Zibro Kamin R 59 C, Kamin R 27 C, R 59C, R59C Owner's manual

  • Hello! I am an AI chatbot trained to assist you with the Zibro Kamin R 59 C Owner's manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Dear Sir, Madam,
Congratulations on your purchase of this Zibro Kamin heater, the number one
brand amongst portable heaters. You have purchased a quality product, which
will serve you for many years to come. This, of course, provided you use the
heater correctly. Please read these Directions for Use first, to ensure the
maximum lifetime for your heater.
This appliance comes with a 24-month manufacturer’s warranty on all defects
in materials or workmanship.
We wish you much warmth and comfort from your Zibro Kamin heater.
Yours sincerely,
PVG International b.v.
Customer Service Department
1 READ THE DIRECTIONS FOR USE FIRST.
2 IN CASE OF ANY DOUBT, CONTACT YOUR ZIBRO KAMIN DEALER.
3 BEFORE YOU START READING, FOLD OUT THE LAST PAGE.          
4
50
R 59 C
GENERAL DIRECTIONS FOR USE
Below you will find the main steps to be taken for
using your heater. For more details, please refer to
the MANUAL (pages 53 ff.).
The first time you ignite your heater it will smell
like ’new’ for a short time.
Store your fuel in a cool and dark place.
Fuel has a limited shelf life. Start every heating
season with new fuel.
The right quality of fuel will be assured, when
you use Zibro Plus for your heater.
If you change to another brand and/or type of
parrafin oil, you must first finish up all the
remaining fuel in the heater.
MAIN COMPONENTS
Safety button (for
emergency stop)
Flame regulator
Igniter slide
Combustion chamber
Combustion chamber
handle
Fuel indicator
Grill
Lid for removable
tank
Removable tank
Fuel gauge
removable tank
Wick height lock
Ignition coil
Battery holder
Door
                      
Remove all packaging materials (refer to Section A, Fig. A).
Fill the removable tank and wait 30 minutes before you
ignite the heater
(refer to Section B, Fig. I).
Insert the batteries into the battery holder
(refer to Section A, Fig. F).
Check whether the combustion chamber is fully upright
(refer to Section A, Fig. E).
Ignite the heater by pushing down the flame regulator and
the igniter slide
simultaneously (refer to Section C, Fig. K).
Prior adjusting the flame (refer to Section D), let the heater
heat up for 10 to 15 minutes
.
Switch off the heater (refer to Section E).
1
2
3
4
5
6
7
4
51
R 59 C
WHAT YOU NEED TO KNOW IN ADVANCE
ALWAYS MAKE SURE THAT THERE IS SUFFICIENT VENTILATION
For each model the minimum size of space is specified in which you can use the
heater safely, without additional ventilation
(refer to Section K). If a particular
room is smaller than the specified space, always leave a window or door slightly
ajar (± 2.5 cm). We also recommend doing this in highly insulated or draught-free
rooms and/or at altitudes above 1,500 metres. However, if there is insufficient
ventilation (i.e. oxygen), the heater will automatically switch off. Do not use your
heater in cellars or other underground areas.
SAFE TOP
The heater is supplied with a safe top. This application decreases the temperature
of the top plate. In this way, the risk of harmful accidents at accidentally touching
the top plate is considerably decreased. However, be aware that the top plate still
becomes hot.
Avoid any contact with the top plate and grille.
THE RIGHT FUEL
Only use Class C1 paraffin fuel in accordance with BS2869 Part two, or equivalent.
Your Zibro Kamin heater has been designed for use with high-quality water-free
pure paraffin oil, such as Zibro Plus. Only fuels of this kind will ensure clean and
proper burning. Lower quality fuel may result in:
excessive tar deposits on the glass fibre wick
incomplete burning
reduced heater lifetime
smoke and/or smells
deposits on the grid or mantle
Using the right fuel is therefore essential for safe, efficient, and comfortable use
of your heater.
Always refer to your local Zibro Kamin dealer for the right fuel for your heater.
4
52
R 59 C
A
The fuel cap cover can
be found at the rear of
the heater. This cover
allows you to keep your
hands clean when
opening the fuel tank.
This transportation cap
is packed separately in
the box. Only this cap
ensures trouble-free
transportation of the
heater after use.
Store it well!
Only the use of the
correct fuel will ensure
safe, efficient, and
comfortable use of your
heater.
MANUAL
A INSTALLING THE HEATER
Carefully remove your Zibro Kamin heater from the box and check the
contents. In addition to the heater you also need to have:
the batteries
a manual fuel pump
a transportation cap
a fuel cap cover
these directions for use
Keep the box and the packaging materials (Fig. A) for storage and/or transportation.
Remove the other packaging materials:
Remove the packaging material from the grill . Lift the grill from the slot
(Fig. B) and pull it forward.
Push the packing material on top of the combustion chamber slightly
down and remove it (Fig. C). Remove the packaging materials from under
the combustion chamber as well (Fig. D).
Put the combustion chamber back into its place. The combustion chamber
is positioned correctly when it can be smoothly moved a little to the left
and to the right by its handle
(Fig. E). Close the grill: Slightly lift it to
reposition it in its slot.
Open the lid of the removable tank and remove the piece of cardboard.
Fill the removable tank as indicated in
Section B.
Insert the batteries into their holder at the back of the heater (Fig. F).
Ensure that the positive and negative poles match the + and - marks indicated
on the battery housing.
The floor should be firm and completely level. Reposition the heater, when it is
not level. Do not correct the situation by placing books or goods under the
heater.
Please refer to the separate instruction in the carton box for fixing of
the heater.
Your Zibro Kamin heater is now ready for use.
B FILLING FUEL
Do not fill the removable tank in the living room, but in a more suitable place
(there can always be some spillage). Follow the procedure below:
Make sure that the heater is switched off.
Open the lid
and lift the removable tank out of the heater (Fig. G).
Note: Some drops may leak from the tank. Put down the removable tank
(cap pointing upwards) and screw off the fuel cap using the fuel cap cover (Fig. H).
2
1
6
5
4
3
2
1
4
53
R 59 C
     
B
C
D
E
F
H
G
Take the manual fuel pump and insert the smooth, most rigid tube into the
jerrycan. Make sure that it is in a higher position than the removable tank
(Fig. I). Insert the ribbed hose into the opening of the removable tank.
Lock the valve on top of the pump (turn clockwise).
Squeeze the pump a few times, until fuel starts flowing into the removable
tank. As soon as this happens, there is no need to press any longer.
Check the removable tank fuel gauge
while filling the tank (Fig. J). Stop
filling by loosening the valve on top of the pump (turn anti-clock-wise), once
the gauge indicates that the tank is full. Never overfill the tank, especially not
when the fuel is very cold (fuel expands when it heats up).
Let the remaining fuel in the pump flow back into the jerrycan and carefully
remove the pump. Carefully screw the fuel cap back on the tank using the
fuel cap cover (Fig. H). Clean off any spilled fuel.
Check whether the fuel cap is straight and tightened properly. Reinstall the
removable tank in the heater (cap down). Close the lid.
C IGNITING THE HEATER
A new heater may give off some smells for a short while, when it is used for the
first time. You should therefore provide extra ventilation or ignite the heater
outside the living room.
When you use the heater for the first time, first put the filled removable tank into
place, and then wait approximately 30 minutes before you ignite the heater. This
allows the glass fibre wick to soak up the fuel. Follow the same procedure when you
have completely burnt up all fuel from the tank, and after the glass fibre wick has
been replaced.
Prior to igniting the heater, always check the fuel indicator
for sufficient fuel in
the removable tank. Green = full, red = empty.
Always ignite the heater with the igniter slide. Never use matches or cigarette lighters.
Follow the procedure below:
Open the door
at the front of the heater.
Slowly push down the igniter slide
together with the flame regulator
(Fig. K). At the same time you will activate the safety device.
Release the ignition slide as soon as a flame is visible at the bottom of the
combustion chamber
.
Close the door.
4
3
2
1
8
7
6
5
4
3
4
54
R 59 C
K
J
I
empty full
After having ignited the heater, always check whether the combustion
chamber
is level, by sliding it slightly to the left and the right by its handle
. This should be a smooth movement. If the combustion chamber is not level,
this will cause smoke and soot to develop.
D ADJUSTING THE FLAME
After you have ignited the heater, it will take 10 to 15 minutes for the flame to
become visible in the upper end of the combustion chamber. Only then can you
check whether the flame is correct. Too high a flame may cause smoke and soot,
whereas too low a flame causes smells. The page opposite the folding page shows
the minimum and maximum permissible burning heights of the flame (Fig. Q).
The flame can be adjusted continuously with the flame regulator
(Fig. L).
If the flame remains low after the adjustment, the wick height must be
adjusted
(refer to Section F).
Too low a flame may also be caused by:
insufficient fuel (fill the tank)
poor fuel quality (contact your dealer)
insufficient ventilation (leave window or door ajar)
wastage of the wick (contact your dealer or replace the wick,
refer to section M)
E SWITCHING OFF THE HEATER
Let the heater burn at its lowest setting for approximately one minute. Then
slowly slide up the flame regulator
. The flame will extinguish by itself.
In cases of emergency: switch off the heater with the safety device
(Fig. M).
F ADJUSTING THE WICK HEIGHT
After some time the flame may no longer be high enough (Section D). In that case
you can adjust the wick height to improve the flame. To do this, follow the next
procedure:
Open the door
at the front of the heater.
Slide up the wick height lock
one step to position 2 or 3 (Fig. N).
If this does not have the required effect, let the heater burn until all fuel is used
(Section H).
If the flame still remains too low after that and the wick is already set to
position 3, contact your Zibro Kamin dealer, or replace the wick
(Section M).
If the flame rises too high after the adjustment (Fig. Q), lower the wick height lock
setting one position. Otherwise there is a chance of smoke and soot production.
2
1
4
55
R 59 C
L
M
E
N
G MALFUNCTION, CAUSES AND SOLUTIONS
If any malfunctioning cannot be solved from the directions below, please contact
your Zibro Kamin dealer.
THE HEATER DOES NOT IGNITE
The batteries are not positioned correctly in the holder. Check (Fig. F).
There is not enough power left in the batteries for the ignition. Replace (Fig. F).
You have run out of fuel from the tank or the wick has been replaced.
After having refilled and replaced the removable tank, wait for 30 minutes
before igniting the heater.
You are pushing down the igniter slide with too much force.
Push it down less forcefully (Section C).
The ignition coil is defective.
Contact your dealer.
IRREGULAR FLAME AND/OR SOOT AND/OR SMELLS
The combustion chamber has not been positioned correctly.
Use the handle to put it level, until you can easily slide it slightly to the left
and to the right and the chamber is level.
The flame height has not been adjusted properly.
See Fig. Q and the directions in Section D.
You are using fuel which is past its ‘use by’ date.
Start every heating season with fresh fuel.
You are using the incorrect type of fuel.
Refer to THE RIGHT FUEL (Section ’What you need to know in advance’).
Dust has gathered in the lower part of the heater.
Contact your dealer.
The wick heigt has not been adjusted correctly
Refer to Section F.
THE HEATER SLOWLY EXTINGUISHES
The removable tank is empty.
Refer to Section B.
The fuel filter is contaminated by water.
Dry the fuel filter (Section H, Fig. O).
The lower reservoir is contaminated by water.
Contact your dealer.
The wick has hardened on the upper side.
Burn the heater until all fuel is used (Section H). Use the right fuel.
You are using fuel which is past its ‘use by’ date.
Start every heating season with fresh fuel.
THE HEATER REMAINS BURNING LOW
Wick position too low.
Move the wick height lock one position (Section F).
Before you refilled the tank, the heater had burnt up almost all the fuel.
After having refilled and replaced the removable tank, wait for 30 minutes
before igniting the heater.
You are using the incorrect type of fuel.
Refer to THE RIGHT FUEL (Section ’What you need to know in advance’).
The room is insufficiently ventilated.
Leave a window or a door wide open for a while.
4
56
R 59 C
F
broken ignition coil
THE HEATER BURNS TOO HIGH, THE FLAMES CANNOT BE ADJUSTED.
You are using an incorrect, too volatile type of fuel.
Refer to THE RIGHT FUEL (Section ’What you need to know in advance’).
Wick position too high.
Move the wick height lock one position (Section F).
H MAINTENANCE
Your heater needs hardly any maintenance. It is, however, important that you
remove dust and stains in time with a damp cloth, because otherwise these may
cause stains that are hard to remove. Under normal conditions, only three
components are subject to wear:
1. THE BATTERIES
You may replace the batteries yourself. Do not dispose of old batteries along with
the other domestic waste. Follow the locally applicable regulations regarding the
disposal of domestic chemical waste.
2. THE WICK
To extend the glass fibre wick life, you must occasionally let the heater burn until
the tank is completely emptied and the heater extinguishes by itself. Do this when
you notice that the flame is weakening. The burn-out will cause some smells, so it
is recommended that you take the heater outside of the living room. If the flame
position isn’t high enough in position 3 of the wick height lock
, the wick needs
to be replaced.
Refer to section M or contact your Zibro Kamin dealer for
replacements.
3. THE IGNITION COIL
The ignition coil will last longer if you ignite in the right way. Replace the
batteries on time and make sure you do not push down the ignition slide too
forcefully. If the filament is broken, you should replace the coil.
THE FUEL FILTER
Check the fuel filter regularly as well.
Remove the removable tank
from the heater and take out the fuel filter (Fig. O).
Some drops of fuel may spill from the filter; keep a cloth at hand. Turn the fuel
filter upside down and clean it from all dirt deposits by tapping it on a hard
surface.
(Never clean it with water!) Reposition the fuel filter in the heater.
Do not remove any heater components yourself. Always contact your Zibro
Kamin dealer for repairs.
Let the heater cool down first, before you start any maintenance or service work.
I STORAGE (END OF THE HEATING SEASON)
We recommend that you burn up all the fuel in the fuel tank at the end of the heating
season and store the heater properly. Follow the next procedure:
Ignite the heater outside the living room and let it burn until all fuel is used.
Let the heater cool down.
Clean the heater with a damp cloth and then dry it with a cloth.
3
2
1
4
57
R 59 C
O
fuel filter
ignition coil
Remove the batteries from the holder and store them in a dry place.
Clean the fuel filter
(refer to Section H).
Store the heater in a dust-free place, if possible in its original packaging.
Unused fuel cannot be used for the next heating season. If there is still some
fuel left, do not throw it away, but dispose of it in accordance with the local
regulations for the disposal of domestic chemical waste.
Always start the new heating season with fresh fuel. When you start re-using
the heater, follow the instructions again
(starting from Section A and as
specified).
J TRANSPORTATION
Take the following measures to avoid fuel leakage during the transportation of
the heater:
Let the heater cool down.
Remove the removable tank
from the heater and remove the fuel filter
(Fig. O). Some drops may leak from the filter; keep a cloth at hand. Store the
fuel filter and the removable tank outside the heater.
Place the transportation cap into the position of the fuel filter (Fig. P).
Press it tight.
Always move the heater in an upright position.
K SPECIFICATIONS
Ignition electrical Dimensions (mm) width 428
Fuel paraffin (including base plate) depth 295
Capacity (kW)
*
2.7 height 513
Suitable space (m
3
)
**
45-95 Accessories: manual fuel pump
Fuel consumption (l/hr)
*
0.28 transportation cap
Fuel consumption (g/hr)
*
225 fuel cap cover
Burning time per tank (hr)
*
14 batteries
Capacity removable tank (litres) 4.0 Required batteries 2xLR 20, MN 1300,
Weight (kg) 9 alkaline 1.5V
Wick type F
* At maximum setting
** Specified values are indicative
L WARRANTY PROVISIONS
Your heater comes with a 24-month warranty starting on the date of purchase.
Within this period all defects in material or workmanship will be repaired without
any charge. The following provisions shall apply regarding this warranty:
4
3
2
1
7
6
5
4
4
58
R 59 C
P
transportation cap
O
fuel filter
We expressly dismiss all other claims for damages, including consequential
damages.
Any repairs or replacements of components within the term of warranty will
not result in an extension of the term of warranty.
The warranty shall no longer apply, when the heater has been modified,
non-original parts have been used, or when it is repaired by third parties.
The warranty shall not apply to parts that are subject to normal wear, such as
the batteries, the ignition coil, the wick and the manual fuel pump.
The warranty shall only apply, when you present the original, dated proof of
purchase, provided no changes have been made to it.
The warranty shall not apply to damages caused by actions not in compliance
with the Directions for Use, neglect, and the use of an incorrect type of fuel,
or fuel past its use-by date. The use of incorrect fuel can even be dangerous*.
Transportation costs and the risks involved during the transportation of the
heater or heater components shall always be for the account of the purchaser.
In order to avoid unnecessary costs, we recommend that you always read the
’Directions for Use’ carefully first. In case they offer no solution, please take the
heater to your dealer for repair.
* Highly inflammable substances may induce uncontrollable burning, causing flames to break out. Should this
happen, never try to move the heater, but always switch off the heater immediately
(refer to Section E). In cases
of emergency you may use a fire extinguisher, but only a type B extinguisher: a carbon dioxide or powder
extinguisher.
10 TIPS FOR SAFE USE
1 Make sure that children are always aware of the presence of a burning
heater.
2 Do not move the heater when it is burning or still hot. Do not refill nor
service the heater when it is burning or still hot.
3 Position the front of the heater at a minimum distance of 1.5 metres
from walls, curtains, and furniture.
4 Do not use the heater in dusty rooms or in very draughty places. In
both cases you will not have optimum burning.
5 Switch off the heater, before you go to sleep.
6 Store and move fuel only in suitable tanks and jerrycans.
7 Make sure that the fuel is not exposed to heat or extreme temperature
changes. Always store the fuel in a cool, dry and dark place (sunlight
will affect the quality).
8 Never use the heater in places where harmful gasses or fumes may be
present (e.g. exhaust gasses or paint fumes).
9 The top plate of the heater becomes hot. Do not cover the heater
(there is a risk of fire). Avoid any concact with the top plate and grille.
10 Always make sure that there is sufficient ventilation.
7
6
5
4
3
2
1
4
59
R 59 C
REPLACING THE WICK
M ENSURE THAT THE HEATER IS OFF AND COMPLETELY
COOLED BEFORE STARTING TO REPLACE THE WICK.
Open the lid and remove the removable tank.
Remove the batteries from the battery holder.
Check that both the igniter slide and the flame
regulator are in the uppermost position. Pull off the
plastic covers of the slides.
Open the front grill. Remove the combustion chamber
from the heater. Close the grill.
Unscrew the screws on the back and sides of the heater.
Pull the cabinet forward slightly and remove it from the
base plate. Unscrew the wing nuts from the wick holder
chassis.
Lift the wick holder chassis up until the wick is visible.
Place the burner bed next to the heater. (Ensure that
the wiring does not become disconnected).
Push the flame regulator down to adjust the wick
mechanism to its highest setting.
Turn the wick holder (with wick) to the left until it is
released and then remove it from the heater.
Remove the wick from the wick holder.
9
8
7
6
5
4
3
2
1
4
60
R 59 C
22
33
44bb
55aa
55cc
11
44aa
77
88
66
99
55bb
Place the new wick in the wick holder and press the
wick pins firmly into the holes in the wick holder.
Put the wick holder (with wick) back into position by
pushing the two large pins on the outside of the wick
holder into the rebate in the wick mechanism. Turn the
wick holder clockwise until it is firmly in place.
Put the wick holder chassis back into position.
Screw opposite wing nuts in succession until they are
hand tight.
Check that the wick mechanism works by pushing the
flame regulator all the way down and pushing on the
safety button.
Check that the tip-over-mechanism works by pushing
the flame regulator all the way down and tilting the
small piece of lead.
Put the cabinet back into position and tighten the
cabinet screws. Now put the combustion chamber back
into position. Check that it is level by sliding it slightly
to the left and the right by its handle. Close the grill.
Put the filled removable tank back into position.
Put the batteries into the battery holder (ensure that
the positive and negative poles match the + and –
marks indicated on the battery housing). Wait 30
minutes after placing the removable tank and batteries
before using the heater.
18
17
16
15
14
13
12
11
10
4
61
R 59 C
1100
1111aa
1111bb
1122
1144
1155
1166bb
1166cc
1177 1188
1133
1166aa
3 FRANCE
PVG France SARL
4, Rue Jean Sibélius
B.P. 185 - 76410
SOTTEVILLE SOUS LE VAL
tel: +33 2 32 96 07 47
fax: +33 2 32 96 07 77
i ÖSTERREICH
PVG Austria VertriebsgmbH
Salaberg 49
3350 HAAG
tel: +43 7434 44867
fax: +43 7434 44868
e BELGIË
PVG Belgium NV/SA
Industrielaan 55
2900 SCHOTEN
tel: +32 3 326 39 39
fax: +32 3 326 26 39
q SCHWEIZ
PVG Schweiz AG
Genuastrasse 15
4142 MÜNCHENSTEIN
tel: +41 61 337 26 51
fax: +41 61 337 26 78
2 DEUTSCHLAND
PVG Deutschland GmbH
Beiersdorfstraße 4
46446 EMMERICH
tel: +49 2821 76713
fax: +31 412 648385
6 DANMARK
PVG Scandinavia A/S
Niels Bohrsvej 10
6100 HADERSLEV
tel: +45 73 53 02 02
fax: +45 73 53 02 04
5 ESPAÑA
PVG España S.A.
Pol. Ind. San José de Valderas II
Comunidad ”La Alameda”
C / Aurora Boreal, 19
28918 LEGANÉS (Madrid)
tel: +34 91 611 31 13
fax: +34 91 612 73 04
4 UNITED KINGDOM
Lister Gases
Bridge Street
Holloway Bank, Wednesbury
West Midlands WS10 0AW
Tel.: +44 121 506 1818
Fax: +44 121 505 1744
email: gases@lister.co.uk
> ITALIA
PVG Italy SRL
Via Niccolò Copernico 5
50051 CASTELFIORENTINO (FI)
tel: +39 571 628500
fax: +39 571 628504
u NØRGE
Sunwind - Gylling A/S
Løxaveien 17 - P.O. Box 64
1351 RUD
tel: +47 67 17 13 70
fax: +47 67 17 13 80
1 NEDERLAND
PVG International b.v.
P.O.Box 96
5340 AB OSS
tel: +31 412 694694
fax: +31 412 622893
: POLSKA
PVG Polska Sp. z. o. o.
Kolonia Promna 58
26-803 PROMNA
tel: +48 48 615 16 33
fax: +48 48 615 16 33
9 PORTUGAL
Markt (Portugal), Lda
Recta da Granja do Marquês
ALGUEIRÃO
2725 MEM MARTINS
tel: + 351 21 922 8530
fax: + 351 21 922 8536
DISTRIBUTED IN EUROPE BY PVG INTERNATIONAL BV
PVG Traffic gsc©030225 Manual/R59C
New 3/03
Printed in Japan
7024000903
/