Heat & Glo Campfire User manual

Category
Fireplaces
Type
User manual

This manual is also suitable for

1
Hearth & Home Technologies • CFL-18/24/30-C, CFL-24-IPI • 526-910 Rev. X • 1/22
MODELS:
NATURAL GAS PROPANE
CFL-18NG-C CFL-18LP-C
CFL-24NG-C CFL-24LP-C
CFL-30NG-C CFL-30LP-C
CFL-24NG-IPI CFL-24LP-IPI
• Donotstoreorusegasolineorotheram-
mable vapors and liquids in the vicinity of
thisoranyotherappliance.
What to do if you smell gas
- Donottrytolightanyappliance.
- Donottouchanyelectricalswitch.Donot
useanyphoneinyourbuilding.
- Immediatelycallyourgassupplierfroma
neighbor’sphone.Followthegassuppli-
er’sinstructions.
- Ifyoucannotreachyourgassupplier,call
theredepartment.
• Installationandservicemustbeperformed
byaqualiedinstaller,serviceagency,orthe
gassupplier.
WARNING: If the information in these
instructions is not followed exactly, a re
or explosion may result causing property
damage, personal injury, or death.
Owners Manual
Installation and Operation
DO NOT DISCARD THIS MANUAL
CAUTION
• Leave this manual with
partyresponsibleforuse
andoperation.
DO NOT
DISCARD
• Important operating
and maintenance
instructionsincluded.
• Read,understandandfollow
theseinstructionsforsafe
installationandoperation.
IntheCommonwealthofMassachusetts:
• Installationmustbeperformedbyalicensedplumber
orgastter.
• Thechimneyuedamper,whenusedwithgaslogs,
willbeweldedopenorcompletelyremoved.
• ACOdetectorshallbeinstalledintheroomwherethe
applianceisinstalled.
WARNING
HOT SURFACES!
Glassandothersurfacesarehotduring
operationANDcooldown.
Hot glass will cause burns.
• Donottouchglassuntilitiscooled
• NEVERallowchildrentotouchglass
• Keepchildrenaway
CAREFULLY SUPERVISE children in same room as
replace.
• Alertchildrenandadultstohazardsofhightemperatures.
High temperatures may ignite clothing or other ammable
materials.
• Keep clothing, furniture, draperies and other ammable
materialsaway.
Installation and service of this
appliance should be performed
byqualiedpersonnel.Hearth&
HomeTechnologiesrecommends
NFIcertiedprofessionals.
WARNING: This product and the fuels used to
operate this product (liquid propane or natural
gas),andtheproductsofcombustionofsuchfuels,can
expose you to chemicals including benzene, which is
known to the State of California to cause cancer and
reproductiveharm.Formoreinformationgoto:www.
P65Warnings.ca.gov.
Note: Theuseofathermostatisprohibitedinventedlog
installations.
Hearth & Home Technologies • CFL-18/24/30-C, CFL-24-IPI • 526-910 Rev. X • 1/222
Congratulations
Listing Label Information/Location
ModelName: ___________________________________________ Datepurchased/installed: __________________
SerialNumber: __________________________________________ Locationonappliance: ____________________
Dealershippurchasedfrom: _______________________________ DealerPhone: __________________________
Notes: _______________________________________________________________________________________
_____________________________________________________________________________________________
Readthismanualbeforeinstallingoroperatingthisappliance.
Pleaseretainthisowner’smanualforfuturereference.
We recommend that you record the following pertinent
information about your appliance.
GasInformation
SerialNumber
TypeofGas
Themodelinformationregardingyourspecicappliancecanbefoundon
theratingplateusuallylocatedinthecontrolareaoftheappliance.
Homeowner Reference Information
ModelNumber
for Not Not for use use with with solid solid fuel.fuel.
((Ne Ne doit doit pas pas entre entre utilise utilise avec avec un un combustible combustible solide).solide).
This This appliance appliance must must be be installed installed in in accordance accordance with with local local codes, codes, if if any; any; if if not, not, follow follow ANSI ANSI Z223.1Z223.1
in in the the USA USA or or CAN/CGA CAN/CGA B149 B149 installation installation codes. codes. (Installer (Installer l’appareil l’appareil selon selon les les codes codes ou ou reglementsreglements
locaux locaux ou, ou, en en l’absence l’absence de de tels tels reglements, reglements, selon selon les les codes codes d’installation d’installation CAN/CGA-B149.)CAN/CGA-B149.)
Type Type of of Gas Gas (Sorte (Sorte De De Gaz)Gaz)::
NNAATURALTURAL GASGAS
MADE MADE IN IN USAUSA
Minimum Minimum Permissible Permissible Gas Gas Supply Supply for for Purposes Purposes of of Input Input Adjustment.Adjustment.
Approved Approved Minimum Minimum (De (De Gaz) Gaz) AcceptableAcceptable0.00.0 in in w.c.w.c. (Po. (Po. Col. Col. d’eau)d’eau)
Maximum Maximum Pressure Pressure (Pression)(Pression) 0.00.0 in in w.c.w.c. (Po. (Po. Col. Col. d’eau)d’eau)
Maximum Maximum Manifold Manifold Pressure Pressure (Pression)(Pression) 0.00.0 in in w.c.w.c. (Po. (Po. Col. Col. d’eau)d’eau)
Minimum Minimum Manifold Manifold Pressure Pressure (Pression)(Pression) 0.00.0 in in w.c.w.c. (Po. (Po. Col. Col. d’eau)d’eau)
Model:Model:
(Modele):(Modele):
SerialSerial
(Serie):(Serie):
ANSI ANSI Z21XX-XXXX Z21XX-XXXX · · CSA CSA 2.XX-MXX 2.XX-MXX · · UL307BUL307B
XXXXXXXXXXXXXXXX
IN IN CANADACANADA
ALTITUDE:ALTITUDE:0-0000 0-0000 FT.FT.0000-0000FT.0000-0000FT.
MAX. MAX. INPUT INPUT BTUH:BTUH: 00,00000,000 00,00000,000
MIN. MIN. INPUT INPUT BTUH:BTUH: 00,00000,000 00,00000,000
ORIFICE ORIFICE SIZE:SIZE: #XXXXX#XXXXX #XXXXX#XXXXX XXXXXXXXXXXXXXXX
Total Total Electrical Electrical Requirements: Requirements: 000Vac, 000Vac, 00Hz., 00Hz., less less than than 00 00 AmperesAmperes
Hearth & Home Technologies
7571 215th Street West, Lakeville, MN 55044
CongratulationsonselectingaHearth&HomeTechnologies
gas replace, an elegant and clean alternative to wood
burningreplaces.Thegasreplaceyouhaveselected
isdesignedtoprovidetheutmostinsafety,reliability,and
eciency.
Astheownerofanewreplace,you’llwanttoreadand
carefully follow all of the instructions contained in this
ownersmanual.Payspecialattentiontoallcautionsand
warnings.
This owners manual should be retained for future
reference. We suggest that you keep it with your other
importantdocumentsandproductmanuals.
Theinformationcontainedinthisownersmanual,unless
noted otherwise, applies to all models and gas control
systems.
YournewHearth&HomeTechnologiesgasreplacewill
giveyouyearsofdurableuseandtrouble-freeenjoyment.
Welcome to the Hearth & HomeTechnologies family of
replaceproducts!
3
Hearth & Home Technologies • CFL-18/24/30-C, CFL-24-IPI • 526-910 Rev. X • 1/22
=Containsupdatedinformation.
Table of Contents
1 Introduction
A. ApplianceCertication............................ 4
B. BTUSpecications............................... 6
C. HighAltitudeInstallation........................... 6
2 Getting Started
A. InspectApplianceandComponents.................. 7
B. Installation ..................................... 7
3 Operating Guidelines and Maintenance Instructions
A. BeforeLightingAppliance......................... 10
B. Maintenance................................... 10
4 Troubleshooting
A. StandingPilotIgnitionSystem..................... 13
B. IntelliFire®IgnitionSystem........................ 15
5 Reference Materials
A. ServiceParts.................................. 17
B. LimitedLifetimeWarranty......................... 22
C. ContactInformation............................. 24
Hearth & Home Technologies • CFL-18/24/30-C, CFL-24-IPI • 526-910 Rev. X • 1/224
Thislogsetistobeinstalledonlyinasolid-fuelburning
replacewithaworkingueandoneconstructedofnon-
combustiblematerial.Theminimumpermanentventopen-
ingprovidedbythereplacechimneydampertoventthe
ueproductsmustnotbelessthan51squareinches(328
cm2).ThechimneydamperMUSTbexedinamannerto
maintaintheminimumpermanentventopening.Thismay
beaccomplishedbyfasteningthedamperstopclamppro-
videdtotheedgeofthedampertopreventitsclosing.
Theinstallation,includingprovisionsforcombustionand
ventilationair,mustconformwiththeNationalFuelGas
CodeANSIZ223.1(intheUnitedStates),theCAN/CGA
B-149InstallationCode(inCanada)andapplicablelocal
buildingcodes.
Thesemodelscanbeinstalledinabedroom(intheUnited
States)whichhasatotalvolumeofunconnedspaceap-
propriatetotheparticularinstallation.RefertotheNational
FuelGasCodeANSIZ223.1/NFPA54-(current edition).
TheUniformMechanicalCode(currentedition),andLocal
BuildingOcialsfortheoptionsallowedinobtainingan
eectivebedroomvolumeofunconnedspace.
Alwayskeeptheapplianceareaclearandfreefromcom-
bustiblematerials,gasoline,andotherammablevapors
andliquids.
WARNING! Risk of Fire, Explosion or Electric Shock!
DO NOT use this appliance if any part has been under
water. Call a qualied service technician to inspect the
appliance and to replace any part of the control system
and/or gas control which has been under water.
A. Appliance Certication
WARNING
FireRisk
AsphyxiationRisk
ThesegaslogsetshavebeentestedandlistedintheU.S.
inaccordancewithANSI Z21.60b-2004.Theyhavebeen
listedbyUnderwritersLaboratoriesInc.forinstallationand
operationintheUnitedStatesandCanadaasdescribedin
theseInstallationandOperationInstructions.Allcompo-
nentsareUL,AGA,CGAorCSAsafetycertied.
Checkwithyourlocalbuildingcodeagencypriortoinstall-
ingthisappliancetoensurecompliancewithlocalcodes,
includingtheneedforpermitsandfollow-upinspections.In
theabsenceoflocalcodes,complywiththeNationalFuel
GasCode,ANSIZ223.1-LatestEditionintheU.S.Ifany
assistanceisrequiredduringinstallation,pleasecontact
yourlocaldealer.
CAUTION
Checktheconstructionofthereplacebeforeinstallingthe
gaslogset.Theareaoftheueshouldnotbelessthan1/11
theareaofthereplaceopening.Non-airtightglassdoors
shouldbeinstalled on thereplaceif the areaofthe ue
islessthan1/11theareaofthereplaceopening.Airtight
doorsmustneverbeusedwiththisgaslogset.
FireRisk
• THISUNITISNOTFORUSEWITHSOLID
FUEL. Solid fuels shall not be burned in a
fireplace where a decorative appliance is
installed.Failuretofollowtheseinstructions
willresultinare.
WARNING
1 1 Introduction
GasLogSetsareDecorativeGasAppliancesforInstalla-
tioninaSolid-fuelBurningFireplace.Minimumreplace
sizesforthesemodelsisshowninFigure1.
MODELS: CFL-18NG/LP-C, CFL-24NG/LP-C,
CFL-30NG/LP-C, CFL-24NG/LP-IPI
LABORATORY: Underwriters Laboratories, Inc. (UL)
TYPE: Decorative Gas Appliances for Installation in
Solid-Fuel Burning Fireplaces
STANDARD: ANSI Z21.60b-2004 CSA 2.26b-2004
This log set must NOT be installed in an unvented
appliance.
• Openthechimneydampertoitsfullyopenpositionwhen
burningthisgaslogset.
• Logsmustneverbeburnedwithouttheuedamperinthe
fullopenposition. Failure to dosois dangerous to your
healthandvoidsallwarranties.
• Allgasappliancesproducesomecarbonmonoxidewhen
operated.  Carbon monoxide is a colorless, odorless,
poisonous gas. Adequate provisions must be made to
providecombustionairforthisgaslogset.Ifoutsideairis
notaccessedbythereplace,itmaybenecessarythatan
additionalcombustionairsourcebeprovided.
5
Hearth & Home Technologies • CFL-18/24/30-C, CFL-24-IPI • 526-910 Rev. X • 1/22
MODEL CFL-18-C
 MINIMUMFIREPLACESIZE
FRONTWIDTH:231/2”(750mm)
 REARWIDTH:191/2”(521mm)
 DEPTH :131/2”(331mm)
 HEIGHT :22”(508mm)
23 1/2
MODEL CFL-24-C
TOPVIEW
 MINIMUMFIREPLACESIZE
FRONTWIDTH:271/2”(750mm)
 REARWIDTH:22”(521mm)
 DEPTH :151/2”(331mm)
HEIGHT  :22”(508mm)
151/2
27 1/2
22
TOPVIEW
13 1/2
19 1/2
TOPVIEW
 MINIMUMFIREPLACESIZE
FRONTWIDTH:30”(750mm)
 REARWIDTH:24”(521mm)
 DEPTH :151/2”(331mm)
HEIGHT  :22”(508mm)
151/2
30
24
MODEL CFL-30-C
Figure1.MinimumFireplaceSizesforCFL-18/24/30-C
Hearth & Home Technologies • CFL-18/24/30-C, CFL-24-IPI • 526-910 Rev. X • 1/226
C. High Altitude Installation
NOTICE: If the heating value of the gas has been reduced,
these rules do not apply. Check with your local gas utility
or authorities having jurisdiction.
Wheninstallingabove2000feetelevation:
• IntheUSA:Reduceinputrate4%foreach1000feet
above2000feet.
• In CANADA: Reduce input rate 10% for elevations
between 2000 feet  and 4500 feet.Above 4500 feet,
consultlocalgasutility.
Checkwithyourlocalgasutilitytodetermineproperorice
size.
B. BTU Specications
Models
(U.S. or Canada) Input BTU/h
Orice
Size (DMS)
CFL-18NG-C
CFL-24NG-C
CFL-30NG-C
CFL-24NG-IPI
US
(0-2000 FT) 60,000 7-1.55mm
CANADA
(2000-4500 FT) 54,000 #25DMS
CFL-18LP-C
CFL-24LP-C
CFL-30LP-C
CFL-24LP-IPI
US
(0-2000 FT) 60,000 2.30mm
CANADA
(2000-4500 FT) 54,000 #43DMS
7
Hearth & Home Technologies • CFL-18/24/30-C, CFL-24-IPI • 526-910 Rev. X • 1/22
Thesemodelscontaincompletegas-burner,grate(s),and
logcomponentsneeded.Usecautionwhenhandlinglogs
toavoiddamage.Positionthegas-burnerassemblytothe
rearofthereplace.Oncefullyassembled,thefrontlog
willextendforwardoftheburnerassembly.
2 2 Getting Started
Note:Thegassupplylineshouldbepurgedofanytrapped
airpriortotherstringoftheunit.
NOTICE: This installation must conform with local codes.
In the absence of local codes you must comply with the
National Fuel Gas Code, ANSI Z223.1-latest edition in
the U.S.A. and the CAN/CGA B149 Installation Codes in
Canada.
CAUTION! When installing this log set in a factory built
replace, be certain to consult the replace installation
manual. ALL knockouts in the replace through which the
gas supply line is run MUST be resealed with insulation
after the gas line is in place.
WARNING! Risk of Asphyxiation! Improper positioning
of log set may allow spillage and prohibit proper draft.
Position the log set as close to the back of the replace as
possible.
A. Inspect Appliance and Components
• Carefullyremovetheapplianceandcomponentsfrom
thepackaging.
• Ifpackagedseparately,thelogsetandappliancegrate
mustbeinstalled.
• Reporttoyourdealeranypartsdamagedinshipment,
particularlytheconditionoftheglass.
Read all of the instructions before starting the instal-
lation. Follow these instructions carefully during the
installation to ensure maximum safety and benet.
WARNING! Risk of Fire or Explosion! Damaged parts
could impair safe operation. DO NOT install damaged, in-
complete or substitute components. Keep appliance dry.
Hearth&HomeTechnologiesdisclaimsanyresponsibilityfor,
andthewarrantywillbevoidedby,thefollowingactions:
• Installation and use of any damaged appliance or vent
systemcomponent.
• Modicationoftheapplianceorventsystem.
• Installation other than as instructed by Hearth & Home
Technologies.
• Improperpositioningofthegaslogsortheglassdoor.
• Installationand/oruseofanycomponentpartnotapproved
byHearth&HomeTechnologies.
Any such action may cause a re hazard.
B. Installation
1. GAS CONNECTION
a.Runpropersizegaslineintoreplace.A1/2inch(13mm)
gasline,witha3/8inch(10mm)reductionforhook-up,is
usuallysucientfortheGasLogset;however,iftherun
isunusuallylong,alargerlinemayberequired.Contact
yourlocalgascompanyorDepartmentofBuildingand
Safetyifthereareanyquestions.
b.Optimumapplianceperformancerequiresproperinput
pressures.Pressurerequirementsare:
Gas Pressure Natural Gas Propane
Minimuminletpressure 5.0in.w.c. 11.0in.w.c.
Maximuminletpressure 10.0in.w.c. 13.0in.w.c.
Manifoldpressure 3.5in.w.c. 10.0in.w.c.
c.Theapplianceanditsindividualshutovalvemustbe
disconnectedfromthegassupplypipingsystemduring
anypressuretestingofthesystemattestpressuresin
excessof1/2psig.
d. This appliance must be isolated from the gas supply
pipingsystembyclosingitsindividualmanualshuto
valve during any pressure testing of the gas supply
pipingsystemattestpressuresequaltoorlessthan
1/2psig.
WARNING! Risk of Fire or Explosion! High pressure
will damage valve. Low pressure may cause explosion.
• Verifyinletpressures.Verifyminimumpressureswhen
otherhouseholdgasappliancesareoperating.
• Install regulator upstream of valve if line pressure is
greaterthan1/2psig.
Hearth & Home Technologies • CFL-18/24/30-C, CFL-24-IPI • 526-910 Rev. X • 1/228
Figure 1.
DAMPER CLAMP
OPEN DAMPER
WARNING! Risk of Fire!
Open the chimney damper to its FULLY OPEN posi-
tion when burning this gas log set.
DO NOT burn Logs without the ue damper in the
FULL OPEN position. Failure to do so is dangerous to
your health and voids all warranties.
Note:TheCommonwealthofMassachusettsrequiresthat
thechimneyuedamper,whenusedwithgaslogs,shallbe
weldedopenorcompletelyremoved.
Figure 2. IPI Wiring Diagram-CFL-24NG-IPI and CFL-24LP-IPI
2. ELECTRICAL INSTALLATION
• Thisappliancemaybeusedwithawallswitchand/or
remotecontrol.
• Uselowresistancethermostatwireforwiringfromigni-
tionsystemtothewallswitch.
• Keepwirelengthsasshortaspossiblebyremovingany
excesswirelength.
• Lowvoltageand110VAC voltage cannot beshared
withinthesamewallbox.
BLACK
RED
BATTERY PACK
(BATTERIES REQUIRED)
WIRES
(TO BROWN)
ORANGE
GREEN
VALVE
GROUND TO
FIREPLACE
CHASSIS
WHITE
ORANGE
IGNITION MODULE 3 VAC INTERMITTENT PILOT IGNITOR
I
S
REMOTE OR
WALL SWITCH
e.Adamperstopclampwithsetscrewisprovidedtopre-
ventfullclosureofthereplacedamperblade.Attach
theclamptotheedgeofthedamperbladewithpliers
orwrenches.Ifthedamperstopsupplieddoesnott
theapplication,useapermanentmeansthatwillkeep
thedamperopentoaMINIMUMof51squareinches
(328cm2).SeeFigure1.
REMOTE
OR WALL
SWITCH
BLACK BLACK
ON/OFF
SWITCH
RED
THERMOPILE
WHITE
Figure 3. Standing Pilot Wiring Diagram
f. TestretheunitafterreferringtotheSAFETY INFOR-
MATION and LIGHTING INSTRUCTIONS  found in
Section3inthismanual,oronthelabelplateassembly
foundonthegas-burner.
g.Afterthegaslineinstallationiscomplete,allconnections
mustbetightenedandcheckedforleakswithacom-
mercially-available,non-corrosiveleakchecksolution.
Be sure to rinse o all leak check solution following
testing.RefertoSection3,OPERATING GUIDELINES
and MAINTENANCE INSTRUCTIONS.
h.Oncethegas-burneristestredandgassupplylines
arepurged,assemblethegrate(s)andlogs.Becertain
tofollowtheLogPlacementInstructionsshippedwith
theunit.RemembertokeeptheLogInstructionsalong
withthismanualforfutureuse.
9
Hearth & Home Technologies • CFL-18/24/30-C, CFL-24-IPI • 526-910 Rev. X • 1/22
4. REMOTE CONTROL
• Ifaremotecontrolisused,thereceivercannotbeplaced
undertheburner.Ifpossible,placethereceiveroutside
thecombustionchamber.
• Ifthereceivermustbeplacedinthecombustionchamber,
theprotectiveheatshieldMUSTbeused.SeeFigure4.
• Positionreceiveronleftsideofgaslogset(oppositethe
pilot). Place protective heat shield over receiver. See
Figure5.
Figure 4. Protective Heat Shield
Figure 5. Receiver Location-Left Side of Log Set
RECEIVERRECEIVER
3. AIR SHUTTER SETTINGS.
Thisappliancehasanadjustableairshutter(whichcon-
trolstheprimaryair)factorysetfortheminimumvertical
ventrun.Ifyourinstallationhasmorethantheminimum
requiredverticalventlength,adjustmentoftheairshutter
may be necessary to obtain optimal ame appearance.
This should be adjusted by a qualied installer at the
time of installation.
Air Shutter Settings
NG Propane
Burner 3/8in. FullOpen
Hearth & Home Technologies • CFL-18/24/30-C, CFL-24-IPI • 526-910 Rev. X • 1/2210
3 3 Operating Guidelines and Maintenance Instructions
Fire Risk
Be sure replace screen or glass doors are in
placewhenburningreplacelogs.Unlessother
provisionsfor combustionair areprovided,the
screenordoorsshallhaveanopeningforintro-
ductionofcombustionair.THISGASLOGSET
IS NOT DESIGNEDTO OPERATE WITHAIR
TIGHTGLASSDOORS.Adequate combustion
andcoolingairmustbeprovidedortheunitwill
notfunctionproperly.
WARNING
Fire Risk
Explosion Risk
WARNING:Toavoidpossibleinjury,reand
explosion, please read and follow these pre-
cautionsandallinstructionsonthisappliance
beforelightingthepilot.Beforelighting,smell
atoorleveland/oruseothermeans(suchas
usingacommercially-available,non-corrosive
leakchecksolutiononallpipingandconnec-
tions,usingagasdetector,etc.)tocheckforgas
leaks.NOTE:L.P.(Propane)gascanbecome
odorless and CANNOT always be detected
bysmell.
WARNING
B. Maintenance
Periodicallyremovethelogsandexaminetheburner.If
dirty,cleanwithasoftbrush.Alsoexaminetheareaaround
theburnerairshutterandthepilot.Anydirtorlintinthis
area should be removed. This will ensure long life and
trouble-freeoperation.
The appliance and venting system should be inspected
beforeinitialuseandinspectedandcleanedatleastan-
nuallybyaqualiedeldserviceperson.
A. Before Lighting Appliance
BeforelightingthisappliancedetermineifithasaStanding
Pilotor IntelliFire® ignition systembyviewingthe wiring
systemandgasvalve.Ifthisappliancehasaredorblack
ignitorbutton(seeFigure3andFigure4)thisappliance
hasaStandingPilotignitionsystem.Ifthereisnoredor
blackignitorbutton,thisappliancehasanIntelliFireignition
system.
Before operating this appliance have a qualied tech-
nician:
• Removeallshippingmaterials.
• Review proper placement of logs, rockwool, and ver-
miculite.
• Checkthewiring.
• Ensurethattherearenogasleaks.
Uponcompletingthegaslineconnection,asmallamount
ofairwillbeinthelines.Whenrstlightingthepilotlight,
itwilltakeafewminutesforthelinestopurgethemselves
of this air.  Once the purging is complete, the pilot and
burnerwill light and operate asindicated inthe instruc-
tionmanual.Subsequentlightingoftheappliancewillnot
requiresuchpurging.
WARNING
HOT SURFACES!
Glassandothersurfacesarehotduring
operationANDcooldown.
Hot glass will cause burns.
• Donottouchglassuntilitiscooled
• NEVERallowchildrentotouchglass
• Keepchildrenaway
• CAREFULLY SUPERVISE children in same room as
replace.
• Alertchildrenandadultstohazardsofhightemperatures.
High temperatures may ignite clothing or other
ammable materials.
• Keepclothing,furniture,draperiesandotherammable
materialsaway.
WARNING! Risk of Fire, Explosion or Electric Shock!
DO NOT use this appliance if any part has been under
water. Call a qualied service technician to inspect the
appliance and to replace any part of the control system
and/or gas control which has been under water.
Improper installation, adjustment, alteration, service or
maintenance can cause injury or property damage. For
assistance or additional information, consult a qualied
servicetechnician,serviceagencyoryourdealer.
11
Hearth & Home Technologies • CFL-18/24/30-C, CFL-24-IPI • 526-910 Rev. X • 1/22
Lighting Instructions (IPI)
TheIPIsystemmustbeoperatedwithtwoD-cellbatteries.
1. This appliance is equipped with an ignition
devicewhichautomaticallylightstheburner.
DO NOTtrytolighttheburnerbyhand.
2. Wait ve (5) minutes to clear out any gas.
Thensmellforgas,includingneartheoor.If
yousmellgas,STOP!Follow“B”intheSafety
Informationlocatedontheleftsideofthisla-
bel.Ifyoudonotsmellgas,gotonextstep.
3. Tolighttheburner:
 Equippedwithwallswitch:TurnON/OFFswitch
toON.
 Equippedwithremoteorwallcontrol:Press
ONorFLAMEbutton.
 Equippedwiththermostat:Settemperatureto
desiredsetting.
4. Iftheappliancedoesnotlightafterthreetries,
callyourservicetechnicianorgassupplier.
LIGHTING
INSTRUCTIONS (IPI)
TO TURN OFF
GAS TO APPLIANCE
1. Equippedwithwallswitch:TurnON/OFFswitch
toOFF.
 Equippedwithremote or wall control:Press
OFFbutton.
 Equippedwiththermostat:Settemperatureto
lowestsetting.
2. Service technician should turn o electric
powertothecontrolwhenperformingservice.
FOR YOUR SAFETY
READ BEFORE LIGHTING
WARNING: Ifyoudonotfollowtheseinstructionsexactly,areorexplosion
mayresultcausingpropertydamage,personalinjuryorlossoflife.
CAUTION:
NOT FOR USE
WITH SOLID FUEL
WARNING:
GAS
VALVE
Foradditionalinformationonoperatingyour
Hearth&HomeTechnologiesreplace,pleaserefertowww.hearthnhome.com.
A.Thisapplianceisequippedwithan
intermittentpilotignition(IPI)device
whichautomaticallylightstheburn-
er.DO NOTtrytolighttheburnerby
hand.
B. BEFORE LIGHTING,smellallaround
theapplianceareaforgas.Besureto
smellnexttotheoorbecausesome
gasisheavierthanairandwillsettle
ontheoor.
WHAT TO DO IF YOU SMELL GAS
DO NOTtrytolightanyappliance.
DO NOTtouchanyelectricswitch;do
notuseanyphoneinyourbuilding.
DO NOT CONNECT LINE VOLT-
AGE (110/120 VAC OR 220/240
VAC) TO THE CONTROL VALVE.
Improper installation, adjustment, al-
teration, service or maintenance can
causeinjuryorpropertydamage.Re-
fertotheowner’sinformationmanual
providedwiththisappliance.
This appliance needs fresh air for
safe operation and must be installed
so there are provisions for adequate
combustionandventilationair.
Hotwhileinoperation.DO NOTtouch.
Keepchildren,clothing,furniture,gaso-
lineandotherliquidshavingammable
vaporsaway.
•Immediately call your gas supplier
fromaneighborsphone.Followthe
gassuppliersinstructions.
•If you cannot reach your gas sup-
plier,calltheredepartment.
C. DO NOT use thisappliance if any
parthasbeenunderwater.Imme-
diatelycallaqualiedservicetech-
niciantoinspecttheapplianceand
to replace any part of the control
systemandanygascontrolwhich
hasbeenunderwater.
Forusewithnaturalgasandpropane.
A conversion kit, as supplied by the
manufacturer,shallbeusedtoconvert
thisappliancetothealternatefuel.
Also Certied for Installation in a
Bedroom or a Bedsitting Room.
For assistance or additional informa-
tion, consult a qualied installer, ser-
viceagencyorthegassupplier.
Final inspection by
Keepburnerandcontrolcompartment
clean. See installation and operating
instructionsaccompanyingappliance.
WARNING: This product and the
fuels used to operate this product
(liquid propane or natural gas),
andtheproductsofcombustionof
such fuels, can expose you to chemicals
includingbenzene, which isknownto the
State of California to cause cancer and
reproductiveharm. For more information
goto:www.P65Warnings.ca.gov.
Hearth & Home Technologies • CFL-18/24/30-C, CFL-24-IPI • 526-910 Rev. X • 1/2212
1. Turnoallelectricpowertotheapplianceif
serviceistobeperformed.
2. Opencontrolaccesspanel.
3. Moveswitchto“OFF”position.
4. Pushingascontrolknobslightlyandturnclock-
wise toOFF”.Donotforce.
5. Closecontrolaccesspanel.
5. Turnknobongascontrolcounterclockwise
to“PILOT”.
6. Push in control knob all the way and hold in. Im-
mediatelydepressredorblackpiezobutton.Itmay
require several depressions of the red or black
piezobuttonuntilPILOTlights.IfPILOTlightdoes
notlightafter10seconds,returntostep3.Continueto
holdthe controlknob in forabout oneminute afterthe
pilot is lit. Release knob and it will pop back out. Pilot
shouldremainlit.Ifitgoesout,repeatsteps3through6.
Ifknobdoesnotpopupwhenreleased,stopandim-
mediatelycallyourservicetechnicianorgassupplier.
 Ifthepilotwillnotstaylitafterseveraltries,turn
thegascontrolknobto“OFF”andcallyourservice
technicianorgassupplier.
7. Turngascontrolknobcounterclockwise to
“ON”.
8. TolightBurner,iptheon/oswitchtothe“ON”
position,andcloseaccessgrille.
9. Turnonallelectricpowertotheappliance.
1. Turnoallelectricpowertotheappliance.
2. Pushingascontrolknob
slightlyandturnclockwise
to“OFF”.
NOTE: Knobcannotbeturnedfrom“PILOT”to“OFF”
unlessknobispushedinslightly.Donotforce.
3. Waitve(5)minutestoclearoutanygas.
Thensmellforgas,includingneartheoor.If
yousmellgas,STOP!Follow“B”intheSafety
Informationlocatedontheleftsideofthislabel.If
youdon’tsmellgas,gotonextstep.
4. Findthepilot.Thepilotisinside
combustionchambernexttothe
mainburner.
LIGHTING
INSTRUCTIONS
TO TURN OFF
GAS TO APPLIANCE
FOR YOUR SAFETY
READ BEFORE LIGHTING
DO NOT CONNECT 110 VAC TO
THE CONTROL VALVE.
Improper installation, adjustment, al-
teration, service or maintenance can
causeinjuryorpropertydamage.Re-
fertotheowner’sinformationmanual
providedwiththisappliance.
This appliance needs fresh air for
safe operation and must be installed
so there are provisions for adequate
combustionandventilationair.
CAUTION:
Hotwhileinoperation.Donottouch.
Keepchildren,clothing,furniture,gaso-
lineandotherliquidshavingammable
vaporsaway.
NOT FOR USE
WITH SOLID FUEL
Forusewithnaturalgasandpropane.
A conversion kit, as supplied by the
manufacturer,shallbeusedtoconvert
thisappliancetothealternatefuel.
Also Certied for Installation in a
Bedroom or a Bedsitting Room.
For assistance or additional informa-
tion, consult a qualied installer, ser-
viceagencyorthegassupplier.
WARNING:
A.This appliance has a pilot which
must be lighted by hand. When
lighting the pilot, follow these in-
structionsexactly.
B. BEFORE LIGHTING, smell all
aroundtheapplianceareaforgas.
Be sure to smell next to the oor
becausesomegasisheavierthan
airandwillsettleontheoor.
WHAT TO DO IF YOU SMELL GAS
•Donottrytolightanyappliance.
• Donottouchanyelectricswitch;do
notuseanyphoneinyourbuilding.
•Immediately call your gas supplier
fromaneighbor’sphone.Followthe
gassuppliersinstructions.
•If you cannot reach your gas sup-
plier,calltheredepartment.
C.Use only your hand to push in or
turn the gas control knob. Never
usetools.Iftheknobwillnotpush
inorturnbyhand,DO NOTtryto
repair it, call a qualied service
technician. Force or attempted re-
pair may result in a re or explo-
sion.
D.Do not use this appliance if any
parthasbeenunderwater.Imme-
diatelycallaqualiedservicetech-
niciantoinspecttheapplianceand
to replace any part of the control
systemandanygascontrolwhich
hasbeenunderwater.
Foradditionalinformationonoperatingyour
Hearth&HomeTechnologiesreplace,pleaserefertowww.replaces.com.
WARNING: If you do not follow these instructions
exactly,areorexplosionmayresultcausingproperty
damage,personalinjuryorlossoflife.
Final inspection by
Figure 8. Standing Pilot Lighting Instructions
Lighting Instructions (Standing Pilot)
WARNING: This product and the
fuels used to operate this product
(liquid propane or natural gas),
andtheproductsofcombustionof
such fuels, can expose you to chemicals
includingbenzene, which isknownto the
State of California to cause cancer and
reproductiveharm. For more information
goto:www.P65Warnings.ca.gov.
Keepburnerandcontrolcompartment
clean. See installation and operating
instructionsaccompanyingappliance.
13
Hearth & Home Technologies • CFL-18/24/30-C, CFL-24-IPI • 526-910 Rev. X • 1/22
A. Standing Pilot Ignition System
4 4 Troubleshooting
Withproperinstallation,operation,andmaintenanceyourgasappliancewillprovideyearsoftrouble-freeservice.Ifyoudo
experienceaproblem,thistroubleshootingguidewillassistaqualiedservicetechnicianinthediagnosisofaproblemand
thecorrectiveactiontobetaken.Thistroubleshootingguidecanonlybeusedbyaqualiedservicetechnician.Contact
yourdealertoarrangeaservicecallbyaqualiedservicetechnician.
Symptom Possible Causes Corrective Action
1.Afterrepeatedtriggering
oftheredorblackpiezo
ignitorbutton,thespark
ignitorwillnotlightthe
pilot.
A.Nogasorlowgaspressure. Checktheremoteshut-ovalvesfromtheappliance.Usually,there
isavalvenearthegasmain.Therecanbemorethanonevalve
betweentheapplianceandthemain.
B.Nopropaneintank. Checkthepropanetank.Youmaybeoutoffuel.
C.Ignitor. Checkthesparkattheelectrodeandpilot.Ifnosparkandelectrode
wireisproperlyconnected,replacetheignitor.Verifythatthereisno
shortinelectrodewire.
D.Pilotormisalignedelectrode
(sparkatelectrode).
Usingmatch,lightthepilot.Ifthepilotlights,turnothepilotand
triggerthepiezoignitorbuttonagain.Ifthepilotlights,animproper
gas/airmixturecausedthebadlightingandalongerpurgeperiodis
recommended.Ifthepilotwillnotlight,ensurethegapattheelec-
trodeandpilotisone-eighthin.tohaveastrongspark.Ifthegapis
OK,replacethepilot.
2.Thepilotwillnotstaylit
aftercarefullyfollowing
thelightinginstructions.
A.Thermocouple. Checkthatthepilotameimpingesonthethermocouple.Adjustthe
pilotforproperameimpingement.
Ensurethatthethermocoupleconnectionatthegasvalveisfully
insertedandtight(handtightenplus1/4turn).
Verifypropervoltageoutputfromthethermocoupletothevalve.
Placeonemillivoltmeterleadwireonthethermocouplecopperlead.
Placethesecondleadwireonthesolderbuttononthebackofthe
valve(bluewire).Startthepilotandholdthevalveknobin.The
millivoltreadingshouldread8-16millivolts.Ifmillivoltreadingis
lessthan8millivolts,replacethermocouple.
B.Impropergasinletpressure. Naturalgasshouldbe5-10in.w.c.Propaneshouldbe11-13in.
w.c.Verifypressurewithmanometer.
C.Valve. Ifthethermocoupleisproducing8-16millivolts,replacecontrolvalve.
3.Thepilotisburning,
thereisnoburner
ame,thevalveknobis
intheONposition,and
theON/OFFswitchisin
theONposition.
A.On/oswitchorwires. ChecktheON/OFFswitchandwiresforproperconnections.Place
thejumperwiresacrosstheterminalsattheswitch.Iftheburner
comeson,replacetheswitch.IftheswitchisOK,placethejumper
wiresacrosstheswitchwiresatthegasvalve.Iftheburnercomes
on,thewiresarefaultyorconnectionsarebad.
B.Thermopilemaynotbegen-
eratingsucientmillivoltage.
Checkthatthepilotameimpingesthermopileproperly.
Besurethewireconnectionsfromthethermopileatthegasvalve
terminalsaretightandthatthethermopileisfullyinsertedintothe
pilotbracket.
Checkthethermopilewithamillivoltmeter.Takethereadingat
TH-TP&TPterminalsofthegasvalve.Themetershouldread350
millivoltsminimum,whileholdingthevalveknobdepressedinthe
pilotposition,withthepilotlit,andtheON/OFFswitchintheOFF
position.Replacethethermopileifthereadingisbelowthespecied
minimum.
WiththepilotintheONposition,disconnectthethermopileleads
fromthevalve.Takeareadingatthethermopileleads.Theread-
ingshouldbe350millivoltsminimum.Replacethethermopileifthe
readingisbelowtheminimum.
Hearth & Home Technologies • CFL-18/24/30-C, CFL-24-IPI • 526-910 Rev. X • 1/2214
Troubleshooting (continued)
Symptom Possible Cause Corrective Action
3.(Continued) c.Valve. TurnthevalveknobtotheONposition.Placethe
ON/OFFswitchintheONposition.Checkthemillivolt
meterathethermopileterminals.Themillivoltmeter
shouldreadgreaterthan125mV.Ifthereadingisac-
ceptable,andiftheburnerdoesnotcomeon,replace
thegasvalve.
d.Pluggedburnerorice. Checktheburneroriceforstoppage.Removestop-
page.
e.Wallswitchorwires. FollowthecorrectiveactioninSymptomandPossible
Cause1.aabove.Checktheswitchandwiring.
4.Frequentpilotoutage
problem.
a.Pilotamemaybetoohighortoolow,orblow-
ingout(highpressure),causingpilotsafetyto
dropout.
Cleanthermocoupleandadjustthepilotamefor
properameimpingement.Followlightinginstructions
carefully.
5.Thepilotandmain
burnerextinguish
whileinoperation.
a.Nopropaneintank. Checkthepropanetank.Rellthefueltank.
b.Impropergasinletpressure. Verifywithmanometer.NGshouldread5-14in.w.c.
Propaneshouldread10-14in.w.c.
c.Innerventpipeleakingexhaustgasesbackinto
thesystem.
Checkventingsystemfordamage.Replace/repair
improperlyassembledpipesections.
d.Glassinstalledimproperly. Checktoensureglassisinstalledproperly.Replace
glasspanelassembly.
e.Thermopileorthermocouple. Replacepilotifnecessary.
f.Improperventcapinstallation. Checkforproperinstallationandfreedomfromdebris
orblockage.
15
Hearth & Home Technologies • CFL-18/24/30-C, CFL-24-IPI • 526-910 Rev. X • 1/22
B. IntelliFire® Ignition System
Symptom Possible Cause Corrective Action
1.Pilotwon’tlight.
Theignitor/module
makesnoise,butno
spark.
a.Incorrectwiring. Verify“S”wire(white)forsensorand“I”wire(orange)forignitor
areconnectedtocorrectterminalsonmoduleandpilotassembly.
b.Looseconnectionsorelectrical
shortsinthewiring.
Verifynolooseconnectionsorelectricalshortsinwiringfrom
moduletopilotassembly.Verifyconnectionsunderneathpilotas-
semblyaretight;alsoverifyconnectionsarenotgroundingoutto
metalchassis,pilotburner,pilotenclosure,meshscreenifpresent,
oranyothermetalobject.
c.Ignitorgapistoolarge. Verifygapofignitertorightsideofpilothood.Thegapshouldbe
approximately.17in.or1/8in.(3mm).
d.Module. TurnON/OFFrockerswitchorwallswitchtoOFFposition.Remove
ignitorwire“I”frommodule.Placeagroundedwireabout3/16in.(5
mm)awayfrom“I”terminalonmodule.PlaceON/OFFrockerswitch
orwallswitchinONposition.Ifthereisnosparkat“I”terminal
modulemustbereplaced.Ifthereisasparkat“I”terminal,module
isne.Inspectpilotassemblyforshortedsparkerwireorcracked
insulatoraroundelectrode.Replacepilotifnecessary.
2.Pilotwon’tlight,
there is no noise or
spark.
a.Nopower. Checkbatteries.
b.Ashortedorlooseconnectionin
wiringcongurationorwiringhar-
ness.
Removeandreinstallthewiringharnessthatplugsintomodule.
Verifythereisatightt.Verifypilotassemblywiringtomodule.Re-
moveandverifycontinuityofeachwireinwiringharness.Replace
anydamagedcomponents.
c.Improperwallswitchwiring. Checkwiringconnections.
d.Modulenotgrounded. Verifyblackgroundwirefrommodulewireharnessisgroundedto
metalchassisofappliance.
e.Module. TurnON/OFFrockerswitchorwallswitchtoOFFposition.Re-
moveignitorwire“I”frommodule.PlaceON/OFFrockerswitch
orwallswitchinONposition.Ifthereisnosparkat“I”terminal
modulemustbereplaced.Ifthereisasparkat“I”terminal,module
isne.Inspectpilotassemblyforshortedsparkerwireorcracked
insulatoraroundelectrode.
3.Pilotsparks,but
Pilotwillnotlight.
a.Gassupply. Verifythatincominggaslineballvalveis“open”.Verifythatinlet
pressurereadingiswithinacceptablelimits,inletpressuremust
notexceed14in.W.C.
b.Ignitorgapisincorrect. Verifythatsparkgapfromignitortopilothoodis.17in.or1/8in(3mm).
c.Moduleisnotgrounded. Verifymoduleissecurelygroundedtometalchassisofappliance.
d.Modulevoltageoutput/Valve/Pilot
solenoidohmsreadings.
Verifybatteryvoltageisatleast2.7volts.Replacebatteriesifvolt-
ageisbelow2.7.
Hearth & Home Technologies • CFL-18/24/30-C, CFL-24-IPI • 526-910 Rev. X • 1/2216
IntelliFire Ignition System - (continued)
Symptom Possible Cause Corrective Action
4.Pilotlightsbutcontin-
uestospark,andmain
burnerwillnotignite.
(Ifthepilotcontinues
tosparkafterthe
pilotamehasbeenlit,
amerecticationhas
notoccurred.)
a.Ashortedorlooseconnectioniname
sensingrod.
Verifyallconnectionstowiringdiagraminmanual.Verify
connectionsunderneathpilotassemblyaretight.Verify
connectionsarenotgroundingouttometalchassis,pilot
burner,pilotenclosureorscreenifpresent,oranyother
metalobject.
b.Pooramerecticationorcontaminated
amesensingrod.
Withxedglassassemblyinplace,verifythatameisen-
gulngamesensingrodonleftsideofpilothood.Flame
sensingrod shouldglowshortlyafterignition.Verifycor-
rectpilotoriceisinstalledandgasinletissettopressure
specications.Polishamesensingrodwithnesteelwool
toremoveanycontaminantsthatmayhaveaccumulated
onamesensingrod.
c.Moduleisnotgrounded. Verifymoduleissecurelygroundedtometalchassisof
appliance.Verifythatwireharnessisrmlyconnectedto
themodule.
d.Damagedpilotassemblyorcontami-
natedamesensingrod.
Verifythatceramicinsulatoraroundtheamesensingrod
isnotcracked,damaged,orloose.Verifyconnectionfrom
amesensingrodtowhitesensorwire.Polishamesens-
ingrodwithnesteelwooltoremoveanycontaminants
thatmayhaveaccumulatedonamesensingrod.Verify
continuitywithamultimeterwithohmssetatlowestrange.
Replacepilotifanydamageisdetected.
e.Module. TurnON/OFFrockerswitchorwallswitchtoOFFposition.
Removeignitorwire“I”frommodule.PlaceON/OFFrocker
switchorwallswitchinONposition.Ifthereisnosparkat
“I”terminalmodulemustbereplaced.Ifthereisasparkat
“I”terminal,moduleisne.
17
Hearth & Home Technologies • CFL-18/24/30-C, CFL-24-IPI • 526-910 Rev. X • 1/22
5 5 Reference Materials
Service Parts
IMPORTANT: THIS IS DATED INFORMATION. Parts must be ordered from a dealer or
distributor. Hearth and Home Technologies does not sell directly to consumers. Provide
model number and serial number when requesting service parts from your dealer or distributor.
Stocked
at Depot
ITEM DESCRIPTION COMMENTS PART NUMBER
Log Assembly LOGS-CFL18
1 Log 1
Pre 5/15/16, Must
order complete
assembly
SRV481-766
2 Log 2
3 Log 3 SRV481-755
4 Log 4
5 Log 5 SRV481-701
6Log 6 SRV481-705
7 Log 7 SRV446-702
8Log 8 SRV481-703
9 Log 9 SRV402-701
10 Log 10 SRV446-706
11 Burner Assembly 526-010A Y
12 Flexible Gas Connector 477-301A Y
13 Grate Assembly SRV526-360
14 Valve NG 418-500 Y
Valve LP 418-501 Y
15 ON/O Switch 060-521A Y
16 Flex Ball Valve Assembly SRV302-320 Y
17 Pilot Assembly NG 2103-010 Y
Pilot Assembly LP 2103-011 Y
Additional service parts on following page 8/21
Log Set Assembly
5
2
4
9
8
6
1
3
10
7
Campre 18” Gas Log Set
CFL-18NG-C, CFL-18LP-C
Beginning Manufacturing Date: Nov 2007
Ending Manufacturing Date: Active
11
12
13
14
15 16
17
A. Service Parts
Hearth & Home Technologies • CFL-18/24/30-C, CFL-24-IPI • 526-910 Rev. X • 1/2218
Service Parts
Beginning Manufacturing Date: Nov 2007
Ending Manufacturing Date: Active
CFL-24NG-C, CFL-24LP-C
IMPORTANT: THIS IS DATED INFORMATION. Parts must be ordered from a dealer or
distributor. Hearth and Home Technologies does not sell directly to consumers. Provide
model number and serial number when requesting service parts from your dealer or distributor.
Stocked
at Depot
ITEM DESCRIPTION COMMENTS PART NUMBER
Log Assembly LOGS-CFL24
1 Log 1
Pre 5/15/16, Must
order complete
assembly
SRV481-766
2 Log 2
3 Log 3 SRV481-755
4 Log 4
5 Log 5 SRV526-701
6Log 6 SRV481-705
7 Log 7 SRV446-702
8Log 8 SRV481-703
9 Log 9 SRV402-701
10 Log 10 SRV446-706
11 Burner Assembly 526-010A Y
12 Flexible Gas Connector 477-301A Y
13 Grate Assembly SRV526-360
14 Valve NG 418-500 Y
Valve LP 418-501 Y
15 ON/O Switch 060-521A Y
16 Flex Ball Valve Assembly SRV302-320 Y
17 Pilot Assembly NG 2103-010 Y
Pilot Assembly LP 2103-011 Y
Additional service parts on following page 8/21
11
12
13
14
15 16
17
5
10
6
1
34
2
7
9
8
Log Set Assembly
19
Hearth & Home Technologies • CFL-18/24/30-C, CFL-24-IPI • 526-910 Rev. X • 1/22
Service Parts CFL-24NG-IPI, CFL-24LP-IPI
Beginning Manufacturing Date: Aug 2009
Ending Manufacturing Date: Active
IMPORTANT: THIS IS DATED INFORMATION. Parts must be ordered from a dealer or
distributor. Hearth and Home Technologies does not sell directly to consumers. Provide
model number and serial number when requesting service parts from your dealer or distributor.
Stocked
at Depot
ITEM DESCRIPTION COMMENTS PART NUMBER
Log Assembly LOGS-CFL24
1 Log 1
Pre 5/15/16, Must
order complete
assembly
SRV481-766
2 Log 2
3 Log 3 SRV481-755
4 Log 4
5 Log 5 SRV526-701
6Log 6 SRV481-705
7 Log 7 SRV446-702
8Log 8 SRV481-703
9 Log 9 SRV402-701
10 Log 10 SRV446-706
11 Burner Assembly 526-010A Y
12 Flexible Gas Connector 477-301A Y
13 Grate Assembly SRV526-360
14 Valve NG SRV593-500 Y
Valve LP SRV593-501 Y
15 Control Module SRV593-595 Y
16 ON/O Switch 060-521A Y
17 Flex Ball Valve Assembly SRV302-320 Y
18 Pilot Assembly NG SRV2090-012 Y
Pilot Assembly LP 2090-013 Y
Additional service parts on following page 8/21
11
12
13
14
16 17
18
15
5
10
6
1
34
2
7
9
8
Log Set Assembly
Hearth & Home Technologies • CFL-18/24/30-C, CFL-24-IPI • 526-910 Rev. X • 1/2220
Service Parts
Beginning Manufacturing Date: Nov 2007
Ending Manufacturing Date: Active
CFL-30NG-C, CFL-30LP-C
IMPORTANT: THIS IS DATED INFORMATION. Parts must be ordered from a dealer or
distributor. Hearth and Home Technologies does not sell directly to consumers. Provide
model number and serial number when requesting service parts from your dealer or distributor.
Stocked
at Depot
ITEM DESCRIPTION COMMENTS PART NUMBER
Log Assembly LOGS-CFL30
1 Log 1
Pre 5/15/16, Must
order complete
assembly
SRV526-766
2 Log 2
3 Log 3 SRV526-755
4 Log 4
5 Log 5 SRV526-701
6Log 6 SRV481-705
7 Log 7 SRV446-702
8Log 8 SRV481-704
9 Log 9 SRV446-705
10 Log 10 SRV446-706
11 Log 11 SRV530-703
12 Burner Assembly 526-010A Y
13 Flexible Gas Connector 477-301A Y
14 Grate Assembly SRV526-360
15 Valve NG 418-500 Y
Valve LP 418-501 Y
16 ON/O Switch 060-521A Y
17 Flex Ball Valve Assembly SRV302-320 Y
18 Pilot Assembly NG 2103-010 Y
Pilot Assembly LP 2103-011 Y
Additonal service parts on following page 8/21
18
12
13
14
15
16 17
10 89
5
11
7
1
3
2
4
6
Log Set Assembly
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24

Heat & Glo Campfire User manual

Category
Fireplaces
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI