Gigabyte GS-R22T61 User manual

Category
Servers
Type
User manual

This manual is also suitable for

Service Guide
GIGABYTE
GS-R22T61-RH/GS-R22T81-RH
2U Rack Mount Server
Dual Intel
®
Xeon LGA1366 Processor Serverboard
Rev. 1.0
Preface
Before using this information and the product it supports, please read the following general information.
1. This Service Guide provides you with all technical information relating to the BASIC
CONFIGURATION decided for GIGABYTE's “global” product offering. To better fit local market
requirements and enhance product competitiveness, your regional office MAY have decided to
extend the functionality of a machine (e.g. add-on card, modem, or extra memory capability).
These LOCALIZED FEATURES will NOT be covered in this generic service guide. In such
cases, please contact your regional offices or the responsible personnel/channel to
provide you with further technical details.
2. Please note WHEN ORDERING FRU PARTS, you should check the most up-to-date information
available on your regional web or channel. For whatever reason, if a part number change is made,
it will not be noted in the printed Service Guide. For GIGABYTE-AUTHORIZED SERVICE
PROVIDERS, your GIGABYTE office may have a DIFFERENT part number code to those
given in the FRU list of this printed Service Guide. You MUST use the list provided by your
regional GIGABYTE office to order FRU parts for repair and service of customer machines.
3
GS-R22T61-RH/GS-R22T81-RH Rack Mount Server
Table of Contents
Preface....................................................................................................2
Safety, Care and Regulatory Information................................................5
System Specification..............................................................................9
System Hardware Installation................................................................ 11
Chassis Removal and Installation................................................................................. 12
CPU Installation ............................................................................................................... 13
Heat Sink Installation ....................................................................................................... 14
Memory Installation ......................................................................................................... 15
PCI Expansion Card Installation (GC-RLE2N-RH/GC-RFE2N-RH) .......................... 18
PCI Expansion Card Installation (GC-RFX2N-RH/Optional)....................................... 20
GS-R22T81-RH Hard Disk Drive Installation ................................................................ 22
GS-R22T61-RH Hard Disk Drive Installation ................................................................ 23
FAN Duct Removal and Installation .............................................................................. 24
Appearance of GS-R22T61-RH/GS-R22T81-RH ...................................25
Front View of GS-R22T61-RH (For 3.5 HDDs solution).............................................. 25
Front View of GS-R22T81-RH (For 2.5 HDDs solution).............................................. 25
Rear View of GS-R22T61-RH/GS-R22T81-RH ........................................................... 26
Front Panel LED Indicators ............................................................................................. 27
LAN port LED Indicator.................................................................................................... 28
Hard Disk Drive LED Description ................................................................................... 29
GC-BS28E-RH Back plane board Components Description....................................... 30
(for 2.5”HDD) .................................................................................................................... 30
GC-BS26E-RH Back plane board Components Description....................................... 32
(for 3.5”HDD) .................................................................................................................... 32
System Block Diagram................................................................................................... 34
GS-R22T61-RH Cable Routing...................................................................................... 35
.......................................................................................................................................... 35
GS-R22T81-RH Cable Routing...................................................................................... 36
Connector Icon Description............................................................................................. 37
Motherboard Placement and Jumper Setting ......................................38
GA-7TTSH-RH Motherboard Component...................................................................... 38
Motherboard Jumper Setting........................................................................................... 41
Expansion Card Components Description.................................................................... 43
4
Table of Content
BIOS Setup...........................................................................................46
Main...........................................................................................................48
Advanced ...................................................................................................50
Processor Configuration.................................................................................................. 51
Processor Power Management ..................................................................................... 55
Memory Configuration..................................................................................................... 58
Advanced Chipset Configuration ................................................................................... 60
PCI Configuration............................................................................................................. 64
SATA Configuration.......................................................................................................... 66
I/O DeviceConfiguration .................................................................................................. 69
Boot Configuration............................................................................................................ 71
Thermal and Acoustic Configuration.............................................................................. 73
Power.........................................................................................................75
Security ......................................................................................................77
Server.........................................................................................................79
System Management...................................................................................................... 80
Console Redirection........................................................................................................ 82
Event Log Configuration.................................................................................................. 84
Boot............................................................................................................85
Exit .............................................................................................................86
Appexdix A Phoenix BIOS Beep Codes .............................................92
Appexdix B PhoenixBIOS POST Error Messages List ......................96
5
GS-R22T61-RH/GS-R22T81-RH Rack Mount Server
Safety, Care and Regulatory Information
Important safety information
Read and follow all instructions marked on the product and in the documentation before you operate
your system. Retain all safety and operating instructions for future use.
* The product should be operated only from the type of power source indicated on the rating label.
* If your computer has a voltage selector switch, make sure that the switch is in the proper position for
your area. The voltage selector switch is set at the factory to the correct voltage.
* The plug-socket combination must be accessible at all times because it serves as the main disconnect-
ing device.
* All product shipped with a three-wire electrical grounding-type plug only fits into a grounding-type power
outlet. This is a safety feature. The equipment grounding should be in accordance with local and national
electrical codes. The equipment operates safely when it is used in accordance with its marked electrical
ratings and product usage instructions
* Do not use this product near water or a heat source.
* Set up the product on a stable work surface or so as to ensure stability of the system.
* Openings in the case are provided for ventilation. Do not block or cover these openings. Make sure you
provide adequate space around the system for ventilation when you set up your work area. Never insert
objects of any kind into the ventilation openings.
* To avoid electrical shock, always unplug all power cables and modem cables from the wall outlets
before removing covers.
* Allow the product to cool before removing covers or touching internal components.
Precaution for Product with Laser Devices
Observe the following precautions for laser devices:
* Do not open the CD-ROM drive, make adjustments, or perform procedures on a laser device other
than those specified in the product's documentation.
* Only authorized service technicians should repair laser devices.
Precaution for Product with Modems, Telecommunications, ot Local Area
Network Options
Observe the following guidelines when working with options:
* Do not connect or use a modem or telephone during a lightning storm. There may be a risk of electrical
shock from lightning.
6
Safety Information
* To reduce the risk of fire, use only No. 26 AWG or larger telecommunications line cord.
* Do not plug a modem or telephone cable into the network interface controller (NIC) receptacle.
* Disconnect the modem cable before opening a product enclosure, touching or installing internal
components, or touching an uninsulated modem cable or jack.
* Do not use a telephone line to report a gas leak while you are in the vicinity of the leak.
Federal Communications Commission (FCC) Statement
Warning
This is a class A product. In a domestic environment this product may cause radio
interference
In which case the user may be required to take adequate measures.
Note: This equipment has been tested and found to comply with the limits for a Class A digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against
harmful interference when the equipment is operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with
the instruction manual, may cause harmful interference to radio communications. Operation of this
equipment in a residential area is likely to cause harmful interference in which case the user will be
required to correct the interference at his own expense.
Properly shielded and grounded cables and connectors must be used in order to meet FCC emission
limits. Neither the provider nor the manufacturer are responsible for any radio or television interference
caused by using other than recommended cables and connectors or by unauthorized changes or
modifications to this equipment. Unauthorized changes or modifications could void the user's authority to
operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired
operation.
FCC part 68 (applicable to products fitted with USA modems)
The modem complies with Part 68 of the FCC Rules. On this equipment is a label that contains, among
other information, the FCC registration number and Ringer Equivalence Number (REN) for this equipment.
You must, upon request, provide this information to your telephone company.
If your telephone equipment causes harm to the telephone network, the Telephone Company may
discontinue your service temporarily. If possible, they will notify in advance. But, if advance notice is not
practical, you will be notified as soon as possible. You will be informed of your right to file a complaint with
7
GS-R22T61-RH/GS-R22T81-RH Rack Mount Server
the FCC.
Your telephone company may make changes in its facilities, equipment, operations, or procedures that
could affect proper operation of your equipment. If they do, you will be notified in advance to give you an
opportunity to maintain uninterrupted telephone service.
The FCC prohibits this equipment to be connected to party lines or coin-telephone service.
