continuedfrompage7
Forwall or roofventingmethods:
Choose betweenroof venting or wall venting.
If the wall exhaustmethod is chosen, be sure that there is
proper clearancewithin the wall for the exhaustvent.
Vent materialsneededfor installationare notincluded.
Wall and roofcapsmusthaveback-draftdamper.
We recommend:
v' using rigid metal vent.
v' that length of vent and number of elbows should be
kept to a minimum to provide efficient performance.
v' that size of vent should be uniform.
v' using duct tape to seal all joints inthe vent system.
v' using caulking compound to seal exterior wall or roof
opening around cap.
v' two elbows should not be installed together.
We do NOTrecommend:
v' flexible metal vent.
NOTE:If flexible metal vent must be used, calculateeach
foot of flexible metal vent as two feet of rigid metal vent.
Flexiblemetal elbows count twice as muchas standard
elbows.
Roofventing
Salida de alre perel cieloraso
roof cap
¢aperuzade cielo raso
3-1/4"x10"through*the-roof
atrav_sdelcielorasoperunorificio
de3-1/4"x10
Wall venting
Salida de alre perla pared
wallcap
caperuz_depared
3-1/4" x 10" through-the*wall
a trav6s de la paredpar un
orificio de 3-1/4" x10
Roundventtransition
Transici6nde conductode salidade aire redondo
roof cap _ _,.,-,.._
caperuzade _ / k
cielo raso
6" min. diameter roundvent _ [ [ wall sap
conductode salida de aire ] ."-_t_. ...... ._,._,..M_-,_
redondode6"dedi_metro I" I _ _---, ,_ ._-_-'.=_._
coda
3-1/4" x10" to 6" round vent
transition
transicibndeconductodesalida
3" minimum height (required
for damper to fully open)
Altura minima de 3"
(necesaria para qua la
compaerta se abra
nompletamente)
deaireredondode3-1/4"x 16"
a6"
vienedelap_,gina7
Para m_todos desalida de aire a trav6sde la paredoel
cielo raso:
Decidaentre instalar la salidade aire a travds del cielo raso o
de una pared.
Si sedecide par el mdtodo de salida deaire a travds de la
pared,aseg_resede que hayael espacio adecuadodentro de
la pared parael conducto de salidade aire.
No se incluyenlos materiales del conductode salida deaire
que se necesitanpara la instaiaci6n.
Las caperuzaspara cielorasoy pareddebentener
compuertadecontratiro.
Recomendamos:
v' usar un conducto de salidade aire met_lico y rigido.
v' que la Iongitud del conducto de salida de aire y el n_mero
de codas se mantengana un minima pareIograr un
rendimiento eficiente.
v' que las dimensiones del conducto sean uniformes.
v' usarcinta pareconducto paresellartodas las unionesen el
sistema de salidade aire.
v' usar masilla parecalafatearparesellar la pared exterior ola
abertura en el cielo rasoalrededor de la caperuza.
v' no se deben instalar dos codas juntos.
No recomendamos:
v' conducto de salida de aire met_licoflexible
NOTA:si debeusarse un conducto metdlico flexible, calcule
cada pie de conducto metdlicoflexible coma si fueran dos pies
de conducto metdlico rigido. Los codas de metal flexible hacen
par dos codas estdndar.
8
Recommendedventlength:
Use3-1/4°X 10" rectangular or 6" round vent.
Thetotal length of the vent system including straight vent,
elbow, transitions, wall or roof caps must not exceedthe
equivalent of 140 feet of 3-1/4" X 10"rectangular or 6"
diameter round vent.
Forbest performance, use no more than three 90 degree
elbows.
Tocalculatethe length of system you need,add the
equivalent feet for eachvent pieceused in the system. See
the following examples:
3-1/4"x 10" ventsystem:
1 - 3-1/4" x 10"
90° elbow = 25 ft.
1 - wall cap = 40 ft.
8 feet straight 8 ft.
Length of
3-1/4" x 10" system = 73 ft.
6"vent system:
1 - transition = 5 ft.
2 - 90° elbows 20 ft.
1 - wall cap = 40 ft.
8 feet straight 8 ft.
Lengthof 6"system = 73 ft.
If the existing vent is round, a rectangular-to-round adapter
must be usedand a rectangular 3" extensionvent between
the damper assembly and adapter must be installedto
preventdamper from sticking.
Recommendedstandardfittings
Accesoriosest_ndarrecomendados
3-1/4"x lO"to 6"=5ft.
De3-1/4"x1_'a6"=
5pies
3-1/4'x 10"roofcap=24ft.
Capemzadecielorasode
3-1/4"x10'=24pies
3-1/4"x10"
90_dbow=25 ft.
Codede90°y 3-1/4"x
1_' =25pies
90°elbow=lOft.
CododegO_=
10pies
3-1/4"x10"wallca
=40ft.
Coperuzadepared
de3-1/4"x10"=
40pies
45° elbow=5ft.
Codade45°=
5 pies
3-1/4"x10'flat
eibow= 10ft.
Codapianode3-1/4"
x 10"= 10pies
3-1/4"x 10"ventsystem
Sistemade salidade aire de 3-1/4"x 10"
3-1/4" x 16"
90° elbow
Codade90° y 6It.
3-1/4"x1_ _6pies_ n wallsap
T" ] I H_caperuzade
' I}> parud
U 2_t. (2 pies)
6"vent system
Sistemade salidade aire de 6"
90° elbows
codode 90°
2
transition
transici6n
2 ft. (2 pies)
Longitudrecomendadadel conductode salidade aire:
Useun conducto de salidade aire rectangularde 3-1/4_x 10"
o redondo de 6".
La Iongitud total del sistema de salida de aire, incluyendo el
conducto de salidade aire recto, el coda, lastransiciones, las
caperuzasde pared o cielo raso nodeben excederel
equivalentea 140 piesde conducto rectangular de salida de
aire de 3-1/4" x 10" o conducto redondo de 6" de didmetro.
Paramejores resultados, no usem_s de tres codas de 90°.
Paracalcular la Iongitud del sistema que necesita,agregue la
equivalenciaen pie para cadapedazode conducto usado en el
sistema. Vealos siguientesejemplos:
Sistemade salidade aire de 3-1/4"x 10":
1 - Coda de 90°
y 3-1/4" x 10" = 25 pies
1 - Caperuzade pared = 40 pies
8 pies recto = 8 pies
Longitud de un
sistema de 3-1/4"x 10" = 73 pies
Sistemade salidade aire de 6"
1 -transici6n = 5 pies
2 - codas de 90° 20 pies
1 - caperuzade pared = 40 pies
8 pies recto 8 pies
Longitud de un
sistema de 6" = 73 pies
Si el actual conducto de salidade aire es redondo,debe usarse
un adaptadorde rectangulara redondo y un conducto de
extension rectangular de 3"entre el conjunto de la compuerta
y se debe instalar el adaptador pare evitar que la compuerta se
atasque.
9