SUNCO LED23WT5PLL Operating instructions

Type
Operating instructions

SUNCO LED23WT5PLL is a direct wire LED lamp designed to replace traditional fluorescent lamps in existing luminaires. It features a PLL (plug-and-play) design for easy installation, eliminating the need for a separate LED driver. With a power consumption of 23 watts, it provides a bright and energy-efficient light output. The lamp operates on a wide voltage range of 120-277 volts AC, making it suitable for various applications. Additionally, it boasts a long lifespan, reducing the need for frequent replacements.

SUNCO LED23WT5PLL is a direct wire LED lamp designed to replace traditional fluorescent lamps in existing luminaires. It features a PLL (plug-and-play) design for easy installation, eliminating the need for a separate LED driver. With a power consumption of 23 watts, it provides a bright and energy-efficient light output. The lamp operates on a wide voltage range of 120-277 volts AC, making it suitable for various applications. Additionally, it boasts a long lifespan, reducing the need for frequent replacements.

LED 23W PLL LAMPS • DIRECT WIRE
INSTALL INSTRUCTIONS
PLEASE FIND A QUALIFIED ELECTRICIAN FOR INSTALLATION. Please read the instructions before you install and use the luminaire.
GENERAL: ALL ELECTRICAL CONNECTIONS MUST BE IN ACCORDANCE WITH LOCAL AND NATIONAL ELECTRICAL CODE (N.E.C.) STANDARDS. IF YOU ARE
UNFAMILIAR WITH PROPER ELECTRICAL WIRING CONNECTIONS OBTAIN THE SERVICES OF A QUALIFIED ELECTRICIAN. REMOVE THE TRIM FROM THE BOX
AND MAKE SURE THAT NO PARTS ARE MISSING.
RISK OF SHOCK: DISCONNECT POWER BEFORE INSTALLATION
• WARNING - Risk of fire or electric shock. - Retrofit kit installation requires knowledge of electrical systems. If not qualified, do not attempt
installation. Contact a qualified electrician.
• WARNING - Risk of fire or electric shock. - Install this kit only in the luminaires that have the construction features and dimensions shown in the
photographs and/or drawings and where the input rating of the retrofit kit does not exceed the input rating of the luminaire.
To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects.
Installers should not disconnect existing wires from the lampholder terminals to make new connections at lampholder terminals. Instead installers
should cut existing lampholder leads away from the lampholder and make new electrical connections to lampholder lead wires by employing
application connectors.
THIS RETROFIT IS ACCEPTED AS A COMPONENT OF A LUMINAIRE WHERE THE SUITABILITY OF THE COMBINATION SHALL BE DETERMINED BY
AUTHORITIES HAVING JURISDICTION.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
The units covered in this report were intended to retrofit surface mount, Type IC or Non-IC recessed mount listed fluorescent luminaires that use a
maximum of two lamps. The minimum dimensions of lamp compartment of luminaries are tabulated below.
TYPE B LAMP – intended for operation in luminaires with traditional fluorescent-type lampholders wired directly to the branch circuit. This includes
both factory-wired luminaries as well as those converted for this purpose under a retrofit program.
Only use the control provided with or specified by these instructions to control this lamp. This lamp will not operate properly when connected to a
standard (incandescent) dimmer or dimming control. Dimmable only when used with special 0-10V system interface component, ETA Q1.
IMPORTANT SAFETY INSTRUCTIONS
Product should be installed by a qualified electrician.
Do not use LED driver with the product.
The end retrofit luminaire has been modified and can no longer operate the originally intended lamp.
Caution - Risk of Electric Shock - Use in Dry and Damp Locations Only.
Not for use with totally enclosed fixtures.
Risk of Electric shock - Do Not Use Where Directly Exposed To Water.
This device is not intended for use with emergency exit fixtures or emergency exit lights.
ITEM# BASE MINIMUM LAMP COMPARTMENT DIMENSIONS LAMP QTY
07219
2G11 24”(L) x 23.6”(W) x 3.1”(H) 2
17219
27219
LED 23W PLL LAMPS • DIRECT WIRE
INSTALL INSTRUCTIONS
RETROFIT LUMINAIRE WITH ONE LAMP
!WARNING - Disconnect power or circuit breaker before installing or servicing.
AC 120-277V LED PLL LAMP
L
N
RETROFIT LUMINAIRE WITH TWO LAMPS
LED PLL LAMP LED PLL LAMP
AC 120-277V
L
N
PLL LAMP
LINE BLACK
WHITE
GREEN
BLUE
YELLOW
RED
ELECTRONIC
BALLAST
PLL LAMP PLL LAMP
LINE BLACK
WHITE
GREEN
BLUE
YELLOW
RED
ELECTRONIC
BALLAST
RETROFIT LUMINAIRE WITH THREE LAMPS
LED PLL LAMP LED PLL LAMP LED PLL LAMP
AC 120-277V
L
N
PLL LAMP
PLL LAMP
PLL LAMP
LINE BLACK
WHITE
GREEN
BLUE
YELLOW
RED
ELECTRONIC
BALLAST
LINE
BLACK
WHITE
GREEN
BLUE
YELLOW
RED
ELECTRONIC
BALLAST
Specifications subject to change without notice. Photos and line
drawings may not be to scale and are for general reference only.
  • Page 1 1
  • Page 2 2

SUNCO LED23WT5PLL Operating instructions

Type
Operating instructions

SUNCO LED23WT5PLL is a direct wire LED lamp designed to replace traditional fluorescent lamps in existing luminaires. It features a PLL (plug-and-play) design for easy installation, eliminating the need for a separate LED driver. With a power consumption of 23 watts, it provides a bright and energy-efficient light output. The lamp operates on a wide voltage range of 120-277 volts AC, making it suitable for various applications. Additionally, it boasts a long lifespan, reducing the need for frequent replacements.