The FCC also requires the transmitter of a FAX transmission be properly identified (per FCC Rules Part
68, Sec. 68.381 (c) (3)).
/ for Canadian users only /
Canadian Department of Communications Compliance Statement
This digital apparatus does not exceed the Class B limits for radio noise emissions from digital
apparatus as set out in the radio interference regulations of Industry Canada.
Le present appareil numerique n'emet pas de bruits radioelectriques depassant les limites applicables aux
appareils numeriques de Classe A prescrites dans le reglement sur le brouillage radioelectrique edicte par
Industrie Canada.
DOC notice (for products fitted with an Industry Canada-compliant modem)
The Canadian Department of Communications label identifies certified equipment. This certification
means that the equipment meets certain telecommunications network protective, operational and safety
requirements. The Department does not guarantee the equipment will operate to the user satisfaction.
Before installing this equipment, users ensure that it is permissible to be connected to the facilities of the
local Telecommunications Company. The equipment must also be installed using an acceptable method
of connection. The customer should be aware that compliance with the above conditions might not prevent
degradation of service in some situations.
Repairs to certified equipment should be made by an authorized Canadian maintenance facility designated
by the supplier. Any repairs or alterations made by the user to this equipment, or equipment malfunctions,
may give the telecommunications company cause to request the user to disconnect the equipment.
Users should ensure for their own protection that the electrical ground connections of the power utility,
telephone lines and internal metallic water pipe system, if resent are connected together. This precaution
may be particularly important in rural areas.
Caution: Users should not attempt to make such connections themselves, but should contact the
appropriate electric inspection authority, or electrician, as appropriate.
8
Safety Information
NOTICE: The Load Number (LN) assigned to each terminal device denotes the percentage of the total
load to be connected to a telephone loop which is used by the device, to prevent overloading. The
termination on a loop may consist of any combination of devices subject only to the requirement that the
sum of the Load Numbers of all the devices does not exceed 100.
/ for European users only /
Class A equipment
This device has been tested and found to comply with the limits for a class A digital device pursuant
Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against
harmful interference when the equipment is operated in a commercial environment. This equipment
generate, uses, and can radiate radio frequency energy, and if not installed and used in accordance
with the instructions, may cause harmful interference to radio communication. Operation of this
equipment in a residential area is likely to cause harmful interference, in which case the user will be
required to correct the interference at personal expence.
However, there is no guarantee that interference will not occur in a particular installation. If this
device does cause harmful interference to radio or television reception, which can be determined by
tuning the device off and on, the user is encouraged to try to correct the interference by on or more of
the following measures:
Reorient or relocate the receiving antenna
Increase the separation between the device and receiver
Connect the device into an outlet on a circuit different from that to which the receiver is
connected
Consult the dealer or an experienced radio/television technician for help
CAUTION
Danger of explosion if battery is incorrectly
replaced.
Replace only with the same or equivalent
type recommended by the manufacturer.
Dispose of used batteries according to the
manufacturer’s instructions.
9
GS-R22T61-RH/GS-R22T81-RH Rack Mount Server
Motherboard GA-7TTSH1-RH
Processor Supported Supports dual Intel
®
Xeon
®
processors
Intel Xeon
®
Dual-Core/Quad-Core processor in LGA 1366 socket
Supports Intel Quickpath Interconnect up to 6.4 GT/s
Chipset Northbridge: Intel
®
5520 Chipset
Southbridge: Intel
®
ICH10R
System Memory:
Memory Capacity 12 x DDR 3 sockets up to 48GB/96GB (1 to 4 GB unbuffered
DIMMs for up to 48GB or 1 to 8 GB registered DIMM for up to
96GB of total system memory)
Memory Type DDR 3 133 MHz ECC registered/unbuffered DIMMs
DIMM Size 512MB, 1GB, 2GB, 4GB, and 8GB capability modules support
Error Correction: Single-bit Errors Correction, Multiple Bit Errors Detection
Riser Slot
Full height riser card: (Top) One PCI-E x8 slot (PCI-E x 8 throughput) , Gen2.
(Black color connector)
(Middle)One PCI-E x8 slot (PCI-E x 8 throughput) , Gen2.
(Black color connector)
(Bottom). (Black color connector) PCI-E x8 (PCI-E x8 throughput),
Gen2.
Full height riser card: (Optional) (Top) One PCI-X 64/133MHz (White color connector)
(Middle)One PCI-E x8 slot (PCI-E x 8 throughput) , Gen2.
(Black color connector)
(Bottom)One PCI-E x8 slot (PCI-E x 8 throughput) , Gen2.
(Black color connector)
Low-profile riser card: (Top)One PCI-E x8 slot (PCI-E x 8 throughput), Gen2.
(Black color connector)
(Middle)One PCI-E x8 slot (PCI-E x4 throughput), Gen1.
(White color connector)
SATA RAID controller Intel
®
ICH10R
Supports LSI Software RAID 0/1/10
Cooling Fans: 6 X System Fan
System Specification
10
Feature Summary
Integrated LANs:
Controller Intel
®
82576EB controller support dual GbE ports
Integrated Graphics:
Controller Integrated in Server Engines Pilot II
Graphics Memory 32MB DDR2
Mass Storage System 6 x 3.5” Hot-Swap SATA /SAS HDDs
Or, 16 x 2.5” Hot-Swap SATA /SAS HDDs
1 x DVD Combo
Super I/O
Controller ITE IT8720 Super I/O
Front I/O 1 x VGA port
2 x USB 2.0 dual-port connector
Rear I/O P/S 2 Keyboard and Mouse Connectors
1 x Serial port
4 x USB 2.0 ports
1 x VGA connector
2 x GLAN ports
1 x 10/100 LAN port
System BIOS:
BIOS Type Phoenix BIOS on 8Mb flash ROM
Server Management Functions: (Optional device)
BMC Chip Server Engines POLIT 2 IPMI 2.0 controller
Failure Detection IPMI 2.0 specification of Server management
Event Logging 32KB Nonvolatile Memory to Log System Failure Events
Remote Management Follow the IPMI 2.0 specification of Server management
Environment
Ambient Temperature Operating Temperature: 5
o
C to 35
o
C
Non-operating Temperature: 0
o
C to 50
o
C
Relative Humidity 10-80% operating Humidity at 30
o
C
System Dimention: 432mm x 210mm x 650mm
Electrical Power Supply Redundant Power Supply 750W
11
GS-R22T61-RH/GS-R22T81-RH Rack Mount Server
Pre-installation Instructions
Perform the steps below before you open the server or before you remove or replace
any component.
1. Back up all important system and data files before performing any hardware
configuration.
2. Turn off the system and all the peripherals connected to it.
3. Unplug all cables from the power outlets.
4. Disconnect all telecommunication cables from their ports.
5. Place the system unit on a flat and stable surface.
6. Open the system according to the instructions.
Warning! Failure to properly turn off the server before you start installing components
may cause serious
damage. Do not attempt the procedures described in the following sections unless you
are a qualified service
technician.
System Hardware Installation
12
Hardware Installation Process
Chassis Removal and Installation
Step 1 Remove the screw on the chassis.
Step 2 Slide toward the top chassis cover.
Step 3 Lift up to remove the top chassis cover.
Step 4 Reverse Step 1, ,2, 3 to replace the chassis cover
1
3
2
13
GS-R22T61-RH/GS-R22T81-RH Rack Mount Server
1
2
3
CPU Installation
Please make sure the CPU type and speed that are supported by the motherboard.
Step 1 Raise the metal locking lever on the socket. Insert the CPU with the correct orientation.
Step 2 The CPU only fits in one orientation.
Step 3 Push the metal lever back into locked position.
14
Hardware Installation Process
Heat Sink Installation
Step 1 Place the Heat Sink on the CPU. Before putting the heat sink on the CPU, please well
remember to apply the thermal conductivity compound on the CPU.
Step 2 Seat the heat sink in the retention modules with the four screws. Installation completed.
