GF GFCP Calibration Tool Owner's manual

Type
Owner's manual
GEORG FISCHER
CENTRAL PLASTICS
GEORG FISCHER
PIPING SYSTEMS
CALIBRATION TOOL
Instruction Manual
Part Number: 360060660
Manual Part Number: 360091924
2
1. Verify the calibration tool reads 0 psi with no load. If gauge shows any
pressure, the tool will need to be services.
2. New Top Load Clamp - find a suitable flat,
stable surface to place the calibration tool
on where the strap can be positioned for
security (such as a shop vice). Ensure knob is
fully retracted before tightening strap.
Older Top Load Clamp - center calibration
tool on base plate and lower top bar and
holder onto calibration tool. Ensure knob is
fully retracted.
3
3. Tighten Top Load Clamp until indicator is flush with top of knob. If gauge reads 200 psi (+/- 20 psi),
test is complete.
4. If gauge is out of range, follow these steps:
A. Break the jam nut loose and slightly retighten.
B. Turn knob until 200 psi is reached.
C. Loosen jam nut.
D. Adjust knob so pin is flush.
E. Slightly tighten jam nut.
F. Loosen knob and then return to 200 psi.
G. Make sure pin is still flush.
H. Tighten jam nut completely.
GEORG FISCHER
CENTRAL PLASTICS
GEORG FISCHER
PIPING SYSTEMS
For more information, please contact:
GF CENTRAL PLASTICS
39605 Independence, Shawnee, OK 74804
(800) 654-3872
GFCentralMarketing@georgfischer.com
www.gfcp.com / www.gfpiping.com
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

GF GFCP Calibration Tool Owner's manual

Type
Owner's manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI