Installation Instructions
Dear Customer,
Congratulations on purchasing your new STEINEL
LED floodlight projector and thank you for the
confidence you have shown in us. You have chosen
a high-quality product that has been manufactured,
tested and packed with the greatest care.
GB
Safety Warnings
■ Disconnect the power supply before attempting
any work on the light.
■ During installation, the electrical wiring being con-
nected must be dead. Therefore, switch off the
power first and use a voltage tester to make sure
the wiring is off circuit.
■ Installation of these light involves work on the
mains power supply; this means it must be carried
out professionally in accordance with national
wiring regulations and electrical operating
conditions (
D
-VDE 0100,
A
-ÖVE/ÖNORM
E 8001-1,
-SEV 1000)
Please familiarise yourself with these instructions
before attempting to install the light because pro-
longed, reliable and trouble-free operation will only
be ensured if it is fitted and used properly.
We hope your new STEINEL LED floodlight projector
will bring you lasting pleasure.
■ Do not install the light on normally flammable
surfaces.
■ Suitable for indoor and outdoor use.
■ The sensor-switched LED floodlight is only
intended for wall mounting and not for ceiling
mounting.
■ The housing gets warm while the floodlight is
switched ON. Only adjust the angle of the LED
head once it has cooled down.
■ Do not look into the LED light at short
range or for any prolonged period
(> 5 min.). You could damage your retina.
Principle
The LED floodlight projector's photoelectric sensor
system brings new radiance to outdoor advertising.
This sensor system measures ambient brightness and
automatically switches the light ON at dusk and, with
a variety of switching options, automatically OFF
again at dawn.
System Components
Wall mount with power supply unit
Sealing plug
LDR sensor
LED floodlight head
Heat sink
Lamp arm with cover
Lamp arm adjuster
Note: Master/slave
Floodlight head swivel range
Programme selector
1 Slave mode
2 Twilight mode
3 Night economy mode
Twilight setting
Even illumination of surfaces lit
Drainage hole
Mains connection, concealed wiring
Mains connection, surface wiring
I
II
Installation
The mains supply lead is a 3-core cable.
L = phase conductor (usually black, brown or grey)
N = neutral conductor (usually blue)
PE = protective-earth conductor (green/yellow)
Functions
Twilight setting
(response threshold)
(Factory setting:
daylight operation 100 lux)
Programmes (Factory setting: programme 2)
Important: Getting the cable connections crossed
will produce a short circuit in the light or in your fuse
box. In this case, you must identify the individual
cables and re-connect them. An appropriate mains
switch for switching the light ON and OFF can be
installed in the mains lead.
1 Slave mode:
The floodlight is switched ON by another flood-
light in P2 or P3. It can also be switched ON and
OFF manually or by timer.
2 Twilight mode:
Light ON as from light-level setting selected.
3 Night economy mode:
Light ON as from light-level setting selected and
OFF for 3 hours one hour after midnight. Then
ON until the light-level setting selected.
2 – 100 lux
Note: Master/slave
To avoid disturbing influences at the LDR sensor
(e.g. from wire-connected floodlights (slave), we
recommend installing the master floodlight outermost
in all cases.
This way, the light measured at LDR sensor is a true
reading.
The sensor's response threshold can be infinitely
varied from 2 – 100 lux.
Control dial set to =
daylight operation (approx. 100 lux)
Control dial set to =
night-time operation approx. 2 lux.
GB
Note on night economy function:
The night economy mode always ends in the early
hours of the morning between approx. 4 and 5 a.m.
After then, the light switches ON again automatically
when it's dark if the morning hours option is set to
ON. The sensor contains no integrated clock, the
middle of the night is only determined by the length of
the dark phases. To work perfectly, this means it is
important for the floodlight to be permanently connec-
ted to the power supply during this period. The flood-
light is switched ON all the time during the first night
(calibration phase). Values remain saved even in the
event of mains power failure. We do not recommend
interrupting the power supply in the programme. The
values are determined over several nights which
means that in the event of any fault occurring the
floodlight should be observed over several nights
to see whether the switch-OFF time moves towards
midnight.
approx.
2h
approx. 3h
OFF
approx.
2h
OFF
OFF