ADATIS UP series Mounting And Installation Manual

Category
PowerLine network adapters
Type
Mounting And Installation Manual
Adatis GmbH & Co.KG page 1 of 8
UP-Series
Mounting and installation manual
Version
0.1
Autor
cschardt
Datum
20.12.2018
Log
V0.1
Adatis GmbH & Co.KG page 2 of 8
Table of contents
1! SCOPE OF DELIVERY 3!
2! CONNECTIONS AND INTERFACES 3!
2.1! Connections and interfaces version Ethernet 4!
2.2! Connections and interfaces version HV/PLC 5!
2.3! Connections and interfaces version NV/PLC 6!
3! GETTING STARTED 7!
4! MOUNTING 7!
Adatis GmbH & Co.KG page 3 of 8
1 Scope of delivery
UP device including glass frame and board cover
1 or 2 RFID cards for opening the enrollment area
1 x connection cable (ETHERNET version only)
1 x Powerline Adapter (HV/PLC version only)
1x 2Wire Converter including connector plug (only for NV/PLC version)
2 Connections and Interfaces
All connections and interfaces are located on the rear-mounted board of the device.
Depending on the version ordered, various options are available for supplying the flush-
mounted unit with power.
Power supply
PoE
(alternatively 6-56V)
-
-
110/230 V
-
-
48V bell wire
-
-
Connections and
Interfaces
Relay
Trigger input 1
Trigger input 2
5V output
100mA max.
Wiegand Output
ETHERNET HV/PLC NV/PLC
Adatis GmbH & Co.KG page 4 of 8
2.1 Connections and interfaces version Ethernet
The Ethernet version of the UP series is standardly powered by PoE. For this, the supplied
cable is connected to a PoE switch or a PoE injector. If only an Ethernet switch without PoE
ports is available, power can alternatively be supplied via a plug-in power supply (6-56 V).
A relay (e.g. for switching a door opener) and two trigger inputs are available.
In addition, the device has a Wiegand output, which is intended for connection to door
controllers or similar.
CAT5e cable
connection to Ethernet port
PoE ports
Ethernet ports
INPUT
GND
IN2
IN1
RELAY
NO NC COM
ALTERNATIVELY
6-56V
ETHERNET
TX+
TX-
RX+
RX
GND
5V Dat0 Dat1 GND
100mA
max
OUTPUT / WIEGAND
Adatis GmbH & Co.KG page 5 of 8
2.2 Connections and interfaces version HV/PLC
The HV/PLC version of the UP series is standardly powered by a 110/230V power line. The
wires of the power cable are connected to the 110/230V socket of the UP unit. A connection
to the network is established via the supplied powerline adapter.
A relay (e.g. for switching a door opener) and two trigger inputs are available.
In addition, the device has a Wiegand output, which is intended for connection to door
controllers or similar.
CAT5e cable
connection to Ethernet port
CAT5e cable
connection Ethernet Port
Power cable 230V AC
connection to power socket
Ethernet ports
5V Dat0 Dat1 GND
100mA
max
OUTPUT / WIEGAND
RELAY
NO NC COM
110/230V
INPUT
GND
IN2
IN1
Adatis GmbH & Co.KG page 6 of 8
2.3 Connections and interfaces version NV/PLC
The NV/PLC version of the UP series is standardly powered by a 48V bell wire. The wires of
the 2wire line are connected to the 2wire socket of the UP unit. A connection to the network
is established via the supplied converter box, which must be connected to a PoE port.
A relay (e.g. for switching a door opener) and two trigger inputs are available.
In addition, the device has a Wiegand output, which is intended for connection to door
controllers or similar.
PoE ports
Ethernet ports
CAT5e cable
connection to Ethernet port
Bell wire 48-56V DC
connection to 2Wire converter
INPUT
GND
IN2
IN1
RELAY
NO NC COM
2wire
5V Dat0 Dat1 GND
100mA
max
OUTPUT / WIEGAND
Adatis GmbH & Co.KG page 7 of 8
3 Getting started
The terminals of the UP series are configured via the WEB interface. In order to enroll users
at the terminals, they must first be created in the personnel database of the WEB interface
by entering a PIN code.
Default IP-address of the terminal:
192.168.2.81
Default Login data for the web interface:
Username: admin
Password: 1234
Opening the enrollment area of the UP terminals
Enrollment area for face recognition: Enrollment card green (FaceUP only)
Enrollment area for RFID cards: Enrollment card red
Further information about operation and configuration of the UP series can be found in the
instructions on our homepage www.adatis.com for download.
4 Mounting
The UP series is designed for installation in 55 mm standard switch programs and is
intended for indoor use.
Recommended mounting height: approx. 164.5 cm centre of flush-mount box
ca. 164,5 cm
approx. 164.5 cm
Adatis GmbH & Co.KG page 8 of 8
A wall opening with a diameter of approx. 67 mm has to be prepared. In the flush-mount
box, a suitable opening for cable entry must be provided. After fixing the flush-mount box,
the UP module is screwed to the flush-mount box without frame (this must be removed
beforehand). Corresponding holes are provided in the printed circuit board for this purpose.
Finally, the glass frame is reattached to the module.
Schritt 1 Schritt 2 Schritt 3 Schritt 4
step 3
step 2
step 1
step 4
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

ADATIS UP series Mounting And Installation Manual

Category
PowerLine network adapters
Type
Mounting And Installation Manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI