  • Hello! I am an AI chatbot trained to assist you with the International Controls & Measure ACH060 Installation guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
SC
060,
SC
065,
SC
070
2-WIRE THERMOSTATS
SPECIFICATIONS
•OperatingVoltage: 18-30 VAC
•MaximumCurrent: 2.0 Amps
NON HEAT PUMP – INSTALLATION INSTRUCTIONS
1. Verify power is OFF to heater controls.
2. Wire nut one black wire of thermostat to 24 VAC (red) wire.
3. Wire nut the second black wire of the thermostat to the heating device (white)
wire and the fan (green) wire in Electric heat applications.
4. Verify wiring is correct and then apply power.
5. Verify system functions correctly.
* Fan (green) wire must be connected to heat system (white) wire for electric
heat applications.
1. Verify power is OFF to heater controls.
2. Wire nut one black wire of thermostat to 24 VAC (red) wire and the reversing valve
(blue) wire if it is heat active.
3. Wire nut the second black wire of the thermostat to the compressor (yellow) wire
and the fan (green) wire.
4. Verify wiring is correct and then apply power.
5. Verify system functions correctly.
HEAT PUMP – INSTALLATION INSTRUCTIONS
LII319
www.icmcontrols.com
800-365-5525