Zeiss Victory FL Operating instructions

Type
Operating instructions
Carl Zeiss Sports Optics
Gebrauchshinweise
Instructions for use
Mode d’emploi
Istruzioni d’impiego
Modo de empleo
Bruksanvisning
Informacje dotyczące użytkowania
Инструкция по применению
Használati utasítás
ZEISS VICTORY 32 T* FL
ZEISS. PIONIER SEIT 1846.
1375-600 / 03.2014
ZEISS VICTORY
®
“This product may be covered by one or more of the following
United States patents: US6542302, US6816310, US6906862”
www.zeiss.de/sports-optics
Carl Zeiss
Sports Optics GmbH
Carl Zeiss Group
Gloelstrasse 3 – 5
35576 Wetzlar
32 T* FL / 42 T* FL / 56 T* FL
4 5
INSTRUCTIONS FOR USE
Congratulations on your outstanding new binoculars. Enjoy the impressive experience of
undistorted image reproduction which is distinguished by perfect brilliance and excellent
colour accuracy.
ZEISS brand products are characterised by outstanding optical performance, accurate
processing and long durability.
Please observe the following instructions for use, so that you enjoy optimum use of your
product and it can be a faithful companion to you for many years.
Viewing with and without glasses
If you do not wear glasses when viewing, use the binoculars with the eyecups extended (Fig.
1/A). To do this, turn the eyecups upwards to the top click stop position by turning them to the
left (counter clockwise). The eyecups can be set to four click stop positions – the positions at
the top and bottom and two intermediate positions (Fig. 2). These adjustment options permit
the distance from the exit pupil to be varied according to the specific requirements of each user.
If you wear glasses when viewing, turn the eyecups to the right (clockwise) to the lowest click
stop position as shown in Fig. 1/B.
Cleaning and changing the eyecups
The eyecups (complete modules) can be removed from the binoculars for cleaning or exchange.
Turn out the eyecup counter clockwise to the stop, then unscrew it completely via the thread
(continue to turn in the same direction). After cleaning or exchange, turn the eyecup clockwise to
the lowest click stop position. Then attach the module to the binoculars, through the rubber edge
of the eyepiece tube, turn it in clockwise as far as it will go and tighten it.
Adjustment of the interpupillary distance
Adjust the two barrels relative to each other about the central axis until you see one circular field
of view when viewing with both eyes.
Focusing
The binoculars have a centre focusing mechanism (focusing knob Fig. 3/C) and a dioptre
adjustment wheel. Dioptre adjustment is activated by pulling the focusing knob (Fig. 3/C)
upward.
For focusing, close your right eye and focus the image in the left barrel using the centre
focusing mechanism (Fig. 3/C). Then close your left eye – and if necessary – adjust the focus
in the right barrel using the dioptre adjustment wheel.
The dioptre adjustment wheel is provided with a scale (visible when the focusing knob has been
pulled out, Fig. 3), the signs “+” and “–”, and a click stop in the zero position (0 D). The
graduation lines of the scale are used for orientation (setting the dioptre adjustment for different
users).
After completion of this procedure, push the focusing knob back in all the way.
Note: Always use the same object to focus on both images!
For subsequent focusing on varying distances, use the focusing knob only (Fig. 3/C). When the
long ridge of the focusing knob coincides with the arrow on the bridge (Fig. 3/D), the binoculars
have been set to infinity. This only applies if the dioptre adjustment mechanism has snapped in
at the zero position (0 D).
Mounting the carrying strap and the protective covers
The carrying strap, the rainguard and the protective caps for the objective lens are provided in the
packaging. Attach the carrying strap to the eyelets pro-vided on the binoculars and mount the
rainguard on the strap as shown in Figs 4 + 5.
Note: Simply thread the carrying strap through the eyelets on the rainguard.
Before mounting the carrying strap as shown in Fig. 5, adjust the length of the strap as required
by loosening or tightening it accordingly using the clip.
The rain guard needs only to be attached on one side; however, it can be attached to both sides.
Use of the eyepiece cap
The eyepiece cap is held on the eye cup with a snap latch.
Remove the eyepiece cap with your index fingers before using the binoculars.
The eyepiece cap should be reattached after using the binoculars to protect the eyepiece.
The protective caps for the objective lens are attached to the binoculars as shown in Fig. 6.
Mounting on a tripod
The binoculars of the ZEISS VICTORY FL series can be mounted on any commercial camera tripod
using the ZEISS universal tripod adapter for binoculars.
Cat. No.: ZEISS Alu tripod kit 1778-480
Cat. No.: ZEISS tripod adapter for binoculars 52 83 87
6 7
Care and maintenance
ZEISS binoculars need no special care or maintenance. Do not wipe off coarse dirt particles (e.g.
sand) from the lenses, but blow them off or remove them with a soft brush.
Fingerprints on the lens surfaces may affect them in the course of time. The easiest way to keep
the lenses clean is by breathing on them and wiping with a soft optical cleaning cloth or optical
cleaning paper. To avoid a possible fungal coating which is common in the tropics, store the
optics in a dry place and always ensure good aeration of the lens surface.
Warning:
Do not under any circumstances look through the binoculars at the sun or laser light sources!
Serious eye injury may otherwise result.
Accessories for ZEISS VICTORY binoculars T* FL
1
Alu tripod kit
incl. Video head an carrying strap
1778-480
Binofix Tripod fixture
suitable for all binocular models
52 83 87
Air Cell carrying strap, air cushioned
for ultra-high carrying comfort.
Attaches quickly with quick release mechanisms.
52 91 13
Attachment for magnification 3x12 Mono
for 3 times extra power
52 20 12
Adapter for ZEISS VICTORY 32 T* FL /
42 T* FL / 56 T* FL
52 83 77
1
Accessories are not included in delivery!
Subject to changes in design and scope of delivery as a result of ongoing technical development.
Technical data
ZEISS VICTORY
8x32 T* FL
ZEISS VICTORY
10x32 T* FL
ZEISS VICTORY
7x42 T* FL
ZEISS VICTORY
8x42 T* FL
ZEISS VICTORY
10x42 T* FL
ZEISS VICTORY
8x56 T* FL
ZEISS VICTORY
10x56 T* FL
Magnification 8x 10x 7x 8x 10x 8x 10x
Objective lens diameter (mm) 32 32 42 42 42 56 56
Field of view at 1000 m (m) 140 WW 120 WW 150 WW 135 WW 110 WW 130 WW 110 WW
Exit pupil (mm) 4 3.2 6 5.25 4.2 7 5.6
Shortest focusing distance (m) 2 2 2 2 2 3 3
Dioptre adjustment range ≥ +/– 4 dpt +/– 4 dpt +/– 4 dpt +/– 4 dpt +/– 4 dpt +/– 4 dpt +/– 4 dpt
PD from/to (mm) 52 – 74 52 – 74 54 – 76 54 – 76 54 – 76 55 – 76 55 – 76
Height with retracted
eyecup (mm)
117 117 152 161 161 188 188
Width with PD of 65 mm (mm) 116 116 128 128 128 145 145
Maximum width (mm) 129 129 138 138 138 158 158
Weight (g) 560 560 740 755 765 1220 1250
Waterproof in acc. with
DIN ISO 9022-8
Nitrogen filling
Subject to changes in design and scope of delivery as a result of ongoing technical development.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21

Zeiss Victory FL Operating instructions

Type
Operating instructions

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI