HEATER WIRE
(WHEN REQ'D)
LIGHT BASE
(WHEN REQ'D)
LIGHT(S)
(WHEN REQ'D)
RED
BLACK
WHITE
GROUND
BLACK
WHITE
RED
J-BOX
J-BOX
(BY OTHERS)
MAIN DOOR SECTION
(MAIN POWER IN)
RHEOSTAT
SWITCH
(WHEN REQ'D)
HEATED AIR
VENT
(WHEN REQ'D)
(TIE IN TO
NEAREST
APPLICABLE
J-BOX)
XWA11V
WEISS
ALARM
J-BOX
EXTERIOR
J-BOX
PROBE
VIEWPORT
(WHEN REQ'D)
J-BOX
(WHEN REQ'D)
LIGHT BASE
(WHEN REQ'D
BY OTHERS)
J-BOX
LIGHT(S)
(WHEN REQ'D)
GRAY/RED
PURPLE
BLUE
GRAY/BLACK
GRAY/GREEN
9V BATTERY
BACK-UP
(OPTIONAL)
BLACK
WHITE
J-BOX
MAIN DOOR SECTION
REMOTED XWA11V
WEISS ALARM(S)
(WHEN REQ'D)
EXTERIOR
J-BOX
PURPLE
BLUE
WHITE
BLACK
HEATER WIRE
(WHEN REQ'D)
RHEOSTAT
SWITCH
(WHEN REQ'D)
HEATED AIR
VENT
(WHEN REQ'D)
(TIE IN TO
NEAREST
APPLICABLE
J-BOX)
VIEWPORT
(WHEN REQ'D)
J-BOX
(WHEN REQ'D)
RED (FROM MAIN DOOR SECTION)
BLACK (FROM MAIN)
WHITE (FROM MAIN)
GROUND
J-BOX
(BY OTHERS)
LIGHT BASE
(WHEN REQ'D
BY OTHERS)
J-BOX
LIGHT(S)
(WHEN REQ'D)
J-BOX
(WHEN REQ'D)
LIGHT BASE
(WHEN REQ'D)
LIGHT(S)
(WHEN REQ'D)
J-BOX
ADDITIONAL DOOR SECTION(S)
LIGHTS
RELAY
RED FROM SWITCH
BLACK FROM MAIN POWER
WHITE FROM MAIN POWER
GROUND
INSTALLATION ELECTRICIAN IS
RESPONSIBLE FOR INCLUDING
AN APPROPRIATELY SIZED
RELAY WHEN THE LOAD ON THE
SWITCH EXCEEDS ITS RATING.
NOTE: LIGHT MANAGEMENT FOR ALL
COMPARTMENTS TYPICALLY
CONTROLLED BY PRIMARY ALARM ONLY.
PROBE TO ADDITIONAL COMPARTMENT
GRAY/BLACK
GRAY/GREEN
®
PEPI
SNAP DISC THERM
(WHEN REQ'D)
PEPI
SNAP DISC THERM
(WHEN REQ'D)
LIGHT CONNECTIONS FOR REMOTED ALARMS
MAGNETIC CONTACTS ON MULTIPLE DOORS WIRED TO ONE ALARM
MAGNETIC
SENSOR
DOOR 1
MAIN POWER
MAGNETIC
SENSOR
DOOR 2
NO ALARM
(REMOTED TO 1)
MAGNETIC
SENSOR
DOOR 3
NO ALARM
(REMOTED TO 1)
ALARM
HIDDEN LINES DENOTE
FIELD WIRING.
9V BATTERY
BACK-UP
(OPTIONAL)
GRAY/RED
EXTEND TO ADDITIONAL DOOR SECTION
LIGHT BASE
(WHEN REQ'D)
J-BOX
SENSOR
FIELD WIRE
BLACK
BLACK
BLACK
BLACK
SENSOR
WHITE
WHITE
WHITE
WHITE
BLACK
WHITE
GROUND
BLACK
WHITE
J-BOX
(BY OTHERS)
MAIN DOOR SECTION
(MAIN POWER IN)
XWA11V
WEISS
ALARM
EXTERIOR
J-BOX
PROBE
GRAY/RED
PURPLE
BLUE
GRAY/BLACK
GRAY/GREEN
BLACK
WHITE
J-BOX
MAIN DOOR SECTION
REMOTED XWA11V
WEISS ALARM(S)
(WHEN REQ'D)
EXTERIOR
J-BOX
GRAY/RED
PURPLE
BLUE
WHITE
BLACK
GRAY/BLACK
GRAY/GREEN
NOTE: THIS DIAGRAM IS FOR THE ALARM
PORTION ONLY. THE LIGHT MANAGEMENT IS
CONTROLLED BY A SWITCH. DOOR
ACCESSORIES ARE ON SWITCH WIRE HARNESS.
