WURM W-LINK-CAN Product information

Type
Product information

WURM W-LINK-CAN

The WURM W-LINK-CAN is a receiver unit for wireless product temperature sensors. It can document and monitor temperatures from up to 8 wireless sensors and provides them to other devices via the CAN bus.

The W-LINK-CAN has an internal alarm for up to 8 wireless sensors and can be installed on a wall or ceiling. It has a 3-wire CAN bus interface and is powered by a 230V power supply.

The W-LINK-CAN is easy to install and use. Simply mount it on a wall or ceiling, connect it to the CAN bus, and power it on. The W-LINK-CAN will automatically start receiving and monitoring temperatures from wireless sensors.

WURM W-LINK-CAN

The WURM W-LINK-CAN is a receiver unit for wireless product temperature sensors. It can document and monitor temperatures from up to 8 wireless sensors and provides them to other devices via the CAN bus.

The W-LINK-CAN has an internal alarm for up to 8 wireless sensors and can be installed on a wall or ceiling. It has a 3-wire CAN bus interface and is powered by a 230V power supply.

The W-LINK-CAN is easy to install and use. Simply mount it on a wall or ceiling, connect it to the CAN bus, and power it on. The W-LINK-CAN will automatically start receiving and monitoring temperatures from wireless sensors.

W-LINK-CAN
Product information
W-LINK-CAN_V2.0.0_PI_2020-08_EN Subject to technical changes Page 1 of 4
1 Front view
Receiver unit for W-LINKpro wireless product temperature sensors
2 Features
Internal documentation and alarm for up to 8 wireless sensors
Housing for wall or ceiling installation
Connection to the Wurm system via communication bus (CAN bus) and FRIGODATA XP
NOTICE
You can find information about the W-LINK system and parameter settings for
the receiver unit in the W-LINK system manual.
W-LINK-CAN
Product information
Page 2 of 4 Subject to technical changes W-LINK-CAN_V2.0.0_PI_2020-08_EN
Writing conventions
Symbol
Meaning
CAUTION
Avoid the described hazard: otherwise minor or medium physical injury or damage
to property will result.
WARNING
Avoid the described hazard: otherwise there is danger from electric voltage that
could cause death or serious physical injury.
For your safety
For safe operation and to avoid personal injury and equipment damage through operator error, always
read these instructions, become familiar with the device, and follow all safety instructions on the
product and in this document, as well as the safety guidelines of Wurm GmbH & Co. KG Elektronische
Systeme. Keep these instructions ready to hand for quick reference and pass them on with the device
if the product is sold.
Wurm GmbH & Co. KG Elektronische Systeme accepts no liability in the case of improper use or use
for purposes other than the intended purpose.
Target group
This manual is intended for "service technicians".
Intended use
The W-LINK-CAN receiver unit receives temperatures from W-LINKpro
wireless product temperature sensors for documenting and monitoring
and provides them to other devices via the CAN bus.
WARNING
DANGER TO LIFE FROM ELECTRIC SHOCK AND/OR FIRE!
Switch off the power to the entire plant when carrying out installation, wiring or
removal work. Otherwise, mains voltage and/or external voltage may still be
present, even if the control voltage is switched off.
The wiring of the device must be carried out only by qualified electricians.
Use only the correct tools for all work.
Check all wiring after connection.
Take note of the maximum loads on all connections.
Never expose the device to moisture, for example due to condensation or
cleaning agents.
Take the device out of operation if it is faulty or damaged and is therefore
compromising safe operation.
Do not repair the device yourself. If the device requires repairs, send it in with
an exact description of the fault.
CAUTION
ELECTROMAGNETIC INTERFERENCE CAN CAUSE FAULTS!
Always use shielded data cables and place them far away from power lines.
Version and validity of the documentation
Date
2020-08
Documentation status
Any versions not listed are special solutions for individual projects and are not described in detail in this document. This
document automatically ceases to be valid if a new technical description is issued.
Manufacturer: Wurm GmbH & Co. KG Elektronische Systeme, Morsbachtalstraße 30, D-42857 Remscheid
For further information, see our website at www.wurm.de
W-LINK-CAN
Product information
W-LINK-CAN_V2.0.0_PI_2020-08_EN Subject to technical changes Page 3 of 4
3 Installation
Fig. 1 Wall or ceiling installation, drilling dimensions in mm
Wall or ceiling installation
1. Insert a flat screwdriver into the opening
slit (A) and open both housing panels
(B).
2. Refer to the drilling dimensions of the
four installation holes (C) and install the
housing on the wall or ceiling.
Access to connections, coding
switch and LEDs
1. Loosen the four screws (D).
2. Open the housing.
( Chapter 4 "Connections" on page 4)
Fig. 2 Wall installation
Fig. 3 Ceiling installation
Adjusting the antenna
In order to receive a uniform signal, always
place the antenna rod vertically.
For wall installation: place the antenna
rod vertically. ( Fig. 2)
For ceiling installation: fold the antenna
rod vertically. ( Fig. 3)
Fig. 4 Setting up the receiver and transmitter
Setting up the receiver and
transmitter
The range of radio waves in the wall area
and in the vicinity of existing objects is
influenced by disruptive scattering or
reflection. To avoid this, install the receiver
and transmitter as follows:
Do not install on the same wall side in
order to avoid radio propagation along a
wall surface
Install on opposite or adjoining wall
surfaces ( Fig. 4)
Install the receiver with a distance of at
least 50cm to other transmitters and
high-frequency sources of interference
such as GSM, DECT, wireless LAN or
computer, audio and video systems
Tip: Improve reception by moving the
transmitter and receiver
NOTICE
Further installation instructions can be found in the W-LINK system manual.
W-LINK-CAN
Product information
Page 4 of 4 Subject to technical changes W-LINK-CAN_V2.0.0_PI_2020-08_EN
4 Connections
WARNING
DANGER TO LIFE FROM ELECTRIC SHOCK AND/OR FIRE!
The wiring of the device must be carried out only by qualified electricians.
NOTE
Open the housing to access the
connections, coding switches and LEDs.
(
Chapter 3 "Installation" on page 3)
No
.
Function
Description
1
CAN bus connection
2
CAN bus terminating resistor
3
Coding switch
1-7
CAN address: for determining the CAN address in binary coding. The
address is the sum of the weights of the switches set to "ON".
Example: to set address 40, slide switches 4 and 6 to ON. The sum of the
weights 8+32 is 40.
Coding switch
1
2
3
4
5
6
7
Weight at ON setting
1
2
4
8
16
32
64
8
Baud rate:
ON = 20kBit/s (fixed)
OFF= Automatic mode
4
Status LEDs
(from left to right)
1
Operating voltage and ready for use (flashes 1x per second)
2
No function
3
No function
4
No function
5
Receipt of a wireless telegram
6
CAN bus reception LED
7
CAN bus transmission LED
5
Mains power supply
230V
5 Technical data
Power supply
230V~, +10% / -15%, 3VA approx.
Display
Visible when housing open:
1 x LED, operating indicator
2 x LED, CAN bus data traffic
1 x LED, wireless reception
Communication
3-wire CAN bus interface
Dimensions
(WxHxD) 120 x 90 x 50mm
Fastening
Wall or ceiling installation
Ambient temperature
Operation: 0...+55°C, storage: -25…+70°C
Weight
About 350g
Reception antenna
Folds to positioning angles 0°, 45° and 90°
Technology
EnOcean, RCM
Transmission frequency
868.3MHz
Range
Building: approx. 30m, open area: approx. 300m
CE conformity
EU conformity as defined in
- 2014/53/EU (Radio Equipment Directive)
General approval for wireless operation applies for all EU countries and Switzerland.
RoHS II
Valid from
Version 2.0.0
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

WURM W-LINK-CAN Product information

Type
Product information

WURM W-LINK-CAN

The WURM W-LINK-CAN is a receiver unit for wireless product temperature sensors. It can document and monitor temperatures from up to 8 wireless sensors and provides them to other devices via the CAN bus.

The W-LINK-CAN has an internal alarm for up to 8 wireless sensors and can be installed on a wall or ceiling. It has a 3-wire CAN bus interface and is powered by a 230V power supply.

The W-LINK-CAN is easy to install and use. Simply mount it on a wall or ceiling, connect it to the CAN bus, and power it on. The W-LINK-CAN will automatically start receiving and monitoring temperatures from wireless sensors.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI