing date or the serial number on the equipment has been removed or the equipment has been altered
or modified. During the warranty period, the Authorized Service Dealer, at its option, will repair or replace any part that, upon examination, is found to
be defective under normal use and service. This warranty will not cover the following repairs and equipment:
Normal Wear: Outdoor Power Equipment, like all mechanical devices, needs periodic parts and service to perform well. This warranty does not
cover repair when normal use has exhausted the life of a part or the equipment.
Installation and Maintenance: This warranty does not apply to equipment or parts that have been subjected to improper or unauthorized
installation or alteration and modification, misuse, negligence, accident, overloading, overspeeding, improper maintenance, repair or storage so as,
in our judgment, to adversely affect its performance and reliability. This warranty also does not cover normal maintenance such as adjustments,
fuel system cleaning and obstruction (due to chemical, dirt, carbon, lime, etc.).
Other Exclusions: This warranty excludes wear items such as quick couplers, oil gauges, belts, o-rings, filters, pump packing, etc., pumps that
have been run without water supplied or damage or malfunctions resulting from accidents, abuse, modifications, alterations, or improper servicing
or freezing or chemical deterioration. Accessory parts such as guns, hoses, wands and nozzles are excluded from the product warranty. Also
excluded is used, reconditioned, and demonstration equipment; equipment used for prime power in place of utility power and equipment used in
life support applications.
BRIGGS & STRATTON POWER PRODUCTS GROUP, LLC
JEFFERSON, WI, USA
Commutateur de transfert automaticlue Brig, s & Stratton Power Products
Guide d'installation et d'utilisation
TABLE DES MATIi=RES
TABLE DES MATIERES ................................. 16
REGLES DE SECURITE ................................ 17
INTRODUCTION .................................... 18
Au Propri_taire R_sidentiel ou Commercial ............ 18
Au D_taillant/_ I'Entrepreneur Proc_dant
I'lnstallation .............................. 18
Conseils au Propri_taire ............................ 18
Responsabilit_s de I'lnstallateur ...................... 18
Description de I'Equipement ........................ 19
INSTALLATION ...................................... 19
D_ballage ....................................... 19
V_riflcation de la Livraison ...................... 19
Contenu de la Bo_te ........................... 19
Dimensions d'lnstallation ....................... 19
Consignes d'lnstallation ........................ 20
Interconnexions du Cgblage d'Alimentation ......... 20-21
FONCTIONNEMENT ................................. 22
MISE A L'ESSAI DU COMMUTATEUR DE TRANSFERT
AUTOMATIQUE ............................. 22
S_quence Automatique ............................. 22
Panne de I'alimentation de service ............... 22
R_chauffement du moteur ...................... 22
Transfert ................................... 22
Prise en charge de I'alimentation de service ........ 22
Retransfert .................................. 22
Refroidissement du moteur ..................... 22
Caract_ristiques .................................. 22
ModUle 01813 ................................ 22
ModUle 01814 ................................ 22
Si vous Devez Communiquer avec I'Usine ............. 22
DEPANNAGE ........................................ 23
REMARQUES ........................................ 24
SCHEMAS,VUES ECLATEES, LISTES DES PIECES ......... I0-13
GARANTIE .......................................... 25
16
13_ltl_}:lli_ Commutateur de transfert automaticlue Briggs & Stratton Power Products
Guide d'installation et d'utilisation
RF:GLES DE SF:CURITF:
Ceci est la s_ret_ le symbole vif. II est utilis_ pour
vous alerter aux dangers de blessure personnels
potentiels. Ob_ir tous messages de s6ret_ qui suivent
ce symbole _viter la blessure ou la mort possibles.
Le symbole indiquant un message de s_curit_ est accompagn_ d'un
mot indicateur (DANGER,ATTENTION,AVERTISSEMENT), d'un
message illustr_ et/ou d'un message de s_curit_ visant _ vous
avertir des dangers. DANGER indique un danger qui, s'il n'est pas
_vit_, provoquera des blessures graves, voire fatales.
AVERTISSEMENT indique un danger qui, s'il n'est pas _vit_,peut
provoquer des blessures graves, voire fatales. ATTENTION
indique un danger qui, s'il n'est pas _vit_, peut provoquer des
blessures mineures ou I_g_res. Le mot ATTENTION, Iorsqu'il est
utilis_ sans le symbole d'alerte, indique une situation pouvant
endommager I'_quipement. Suivez les messages de s_curit_ pour
_viter ou r_duire les risques de blessures ou de mort.
Le fabriquant ne peut anticiper toutes les circonstances
potentielles pouvant comporter un danger. Par consequent, les
avertissements contenus dans le present manuel, ainsi que les
plaques et les d_calques appos_s sur I'unit_ n'englobent pas toutes
les possibilit_s. Si vous utilisez une procedure, une m_thode de
travail ou une technique d'op_ration non sp_cifiquement
recommand_e par le fabricant, vous devez vous assurer qu'elle ne
compromet pas votre s_curit_ ni celle des autres.Vous devez
_galement vous assurer que la procedure, la m_thode de travail
ou la technique d'op_ration que vous choisissez ne rende pas la
commutateur de transfert dangereuse.
AVERTISSEMENT
Seuls les_lectriciens et les techniciens en combustibles gazeux
qualifi_s peuvent proc_der g I'installation de ce syst_me,
laquelle doit se conformer strictement aux codes, aux normes
et aux r_glementations applicables.
AVERTISSEMENT
NE touchez PAS les ills d_nud_s ou les bo_tiers.
N'utilisez PAS le commutateur de transfert avec des cordons
_lectriques uses, effiloch_s ou d_nud_s, ou ab_m_s de quelque sorte
que ce soit.
NE manipulez PAS les cordons d'alimentation Iorsque vous _tes
debout dans I'eau, pieds nus ou avec les mains ou les pieds humides.
Si vous devez travaillez autour d'une unit_ alors qu'elle est en marche,
placez-vous sur une surface s_che isol_e afin de r_duire les risques de
choc _lectrique.
NE laissez PAS des personnes non qualifi_es ou des enfants se servir
ou r_parer le commutateur de transfert.
En cas d'accident caus_ par un choc _lectrique, proc_dez
imm_diatement _.la mise hors tension de I'alimentation _lectrique et
contacter des autorit_s locales, IEvitez tout contact direct avec la
victime.
ATTENTION
Ne vous servez du commutateur de transfert que pour les utilisations
pr_vues.
Si vous avez des questions concernant les utilisations pr_vues,
demandez _.votre distributeur ou contactez Briggs and Stratton
Power Products.
N'exposez PAS le commutateur de transfert _.une humidit_ excessive,
de la poussi_re, _.de la salet_ ou 6 des vapeurs corrosives.
En d_pit de la conception s_curitaire du commutateur de transfert, le
fait d'op_rer I'_quipement de fa_on imprudente, de ne pas I'entretenir
ou d'etre n_gligent peut causer des blessures et la mort.
Demeurez alerte en tout temps Iorsque vous travaillez sur cet
_quipement. NE travaillez JAMAIS sur I'_quipement si vous _tes fatigu_
physiquement ou mentalement.
Si les appareils branch_s surchauffent, _teignez-les et mettez leur
disjoncteur ou fusible hors tension.
17
Commutateur de transfert automatique Brig, s & Stratton Power Products 1_1
Guide d'installation et d'utilisation
INTRODUCTION
Nous vous remercions d'avoir achet_ ce commutateur de
transfert automatique de Briggs & Stratton Power Products
(BSPP). Ce commutateur de transfert convient UNIQUEMENT
aux g_n_ratrices de secours r_sidentielles Briggs & Stratton. Ce
produit est conqu pour _tre utilis_ comme groupe _lectrog_ne
optionnel fournissant une source d'_lectricit_ alternative et pour
desservir des charges comme le chauffage, les syst_mes de
r_frig_ration et les syst_mes de communication qui, Iorsqu'ils sont
arr_t_s durant une panne d'_lectricit_, peuvent causer des
inconforts ou autre. Ce produit ne se qualifie pas comme groupe
_lectrog_ne d'urgence tel que d_fini par la NFPA 70 (NEC).
La soci_t_ Briggs & Stratton Power Products (BSPP) a tout fait
pour fournir un commutateur de transfert dont rinstallation soit
s_curitaire, facile et _conomique. Comme chaque installation est
unique, il est impossible de connaitre et de recommander une
marche _ suivre pr_sentant toutes les m_thodes et consignes
d'installation possibles. Briggs et Stratton ignore _galement les
dangers et/ou les r_sultats potentiels de chaque m_thode ou
procedure. C'est pourquoi,
Seuls des entrepreneurs en _lectricit_ qualifi_s devraient
proc_der _ I'installation des commutateur de transfert.
Toute installation doit _tre conforme _ tous codes de
s_curit_ applicables, ainsi qu'aux normes et _ la
r_glementation de Hndustrie.
Votre commutateur de transfert BSPP est livr_ avec le present
"Guide d'installation et d'utilisation". Ce guide est un document
important; conservez-le apr_s avoir compl_t_ I'installation.
Tout a _t_ fait pour s'assurer que les renseignements contenus
dans le present guide soient exacts et _ jour.Toutefois, le
fabriquant se r_serve le droit de changer, de modifier ou encore
d'am_liorer le syst_me en tout temps, et ce, sans pr_avis.
Au Propri_taire R_sidentiel ou
Commercial
Afin de vous aider _ faire des choix avis_s et _ communiquer
efficacement avec rentrepreneur qui proc_dera _ rinstallation,
Veuillez lire avec soin la section Conseils au propri_taire
dans le present guide avant de contracter un
entrepreneur ou de commencer I'installation de votre
commutateur de transfert.
Pour assurer une installation adequate, veuillez contacter le
magasin qui vous a vendu votre commutateur de transfert Briggs
& Stratton Power Products, votre d_taillant ou votre fournisseur
de services d'_lectricit_.
Si Hnstallation du commutateur de transfert n'est pas
effectu_e par des professionnels certifies en
_lectricit_, la garantie sera ANNULI_E.
Au D_taillant ou _ I'Entrepreneur
Proc_dant _ I'lnstallation
T_l_phonez un inspecteur de votre Iocalit_ si vous avez des
questions concernant I'installation.
Si vous avez besoin de renseignements suppl_mentaires,
veuillez appeler au (800) 743-4115 de 8 h _ 17 h HNC.
Conseils au Propri_taire
Les illustrations se rapportent _ des cas typiques et ont pour but
de vous familiariser avec les diff_rentes options d'installation de
votre commutateur de transfert dont vous disposez.
Au moment de n_gocier avec un installateur professionnel, il
faudra tenir compte des facteurs suivants :les codes de s_curit_
Iocaux, I'apparence, et les distances. Souvenez-vous que plus
grandes sont les distances entre le groupe _lectrog_ne et le
service _lectrique existant ainsi que I'alimentation, plus il faudra
faire des compensations dans les mat_riaux et le cgblage. Ces
modifications sont n_cessaires pour vous conformer aux codes de
s_curit_ Iocaux et pour surmonter les chutes de tension.
Les facteurs mentionn_s ci-dessus auront une incidence
directe sur le prix total de Hnstallation de votre
commutateur de transfert.
REMARQUE: Votre installateur est tenu de v_rifier les codes
Iocaux ET d'obtenir les permis requis avant de proc_der
I'installation du syst_me.
Vous devez lire et suivre les instructions indiqu_es dans le
manuel.
i_tablissez un programme de soins et d'utilisation r_gulier de
votre commutateur de transfert, tel qu'indiqu_ dans le manuel.
Responsabilit_s de I'lnstallateur
Vous devez lire et respecter les r_gles de s_curit_ d_crites
dans le manuel.
Vous devez lire et suivre les instructions indiqu_es dans le
present le manuel.
V_rifiez tousles codes f_d_raux, provinciaux et Iocaux.
18
_1 Commutateur de transfert automaticlue Briggs & Stratton Power Products
Guide d'installation et d'utilisation
WERPRODUCTS
Description de I'Equipement
Ce commutateur de nouvelle g_n_ration a _t_ con_u pour
transf_rer la charge complete d'_quipements r_sidentiels courants.
La charge est branch_e _ I'alimentation de service (normal) ou _ la
g_n_ratrice de secours r_sidentielle (urgence). En contrblant la
tension de service et celle de la g_n_ratrice, le commutateur de
transfert se branche automatiquement _ la source d'_lectricit_
appropri_e.
Les principaux _l_ments du commutateur de transfert sont un
interrupteur bipolaire bidirectionnel, un module de commande
comprenant une carte de circuit imprim_, des bornes de
d_tection de tension avec fusible et le cgblage de raccordement.
Le commutateur de transfert _lectromagn_tique est actionn_ par
la tension de service et de la g_n_ratrice et comporte des
contacteurs d'interdiction m_caniques ou _lectriques appropri_s
qui _liminent le risque de brancher I'alimentation de service _ la
sortie de la g_n_ratrice. Sa capacit_ nominale est sufflsante pour
commuter toute la puissance de service de la r_sidence. Le
commutateur comporte un levier de priorit_ pour transf_rer
I'alimentation manuellement.
La carte du module de commande comprend des circuits actifs qui
contrblent les tensions de service et de la g_n_ratrice. Elle produit
les signaux de d_marrage de la g_n_ratrice ainsi que de transfert et
de retransfert Iorsque I'alimentation de service est r_tablie et _ la
fin du refroidissement de la g_n_ratrice. Le module de commande
comprend aussi des voyants rouge et vert indiquant les sources
d'alimentation disponibles et deux contacts commandos par relais
pour le contrble des charges critiques externes.
INSTALLATION
D_ballage
V_rification de la Livraison
Apr_s avoir enlev_ le carton, examinez avec soin les _l_ments du
commutateur de transfert automatique pour tout dommage subi
durant I'exp_dition.
IMPORTANT: Au moment de la livraison, si vous remarquez des
dommages ou des pi_ces manquantes, demandez au livreur de
noter tousles dommages sur la facture de fret et d'apposer sa
signature dans I'espace r_serv_ _ cet effet.Apr_s la livraison, si
vous remarquez des pi_ces manquantes ou des dommages, mettez
les pi_ces endommag_es de cbt_ et communiquez avec le
transporteur pour connaitre les procedures de r_clamation. Les
pi_ces manquantes ou endommag_es ne sont pas garanties.
Contenu de la Boite
Commutateur deTransfertAutomatique
Manuel de d'lnstallation et I'Utilisateur
Dimensions pour I'installation
La Figure 4 illustre les dimensions physiques ainsi que
I'emplacement des trous de fixation du boitier du NEMA 3R
commutateur de transfert. Ce boitier convient uniquement
I'intdrieu r/extdrieur.
L
Dimensions du Bo_tier Dimensions d'lnstallation
ModUle 01813
16'
Dimensions du Boltier
@
@
Dimensions d'Installation
Mod_le 01814
_------,_- -------_1 _"
@
Tel qu'illustr_, le boitier du commutateur de transfert est
g_n_ralement fix_ _ I'aide des trous pr_for_s.
O6"
19
Commutateur de transfert automatique Bri?ags & Stratton Power Products 1_1
Guide d'installation et d'utilisation
Consignes d'installation
Le commutateur de transfert automatique est contenu dans un
bokier de type NEMA 3R adapt_ pour usage interne et externe.
Consignes d'installation du commutateur de transfert automatique:
Installation du commutateur sur une structure portante ferme
et robuste.
Le commutateur doit _tre install_ avec les connexions de
conduit de fo de materiel de NEMA 3R minimum.
Au besoin, nivelez le commutateur pour _viter les distorsions.
Ceci peut _tre accompli en ins_rant des rondelles entre le
bo_tier du commutateur et la surface de fixation.
NE JAMAIS installer le commutateur dans un endroit une
substance corrosive pourrait s'y infiltrer.
Prot_gez le commutateur en tout temps contre I'humidit_, les
poussi_res, les salet_s, les peluches, le gravier et les vapeurs
corrosives.
La Figure 5 illustre un commutateur de transfert automatique
typique. II est recommand_ d'installer le commutateur pros du
compteur de I'alimentation de service, soit _ I'int_rieur ou
I'ext_rieur. Discutez des suggestions/changements de disposition avec
le propri_taire avant d'entamer le processus d'installation du syst_me.
Interconnexions du Cgblage
d'Alimentation
Tout le c_blage doit _tre d'un gabarit appropri_, bien fix_, et
prot_g_ par des conduits.
Effectuez les raccords suivants entre le commutateur de transfert,
le panneau de distribution principal, I'alimentation de service et la
g_n_ratrice (Figure 6).
I. Assurez-vous que I'alimentation de service est HORSTENSION.
Raccordez les ills d'alimentation de service aux bornes "UTILITY
CONNECTION" du commutateur de transfert.
2. Raccordez le neutre de service _ la borne "NEUTRAL" du
commutateur de transfert.
CAUTION
3,
4,
5.
6,
7.
8.
9.
10.
II.
L'omission de suivre cet avertissement pourrait entrainer des
dommages _ l'_quipement etlou son mauvais fonctionnement.
Raccordez les fils d'alimentation du panneau de distribution
principal aux bornes "LOAD CONNECTION" du
commutateur de transfert.
Raccordez le fil neutre du panneau de distribution principal
la borne "NEUTRAL" du commutateur de transfert.
Raccordez les fils d'alimentation du panneau de commande
de la g6n6ratrice aux bornes "GENERATOR
CONNECTION" du commutateur de transfert.
Raccordez le neutre du panneau de commande de la g6n6ratrice
la borne "NEUTRAL" du commutateur de transfert.
Raccordez le "GND" du panneau de commande de la
g6n6ratrice _ la borne "GND" du commutateur de transfert.
Raccordez le "GND" du panneau de distribution principal _ la
borne "GND" du commutateur de transfert.
Raccordez les bornes de d_tection de I'alimentation de
service de la g_n_ratrice aux bornes de d_tection de
I'alimentation du commutateur de transfert.
La barrette de raccordement du module de commande du
commutateur de transfert comporte quatre raccords _ I'usage
du client. Deux ensembles de contacts "normalement ferm6s"
sont disponibles; ils sont activ6s Iorsque la g6n6ratrice est
mise en marche. IIs peuvent servir _ contr61er d'importantes
charges branch6es _ la g6n6ratrice ou une alarme.
Serrez au couple appropri6 tousles raccords de ills et
attaches.
[il'l'l'l'l'l'l'l'[_._ I,_,...........IIII_I_I__m _ I_;'_'_i
r_
r'_
r_
r_
/
Panneau du
disioncteur
principal
_ommutateur de
Transfert i
de l'alimentation
de service
G_n_ratrice
20
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36

Briggs & Stratton 01813-0 Owner's manual