1
1
1
1
1
2
2
2
2
2
2
2
15
GS-R22T61-RH/GS-R22T81-RH Rack Mount Server
Memory Installation
1
2
2
CPU1
CPU2
DIMMA2
DIMMA1
DIMMB2
DIMMB1
DIMMC2
DIMMC1
DIMMD2
DIMMD1
DIMME2
DIMME1
DIMMF2
DIMMF1
Step 1. Insert the DIMM memory module vertically into the DIMM slot, and push it down.
Step 2. Close the plastic clip at both edges of the DIMM slots to lock the DIMM module.
NOTE! DIMM must be populated in order starting from DIMMA1/D1 sockets. For dualquad
channel operation, DIMMs must be installed in matched pairs.
Step 3. Reverse the installation steps when you wish to remove the DIMM module.
16
Hardware Installation Process
U-DIMM Population Table
DIMMA1/D1
1GB
Interleave
mode
Single
Channel
Dual
Channel
Three
Channel
DIMMA2/D2 DIMMB1/E1 DIMMB2/E2 DIMMC1/F1 DIMMC2/F2
Channel A Channel B Channel C
Total
Memory
2GB
4GB
1GB
2GB
4GB
1GB
2GB
4GB
2GB
4GB
8GB
8GB
4GB
1GB
2GB
4GB
1GB
2GB
4GB
1GB
2GB
4GB
1GB
2GB
4GB
1GB
2GB
4GB
1GB
2GB
4GB
1GB
2GB
4GB
1GB
2GB
4GB
1GB
2GB
4GB
1GB
2GB
4GB
1GB
2GB
4GB
1GB
2GB
4GB
1GB
2GB
4GB
1GB
2GB
4GB
6GB
12GB
16GB
6GB
3GB
16GB
24GB
17
GS-R22T61-RH/GS-R22T81-RH Rack Mount Server
R-DIMM Population Table
Interleave
mode
Single
Channel
Dual
Channel
Three
Channel
Channel A Channel B Channel C
Total
Memory
DIMMA1/D1
1GB
DIMMA2/D2 DIMMB1/E1 DIMMB2/E2 DIMMC1/F1 DIMMC2/F2
2GB
4GB
1GB
2GB
4GB
8GB
1GB
2GB
4GB
8GB
1GB
2GB
4GB
8GB
1GB
2GB
4GB
8GB
1GB 1GB
2GB
4GB
8GB
2GB
4GB
8GB
1GB
2GB
4GB
8GB
1GB
2GB
4GB
8GB
1GB
2GB
4GB
8GB
1GB
2GB
4GB
8GB
1GB
2GB
4GB
8GB
1GB
2GB
4GB
8GB
1GB
2GB
4GB
8GB
1GB
2GB
4GB
8GB
1GB
2GB
4GB
8GB
1GB
2GB
4GB
8GB
6GB
12GB
24GB
48GB
8GB
2GB
4GB
8GB
16GB
4GB
8GB
16GB
32GB
3GB
6GB
12GB
24GB
18
Hardware Installation Process
PCI Expansion Card Installation (GC-RLE2N-RH/GC-RFE2N-RH)
Step 1 Loosen the riser bracket screws which attached on on the system.
Step 2 Loosen the rest riser bracket bracket screws.
Step 3 Lift the riser bracket slightly, then pull it out from the server chassis.
Step 4 Slide the expansion card into the slot until the card firmly seats.
Step 5 Slide another expansion card into the slot until the card firmly seats.
Align the riser bracket to the system module.
3
2
1
1
2
2
19
GS-R22T61-RH/GS-R22T81-RH Rack Mount Server
4
5
20
Hardware Installation Process
PCI Expansion Card Installation (GC-RFX2N-RH/Optional)
Step 1 Loosen the riser bracket screws which attached on on the system.
Step 2 Loosen the rest riser bracket bracket screws.
Step 3 Lift the riser bracket slightly, then pull it out from the server chassis.
Step 4 Attach the PCI-E card to the riser bracket.
Step 5 Secure the card with screws.
Step 6 Attach anothr PCI-E card to the riser bracket the other side.
Step 7 Secure the card with screws.
Step 8 Align the riser bracket to the system module until it firmly seats.
3
2
1
1
2
2
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99

Gigabyte GS-R22T61 User manual

Category
Servers
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI