Highpoint RocketRAID 4310 User guide

Category
Peripheral controllers
Type
User guide

This manual is also suitable for

RocketRAID 43xx
SAS/SATAII Host Adapter
Users Guide
Revision: 1.0
Date: February 2009
HighPoint Technologies, Inc.
1
Copyright
Copyright © 2009 HighPoint Technologies, Inc. This document contains materials
protected by International Copyright Laws. All rights reserved. No part of this
manual may be reproduced, transmitted or transcribed in any form and for any
purpose without the express written permission of HighPoint Technologies, Inc.
Trademarks
Companies and products mentioned in this manual are for identification purpose only.
Product names or brand names appearing in this manual may or may not be registered
trademarks or copyrights of their respective owners. Backup your important data
before using HighPoint’s products and use at your own risk. In no event shall
HighPoint be liable for any loss of profits, or for direct, indirect, special, incidental or
consequential damages arising from any defect or error in HighPoint’s products or
manuals. Information in this manual is subject to change without notice and does not
represent a commitment on the part of HighPoint.
Notice
Reasonable effort has been made to ensure that the information in this manual is
accurate. HighPoint assumes no liability for technical inaccuracies, typographical, or
other errors contained herein.
2
Table of Contents
HIGHPOINT TECHNOLOGIES, INC.....................................5
CONGRATULATIONS
1 - Specifications and Features .....................................................................................6
2 - Kit Contents .............................................................................................................8
HARDWARE -- DESCRIPTION AND INSTALLA-
TION
1 - RocketRAID Adapter layout ....................................................................................9
2 - Installing the RocketRAID Host Adapter..............................................................15
3 - Verifying Installation ..............................................................................................17
4 - Battery Backup.......................................................................................................17
ROCKETRAID BIOS UTILITY
1 - BIOS Setting Overview ..........................................................................................18
2 - Creating RAID Arrays ............................................................................................22
3 - Deleting Arrays ......................................................................................................27
4 - Monitoring the Host Adapter, Arrays and Devices ...............................................28
5 - Maintaining Arrays ................................................................................................31
6 - Additional Functions and Settings ........................................................................36
Table of Contents
3
HIGHPOINT RAID MANAGEMENT AND DE-
VICE DRIVER CD
1 - Creating a Driver Diskette ......................................................................................39
2 - Device Driver Installation ......................................................................................40
3 - HighPoint RAID Management Utilities (HRM) ......................................................46
CUSTOMER SUPPORT
Troubleshooting Checklist .........................................................................................57
CONTACT US ......................................................................................................58
4
Table of Contents
HighPoint Technologies, Inc.
HighPoint Technologies, long recognized as a leader in mass storage technologies
specializes in the design and manufacturer of HBA (Host Bus Adapters) and
HighPoint RAID IP (Intellectual Property). HighPoint provides a broad range of
scalable hardware HBAs that meet the storage requirements from Enterprise to SMB
(Small Medium Sized Business) to PC enthusiast.
The HighPoint RAID IP includes TerabyteArchitecture™ for (Performance, Protec-
tion and Prevention).
TerabyteStream™ - leverages the built-in Intel Xscale XOR Engine to deliver unprec-
edented RAID 5 and 6 performances.
TerabyteGuard™ - prevents data lose and increases data reliability with advanced
hard drive inspection features utilizing bad sector repair and remapping.
TerabyteSaver™ - optimizes data protection with a battery backup and with write
journaling thus preventing data loss.
5
Table of Contents
Congratulations
Congratulations
You have purchased one of the highest performing and SAS/SATA hardware RAID
controllers available. The RocketRAID 4300 series offers the performance and data
protection features for homogeneous storage environments. The RocketRAID 4300
series meets the bandwidth requirements for high performance applications like video
capture and editing, CAD/CAM and digital graphics.
Remember to visit the HighPoint websites at http://www.highpoint-tech.com and
http://www.hptmac.com. There you can find information on all of HighPoint’s prod-
ucts with FAQ’s, online manuals, BIOS and driver updates.
1 - Specifications and Features
Host Adapter Architecture
TerabyteStream™ for Blazing Performance
TerabyteSaver™ and TerabyteGuard™ for Data Protection and Reliability
Intel IOP 81348 (1.2GHz)
Intel IOP 81348 (800MHz)(RocketRAID RR4310/4311)
PCI -Express x8 (compatible with x16 slot)
256 MB(RocketRAID 4320/4310/4311) / 512MB(RocketRAID 4322/4321) of
DDR II memory with ECC protection
RocketRAID 431x directly support up to 4 SAS/SATAII drives ,and up to 128
SAS devices via SAS expanders
RocketRAID 432x directly support up to 8 SAS/SATAII drives , and up to
128 SAS devices via SAS expanders
Multi adapter support up to 4 adapters
Intel RAID 6 (P+Q) for large capacity RAID arrays
NVRAM for write journaling
Battery Backup Unit (BBU) Optional
RoHS compliant
6
Congratulations
Advanced RAID Features
7
Array Monitors, Alerts and Indicators
HighPoint RAID Management (HRM)
Supports RAID 0,1,3,5,6,10,50 and JBOD
Multiple RAID array support
Multiple logical drive support
BIOS booting support
BIOS PnP and BBS (BIOS boot specification)support
Write through and write back cache
Online Array roaming
Online capacity expansion (OCE) and Online RAID level migration (ORLM)
Quick and Background initialization for instant RAID configuration
Automatic RAID rebuild
64bit LBA support greater than 2TB per volume
S.M.A.R.T monitoring hard drive status for reliability
Staggered Drive Spinup
(MAID) spin down drives in array when idle
ATA pass-through mode support
Firmware update while running the Operating System
SMTP for email notification
Hardware Monitor function(RocketRAID 432x)
Alarm / Buzzer alerts for drive failure
SAF-TE (I2C) and SGPIO enclosure management (RocketRAID432x/4310)
SAF-TE(I2C) enclosure management (RocketRAID 4311)
SNMP for remote management(RocketRAID 432x)
Ethernet port for (OBM) Out of Band Management (RocketRAID 432x)
NTP (Network Time Protocol)(RocketRAID 432x)
Intelli-VRM. (Intelligent Virtual RAID Management)
SHI – Storage Health Inspector (S.M.A.R.T. and disk maintenance)
Hot key (ctrl-h) boot-up RAID manager via BIOS
Web browser-base RAID management software
Command Line Interface (CLI)
API library for customizing AP
Congratulations
Operating System Support
Windows XP, 2003, Vista, 2008 (32 and 64-bit versions)
Linux (Fedora Core, Red Hat Enterprise / CentOS, SuSE, Debian, Ubuntu)
Mac OS X 10.4.x and above FreeBSD
Freebsd
GPL licensed driver into Linux Kernel 2.6.25
2 - Kit Contents
RocketRAID Host Adapter
Users Guide
HighPoint RAID Management and Device Driver CD
Internal Mini-SAS to Mini-SAS cables (RocektRAID 4310/4320/4321)
8
Physical Specifications
Size: (163.0mm x 68.0mm) 6.42”L x 2.68” W (RocektRAID 4322)
Size: (167.0mm x 68.0mm) 6.57”L x 2.68” W
WEMI : FCC Part 15 Class B and CE
Thermal and Atmospheric Characteristics:
Work Temperature Range: +5 C ~+ 55 C
Relative Humidity Range: 5% ~ 60% non condensing
Storage Temperature: -20C ~ +80 C
MTBF: 920,585 Hours
Electrical Characteristics:
Hardware - Description and Installation
Hardware – Description and Installation
1-RocketRAIDAdapter layout
1.1 – RocketRAID 431x/4321 Adapter layout
Port1- This is provided for theRocketRAID 4310/4321.
This represent the RocketRAID 4310/4321’s a Internal Mini-SAS port.
Port2 -This is provided for theRocketRAID 4311/4321.
This represent the RocketRAID 4311/4321’s a External Mini-SAS port.
Each port can directly support up to 4 SAS/SATA hard disks.
A1,F1
A1 is Disk Activity LED’s; F1 is Disk Failure LED’s.These connectors are provided for
RocketRAID 4310/4321’s Internal Mini-SAS port.
(illustration shows the RocketRAID 4321)
9
Hardware – Description and Installation
Pin - SAS/SATA channel/port stable:
J1
This connector supports SAF-TE interface (I2C).
J2
LCD connector for LCD Panel and Push Button
Pins defined as follow:
10
Hardware – Description and Installation
11
J3 (BBU connector)
Connector for HPTBBU-03 (HighPoint Battery Backup Unit 03,optional part,sold
separately—see “Battery Backup” for details).
BEEP1 – Speaker
Alarm (speaker): the speaker emits an audible alarm in the case of disk/array failure.
J4 - Ethernet Port (RocketRAID 4321)
Ethernet port for Out of Bound Management, support Net Time Protocol.
Cable – Internal Mini-SAS to Mini-SAS
The RocketRAID 4310/4321 includes 1 Internal Mini-SAS to Mini-SAS cables.
1.2 – RocketRAID 4320 Adapter layout
Port1- Port2 - These represent the RocketRAID 4320’s 2 Internal Mini-SAS ports.
Each port can directly support up to 4 SAS/SATA hard disks.
J9,J10,J11,J12
J9,J10 are Disk Activity LED’s; J11,J12 are Disk Failure LED’s.
Pin - SAS/SATA channel/port stable:
12
Hardware – Description and Installation
13
Pin definitions:
Pin 1: SCL; Pin 2: GND; Pin 3: SDA.
J14 (BBU connector)
Connector for HPTBBU-03 (HighPoint Battery Backup Unit 03,optional part,sold
separately—see “Battery Backup” for details).
BEEP1 – Speaker
Alarm (speaker): the speaker emits an audible alarm in the case of disk/array failure.
Ethernet Port
Ethernet port for Out of Bound Management, support Net Time Protocol.
Cable – Internal Mini-SAS to Mini-SAS
The RocketRAID 4320 includes 2 Internal Mini-SAS to Mini-SAS cables.
J16
This connector supports SAF-TE interface (I2C).
Hardware – Description and Installation
1.3 – RocketRAID 4322 Adapter layout
Port1, Port2
These represent the RocketRAID ’s 2 External Mini-SAS ports. Each port can directly
support up to 4 SAS/SATA hard drives.
J3 (Battery connector)
Connector for HPTBBU-03 (HighPoint Battery Backup Unit 03,optional part,sold
separately—see “Battery Backup” for details).
BEEP1 – Speaker
Alarm (speaker): the speaker emits an audible alarm in the case of disk/array failure.
J4 (HighPoint Ethernet Board connector)
Connector for HighPoint Ethernet Board ( see “Installing the HighPoint Ethernet
Board” for details)
14
Hardware – Description and Installation
2.1 – Installing the RocketRAID 431x/4320/4321 Host Adapter
15
2 – Installing the RocketRAID Host Adapter
Note: Make sure the system is powered-off before installing the RocketRAID 431x/
4320 /4321host adapter.
1. Open the system chassis and locate an unused PCI-E x8 or x16 slot.
2. Remove the PCI slot cover.
3. Gently insert the RocketRAID 431x/4320/4321 into the PCI-E slot, and secure the
bracket to the system chassis.
4. After installing the adapter, attach the Mini-SAS cables to the RocketRAID 4310/
4320/4321’s Mini-SAS port, and the chassis backplane. Each Mini-SAS cable
supports up to 4 hard disk drives. Consult the chassis’s manual for proper
installation procedures.
(illustration shows the RocketRAID 4320)
5. Close and secure the system chassis.
Hardware – Description and Installation
2.2 – Installing the RocketRAID 4322 Host Adapter
Note: Make sure the system is powered-off before installing the RocketRAID 4322
host adapter.
1. Installing the HighPoint Ethernet Board – the following illustration shows the
HighPoint Ethernet Board.
U1 is the RJ45 connector. J1 is connector for connecting the HighPoint Ethernet
Board to the RocketRAID Host Adapter. If you want to use the Ethernet functions,
connect the HighPoint Ethernet Board to the RocketRAID Host Adapter via connec-
tors J4 through J1, and secure the two boards to the bracket. If you do not want to
use the Ethernet function, secure the RocketRAID Host Adapter to the bracket.
1. Open the system chassis and locate an unused PCI-Express x8.
2. Remove the PCI slot cover.
3. Gently insert the RocketRAID 4322 into the PCI-Express slot, and secure the
bracket to the system chassis.
4. Close and secure the system chassis
16
Hardware – Description and Installation
3 - Verifying Installation
.
(illustration shows the RocketRAID 4322)
A battery backup option is available as an optional add-on component. The battery
provides additional data security in case of a critical system failure. Data normally lost
during a major system fault, such as a power outage or CPU failure, which was in
transit at the time of the failure (stored in the card’s onboard cache), will remain viable
for up to 72 hours. The battery unit can be attached to the card using the BBU CONN.
Attach the BBU to the RocketRAID 431x/432x, using the cable included with the BBU
unit:
Once the RocketRAID host adapter and hard drives have been installed into the
chassis, boot-up the system to verify that the hardware is properly recognized.
1. Power on the system. If the system detects the presence of the adapter, the
RocketRAID BIOS Utility will be displayed during bootup.
2. Press Ctrl+H to access the RocketRAID adapter’s BIOS Utility.
The BIOS Utility will display information about hard disks attached to the adapter.
Make sure all attached disks are detected by this utility. If any of the hard disks are
not detected, power down the system and check the power and cable connections
4 - Battery Backup
17
RocketRAID BIOS Utility
RocketRAID BIOS Utility
The RocketRAID 431x/432x card will display it’s BIOS screen during the system’s
boot process.
Using the BIOS Utility
The following keys utilized by the RocketRAID 432x BIOS utility:
F10 – press F10 to highlight the tool bar Menu.
Arrow keys – use these to move between different menu items
Enter – Open the selected toolbar command/execute the selected command.
Esc – move back to the previous menu, cancel the selected operation.
Tab – Switch between Disk and Array menus, move to next Menu item.
Space Bar – select an item (when selecting Block Size for a RAID configuration, for
example).
Press Control + H when prompted, to access the BIOS settings Menu.
1 - BIOS Settings Overview
The RocketRAID 432x BIOS utility is an interface that provides management com-
mands and controller related settings.
Now, RocketRAID 432x will be used for illustrating ,you will know how to do BIOS
Utility of RocketRAID controllers .RocketRAID 431x are similar to RocketRAID 432x,
except for channel number ,Ethernet port and Hardware Monitor function.
18
RocketRAID BIOS Utility
To log on as a User, use the arrow keys to highlight “User mode”, and press Enter.
To log on as Supervisor, select “Supervisor Mode”:, and press Enter.
BIOS Menu Shortcuts
The BIOS interface can also be navigated using key stroke combinations (Alt +” X”).
When viewing the interface, letters highlighted in “red” represent the “X” values:
“S” – System
“D” – Disk
“A” – Array
“C” – Controller
“W” – Window
“H” – Help
“X” - Exit
Logging In
The BIOS Utility has two interface modes: User and Supervisor
The User mode can only view information about the RocketRAID card, disks and
arrays.
The Supervisor mode is used to create/delete arrays, and configure RocketRAID
related settings. Supervisor mode requires a password – this is the same password
that you will need in order to use the Web Management interface.
Press F10 – this should bring you to the “System” toolbar command. Press Enter.
19
RocketRAID BIOS Utility
You will be asked to enter the Supervisor password.
The default password is “hpt”.
BIOS Commands
System
User/Supervisor modes – interface modes
Change password - for Supervisor mode
Exit the utility – quit and exit the RocketRAID BIOS utility
Disk
Information – displays information about the select hard disks
Initialize – initialize the selected disks (required in order to use new hard disks for
creating RAID arrays, disk replacement, or configuring spare disks.
Toggle Spare – configure spare disks.
Unplug – remove the selected disks (hot-swap)
Turn on write cache – enable write cache for the selected disks
Turn off write cache – disable write cache for the selected disks
Rescan – prompts the RocketRAID card to scan for new hard disks.
20
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60

Highpoint RocketRAID 4310 User guide

Category
Peripheral controllers
Type
User guide
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI