Wolf WWD FRONT/S Installation guide

Category
Warming drawers
Type
Installation guide

This manual is also suitable for

Warming Drawers
INSTALLATION GUIDE
Important Note
T
o ensure the safe and efficient use of Wolf equipment,
please take note of the following types of highlighted
information throughout this guide:
IMPORTANT NOTE highlights information that is
especially important.
CAUTION signals a situation where minor injury or product
damage may occur if instructions are not followed.
WARNING states a hazard that may cause serious injury or
death if precautions are not followed.
Contents
Wolf Warming Drawers . . . . . . . . . . . . . . . . . . . . . . . . . 3
Installation Considerations . . . . . . . . . . . . . . . . . . . . . . 4
Warming Drawer Installation . . . . . . . . . . . . . . . . . . . . 7
Service Information . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Features and specifications are subject to change at any time
without notice. Visit wolfappliance.com/specs for the most
up-to-date information.
IMPORTANT NOTE: Throughout this guide, dimensions in
parentheses are millimeters unless otherwise specified.
Wolf Warming Drawers 3
wolfappliance.com/specs
Warming Drawer Installation
IMPORTANT NOTE: T
his installation must be completed
by a qualified installer or Wolf authorized service center
technician.
Read this entire installation guide prior to installation and
save for the local inspector’s reference. The homeowner
should keep this installation guide for future reference.
IMPORTANT NOTE: The warming drawer must be installed
with a Wolf stainless steel or integrated drawer front.
This appliance must be installed in accordance with
National Electrical Codes, as well as all state, municipal
and local codes. The correct voltage, frequency and
amperage must be supplied to the appliance from a dedi-
cated, grounded circuit which is protected by a properly
sized circuit breaker or time delay fuse. The proper
voltage, frequency, and amperage ratings are listed on the
product rating plate.
Record the model and serial numbers before installing the
warming drawer. Both numbers are listed on the product
rating plate, located on the left front floor area of the inner
cabinet. To access the rating plate, the drawer must be
fully open. Refer to the illustration below.
Location of rating plate.
RATING
PLATE
Wolf Warming Drawer
Model Number
Serial Number
Installation Considerations 4
Before You Start
Proper installation is the responsibility of the installer.
Product failure due to improper installation is not
covered under the Wolf warranty. Refer to the warming
drawers use & care guide for warranty details.
Warranty service must be performed by a Wolf author-
ized service center. Wolf is not responsible for service
required to correct a faulty installation.
The warming drawer must be installed with a Wolf
stainless steel or integrated drawer front. Make sure
you have the accessory drawer front called for in your
installation. Specific installation instructions are
included with the drawer front.
Make sure cabinetry meets the minimum dimension
requirements for your specific installation.
Check with local utilities for electrical codes that apply
in your area. Local codes vary. Installation, electrical
connections and grounding must comply with applica-
ble codes. In the absence of local codes, the drawer
should be installed in accordance with National Electri-
cal Code ANSI/NFPA 70-1990 or latest edition.
This appliance must be properly grounded. Refer to
electrical requirements on th following page.
Make sure you have the tools and materials necessary
for proper installation.
TOOLS AND MATERIALS REQUIRED
Minimum
3
/4" (19) thick lumber for the solid platform
that supports the warming drawer—must be able to
support 200 lbs (91 kg).
Wood screws and hardware to install the platform.
2" x 2" or 2" x 4" lumber for anti-tip block.
Power saw.
Level.
Drill and
1
/1
6
" bit,
1
/2" bit also for integrated drawer
front application.
Phillips screwdriver.
2 wood screws (provided).
Wood cleats (optional).
Installation Considerations 5
wolfappliance.com/specs
Installation Considerations
The warming drawer must be installed with a Wolf
stainless steel or integrated drawer front. Specific
installation instructions are included with the drawer
front.
Model WWD30O is CSA approved for outdoor
installations.
For all installations, the warming drawer must be fully
enclosed, top and bottom.
The warming drawer platform must be able to support
200 lbs (91 kg). The platform must be a minimum of 1"
(25) above the toe kick to allow for the warming drawer
trim which overlaps
5
/8" (16) on all four sides.
For undercounter installations, 23
1
/2" (597) from the
bottom of the opening to the floor is typical.
COMBINATION INSTALLATIONS
Refer to illustrations showing combination installations on
the following pages. Also refer to installation instructions
provided with the other Wolf products.
The warming drawer may be installed in combination
with a Wolf built-in oven and/or microwave. Additional
clearance between warming drawer and oven openings
may be required. To allow the warming drawer trim and
the oven trim to meet, a
7
/8" (22) platform may be used
to separate the two openings. This will act as the
support platform for the oven and the anti-tip device
for the warming drawer. An anti-tip block may be
installed at the rear of the cabinet in place of the
platform. If the warming drawer is installed above an
oven, a
7
/8" (22) platform is required to allow for clear-
ance of overlaps.
The warming drawer may be installed below a Wolf
cooktop or sealed burner rangetop. Allow enough
room for gas and electrical connections for the
cooktop.
The warming drawer may be installed next to or above
another Wolf warming drawer.
Model WWD30O may be installed below a Wolf
outdoor grill.
Electrical Requirements
Power Supply 120 V AC, 50/60 Hz
Circuit Breaker 15 or 20 amp
Receptacle 3-prong grounding-type
Electrical Requirements
T
he electrical supply should be located as shown in the
illustration for your specific installation on the following
pages. A separate circuit, servicing only this appliance is
required.
IMPORTANT NOTE: You must follow all National Electrical
Code regulations. In addition, be aware of local codes and
ordinances when installing your service.
If two warming drawers are installed side by side, they can
operate from the same electrical outlet. A 30 amp circuit
breaker is required for this installation.
IMPORTANT NOTE: When installed outdoors, a ground
fault circuit interrupter (GFCI) is required to reduce the risk
of electrical shock.
Installation Considerations 6
22
3
/4" (578)
28
1
/4" (718)
9"
(229)
10
3
/8"
(264)
21
1
/2"
(546)
3
/4"
(19)
3
/4" (19)
A
B
B
29
7
/8" (759)
OR
35
7
/8" (911)
Drawer Front Options
IMPORTANT NOTE: T
he warming drawer must be installed
with a Wolf stainless steel or integrated drawer front.
Wolf stainless steel and integrated drawer fronts allow for
many design options, but the warming drawer itself will be
the same for all applications.
When installing a Wolf warming drawer in combination
with an L series or E series built-in oven, you may choose
the stainless steel drawer front to match the trim and
handle of your oven.
The E series 2" (51) thick drawer front with pro handle, in
30" (762) and 36" (914) widths, is designed to be installed
below a sealed burner rangetop or outdoor gas grill, so
the panel aligns properly with the front of the rangetop or
grill.
Keep in mind, overall dimensions for the warming drawer
remain the same, even though the drawer front may be
wider to match a Wolf 36" (914) wide oven, sealed burner
rangetop or outdoor grill.
OVERALL DIMENSIONS
Dimensions may vary ±
1
/8" (3).
Stainless Steel Drawer Front
L SERIES AB
Tubular Handle
7
/8" (22) 3
1
/2" (89)
E SERIES AB
Tubular Handle 1
1
/8" (29) 3
1
/2" (89)
Pro Handle 1
1
/8" (29) 3
1
/2" (89)
Pro Handle (2" thick) 2
1
/8" (54) 4
1
/2" (114)
Integrated Drawer Front
CUSTOM PANEL WHD
Typical 29
7
/8" (759) 10
3
/8" (264)
3
/4" (19)
Warming Drawer Installation 7
wolfappliance.com/specs
M
ounting holes will need to be drilled in the back of the
drawer front panel. Holes should be drilled on site to
ensure proper fit and gaps are achieved. A drilling
template is provide with the integrated drawer front.
IMPORTANT NOTE: Be sure to finish the inside lip of the
opening and the front face of the platform and cleats.
These areas may be visible when the drawer is open.
IMPORTANT NOTE: Be aware of the location of the
mounting holes on the warming drawer frame to make
sure screws used to attach the cleats do not interfere with
screw holes for mounting the warming drawer.
PLATFORM
TOP CLEAT
SIDE CLEAT
CABINETRY
OPENING
CLEATS AND PLATFORM
RECESSED
3
/16" (5)
Recessed application. Flush inset application.
PLATFORM
TOP CLEAT
SIDE CLEAT
CABINETRY
OPENING
CLEATS AND PLATFORM
RECESSED
3
/16" (5)
PLUS THICKNESS
OF DECORATIVE PANEL
Installation Options
STANDARD, RECESSED OR FLUSH INSET INSTALLATION
The warming drawer with E series drawer front can be
installed in a standard, recessed or flush inset application.
For a standard installation, the drawer collar and front
panel sit proud of the cabinet face frame. A recessed
installation requires the cabinetry be recessed by
3
/16" (5)
so the collar is flush with the cabinet face frame but the
drawer front will sit proud. A flush inset installation
requires the drawer collar and front panel be recessed to
be flush with surrounding cabinetry. Refer to illustrations
on the following pages for minimum cabinet dimensions
for your specific installation.
INSTALL RECESSED CLEATS AND PLATFORM
For a recessed or flush inset application, you will need to
install a recessed platform and cleats into the opening.
Proper recess of the platform and cleats is critical to the
function and esthetics of the warming drawer installation.
The depth of the platform may increase with the cabinet
depth. Be sure to rigidly mount the platform so that it
can support a minimum of 200 lbs (91 kg). Refer to the
illustrations below.
Warming Drawer Installation 8
2"(
51) x
2"(
51)
ANTI-TIP BLOCK
DIMENSION
WILL VARY*
*Dimension must accommodate height of anti-tip block and drawer face overlap.
NOTE: Location of electrical supply within opening may require additional cabinet depth. Dashed line represents profile of unit.
FRONT VIEWSIDE VIEW
E
24" (610) min
C
ABINET DEPTH
2
8
5
/8" (
727)
O
PENING WIDTH
P
LATFORM
9
1
/8" (
232)
OPENING HEIGHT
10
3
/8"
(264)
2
3
1
/2"
(597)
T
YPICAL
36" (914)
FLOOR TO
COUNTERTOP
Standard Installation
L SERIES, E SERIES OR INTEGRATED DRAWER FRONT
Warming Drawer Installation 9
wolfappliance.com/specs
2"(51) x 2" (51)
A
NTI-TIP BLOCK
DIMENSION
WILL VARY*
23
1
/2"
(597)
TYPICAL
*Dimension must accommodate height of anti-tip block and drawer face overlap.
NOTE: Dimensions provided allow for
1
/4" (6) reveal for proper air flow. Location of electrical supply within opening may require additional
cabinet depth. Dashed line represents profile of unit.
FRONT VIEWSIDE VIEW
24" (
610) min
CABINET DEPTH
30
3
/8" (
772)
FLUSH INSET WIDTH
28
5
/8" (727)
O
PENING WIDTH
7
/8" (22) PLATFORM
7
/8" (22) TOP AND SIDE CLEATS
36" (914)
FLOOR TO
COUNTERTOP
10
7
/8" (276)
FLUSH INSET
HEIGHT
9
1
/8" (232)
O
PENING HEIGHT
E
E
SIDE CLEATS
24 (
610) min
F
LUSH INSET
DEPTH
1
"
(
25)
T
OP VIEW
Flush Inset Installation
E SERIES OR INTEGRATED DRAWER FRONT
Warming Drawer Installation 10
24" (
610) min
O
PENING DEPTH
*Platform must support 250 lbs (113 kg).
NOTE: Location of electrical supply within oven opening may require additional cabinet depth.
FRONT VIEWSIDE VIEW
28
5
/8" (727)
WARMING DRAWER
OPENING WIDTH
28
1
/2" (724)
O
VEN OPENING WIDTH
E
E
MICROWAVE
OPENING
27
3
/1
6
"
(
691)
1
1
/2" (38)
min
9
1
/8" (232)
3
/4" (19)
min
PLATFORM*
E
E
5"
(127)
4"
(102)
Standard Tower Installation
INSTALLATION WITH MICROWAVE AND BUILT-IN OVEN
Warming Drawer Installation 11
wolfappliance.com/specs
25" (
635) min
CABINET DEPTH
30
3
/8" (772) min
FLUSH INSET WIDTH
S
IDE CLEATS
24
3
/4"
(
629) min
F
LUSH
I
NSET
D
EPTH
1
"
(25)
*Platform must support 250 lbs (113 kg).
NOTE: Location of electrical supply within oven opening may require additional cabinet depth. Dashed line represents profile of unit.
FRONT VIEWSIDE VIEW
TOP VIEW
10
5
/8"
(270)
FLUSH INSET
HEIGHT
9
1
/8" (232)
OPENING HEIGHT
E
1" (25) PLATFORM
28
5
/8" (727)
WARMING DRAWER
OPENING WIDTH
17" (
432)
OPENING
HEIGHT
18
1
/2" (
470)
F
LUSH INSET
H
EIGHT
27
1
/2" (699)
STANDARD MICROWAVE
OPENING WIDTH
E
28
1
/2" (724)
E SERIES OVEN
OPENING WIDTH
11
/16" (17) T
OP CLEAT
9
/16" (14)
PLATFORM*
1" (25)
SIDE CLEATS
E
E
5"
(127)
4"
(102)
27
3
/16"
(691)
OPENING
HEIGHT
28
1
/8"
(714) min
FLUSH INSET
HEIGHT
1
1
1
/16" (43) PLATFORM
Flush Inset Tower Installation
INSTALLATION WITH STANDARD MICROWAVE AND E SERIES OVEN
Warming Drawer Installation 12
25" (
635) min
CABINET DEPTH
30
3
/8" (772) min
FLUSH INSET WIDTH
S
IDE CLEATS
24
3
/4"
(
629) min
F
LUSH
I
NSET
D
EPTH
1
"
(25)
*Platform must support 250 lbs (113 kg).
NOTE: Location of electrical supply within oven opening may require additional cabinet depth. Dashed line represents profile of unit.
FRONT VIEWSIDE VIEW
TOP VIEW
10
5
/8"
(270)
FLUSH INSET
HEIGHT
9
1
/8" (232)
OPENING HEIGHT
E
1" (25) PLATFORM
28
5
/8" (727)
WARMING DRAWER
OPENING WIDTH
18
7
/8" (
479)
OPENING
HEIGHT
20
1
/8"
(
511)
F
LUSH INSET
HEIGHT
27
1
/2" (699)
CONVECTION MICROWAVE
OPENING WIDTH
E
28
1
/2" (724)
E SERIES OVEN
OPENING WIDTH
1
/2" (
13)
T
OP CLEAT
9
/16" (14)
PLATFORM*
1" (25)
SIDE CLEATS
E
E
5"
(127)
4"
(102)
27
3
/16"
(691)
OPENING
HEIGHT
28
1
/8"
(714) min
FLUSH INSET
HEIGHT
1
5
/8" (41) PLATFORM
Flush Inset Tower Installation
INSTALLATION WITH CONVECTION MICROWAVE AND E SERIES OVEN
Warming Drawer Installation 13
wolfappliance.com/specs
27
3
/1
6
"
(691)
OPENING
H
EIGHT
28
1
/8"
(714) min
FLUSH INSET
HEIGHT
28
1
/2" (724)
E SERIES OVEN
OPENING WIDTH
25" (
635) min
C
ABINET DEPTH
30
3
/8" (772) min
FLUSH INSET WIDTH
28
1
/2" (724)
DRAWER MICROWAVE
OPENING WIDTH
E
7
/8"(
22)
TOP CLEAT
9
/16" (14)
PLATFORM*
5
/8" (16) PLATFORM
S
IDE CLEATS
24
3
/4"
(
629) min
F
LUSH
I
NSET
D
EPTH
1
1
/4" (
32)
F
OR MICROWAVE
1" (25) F
OR
O
VEN
A
ND WARMING
DRAWER
*Platform must support 250 lbs (113 kg.
NOTE: Location of electrical supply within oven opening may require additional cabinet depth. Dashed line represents profile of unit.
FRONT VIEWSIDE VIEW
TOP VIEW
14
3
/4" (375)
OPENING
HEIGHT
15
3
/8"
(391)
FLUSH INSET
HEIGHT
1" (25)
SIDE CLEATS
10
5
/8"
(270)
FLUSH INSET
HEIGHT
9
1
/8" (232)
OPENING HEIGHT
E
1" (25) PLATFORM
28
5
/8" (727)
WARMING DRAWER
OPENING WIDTH
E
E
5"
(127)
4"
(102)
Flush Inset Tower Installation
INSTALLATION WITH DRAWER MICROWAVE AND E SERIES OVEN
Install the Warming Drawer
U
npack the warming drawer on a flat surface. Remove all
packaging materials from inside the warming drawer. Do
not discard the package containing the two wood screws
needed for installation.
Turn power off to the electrical outlet.
Slide the left corner of the warming drawer into the
opening. If the electrical outlet is installed inside the
opening, plug the power cord into the outlet. The excess
cord should be coiled behind or beside the unit. If the
outlet is located in an adjacent cabinet, thread the power
cord through the hole in the cabinet wall. Push the drawer
back into the opening until the trim meets the cabinet
front. Make sure the power cord does not get trapped
under the warming drawer.
IMPORTANT NOTE: Do not lift up on the handle to push
the drawer into place.
Open the warming drawer to its full extension. Drill pilot
holes in each side hole, located toward the front on each
side of the warming drawer. Install the wood screws
provided with the unit. Refer to the illustration below.
Turn power back on to the electrical outlet.
LOCATION OF
SIDE HOLE
Location of side hole.
Anti-Tip Block
INSTALL ANTI-TIP BLOCKING
Install a 2" (51) x 2" (51) or 2" (51) x 4" (102) anti-tip block
against the rear cabinet wall. When the warming drawer is
installed below a built-in oven, you may use a
7
/8" (22)
thick platform to allow the warming drawer trim and the
oven trim to meet. The platform will act as an anti-tip
device for the warming drawer.
An anti-tip block or platform must be installed to
prevent the warming drawer from tipping forward while
opened when loaded. Failure to do so could result in
personal injury and damage to the cabinet.
Warming Drawer Installation 14
Troubleshooting
IMPORTANT NOTE: I
f the warming drawer does not
operate properly, follow these troubleshooting steps:
Verify that power is being supplied to the warming
drawer.
Check electrical connections to ensure that the instal-
lation has been completed correctly.
Refer to the troubleshooting guide in the Wolf warming
drawers use & care guide.
If the warming drawer still does not work, contact a
Wolf authorized service center. Do not attempt to repair
the warming drawer yourself. Wolf is not responsible
for service required to correct a faulty installation.
Service Information 15
Service Information
I
f service is necessary, maintain the quality built into your
warming drawer by calling a Wolf authorized service
center.
To obtain the name and number of a Wolf authorized
service center, check the contact & support section of our
website, wolfappliance.com or call Wolf customer service
at 800-332-9513.
When calling for service, you will need the model and
serial number of the warming drawer. Both numbers are
listed on the product rating plate, located on the left front
floor area of the inner cabinet. To access the rating plate,
the drawer must be fully open. Refer to the illustration
below.
wolfappliance.com/specs
The information and images in this guide are the copyright property of Wolf Appliance, Inc. Neither this guide nor any information or images contained
herein may be copied or used in whole or in part without the express written permission of Wolf Appliance, Inc. ©Wolf Appliance, Inc. all rights reserved.
Location of rating plate.
RATING
PLATE
WOLF APPLIANCE, INC. P. O. BOX 44848 MADISON, WI 53744 WOLFAPPLIANCE.COM 800.332.9513
812542 REV-B 3/2010
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16

Wolf WWD FRONT/S Installation guide

Category
Warming drawers
Type
Installation guide
This manual is also suitable for