®
HIDDEN LINES DENOTE
FIELD WIRING.
PROBE TO ADDITIONAL COMPARTMENT
9V BATTERY
BACK-UP
(OPTIONAL)
EXTEND TO ADDITIONAL DOOR SECTION
9V BATTERY
BACK-UP
(OPTIONAL)
J-BOX
BLACK
BLACK
BLACK
BLACK
SENSOR
WHITE
WHITE
12
3
4
7
8
11
13
14
18
19
12
XW
A11V
XW
A11V_WIRING_FOR_MULTI_DOOR_SWITCH_MM_07_05_11
DOOR #1
DOOR #2
DOOR #3
9 VOL
T
BATTERY
PANIC
SWITCH
(63010)
MDS
(63240)
MDS
(63240)
MDS
(63240)
WIRING MUL
TIPLE DOOR SWITCHES TO THE XWA11V
WALK-IN ALARM
IT IS POSSIBLE TO WIRED SEVERAL
DOOR SWITCHES TO ONE SINGLE XWA11V.
MAKE SURE THAT THE SWITCH IS USED
IN SERIES. WHEN ANY BREAK THE LINE THE
D.I. WILL BE TRIPPED.
HEATER WIRE
(WHEN REQ'D)
LIGHT BASE
(WHEN REQ'D)
RED
BLACK
WHITE
GROUND
BLACK
WHITE
J-BOX
(BY OTHERS)
MAIN DOOR SECTION
(MAIN POWER IN)
RHEOSTAT
SWITCH
(WHEN REQ'D)
HEATED AIR
VENT
(WHEN REQ'D)
(TIE IN TO
NEAREST
APPLICABLE
J-BOX)
MODULARM
75 LC
J-BOX
EXTERIOR
J-BOX
PROBE
VIEWPORT
(WHEN REQ'D)
J-BOX
(WHEN REQ'D)
LIGHT BASE
(WHEN REQ'D
BY OTHERS)
J-BOX
LIGHT(S)
(WHEN REQ'D)
RED
PURPLE
BLUE
J-BOX
IP-1
J-BOX
(OPTIONAL)
NOTE: IF MOTION DETECTOR IS USED
WITHOUT IP-1 SWITCH, PLACE IN DOOR
CONTACT J-BOX.
GRAY/BLACK
WHITE
GRAY/RED
YELLOW
WHITE
WHITE
BLACK
WHITE
MAIN DOOR SECTION
REMOTED
MODULARM 75 LC
(WHEN REQ'D)
EXTERIOR
J-BOX
WHITE
WHITE
J-BOX
TO ADDITIONAL DOOR SECTION
(WHEN REQ'D)
LIGHT(S)
(WHEN REQ'D)
LIGHTS
RELAY
RED FROM SWITCH
BLACK FROM MAIN POWER
WHITE FROM MAIN POWER
GROUND
INSTALLATION ELECTRICIAN IS
RESPONSIBLE FOR INCLUDING
AN APPROPRIATELY SIZED
RELAY WHEN THE LOAD ON THE
SWITCH EXCEEDS ITS RATING.
®
PEPI
SNAP DISC THERM
(WHEN REQ'D)
NOTE: LIGHT MANAGEMENT FOR ALL
COMPARTMENTS TYPICALLY
CONTROLLED BY PRIMARY ALARM ONLY.
LIGHT CONNECTIONS FOR REMOTED ALARMS
MAGNETIC CONTACTS ON MULTIPLE DOORS WIRED TO ONE ALARM
DOOR 1
MAIN POWER
MAGNETIC
SENSOR
DOOR 2
NO ALARM
(REMOTED TO 1)
MAGNETIC
SENSOR
DOOR 3
NO ALARM
(REMOTED TO 1)
ALARM
DOOR
DOOR
Y
R
W
B
MAGNETIC
SENSOR
HIDDEN LINES DENOTE
FIELD WIRING.
PROBE TO ADDITIONAL COMPARTMENT
EXTEND TO
ADDITIONAL DOOR
SECTION
HEATER WIRE
(WHEN REQ'D)
RHEOSTAT
SWITCH
(WHEN REQ'D)
HEATED AIR
VENT
(WHEN REQ'D)
(TIE IN TO
NEAREST
APPLICABLE
J-BOX)
VIEWPORT
(WHEN REQ'D)
J-BOX
(WHEN REQ'D)
RED (FROM MAIN DOOR SECTION)
BLACK (FROM MAIN)
WHITE (FROM MAIN)
GROUND
J-BOX
(BY OTHERS)
LIGHT BASE
(WHEN REQ'D
BY OTHERS)
J-BOX
LIGHT(S)
(WHEN REQ'D)
J-BOX
(WHEN REQ'D)
LIGHT BASE
(WHEN REQ'D)
LIGHT(S)
(WHEN REQ'D)
J-BOX
ADDITIONAL DOOR SECTION(S)
PEPI
SNAP DISC THERM
(WHEN REQ'D)
LIGHT BASE
(WHEN REQ'D)
J-BOX
SENSOR
FIELD WIRE
WHITE
WHITE
SENSOR
WHITE
WHITE
RED
BLACK
GREEN
RED
BLACK
GRAY/GREEN
GRAY/BLACK
WHITE
GRAY/RED
YELLOW
GRAY/GREEN
BLUE
PURPLE
BLACK
WHITE
GROUND
BLACK
WHITE
J-BOX
(BY OTHERS)
MAIN DOOR SECTION
(MAIN POWER IN)
MODULARM
75 LC
EXTERIOR
J-BOX
PROBE
PURPLE
BLUE
J-BOX
WHITE
WHITE
NOTE: THIS DIAGRAM IS FOR THE ALARM
PORTION ONLY. THE LIGHT MANAGEMENT IS
CONTROLLED BY A SWITCH. DOOR
ACCESSORIES ARE ON SWITCH WIRE HARNESS.
®
HIDDEN LINES DENOTE
FIELD WIRING.
SENSOR
WHITE
WHITE
IP-1
J-BOX
(OPTIONAL)
GRAY/BLACK
WHITE
GRAY/RED
YELLOW
RED
BLACK
GREEN
RED
BLACK
GRAY/GREEN
BLACK
WHITE
MAIN DOOR SECTION
REMOTED
MODULARM 75 LC
(WHEN REQ'D)
EXTERIOR
J-BOX
WHITE
WHITE
J-BOX
TO ADDITIONAL DOOR SECTION
(WHEN REQ'D)
PROBE TO ADDITIONAL COMPARTMENT
EXTEND TO
ADDITIONAL DOOR
SECTION
GRAY/BLACK
WHITE
GRAY/RED
YELLOW
GRAY/GREEN
BLUE
PURPLE
MD-1
MAGNETIC
CONTACT (MC-1)
TMP
MD
BW R Y DOOR
TEMP
SENSOR
GREEN
MODULARM CORP.
WWW.MODULARM.COM
BWRYBWRY
MC-1 CONTACTS CAN CONNECT INSIDE IP-1
75LC CONNECTIONS
D
O
O
R
#
1
ILLUMINATED PUSHBUTTON
D
O
O
R
#
2
D
O
O
R
#
3
MAGNETIC
CONTACT (MC-1)
MAGNETIC
CONTACT (MC-1)
(IP-1)
ILLUMINATED PUSHBUTTON
(IP-1)
ILLUMINATED PUSHBUTTON
WIRING DIAGRAM - 75LC WITH MULTIPLE
IP-1'S AND MAGNETIC CONTACTS.
MOTION DETECTOR (MD-1) ALSO SHOWN
FUNCTION: TO PROVIDE 3 AND 4 WAY LIGHT SWITCHING INSIDE
OF COMPARTMENT, DOOR AJAR, AND AUTOMATIC
LIGHTS-ON AT EACH DOOR.
*NOTE: ALL CONNECTIONS SHOWN ARE LOW
VOLTAGE USING RECOMMENDED INTER-CONNECT
WIRE: [22AWG,MULTI-CONDUCTOR,STRANDED]
PROVIDE SEPARATE CONDUIT FOR LOW VOLTAGE WIRING.
*
OCT. 15, 2010
(IP-1)
H
EATER WIRE
(WHEN REQ'D)
LIGHT BASE
(WHEN REQ'D)
LIGHT(S)
(WHEN REQ'D)
R
ED
BLACK
WHITE
GROUND
B
LACK
WHITE
RED
J-BOX
J-BOX
(BY OTHERS)
I
N/OUT
BUZZER
(WHEN REQ'D)
R
HEOSTAT
SWITCH
(WHEN REQ'D)
HEATED AIR
VENT
(WHEN REQ'D)
(TIE IN TO
NEAREST
APPLICABLE
J-BOX)
J
-BOX
(WHEN REQ'D)
J-BOX
V
IEWPORT
(WHEN REQ'D)
J
-BOX
(WHEN REQ'D)
L
IGHT BASE
(WHEN REQ'D
BY OTHERS)
J
-BOX
L
IGHT(S)
(WHEN REQ'D)
I
NDICATOR
NEUTRAL
LINE
3 WAY
SWITCHED
A
LARM
(WHEN REQ'D)
PEPI
SNAP DISC THERM
(WHEN REQ'D)
P
ROBE
A
LL ALARMS EXCEPT:
MODULARM 75 LC AND WEISS ALARMPAK
(SEE SEPARATE DIAGRAM)
H
IDDEN LINES DENOTE
FIELD WIRING.
S
WITCH/THERM
(1967-3)
E
XTERIOR J-BOX
L
IGHTS
R
ELAY
R
ED FROM SWITCH
B
LACK FROM MAIN POWER
WHITE FROM MAIN POWER
GROUND
INSTALLATION ELECTRICIAN IS
RESPONSIBLE FOR INCLUDING
AN APPROPRIATELY SIZED
RELAY WHEN THE LOAD ON THE
SWITCH EXCEEDS ITS RATING.
®
M
OTION SENSOR
(WHEN REQ'D)
H
EATER WIRE
(WHEN REQ'D)
LIGHT BASE
(WHEN REQ'D)
LIGHT(S)
(WHEN REQ'D)
R
ED
BLACK
WHITE
GROUND
RED (LIGHTS)
BLACK
WHITE
GROUND
YELLOW
BLUE
B
LACK
J-BOX
J-BOX
(BY OTHERS)
I
N/OUT
BUZZER
(WHEN REQ'D)
R
HEOSTAT
SWITCH
(WHEN REQ'D)
HEATED AIR
VENT
(WHEN REQ'D)
(TIE IN TO
NEAREST
APPLICABLE
J-BOX)
J
-BOX
(WHEN REQ'D)
J-BOX
H
EATER WIRE
(WHEN REQ'D)
LIGHT BASE
(WHEN REQ'D)
LIGHT(S)
(WHEN REQ'D)
BLACK
WHITE
YELLOW
J-BOX
R
HEOSTAT
SWITCH
(WHEN REQ'D)
HEATED AIR
VENT
(WHEN REQ'D)
(TIE IN TO
NEAREST
APPLICABLE
J-BOX)
RED
J
-BOX
(WHEN REQ'D)
J-BOX
B
LUE
J
-BOX
LIGHT BASE
(WHEN REQ'D)
(BY OTHERS)
J
-BOX
(BY OTHERS)
V
IEWPORT
(WHEN REQ'D)
J
-BOX
(WHEN REQ'D)
I
N/OUT
BUZZER
(WHEN REQ'D)
V
IEWPORT
(WHEN REQ'D)
J
-BOX
(WHEN REQ'D)
W
HITE
L
IGHT(S)
(WHEN REQ'D)
W
HITE
RED
I
NDICATOR
NEUTRAL
LINE
3 WAY
SWITCHED
Y
ELLOW
BLUE
A
LARM
(WHEN REQ'D)
PEPI
SNAP DISC THERM
(WHEN REQ'D)
P
ROBE
A
LARM
(WHEN REQ'D)
PEPI
SNAP DISC THERM
(WHEN REQ'D)
P
ROBE
A
LL ALARMS EXCEPT:
MODULARM 75 LC AND WEISS ALARMPAK
(SEE SEPARATE DIAGRAM)
H
IDDEN LINES DENOTE
FIELD WIRING.
MAIN DOOR SECTION
(MAIN POWER IN)
EXTERIOR J-BOX
ENDING DOOR SECTION
EXTERIOR J-BOX
S
WITCH/THERM
(1967-3)
3
-WAY
SWITCH
(1908-603)
L
IGHTS
R
ELAY
R
ED FROM SWITCH
B
LACK FROM MAIN POWER
WHITE FROM MAIN POWER
GROUND
INSTALLATION ELECTRICIAN IS
RESPONSIBLE FOR INCLUDING
AN APPROPRIATELY SIZED
RELAY WHEN THE LOAD ON THE
SWITCH EXCEEDS ITS RATING.
N
OTE: MAIN DOOR SECTION HAS MAIN POWER.
ENDING DOOR SECTION GETS POWER FROM MAIN DOOR SECTION.
®
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20

Kolpak Walk-in Product information

Category
Motorcycle Accessories
Type
Product information

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI