www.pulsar.pl INTE
5
4. Configuration of the Ethernet interface.
4.1 Factory settings of the interface.
Login page:
Username - root
Password - dbps
IP address
Acquired automatically from the DHCP database of the
router
Network’s name (SSID)
No name
Network security
No preset protections
Communication parameters of a serial port
No configuration
4.2 Preliminary information.
Parameters of the Ethernet interface can be configurable in order to adjust them to the real operation
mode. The configuration is via search engine after correct logging, i.e. typing correct username and password.
The ‘Digi Device Discovery’ program is also helpful as it allows previewing important parameters of the
interface at the preliminary stage of the configuration. The application seeks out modules available at the router’s
range and informs about the assigned IP address and MAC unique address.
Download the ‘Digi Device Discovery’ program from the following page:
http://www.pulsar.pl/pl/pliki/digi_discovery.exe
A newly purchased Ethernet interface is delivered with basic configuration (factory settings) which is not
adjusted to correct operation in the system. As the communication with the interface is via radio waves, it is
important to adjust your router accordingly so that it can establish connection with the interface. The most
convenient solution is to own a separate router or to restore the factory settings of the one in use (if possible).
The information included in the following subsections will show ‘step by step’ how to configure the router
and the Ethernet interface granted that both devices are set to factory settings (settings after a reset).
In this manual, the configuration of the Ethernet interfaces has been based on a ‘LinkSys WRT54GL’
router.
4.3 STEP 1 – Restoring the factory settings.
Router:
To restore the factory settings of the router, check the device’s manual and perform actions following the
manufacturer’s instructions. In most cases, the actions narrow down to finding the reset button at the back of the
enclosure and holding it for approx. 5s. After releasing the button, wait approx. 1 min for the correct initiation of the
router. The initiation restores the factory settings to:
Address: 192.168.1.1
Username: admin
Password: admin
Ethernet interface:
To restore the factory settings of the interface, press and hold the INIT button and then press and release
the RESET button one time. Still holding the INIT button, wait approx. 20s during which the interface will be
twinkling: 3 times with the yellow LED [8 – fig. 1] and then 5 more times. Correctly performed initiation restores the
interface’s settings, among others, to:
Address: assigned automatically by the router
Username: root
Password: dbps
After restoring the factory settings of the router and the interface, the yellow LED of the interface is
illuminated and the green one twinkles indicating active connection. If not, it may be necessary to disconnect the
module from the power supply and then switch it back on. If these actions prove insufficient, begin the procedure of