Campbell HUB-SDM8 Owner's manual

Category
Network switches
Type
Owner's manual

This manual is also suitable for

HUB-SDM
8
1/08
Copyright © 2004-2008
Campbell Scientific, Inc.
Warranty and Assistance
The HUB-SDM8 is warranted by CAMPBELL SCIENTIFIC, INC. to be free
from defects in materials and workmanship under normal use and service for
twelve (12) months from date of shipment unless specified otherwise.
Batteries have no warranty. CAMPBELL SCIENTIFIC, INC.'s obligation
under this warranty is limited to repairing or replacing (at CAMPBELL
SCIENTIFIC, INC.'s option) defective products. The customer shall assume
all costs of removing, reinstalling, and shipping defective products to
CAMPBELL SCIENTIFIC, INC. CAMPBELL SCIENTIFIC, INC. will
return such products by surface carrier prepaid. This warranty shall not apply
to any CAMPBELL SCIENTIFIC, INC. products which have been subjected
to modification, misuse, neglect, accidents of nature, or shipping damage. This
warranty is in lieu of all other warranties, expressed or implied, including
warranties of merchantability or fitness for a particular purpose. CAMPBELL
SCIENTIFIC, INC. is not liable for special, indirect, incidental, or
consequential damages.
Products may not be returned without prior authorization. The following
contact information is for US and International customers residing in countries
served by Campbell Scientific, Inc. directly. Affiliate companies handle
repairs for customers within their territories. Please visit
www.campbellsci.com to determine which Campbell Scientific company
serves your country. To obtain a Returned Materials Authorization (RMA),
contact CAMPBELL SCIENTIFIC, INC., phone (435) 753-2342. After an
applications engineer determines the nature of the problem, an RMA number
will be issued. Please write this number clearly on the outside of the shipping
container. CAMPBELL SCIENTIFIC's shipping address is:
CAMPBELL SCIENTIFIC, INC.
RMA#_____
815 West 1800 North
Logan, Utah 84321-1784
CAMPBELL SCIENTIFIC, INC. does not accept collect calls.
HUB-SDM8 Table of Contents
PDF viewers note: These page numbers refer to the printed version of this document. Use
the Adobe Acrobat® bookmarks tab for links to specific sections.
1. Introduction..................................................................1
2. HUB-SDM8 Specifications ..........................................1
3. General .........................................................................1
4. Installation and Wiring................................................2
4.1 Wiring SDM Devices and Power Wires for Daisy-Chain........................2
5. HUB-SDM5....................................................................3
6. Generic Junction Box..................................................3
7. Maintenance.................................................................4
Figures
1. HUB-SDM8 in a Daisy-Chain Network.....................................................2
2. HUB-SDM8 in a Daisy-Chain Network — Bottom View .........................3
i
This is a blank page.
HUB-SDM8
1. Introduction
The HUB-SDM8 is an 8-channel hub for SDM peripherals and power
connectors, and is used to daisy-chain multiple sets of SDM (Synchronous
Device for Measurement) devices to a single Campbell Scientific, Inc.
datalogger, as well as run multiple power connectors using a 16 AWG wire.
The HUB-SDM8 is comprised of an environmental enclosure with eight
compression fittings (two larger for 16 AWG power wires) and eight terminal
strips. The HUB-SDM8 can also be used as a generic junction box, or as a
HUB-SDM5.
2. HUB-SDM8 Specifications
Terminal Strips:
Three spring-loaded “guillotine” connections per terminal; two terminals in
common through a jumper creates eight banks
Operating Temperature:
-55°C to +85°C
Operating Humidity:
Noncondensing 0% – 95%
Dimensions:
Length: 17.8 cm (7.0”)
Width: 19.7 cm (7.75”)
Depth: 13.3 cm (5.25”)
Weight:
0.88 kg (1.95 lbs)
3. General
Inside the HUB-SDM8 enclosure are eight pairs of spring-loaded "guillotine"
terminal strips, which provide connection points for individual wires. A small
screwdriver is included to open the guillotines for wire entry. These terminal
strips are mounted on a DIN-rail and an orange end cap separates each pair.
Each pair of terminal strips is connected to each other by means of a jumper,
and is used to connect up to six wires to each other.
1
HUB-SDM8
4. Installation and Wiring
A U-bolt is used to mount the HUB-SDM8 to a 1.25 inch NPT pipe.
The spring-loaded guillotines are opened with a small flat blade (2.5 x 50 mm)
screwdriver (p/n 8125). Orient the screwdriver blade so that the blade edge is
perpendicular to the orange separators. Gently insert the small flat blade
screwdriver into the square slot located next to the circular wire port until it
bottoms out. For the cluster of four wire ports located on the left hand side of
the HUB-SDM8, the guillotine release slot is located to the right of the wire
port. For the wire ports on the right hand side of the HUB-SDM8, the
guillotine release slot is located to the left of the wire port. Once the
screwdriver has been completely inserted and has bottomed out, firmly press
the screwdriver down until the guillotine snaps open. Insert and hold the wire
as the screwdriver is removed.
4.1 Wiring SDM Devices and Power Wires for Daisy-Chain
Before connecting the cable to the terminals, strip the wire insulation back to
expose 1/4 inch of bare wire. Feed the cable through the bulkhead fitting.
Neatly separate the wires, and connect them, using the technique described in
section 4 above. The figures below show how two SDM devices (CSAT3 and
LI-7500) and their power wires are connected within a daisy-chain network.
SDM In
FIGURE 1. HUB-SDM8 in a Daisy-Chain Network
CSAT3 SDM
CSAT3 Powe
r
LI-7500 SDM
LI-7500 Powe
r
Power In
SDM Out
Power Out
2
HUB-SDM8
To CSAT3 Power
To CSAT3 SDM
To LI-7500 SDM
To LI-7500 Power
SDM In
Power In SDM Out Power Out
FIGURE 2. HUB-SDM8 in a Daisy-Chain Network — Bottom View
5. HUB-SDM5
The HUB-SDM8 can provide the same function as the HUB-SDM5, which is a
5-channel hub for SDM peripherals. Use the supplied plugs to seal the unused
bulkhead fittings to use the HUB-SDM8 to connect multiple SDM devices to a
single Campbell Scientific, Inc. datalogger. Please refer to the HUB-SDM5
manual for connecting multiple SDM devices to a datalogger, using the
HUB-SDM8.
6. Generic Junction Box
The HUB-SDM8 can be used as a generic junction box. In its default
configuration, six eight-conductor cables can be connected to each other.
Three sixteen-conductor cables can be connected to each other by removing the
jumper between the terminal strips. Use a small screwdriver to pry the jumper
out.
3
HUB-SDM8
4
7. Maintenance
There are no user-serviceable parts in the HUB-SDM8. Make sure that all
unused bulkhead fittings are sealed with a plug and that the lid is tightly
fastened.
This is a blank page.
Campbell Scientific Companies
Campbell Scientific, Inc. (CSI)
815 West 1800 North
Logan, Utah 84321
UNITED STATES
www.campbellsci.com
Campbell Scientific Africa Pty. Ltd. (CSAf)
PO Box 2450
Somerset West 7129
SOUTH AFRICA
www.csafrica.co.za
Campbell Scientific Australi
a Pty. Ltd. (CSA)
PO Box 444
Thuringowa Central
QLD 4812 AUSTRALIA
www.campbellsci.com.au
Campbell Scientific do Brazil Ltda. (CSB)
Rua Luisa Crapsi Orsi, 15 Butantã
CEP: 005543-000 São Paulo SP BRAZIL
www.campbellsci.com.br
Campbell Scientific Canada Corp. (CSC)
11564 - 149th Street NW
Edmonton, Alberta T5M 1W7
CANADA
www.campbellsci.ca
Campbell Scientific Ltd. (CSL)
Campbell Park
80 Hathern Road
Shepshed, Loughborough LE12 9GX
UNITED KINGDOM
www.campbellsci.co.uk
Campbell Scientific Ltd. (France)
Miniparc du Verger - Bat. H
1, rue de Terre Neuve - Les Ulis
91967 COURTABOEUF CEDEX
FRANCE
www.campbellsci.fr
Campbell Scientific Spain, S. L.
Psg. Font 14, local 8
08013 Barcelona
SPAIN
www.campbellsci.es
Please visit www.campbellsci.com to obtain contact information for your local US or International representative.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10

Campbell HUB-SDM8 Owner's manual

Category
Network switches
Type
Owner's manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI