Pakedge SX-8P User manual

Type
User manual
SX-8P
Enterprise-AV, Smart Managed Switches
User Guide
2
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions:
1. This device may not cause harmful interference.
2. This device must accept any interference received, including interference that may cause
undesired operation.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that interference will not occur
in a particular installation. If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the user is encouraged to try
to correct the interference by one of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver
is connected.
Consult the dealer or an experienced radio/TV technician for help.
WARNING: Any changes or modifications not expressly approved by the party responsible for
compliance could void the user's authority to operate this equipment.
WARNING: TO PREVENT FIRE OR SHOCK HAZARD, DO NOT EXPOSE THIS PRODUCT TO RAIN OR
MOISTURE. THE UNIT MUST NOT BE EXPOSED TO DRIPPING OR SPLASHING WATER. CAUTION: DO
NOT OPEN THE UNIT. DO NO PERFORM ANY SERVICING OTHER THAN THAT CONTAINED IN THE
INSTALLATION AND TROUBLESHOOTING INSTRUCTIONS. REFER ALL SERVICING TO QUALIFIED SERVICE
PERSONNEL. CAUTION: THIS DEVICE MUST BE INSTALLED AND USED IN STRICT ACCORDANCE WITH
THE MANUFACTURERS INSTRUCTIONS AS DESCRIBED IN THE USER DOCUMENTATION THAT COMES
WITH THE PRODUCT. CHANGES OR MODIFICATIONS NOT EXPRESSLY APPROVED BY THE PARTY
RESPONSIBLE FOR COMPLIANCE COULD VOID THE USERS AUTHORITY TO OPERATE THE EQUIPMENT.
WARNING: POSTPONE INSTALLATION UNTIL THERE IS NO RISK OF THUNDERSTORM OR LIGHTNING
ACTIVITY IN THE AREA.
Safety Guidelines
Observe the following safety guideline to ensure your own personal safety and to help protect your
system from potential damage.
Basic Requirements
1. Keep the device strictly dry while storing, shipping and using;
2. Keep the device from fierce collision;
3. Follow the instructions provided in this manual to install the device;
4. Please contact the specified maintenance staff rather than remove the device on your own if any
fault happens.
Environmental Requirements
1. Temperature- Install the switch in a dry area, with ambient temperature between 0 and 40°C (32
and 104°F). Keep the switch away from heat sources such as direct sunlight, warm air exhausts,
hot-air vents, and heaters;
3
2. Operating humidity -The installation location should have a maximum relative humidity of
90%, non-condensing;
3. Ventilation-Do not restrict airflow by covering or obstructing air inlets on the sides of the switch. Keep
it at least10cm free on all sides for cooling. Be sure there is adequate airflow in the room or wiring
closet where the switch is installed;
4. Operating conditionsKeep the switch away from nearest source of electromagnetic noise,
such as photo copy machines, microwaves, cellphones, etc.
Use Notes
1. Use the provided accessories, such as the cable, mounting kit, etc.;
2. Ensure the basic supply voltage standard must be met;
3. Keep the power plug clean and dry in case of electric shock or other dangers;
4. Keep your hands dry while plugging cables;
5. Shutdown the device and power it off before plugging cables;
6. Disconnect the power supply and pull out all cables, such as the power cord, fiber, Ethernet cable,
etc. in lightening days;
7. Disconnect the power supply and pull out the plug if the device is out of use for a longtime;
8. Keep the device far from water or other liquids;
9. Contact the specified maintenance staff if any problem occurs;
10. Do not tread on, drag or excessively bend its cable;
11. Do not use worn cables;
12. Do not look the fiber interface in your eyes in case of eye damage;
14. Prevent some matters, such as metals, from entering the device through the ventilation hole;
15. Do not scrape or fray the device’s housing shell in case of abnormal operation or human body
allergic;
16. Keep the device out of children’s reaches.
Cleaning Notes
1. Shut down the device and pull out all cables before cleaning it;
2. Use soft cloth to clean the device’s housing shell.
Environmental Protection
1. Throw the discarded device or batteries into the specified recycling places;
2. Observe local relevant packages, wasted batteries and discarded device processing acts and
support recycling action.
4
CONTENTS
Introduction .............................................................................................................................................. 5
Customer service and technical support .................................................................................................. 5
Accessing the Switch ................................................................................................................................. 8
Dashboard ................................................................................................................................................. 9
System ....................................................................................................................................................... 9
Basic Settings .......................................................................................................................................... 10
Ports ........................................................................................................................................................ 16
Port Settings ............................................................................................................................................ 16
PoE .......................................................................................................................................................... 24
MAC Control ............................................................................................................................................ 26
VLANs ...................................................................................................................................................... 27
Voice VLAN .............................................................................................................................................. 33
Traffic menu ............................................................................................................................................ 35
QoS .......................................................................................................................................................... 36
STP ........................................................................................................................................................... 41
IGMP ....................................................................................................................................................... 45
Maintenance ........................................................................................................................................... 49
SNMP ....................................................................................................................................................... 50
LLDP ......................................................................................................................................................... 51
Syslog ...................................................................................................................................................... 53
Network Diagnostics ............................................................................................................................... 54
Appendix A Technical Support ............................................................................................................. 56
Appendix B Specifications .................................................................................................................... 57
Appendix C Limited Warranty .............................................................................................................. 59
5
INTRODUCTION
The SX Series 8-port Smart Gigabit Switches provide 8 10/100/1000 Mbps auto-sensing RJ45 ports, 1
1000 Mbps Dedicated fiber port, and one Console port. They support IEEE 802.3af-compliant PDs
(15.4W) as well as IEEE802.3at-compliant PDs (30W). In addition, they support VLANs, QoS, IGMP
snooping, S T P, R S T P, port mirroring, link aggregation and many other features. Aiming at solving the
safety problems in LAN, it provides user management classification, management VLAN, ARP attack
defense, worm attack defense, DoS attack defense, MAC attack defense, MAC filter and other safety
settings through visual WEB interface operations. With high performance and low cost, they are ideal for
residential and enterprise AV networks.
CUSTOMER SERVICE AND TECHNICAL SUPPORT
Pakedge Device & Software, Inc. is committed to providing you with exceptional support on all of our
products. If you wish to speak with one of our representatives, you may contact us at:
Customer Service
Email: customerservice@pakedge.com
Phone: 650.385.8701
Technical Support
Email: support@pakedge.com
Phone: 650.385.8703
Website: www.pakedge.com
Visit our website for up-to-date support information.
Please be prepared to provide your product's model and serial number when contacting Pakedge
Support. Your model and serial numbers are printed on a label located on the electronic housing.
Pakedge Device & Software, Inc.
3847 Breakwater Avenue
Hayward, CA 94545
USA
Installing
For installation procedures, please refer to the Quick Start Guide that came with the SX switch. You can
also visit the dealer portal on our website for all the current manuals and Quick Start Guides.
Note: If you install the switch in a closed or multi-unit rack assembly, the operating ambient
temperature of the rack environment may be greater than the room temperature. Make sure you install
the equipment somewhere within the recommended temperature range.
For free-standing installation, make sure that the switch has at least 1.5 in. (3.75cm) of clearance on
each side to allow for adequate air flow and cooling.
6
GETTING TO KNOW YOUR PRODUCT
Package contents:
SX Series switch
Power cord
Quick Start Guide
Console cable
Mounting Kit (2 side brackets, 1 face bracket, screws)
The front panel of the SX switches has several blue LEDs. See Table1 below for more information.
Table 1: Front panel LED explanation from left to right.
LED Status Operation
SFP
Blue Port is online (link established)
Flashing Blue Activity
Off No device connected
Ports 1-8 PoE
Blue PoE in use
Flashing Blue PoE error
Off No PoE in use
Ports 1-8 LINK/
ACT
Blue Port is online (link established)
Flashing Blue Activity
Off No device connected
PWR Blue The switch is powered on
Off The switch is turned off
SYS Blue The switch has booted
Flashing Blue The switch is booting
7
The rear panel of the SX Series switches provides all inputs for a clean installation. See Table 2 below for
more information.
Table 2: Rear panel port connection explanation from left to right.
Input Description
Power Power adapter input
Ports 1-8 RJ45 PoE/PoE+ ports
SFP Port 1G SFP port
CONSOLE RJ45 console port
RESET Reset button. Press and hold for 10
seconds to factory reset the switch
Reset Button
To restore factory defaults, press and hold the button for more than 10 seconds when the switch
functions correctly. When pressing it for a while, SYS LED will be off and POWER LED is solid. The device
will restart and all LEDs will be on. When there booting finished, SYS LED will be blinking, indicating
restoring to default factory settings.
Note------------------------------------------------------------------------------------------------------------------------------
1. Please keep the switch in a dry and well-ventilated environment.
2. Keep the work bench stable and well-earthed.
3. Do not restrict airflow covering or obstructing air in lets of the switch. Keep more than 10 centimeters
free on all sides for cooling. Be sure there is adequate air flow in the room or wiring closet where the
switch is installed.
4. Don’t put heavy articles on the Switch.
5. Make sure there is more than 1.5 centimeters vertical distance free between devices that stack each
other.
------------------------------------------------------------------------------------------------------------------------------------------
Connecting SFP fiber port
The small form-factor pluggable (SFP) module is a compact, hot-pluggable transceiver used for optical
signal transmission. The module bay is a standalone port, making it the “9thport on the switch. The SFP
module accommodates a standard 1G SFP module with an LC co nnec to r.
8
ACCESSING THE SWITCH
To access the switchs GUI, follow the steps below:
1. If your network currently uses an IP scheme of 192.168.1.X, skip to step 4, otherwise continue to
step 2.
2. Plug an Ethernet cable from the switch to your PC.
3. Set your computer to a static IP of 192.168.1.10. The following image is an example of this.
4. Open any Internet browser and go to the address http://192.168.1.205. Note: For best results
we recommend using Mozilla Firefox as your web browser. If you are using Internet Explorer,
please use version 9 or newer.
5. Enter the default username pakedge and password pakedges. Click Login.
Important: It is recommended that you change this default password.
9
DASHBOARD
The dashboard provides frequently used quick links to help with more efficient setup.
SYSTEM
The System section contains the three sub sections System Settings, Security and Time Range
Management, each of will be covered next.
10
BASIC SETTINGS
The System Settings page’s Basic Settings page will display the System Description, firmware version,
serial number, and system up time.
Below the system up time, you will also see the settings to use when consoling into the switch.
Further down the basic settings page you will find additional settings.
The Name field indicates the hostname of the switch. The Management VLAN indicates the VLAN on
which the management GUI of the switch will reside on. The MAC Age field indicates how long a mac
address that was dynamically learned will be kept in the forwarding table of the switch. The Login
Timeout(min) field is the setting for the number of idle minutes before a user is automatically logged
out of the web page.
The DHCP field can be set to Enable to allow the switch to obtain its IP address automatically via DHCP.
By default, the DHCP field is set to Disable to allow the switch to use a static IP. To change the IP address
11
of the switch, enter a new IP address into the IP address field. You may also change the Subnet Mask
and Gateway of the switch.
Click Apply to finalize any setting changes you make on this page.
The System Time page will display the current time. Use the Time Zone drop down menu to set the time
zone. Enable Daylight Saving Time to have the switch automatically adjust the time when Daylight
Savings occurs, and set the dates and times it will take effect. Select Server Configuration to specify an
SNTP server for the switch to use to synchronize its time. You may enter the SNTP server IP address in
the Preferred SNTP Server field. Enter the public SNTP server IP or domain name into the Server Port
field.
Use the Set Time & Date Manually field to manually input the system time. Click Apply to finalize your
settings on this page.
12
The User Management page allows you to adjust settings to the user accounts that manage the switch.
To change the password to the switch, enter the Current Password and then enter the New Password.
You will need to Re-enter the new password.
You can create a new user by selecting New under Multi-user Management Configuration. Enter the
new Username. Enter a password in the New Password field. You will need to re-enter the password to
confirm. The Privileges field allows you to set a privilege level for the new user. Normal privilege will
allow a user to log into the switch in read only mode. A Privileged user can make changes to the switch.
Click Apply (at the bottom of the screen) to finalize the settings.
13
The System Reboot page allows you to reboot the switch. Click Reboot System to perform a reboot.
Security
Protected Port page
This setting allows the user to prevent the selected ports from communication with each other.
Protected ports are allowed to communicate only with unprotected ports. No traffic will be allowed to
pass between any two ports both set to “Protected”. To protect a port, click it to select it, then select
Protected from the Protected Port State drop-down menu.
14
DoS page
A Denial of Service (DoS) attack is an attempt to make a device unavailable to its users. DoS attacks
saturate the device with external communication requests, so that it cannot respond to legitimate
traffic. These attacks usually lead to a device CPU overload.
The DoS protection feature is a set of predefined rules that protect the network from malicious attacks.
The Property section allows activation of the security settings.
POD: Avoids ping of death attack.
Land: Drops the packets if the source IP address is equal to the destination IP address.
UDP Blat: Drops the packets if the UDP source port equals to the UDP destination port.
TCP Blat: Drops the packages if the TCP source port is equal to the TCP destination port.
DMAC = SMAC: Drops the packets if the destination MAC address is equal to the source MAC address.
Null Scan Attack: Drops the packets with NULL scan.
X-Mas Scan Attack: Drops the packets if the sequence number is zero, and the FIN, URG and PSH bits
are set.
TCP SYN-FIN Attack: Drops the packets with SYN and FIN bits set.
15
TCP SYN-RST Attack: Drops the packets with SYN and RST bits set.
ICMP Fragment: Drops the fragmented ICMP packets.
TCP- SYN: Drops SYN packets with sport less than 1024.
TCP Fragment: Drops the TCP fragment packets with offset equals to one.
Ping Max Size: Specify the maximum size of the ICMPv4/ICMPv6 ping packets. The valid range is from 0
to 65535 bytes, and the default value is 512 bytes.
TCP Min Hdr Size: Checks the minimum TCP header and drops the TCP packets with the header smaller
than the minimum size. The length range is from 0 to 31 bytes, and default length is 20 bytes.
IPv6 Min Fragment: Checks the minimum size of IPv6 fragments, and drops the packets smaller than the
minimum size. The valid range is from 0 to 65535 bytes, and default value is 1240 bytes.
Smurf Attack: Avoids smurf attack. The length range of the netmask is from 0 to 32 bytes, and default
length is 0 bytes.
To apply the settings:
1. Click the Port Setting tab.
2. Click the ports to apply your DoS settings to, then click Apply.
16
PORTS
The Ports section contains three subsections. Each will be covered next.
PORT SETTINGS
Common Configuration page
The Common Configuration page will allow you to change a port state or port speed. You can simply click
on a port to select it (you can also select multiple ports) and then change the port State or Set Rate
down below. Click Apply to finalize your settings.
17
Port Statistics page
The port statistics page allows you to see statistics per port. Select a port from the drop down menu
towards the top and you will see statistics such as received and sent bytes and even if there are errors
on the port. Click Refresh to manually update the information on the page. Click Clear All to clear the
statistics on all ports. Click Clear to only clear the statistics of the selected port.
Flow Control
The Flow Control page allows you to enable or disable flow control per port. With flow control enabled
on both the switch and its link partner, the switch, when encountering congestion, will send flow control
frames to notify the link partner of such; upon receiving such frames, the link partner will temporarily
stop sending packets to the switch, thus avoiding packets drop and ensuring a reliable network.
Meanwhile, if a certain port receives a Pause frame, it will also stop sending packets out. By default, the
18
flow control feature is disabled. To change the state of flow control, select the ports you want to change
and then change the State down below. Click Apply to finalize the settings.
19
Broadcast Storm
The Broadcast storm page allows you to limit the amount of broadcast, multicast, or unicast data that is
allowed to pass incoming per port.
The Storm Control Global Setup allows you to modify how incoming traffic is calculated for storm
control.
Storm Control Mode: Select the unit of storm control.
Packet / Sec: storm control rate calculated by packet
Kbits / Sec: storm control rate calculated by kilobit
Storm Control IFG: Calculates traffic with or w/o preamble (8 bytes) & Inter-Frame Gap (12 bytes)
taken into account.
Exclude: exclude the preamble & IFG (20 bytes) when counting ingress storm control rate.
Include: include preamble & IFG (20 bytes) when counting ingress storm control rate.
The Port section allows you to configure individual ports with the desired storm control values.
[Port]: Select the ports to configure.
State: Select the state of setting.
Enable: Enable the storm control function.
Broadcast
State: Enable or Disable the storm control function of Broadcast packet.
20
Rate: Value of storm control rate, Unit: pps (packet per-second, range 1 - 262143) or
Kbps (Kbits per-second, range16 - 1000000) depends on global mode setting.
Unknown Multicast
State: Enable or Disable the storm control function of Unknown multicast packet.
Rate: Value of storm control rate, Unit: pps (packet per-second, range 1 - 262143) or
Kbps (Kbits per-second, range16 - 1000000) depends on global mode setting.
Unknown Unicast
State: Enable or Disable the storm control function of Unknown unicast packet.
Rate: Value of storm control rate, Unit: pps (packet per-second, range 1 - 262143) or
Kbps (Kbits per-second, range16 - 1000000) depends on global mode setting.
Action: Select the state of setting:
Drop: Packets exceed storm control rate will be dropped.
Shutdown: Port will be shut down when packets exceed storm control rate.
Link Aggregation page
Link aggregation groups multiple Ethernet ports together in parallel to act as a single logical link.
Aggregation-enabled devices treat all physical links (ports) in an aggregation group entirely as a single
logical link (port). Member ports in an aggregation group share egress/ingress traffic load, delivering a
bandwidth that is multiple of a single physical link. Link aggregation provides redundancy in case one of
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61

Pakedge SX-8P User manual