LMI XRD141-A76VCN7PN Owner's manual

Type
Owner's manual
Excel
®
XR Series
Electronic Metering Pump
Installation & Operation Manual (Enhanced Control)
Manual No.: 54772
Revision : 02
Rev. Date: 07/2017
Note: This manual is a supplement to 54630
(866) 433-6682 • (281) 359-8538 • [email protected] • www.novatech-usa.com
Table of Contents
1.0 Precautions ....................................................................................... 1
2.0 Introduction ...................................................................................... 4
3.0 Icons .................................................................................................. 4
4.0 Enhanced Control Operation ........................................................... 6
4.1 Analog Mode ................................................................................................... 6
4.2 Pulse Mode ..................................................................................................... 7
4.3 Batch Mode ..................................................................................................... 9
4.4 Cycle Timer ................................................................................................... 10
4.5 Timed Event Mode ........................................................................................ 12
4.6 Enhanced Control Inputs and Outputs .......................................................... 13
4.6.1 Inputs .................................................................................................... 14
4.6.1.1 Remote Internal/External Mode .................................................. 14
4.6.1.2 Analog Tank Level Input ............................................................. 15
4.6.1.3 Configuring Enhanced Control Inputs ......................................... 15
4.6.2 Outputs ................................................................................................. 16
4.6.2.1 Stroke Pulse ............................................................................... 17
4.6.2.2 Pump Running ............................................................................ 17
4.6.2.3 Pump Standby ............................................................................ 17
4.6.2.4 Alarm Out ................................................................................... 17
4.6.2.5 Internal/External Mode ............................................................... 17
4.6.2.6 User Alarm Out ........................................................................... 18
4.6.2.7 Pump Stopped ............................................................................ 19
4.6.2.8 Timed Event ............................................................................... 19
4.6.2.9 Flow ............................................................................................ 19
4.6.2.10 Mirror Input AI1 ........................................................................... 19
4.6.2.11 Configuring Enhanced Control Outputs ...................................... 19
5.0 Cable Wiring ................................................................................... 20
6.0 Troubleshooting ............................................................................. 23
(866) 433-6682 • (281) 359-8538 • [email protected] • www.novatech-usa.com
Table of Figures
Figure 1: Analog Mode Home Screen ............................................................................. 6
Figure 2: Analog Adjust ................................................................................................... 6
Figure 3: Pulse Mode Home Screen ............................................................................... 8
Figure 4: Pulse Adjust ..................................................................................................... 8
Figure 5: Batch Mode Home Screen ............................................................................... 9
Figure 6: Batch Adjust ................................................................................................... 10
Figure 7: Cycle Timer Home Screen ............................................................................. 11
Figure 8: Cycle Timer Adjust ......................................................................................... 11
Figure 9: Timed Event Home Screen ............................................................................ 12
Figure 10: Timed Event Adjust ...................................................................................... 13
Figure 11: Int/Ext Select ................................................................................................ 15
Figure 12: Configure Input ............................................................................................. 16
Figure 13: Alarm Set ..................................................................................................... 18
Figure 14: Configure Output .......................................................................................... 19
Figure 15: Cable Wiring Diagram .................................................................................. 20
Figure 16: Input Diagram for Digital Inputs DI1 - DI4 .................................................... 21
Figure 17: Output Diagram for Digital Outputs DO1 DO2 ........................................... 21
Figure 18: Input Diagram for Analog 0-20mA Inputs AI1 - AI2 ...................................... 22
Figure 19: Output Diagram for Analog 4-20mA Output AO1 ......................................... 22
(866) 433-6682 • (281) 359-8538 • [email protected] • www.novatech-usa.com
PRECAUTIONS
1
1.0 Precautions
The following precautions should be taken when working with LMI metering pumps.
Please read this section carefully prior to installation.
Protective Clothing
ALWAYS wear protective clothing, face shield, safety glasses and gloves when working on or
near your metering pump. Additional precautions should be taken depending on the solution
being pumped. Refer to Safety Data Sheets (SDS) precautions from your solution supplier.
Water Pre-Prime
All LMI pumps are pre-primed with water when shipped from the factory. If your solution is not
compatible with water, disassemble the Pump Head Assembly. Thoroughly dry the pump head,
valves, O-rings, balls and diaphragm. Reassemble head assembly tightening screws in a
crisscross pattern. Refill the pump head with the solution to be pumped before priming the
pump. (This will aid in priming.)
Liquid Compatibility
CAUTION: The evaluation performed by ETL was tested with water only. The pumps are
certified to NSF 61 with: sodium hypochlorite (12.5%), sulfuric acid (98.5%), sodium hydroxide
(50%), and hydrochloric acid (30%). Determine if the materials of construction included in the
liquid handling portion of your pump are adequate for the solution (chemical) to be pumped.
Always refer to the solution supplier and the Milton Roy Chemical Resistance Chart for
compatibility of your specific Milton Roy metering pump. Contact your local Milton Roy distributor
for further information.
Tubing Connections
Inlet and outlet tubing or pipe sizes must not be reduced. Outlet tubing size must not be
increased. Make certain that all tubing is SECURELY ATTACHED to fittings prior to start-up (see
section 3.3 Tubing Connections). ALWAYS use LMI supplied tubing with your pump, as the
tubing is specifically designed for use with the pump fittings. It is recommended that all tubing be
shielded and secure to prevent possible injury in case of rupture or accidental damage. If tubing
is exposed to sunlight, black UV resistant tubing should be installed. Check tubing frequently for
cracks and replace as necessary.
Fittings and Machine Threads
All fittings should be hand-tightened. An additional 1/8 - 1/4 turn after the fitting is snug may be
necessary to provide a leak-proof seal. Excessive overtightening or use of a pipe wrench can
cause damage to the fittings, seals, or pump head.
Most LMI pumps have straight screw machine threads on the head and fittings and are sealed
by the O-rings. DO NOT use Teflon® tape or pipe dope to seal these threads. Teflon® Tape
may only be used on NPT threads.
Plumbing
Always adhere to your local plumbing codes and requirements. Be sure installation does not
constitute a cross connection. Check local plumbing codes for guidelines. LMI is not responsible
for improper installations.
(866) 433-6682 • (281) 359-8538 • [email protected] • www.novatech-usa.com
PRECAUTIONS
2
Back Pressure/Anti-Syphon Valve
If you are pumping downhill or into low or no system pressure, a back pressure /anti-syphon
device should be installed to prevent over pumping or syphoning. Contact your LMI distributor
for further information.
Electrical Connections
WARNING: To reduce the risk of electrical shock, the metering pump must be plugged into a
properly grounded grounding-type receptacle with ratings conforming to the data on the pump
control panel. The pump must be connected to a good ground. Do not use adapters! All wiring
must conform to local electrical codes. If the supply cord is damaged, it must be replaced by the
manufacturer, stocking distributor, or authorized repair center in order to avoid a hazard.
Fuse (all models) and Battery
CAUTION: Battery may explode if mistreated. Do not recharge, disassemble or dispose of in fire.
The battery and fuse are internal, factory serviceable parts, and must be replaced by the factory
or a qualified distributor with parts of the same type and rating.
Flooding
WARNING: Install this pump in a location where flooding cannot occur.
Ground Fault Circuit Interrupter
WARNING: To reduce the risk of electric shock, install only on a circuit protected by a Ground
Fault Circuit Interrupter (GFCI).
Line Depressurization
To reduce the risk of chemical splash during disassembly or maintenance, all installations
should be equipped with line depressurization capability.
Over Pressure Protection
To ensure safe operation of the pump it is recommended that some type of safety / pressure-
relief valve be installed to protect the piping and other system components from failing due to
excessive pressure.
Chemical Concentration
There is a potential for elevated chemical concentration during periods of no flow, for example,
during backwash in the system. Steps, such as turning the pump off, should be taken during
operation or installation to prevent this.
See your distributor about other external control options to help mitigate this risk.
Retightening Components
Plastic materials will typically exhibit creep characteristics when under pressure over a period of
time and to insure a proper fit it may be necessary to retighten the head bolts periodically. To
insure proper operation, we recommend tightening the bolts to 25 inch-pounds after the first
week of operation and on a monthly basis thereafter.
(866) 433-6682 • (281) 359-8538 • [email protected] • www.novatech-usa.com
PRECAUTIONS
3
Flow Display
The accuracy of the flow value as shown on the pump display is highly dependent on the
specific application. Calibration is necessary in order to display an accurate measure of the flow.
Spills
CAUTION: Spills of Dangerous chemicals should be cleaned up immediately.
(866) 433-6682 • (281) 359-8538 • [email protected] • www.novatech-usa.com
OPERATION
4
2.0 Introduction
LMI's metering pumps deliver the highest level of repetitive accuracy and reliability
with the capability to pump a wide range of chemicals. Our comprehensive selection
of pumps means you get the right pump for the right application. Every one of our
pumps is engineered to exceed expectations and is backed by a global network of
highly trained field engineers and aftersales support.
This manual serves as a supplement to the Excel
®
XR Series Electronic Metering
Pump Installation & Operation Manual, part number 54630. It covers information
specific to the use, configuration and wiring of the additional modes of operation
available in the enhanced control model pumps.
Please review this manual carefully. Pay particular attention to warnings and
precautions. Always follow good safety procedures, including the use of
proper clothing, eye and face protection.
3.0 Icons
Table 1 explains the function of display screen icons not covered in the 54630 manual.
Table 1: Enhanced Pump Icons
Mode select
Manual mode
Analog mode
Batch mode
Pulse mode
Cycle timer mode
Timed event mode
Dosing is in progress
(866) 433-6682 • (281) 359-8538 • [email protected] • www.novatech-usa.com
OPERATION
5
Analogue pacing signal (loss of signal alarm)
Analogue pacing signal (signal over range)
Pulse input not synched
Max pump volume exceeded (in pulse mode)
Max flow exceed in batch mode
(866) 433-6682 • (281) 359-8538 • [email protected] • www.novatech-usa.com
OPERATION
6
4.0 Enhanced Control Operation
This manual covers features supported in the enhanced control model Excel
®
XR Series
pumps. Enhanced control features are driven by a variety of external inputs and outputs.
Please see section 5.0 Cable Wiring for information on connections, signal types, and
requirements.
4.1 Analog Mode
Analog mode allows control of the pump using an external 0 - 20 mA signal. The analog
mode home screen is shown in Figure 1.
Figure 1: Analog Mode Home Screen
To configure the analog mode input parameters, press the Up or Down buttons to
access the analog adjust screen (Figure 2).
Figure 2: Analog Adjust
Point 1
Point 2
Flow Rate
Input Current
(866) 433-6682 • (281) 359-8538 • [email protected] • www.novatech-usa.com
OPERATION
7
Press Left or Right to navigate to the parameter entry boxes. Enter the desired
flow rates and currents at points P1 and P2. The range of allowable values for flow rate
are from zero to the maximum capacity of the pump. Input signal current can range from
0.0 to 20.0 mA. Press Save to retain the entered values and Exit to return to the
analog mode home screen. Press Exit without pressing Save to exit without
modifying the parameters.
The linear relationship between signal current and flow can be increasing or decreasing.
If the input signal is outside the operating range defined by the values entered by the
user, the pump output will plateau at the defined flow limits. If the current exceeds 22 mA
the Signal Over Range icon will appear in the notification bar.
Any input current value of 0.5 mA or less will cause the pump to stop pumping and the
Loss of Signal icon will appear in the notification bar. The pump status indicator will
remain green, showing the pump is still in “run” mode. When the input current rises
above 0.5 mA again, the pump will resume pumping and the Loss of Signal icon
will be cleared from the notification bar.
Press the Start / Stop button to make the pump dose at the calculated flow rate. Starting
and stopping can be done manually by pushing the Start / Stop button or remotely using
the Remote Start / Stop function.
4.2 Pulse Mode
In pulse mode, the pump delivers a programmable volume of fluid, for a programmable
number of incoming pulses from an external device (typically a flow meter). The result is
a flow output that varies as the frequency of the incoming pulses varies, allowing the
pump to track the external input.
From the pulse mode home screen (Figure 3) press the Up or Down buttons to get to
the pulse adjust screen (Figure 4).
(866) 433-6682 • (281) 359-8538 • [email protected] • www.novatech-usa.com
OPERATION
8
Figure 3: Pulse Mode Home Screen
Figure 4: Pulse Adjust
FIELD
ALLOWABLE VALUES
Pulse Count
1 - 10000
Volume
0.1 - 10000
Units
fl. oz. GAL or mL L (dependent on units setting)
Pulse Width
4 mS 60 mS
Refer to the manufacturer’s documentation for information regarding the external device
providing the pulse input. In general, larger numbers result in better output resolution.
Some devices are capable of operating in varying frequency and pulse widths. The
minimum recommended pulse width is 4 mS (milliseconds). Set the pulse width to a
value less than the minimum pulse width of the external device. Press Save to retain
the entered values, then press Exit to return to the pulse mode home screen, or
Flow Rate
Pulse Volume / Units
Pulse Width
# of Pulses
(866) 433-6682 • (281) 359-8538 • [email protected] • www.novatech-usa.com
OPERATION
9
press Exit to exit without modifying the parameters. For devices with pulse widths
less than 4mS, use digital input DI1.
In pulse mode, when the pump receives a pulse stream, the calculated flow output value
will be displayed. The Start / Stop button must be pressed or Remote Start / Stop
activated for the pump to dose at the calculated flow rate. The Pump Status Indicator
will be illuminated and the pump will operate at the flow rate derived from the pulse
mode settings. At least two pulses must be sensed or the Pulse Not Synced icon
will appear on the notification bar. If the pulse stream results in a calculated flow rate
greater than the pumps calibrated maximum volume the pump will dose at the maximum
flow rate and the Max Pump Volume Exceeded icon will appear in the notification
bar until the pulse rate decreases.
4.3 Batch Mode
In batch mode, upon receiving a single pulse, the pump delivers the programmed
volume of fluid in the programmed amount of time.
FIELD
ALLOWABLE VALUES
Batch Volume
0.01 to 10,000 (current version only 9999.90)
Units
Fl oz/GAL or mL/L depending on units setting
Dosing Time (Seconds)
1 to 86400
Calculated Flow Rate
0.001 to Maximum Capacity
Pulse Width (Milliseconds)
4 to 60
Figure 5: Batch Mode Home Screen
1. From the Batch Mode home screen (Figure 5) press the Up or Down buttons
to go to the Batch Adjust screen (Figure 6).
% Batch Remaining
Time Remaining
Volume Remaining
(866) 433-6682 • (281) 359-8538 • [email protected] • www.novatech-usa.com
OPERATION
10
2. Enter the values for the quantity and units of the volume of fluid to be dosed
(Figure 6).
NOTE: If a set of entered values results in a condition that exceeds the pumps
maximum calibrated flow, the field will be highlighted red. Increase or decrease this or
one of the other parameters to clear the condition.
3. Enter the pulse width after consulting the documentation for the device that
will generate the pulse.
4. Select the Pulse Accumulator feature, as needed.
5. Press Save and Exit to return to the Batch Mode home screen.
6. Press the Start / Stop button, the Pump Status Indicator will glow green, and
the pump will be ready to receive and act upon an incoming pulse.
Figure 6: Batch Adjust
Once the pump is started and one a pulse is received, the Dosing icon will appear in
the notification bar. If the pump receives a pulse before the current batch is complete
and the Pulse Accumulator box is checked, the pump will accumulate input pulses and
finish the current batch before moving on to the next. The display screen will show the
remaining batch volume, time, and %.
If the pump receives a pulse before the current batch is complete and the Pulse
Accumulator box is not checked, the current batch is reset and a new batch starts
immediately.
4.4 Cycle Timer
The cycle timer allows the user to establish a continuously repeating cycle of pump on
and off times.
Batch Volume / Units
Dosing Time
Calculated Flow
(866) 433-6682 • (281) 359-8538 • [email protected] • www.novatech-usa.com
OPERATION
11
Figure 7: Cycle Timer Home Screen
1. From the cycle timer home screen (Figure 7) press the Up or Down buttons
to access the cycle timer adjust screen (Figure 8).
2. Enter the desired values for delay, duration and cycle times by pressing Left
or Right to navigate between fields.
NOTE: Delay is the time before the initial cycle starts, Duration is the time in which the
pump is operating, and Cycle is the duration plus off time before the next cycle starts.
3. Enter the desired flow rate.
NOTE: If a set of entered values results in a calculated flow that exceeds the pumps
maximum calibrated flow, the calculated flow field will be highlighted red. Modify one or
more of the parameters until the calculated flow rate is within the pumps flow range to
clear the condition (Figure 8).
4. Press Save and Exit to return to the home screen.
Figure 8: Cycle Timer Adjust
Cycle Parameters
Delay
Run
Cycle
(866) 433-6682 • (281) 359-8538 • [email protected] • www.novatech-usa.com
OPERATION
12
FIELD
ALLOWABLE VALUES
Delay (hr:min)
0:01 to 23:59
Duration (hr:min)
0:01 to (Cycle setting - 0:01)
Cycle (hr:min)
0:01 to 23:59
Calculated Flow
0.1 to Maximum Capacity
The clock starts when the Start / Stop button is pressed or a remote start signal is
received. Pressing the Start / Stop button or toggling the Remote Start / Stop input
while the cycle timer process is running will cancel the process. Starting the pump again
will restart the process from the beginning, including delay. The delay will only be active
during the initial cycle and will not repeat until the pump has been stopped and restarted.
The screen will reflect the current state (delay, run, cycle) and time remaining.
4.5 Timed Event Mode
In timed event mode, four different events can be programmed for each day of the week.
Each event consists of a start time, duration and a flow rate. The next event data is
displayed on the time event home screen (Figure 9).
Figure 9: Timed Event Home Screen
Before programming, ensure that the Time/Day settings in the pump are correct.
(Navigate to Settings Time/Day to update.) From the timed event home screen press
the Up or Down buttons to enter the timed event adjust screen (Figure 10).
Day, Time,
Flow Rate, &
Duration of
Next Event
(866) 433-6682 • (281) 359-8538 • [email protected] • www.novatech-usa.com
OPERATION
13
Figure 10: Timed Event Adjust
FIELD
ALLOWABLE VALUES
Start Time (hr:min)AM/PM
0:01 to 12:00 AM/PM
Duration (hr:min)
0:01 to (Cycle setting - 0:01)
Flow Rate
0.001 to Maximum Capacity
1. Press Left and Right to navigate and the Up and Down buttons to set
start time, duration and flow rate. Enter the parameters for as many as four
events for each day of the week. The enable/disable column on the left allows
multiple choices to be entered (Figure 10).
2. Press the Up or Down buttons to fill the event on/off box and enable the
event.
3. Press Save and Exit to return to the home screen. Once the settings
have been saved, the list will sort in chronological order with events not active
appearing below any active events.
4. Press the Stop / Start button or assert a remote start to ready the pump. The
pump status indicator will illuminate. At the time and day shown for the next
event, the pump will start and dose for the programmed amount of time at the
programmed flow rate. Once an event has completed, the next active event
will be shown on the home screen with the pump idle until the event occurs.
If overlapping events are programmed the active event will be overridden by subsequent
timed events.
4.6 Enhanced Control Inputs and Outputs
In addition to the enhanced modes of operation, the enhanced control model pumps
include a variety of inputs and outputs to benefit the user.
Event Parameters
Event On/Off
Day of Week
(866) 433-6682 • (281) 359-8538 • [email protected] • www.novatech-usa.com
OPERATION
14
4.6.1 Inputs
Enhanced control model pumps have four digital and two analog configurable inputs.
Digital inputs are labeled DI1 DI4. Analog inputs are AI1 and AI2. See section 5.0
Cable Wiring, for the cable and pin assignments for each of these inputs.
Each digital input can be assigned to one of five functions or <Disable>. The analog
inputs can be assigned one of two functions plus <Disable>. The functions are listed in
the table below.
Input Type
Function
Use
Digital
<Disable>
De-activates input
Remote Start/Stop
Externally toggles start/stop
Tank Level Switch Empty
Triggers “Tank Empty” alarm
Tank Level Switch Low
Triggers “Tank Low” alarm
Remote Internal/External Mode
Toggles internal/external control
External Control Pacing Pulse
Input signal for Pulse Mode
Analog
<Disable>
De-activates input
Pacing
Input signal for Analog Mode
Tank Level
Triggers “Tank Empty” or “Tank Low” alarm
The Remote Start/Stop, Tank Level Empty and Tank Level Low functions are included in
manual control model pumps. The operation of these features is described in the
operation manual part number 54630.
4.6.1.1 Remote Internal/External Mode
Pump operation and output flow rate is controlled by either internal (user input/internal
timer) or external (outside signal) modes. These modes are listed in the table below.
Internal Control
External Control
Manual Mode
Analog Mode
Cycle Timer Mode
Pulse Mode
Timed Event Mode
Batch Mode
The Remote Internal/External Mode toggles the operating mode between internal and
external control. The user defines one mode each for internal and external control types.
1. From the settings screen, navigate to Int/Ext Select and press Enter .
2. Press Left and Right to move between mode choices.
3. The Up and Down buttons select and de-select modes.
(866) 433-6682 • (281) 359-8538 • [email protected] • www.novatech-usa.com
OPERATION
15
4. Press Save and Exit .
Figure 11: Int/Ext Select
With the selections shown above, the input configured per section 4.6.1.3 Configuring
Enhanced Control Inputs, and cable hookups per section 5.0 Cable Wiring, a Remote
Internal/External signal will toggle the pump between manual and analog modes.
4.6.1.2 Analog Tank Level Input
Selecting this input overrides the digital tank level empty and tank level low inputs and
combines both functions into one analog signal. When the 4 - 20 mA input signal drops
to 6.4 mA (15%) the tank level low alarm will be enabled. When it reaches 4.8 mA (5%),
the tank level empty alarm will be enabled.
4.6.1.3 Configuring Enhanced Control Inputs
Input signals are assigned on the configure input screen (Figure 12).
Internal Mode
External Mode
(866) 433-6682 • (281) 359-8538 • [email protected] • www.novatech-usa.com
OPERATION
16
Figure 12: Configure Input
In the Settings screen, navigate to configure input and press Enter . Press Left
and Right to navigate between fields and the Up and Down buttons to make
selections. Each input can be identified as NO (normally open) or NC (normally closed).
If testing produces the opposite effect from what is desired, frequently an easy solution
is to change the switch type from NO to NC or vice versa. Note that selecting a function
for one input makes it unavailable in others.
4.6.2 Outputs
Enhanced control model pumps have two digital and one analog configurable output.
Digital outputs are labeled DO1 and DO2. The analog output is labeled AO1. See
section 5.0 Cable Wiring, for the cable and pin assignments for each of these outputs.
Each digital output can be assigned to one of eight functions plus <Disable>. The analog
output can be assigned one of two functions plus <Disable>. The functions are listed in
the table below.
Digital Inputs 1-4
Analog Inputs 1-2
(866) 433-6682 • (281) 359-8538 • [email protected] • www.novatech-usa.com
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29

LMI XRD141-A76VCN7PN Owner's manual

Type
Owner's manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI