Alfa Network BC-29 Installation & Programming Manual

Type
Installation & Programming Manual
Barcode
BC-29
Programming Manual
Decoder & Platform
1
Getting Started .................................................................2
Setting Procedures ………...............................................3
Setting Flow Chart ................................ ..........................4
Group 1 : Multi Validation......………………………….5
Group 2 : Hold Time .……………………………….….6
Group 3: Scan Mode……………………………………7
Group 4: End Character………………………………...7
Group 5: Sleep Time……………………………………8
Group 6: Barcode Identify………………………….......9
Group 7-1: EAN-13 ……………….………………......10
Group 7-2: EAN-8…………………………………......11
Group 7-3: UPC-A…………………………………12-13
Group 7-4: UPC-E…………………………………14-15
Group 7-5: ADD-ON 2/5 ……………………………..16
Group 8: Codabar……………………………..……17-18
Group 9: Code128 ………………………………….....19
Group 10: Code39………………………………….20-21
Group 11: Code93……………………………………..22
Group 12: Code11 ………………………………….....23
Group 13-1: Interleaved 2 of 5………………………...24
Group 13-2: Industrial 2 of 5 ………………………....25
Group 13-3: Matrix 2 of 5 ………………………….....26
Group 13-4: MSI-PLESSEY ……………………….....27
Group 14: Keyboard Language………………………..28
Group 15: 1D 2D Select ………………………………29
Group 16: Edit Function ………………………………30
Group 17-1: Parameter (NUMBER) ………………33-37
Group 17-2: Parameter (ASCII) …………………...37-43
CONTENTS
2
Getting Started
To install a USB Interface scanner, follow the steps
listed below:
1) Make sure that the scanner has the correct USB
cable for the system ( PC or terminal)
2) Turn off the power of the system
3) plug the USB cable
4) Turn on the power of the system
5) If the indicator LED lights up and the buzzer
sounds, the scanner is ready for reading
To install a RS-232 interface scanner, the host device
should have a RS-232 port to receive data from the
scanner, follow the steps listed below:
1) Make sure that the scanner has the right connector
for the RS-232 port of the host device
2) Make sure that there is a power supply to the
scanner (if necessary)
3) Connect the cable to the RS-232 port of the device
4) If the indicator LED lights up and the buzzer
sounds, the scanner is ready for reading
Installing USB Interface Scanner
Installing a RS-232 Interface Scanner
Example 2
Assign Preamble string as “A"
1) Scan barcode “Insert and clear 1” from “Edit
Functiongroup
2) Scan barcode “01” from “Parameter (NUMBER)”
group
3) Scan barcode “Afrom “Parameter (ASCII)” group
4) Scan “Save" barcode
Setting Procedures
1) Locate a group that contains the parameters to be
changed.
2) Scan the Setting label. The scanner will
sound beeps indicate that set is in progress
3) Scan the label representing the parameter to be
changed
4) Scan the “Save" to end the group currently selected,
the scanner will sound beeps
5) Repeat the procedure for other groups including the
parameters to be changed
Example 1:
Set the operating mode to “20 Lines Scan mode"
1) Scan barcode “20 Lines” from “Scan mode” group
2) Scan “Save“ barcode
3
Setting Flow Chart
SELECT COMMANDS
PARAMETER
(OPTIONAL)
Set Default to Factory
Show Version
4
SAVE
Group 1: Multi Validation
1 time
2 times
3 times
4 times
5 times
Save
5
Group 2: Hold Time
100 ms
200 ms
300 ms
400 ms
500 ms
Save
6
Group 3: Scan Mode
20 lines
100 lines
End by Tab
End by Enter
Save
Group 4: End Character
7
Disable
Group 5: Sleep Time
Disable
1 min
3 min
2 min
Save
4 min
5 min
6 min
8
Group 6: Barcode Identify
Barcode identify off
Barcode ID symbol on left
Barcode ID symbol on right
Save
9
Group 7-1: EAN-13
Enable
Disable
Save
Verify Checksum
Disable
Enable
Transmit Check Character
Enable
Disable
Disable
Enable
EAN-13 Convert to ISBN
10
Group 7-2: EAN-8
Enable
Disable
Save
Verify Checksum
Disable
Enable
Transmit Check Character
Enable
Disable
11
Group 7-3: UPC-A
Enable
Disable
Save
Verify Checksum
Disable
Enable
Transmit Check Character
Enable
Disable
Enable
UPC-A Convert to EAN-13
Disable
12
Group 7-3: UPC-A
Save
Truncate Leading Digit
Truncate the system character
Truncate the first zero
Disable
Truncate Leading zero
13
Group 7-4: UPC-E
Enable
Disable
Save
Verify Checksum
Disable
Enable
Transmit Check Character
Enable
Disable
Convert to EAN13
UPC-E Convert
Disable
Convert to UPC-A
14
Group 7-4: UPC-E
Save
Truncate Leading Digit
Truncate the system character
Truncate the first zero
Disable
Truncate Leading zero
15
Save
Group 7-5: ADD-ON 2/5
5 bit
2 and 5 bit
ADD-ON BIT
Disable
2 bit
16
Group 8: Codabar
Enable
Disable
Save
Verify Checksum
Disable
Enable
Transmit Check Character
Enable
Disable
17
Group 8: Codabar
Save
Transmit Start/End Type
ABCD/ABCD
Disable
abcd/abcd
ABCD/TN*E
abcd/tn*e
18
Group 9: Code128
Enable
Disable
Save
Truncate Leading Digit
Truncate the system character
Truncate the first zero
Disable
Truncate Leading zero
19
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45

Alfa Network BC-29 Installation & Programming Manual

Type
Installation & Programming Manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI