GMI OXYGAS 500 TRAINING User manual

Category
Measuring, testing & control
Type
User manual

GMI OXYGAS 500 TRAINING is a robust and certified gas measurement instrument designed for measuring oxygen and flammable gases in various applications. It features a range of capabilities to meet your gas detection needs:

  • Multi-gas Detection: Measures oxygen (0-25%) and flammable gases (0-100% LEL).

  • Audible and Visual Alarms: Alerts you to hazardous gas levels with clear alarms.

  • Versatile Display: Provides digital and analog readings for easy interpretation.

  • Auto Zeroing: Ensures accurate readings by automatically adjusting the zero point.

  • Sample Flow Monitoring: Indicates proper gas flow and warns of potential blockages.

GMI OXYGAS 500 TRAINING is a robust and certified gas measurement instrument designed for measuring oxygen and flammable gases in various applications. It features a range of capabilities to meet your gas detection needs:

  • Multi-gas Detection: Measures oxygen (0-25%) and flammable gases (0-100% LEL).

  • Audible and Visual Alarms: Alerts you to hazardous gas levels with clear alarms.

  • Versatile Display: Provides digital and analog readings for easy interpretation.

  • Auto Zeroing: Ensures accurate readings by automatically adjusting the zero point.

  • Sample Flow Monitoring: Indicates proper gas flow and warns of potential blockages.

Gas Measurement Instruments Ltd
OXYGAS 500 TRAINING
Gas Measurement Instruments Ltd
OXYGAS 500
Objectives
EXPLAIN THE FUNCTIONS OF THE INSTRUMENTS
HOW TO OPERATE
Gas Measurement Instruments Ltd
OXYGAS 500
ROBUSTNESS
PROTECTION
CERTIFIED
DISPLAY
PUMP
AUDIBLE / VISUAL ALARMS
SEALED RUBBERISED SWITCHES
INFRA RED COMMS POINT
Gas Measurement Instruments Ltd
OXYGAS 500
Certification
ATEX
»EEx iad IIC T4 II 2 G
UNDERWRITERS LABORATORIES INC (UL)
»Class 1 Groups A B C D
AUTHORISATION
BATTERY COMPARTMENT
Gas Measurement Instruments Ltd
Ranges of Operation
0 - 100% LEL
0-100% Volume Gas
0-25% Oxygen
Flammable Auto-ranging
OXYGAS 500
Gas Measurement Instruments Ltd
Display - Flammable
CURRENT RANGE DISPLAYED
DIGITAL
»RESOLUTION
0 - 10 % LEL - STEPS OF 0.1%
10 - 100% LEL - STEPS OF 1%
0 - 10% GAS - STEPS OF 0.5%
10 - 100% GAS - STEPS OF 1%
ANALOGUE
»RESOLUTION
STEPS OF 4%
Range Indicator
OXYGAS 500
Bargraph
Gas Measurement Instruments Ltd
Display - Oxygen
CURRENT RANGE DISPLAYED
DIGITAL
»RESOLUTION
0-21% insteps of 0.1% O2
21-25% in steps of 1% O2
ANALOGUE
»RESOLUTION
STEPS OF 4%
OXYGAS 500
Range Indicator
Gas Measurement Instruments Ltd
Zeroing
AUTO ZERO
OPERATOR MESSAGES
»CHECK ZERO FLAG
»ZERO FAULT FLAG Operator Messages
OXYGAS 500
Gas Measurement Instruments Ltd
Sampling
PUMP
0.5 - 0.7 L PER MIN
SAMPLE FLAG
AUTO SWITCH OFF
»Display Message
Gas Flow Direction
Gas Outlet Gas Inlet
OXYGAS 500
Gas Measurement Instruments Ltd
Accessories
Carry Case
Filters
Sample Line
Sample Line Adaptor
Probe
Probe Handle Assembly
Shoulder Harness
Hex Driver
Handbook
OXYGAS 500
Gas Measurement Instruments Ltd
Cotton and Hydrophobic Filters
within Probe Handle Assembly
Probes / Probe Handle
Assembly
Range of Probes Available
OXYGAS 500
Gas Measurement Instruments Ltd
Batteries
Rechargeable (NiCd)
»approx. 9 hours runtime
»battery life displayed at power on
»‘BAT’ flag approx. 30mins before switch off
Alkaline
»approx. 15 hours runtime
»battery life displayed at power on
»‘BAT’ flag approx. 60mins operating time remaining
Battery
Warning
Flag
Battery life display
OXYGAS 500
Gas Measurement Instruments Ltd
Rechargeable Battery Pack
Standard Charger
»14 hours to charge a flat battery
Flatbed Charger
»14 hours to charge a flat battery
Smart Charger
»60mins to 90% recharged, 120mins to fully recharged
»2 batteries simultaneously
»Discharge and charge cycle
OXYGAS 500
Gas Measurement Instruments Ltd
Before Use Checks
Casing
Display
Filters
Sample Line
Battery Pack
Calibration Label
OXYGAS 500
Gas Measurement Instruments Ltd
Operation
OXYGAS 500
Gas Measurement Instruments Ltd
Operation
Top Button
»Press and Hold - Switches ON in
Measure Mode
»Double Press - Switches OFF
»Single Press - Toggles Pump On
/ Off
OXYGAS 500
Gas Measurement Instruments Ltd
Operation
Bottom Button
»Press and Hold - Switches ON in
Purge Mode
»Changes range
(Alternate Flash)
Display in Purge Mode
OXYGAS 500
Gas Measurement Instruments Ltd
Warm Up
ALL SEGMENTS
ID & SOFTWARE VERSION
BATTERY STATUS
CALIBRATION DATE
INSTRUMENT SAMPLING
OXYGAS 500
Gas Measurement Instruments Ltd
Operator Messages
Pump is running and instrument
sampling
Batteries will soon require
replacing
Instrument about to switch off
Possibility of zero shift
OXYGAS 500
Gas Measurement Instruments Ltd
Fault Messages
Zero is outwith its calibration limit
Problem with the instrument’s
sample flow
Batteries require replacing
Calibration error detected
OXYGAS 500
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26

GMI OXYGAS 500 TRAINING User manual

Category
Measuring, testing & control
Type
User manual

GMI OXYGAS 500 TRAINING is a robust and certified gas measurement instrument designed for measuring oxygen and flammable gases in various applications. It features a range of capabilities to meet your gas detection needs:

  • Multi-gas Detection: Measures oxygen (0-25%) and flammable gases (0-100% LEL).

  • Audible and Visual Alarms: Alerts you to hazardous gas levels with clear alarms.

  • Versatile Display: Provides digital and analog readings for easy interpretation.

  • Auto Zeroing: Ensures accurate readings by automatically adjusting the zero point.

  • Sample Flow Monitoring: Indicates proper gas flow and warns of potential blockages.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI