H3C WX3508H Installation guide

Type
Installation guide

This manual is also suitable for

H3C WX3500H Series Access Controllers
Installation Guide
New H3C Technologies Co., Ltd.
http://www.h3c.com.hk
Document version: 6W103-20170519
Copyright © 2015-2017, New H3C Technologies Co., Ltd. and its licensors
All rights reserved
No part of this manual may be reproduced or transmitted in any form or by any means without prior written
consent of New H3C Technologies Co., Ltd.
Trademarks
H3C, , H3CS, H3CIE, H3CNE, Aolynk, , H
3
Care, , IRF, NetPilot, Netflow, SecEngine,
SecPath, SecCenter, SecBlade, Comware, ITCMM and HUASAN are trademarks of New H3C Technologies
Co., Ltd.
All other trademarks that may be mentioned in this manual are the property of their respective owners
Notice
The information in this document is subject to change without notice. Every effort has been made in the
preparation of this document to ensure accuracy of the contents, but all statements, information, and
recommendations in this document do not constitute the warranty of any kind, express or implied.
Environmental protection
This product has been designed to comply with the environmental protection requirements. The storage, use,
and disposal of this product must meet the applicable national laws and regulations.
Preface
This installation guide describes the procedures for installing, accessing, troubleshooting, and
maintaining the WX3500H access controllers.
This preface includes the following topics about the documentation:
Audience.
Conventions
Obtaining documentation
Technical support
Documentation feedback
Audience
This documentation is intended for:
Network planners.
Field technical support and servicing engineers.
Network administrators working with the WX3500H access controllers.
Conventions
The following information describes the conventions used in the documentation.
Command conventions
Convention Description
Boldface Bold
text represents commands and keywords that you enter literally as shown.
Italic
Italic text represents arguments that you replace with actual values.
[ ] Square brackets enclose syntax choices (keywords or arguments) that are optional.
{ x | y | ... }
Braces enclose a set of required syntax choices separated by vertical bars, from which
you select one.
[ x | y | ... ]
Square brackets enclose a set of optional syntax choices separated by vertical bars,
from which you select one or none.
{ x | y | ... } *
Asterisk marked braces enclose a set of required syntax choices separated by vertical
bars, from which you select a minimum of one.
[ x | y | ... ] *
Asterisk marked square brackets enclose optional syntax choices separated by vertical
bars, from which you select one choice, multiple choices, or none.
&<1-n>
The argument or keyword and argument combination before the ampersand (&) sign
can be entered 1 to n times.
# A line that starts with a pound (#) sign is comments.
GUI conventions
Convention Description
Boldface
Window names, button names, field names, and menu items are in Boldface. For
example, the
New User
window opens; click
OK
.
Convention Description
>
Multi-level menus are separated by angle brackets. For example,
File
>
Create
>
Folder
.
Symbols
Convention Description
WARNING!
An alert that calls attention to important information that if not understood or followed
can result in personal injury.
CAUTION:
An alert that calls attention to important information that if not understood or followed
can result in data loss, data corruption, or damage to hardware or software.
IMPORTANT:
An alert that calls attention to essential information.
NOTE:
An alert that contains additional or supplementary information.
TIP:
An alert that provides helpful information.
Network topology icons
Convention Description
Represents a generic network device, such as a router, switch, or firewall.
Represents a routing-capable device, such as a router or Layer 3 switch.
Represents a generic switch, such as a Layer 2 or Layer 3 switch, or a router that
supports Layer 2 forwarding and other Layer 2 features.
Represents an access controller, a unified wired-WLAN module, or the access
controller engine on a unified wired-WLAN switch.
Represents an access point.
Wireless terminator unit.
Wireless terminator.
Represents a mesh access point.
Represents omnidirectional signals.
Represents directional signals.
Represents a security product, such as a firewall, UTM, multiservice security
gateway, or load balancing device.
Represents a security module, such as a firewall, load balancing, NetStream, SSL
VPN, IPS, or ACG module.
T
T
T
T
Examples provided in this document
Examples in this document might use devices that differ from your device in hardware model,
configuration, or software version. It is normal that the port numbers, sample output, screenshots,
and other information in the examples differ from what you have on your device.
Obtaining documentation
To access the most up-to-date H3C product documentation, go to the H3C website at
http://www.h3c.com.hk
To obtain information about installation, configuration, and maintenance, click
http://www.h3c.com.hk/Technical_Documents
To obtain software version information such as release notes, click
http://www.h3c.com.hk/Software_Download
Technical support
service@h3c.com
http://www.h3c.com.hk
Documentation feedback
You can e-mail your comments about product documentation to [email protected].
We appreciate your comments.
i
Contents
Preparing for installation ···································································· 1
Safety recommendations ············································································································· 1
Safety symbols ··················································································································· 1
General safety recommendations ··························································································· 1
Electrical safety ··················································································································· 1
Laser safety ······················································································································· 2
Examining the installation site ······································································································· 2
Temperature and humidity ····································································································· 2
Cleanliness ························································································································ 2
Cooling ····························································································································· 3
ESD prevention ··················································································································· 3
EMI ·································································································································· 4
Lightning protection ············································································································· 5
Installation accessories ··············································································································· 5
Installation tools ························································································································· 6
Pre-installation checklist ·············································································································· 6
Installing the device ·········································································· 8
Confirming installation preparations ······························································································· 8
Installation flow ·························································································································· 9
Mounting the device on a workbench ····························································································· 9
Installing the device in a 19-inch rack ··························································································· 10
Mounting brackets ············································································································· 10
Mounting the device in a rack ······························································································· 10
Grounding the device ················································································································ 12
(Optional) Installing network port lightning protectors ······································································· 14
(Optional) Installing a surge protected power strip ··········································································· 15
Connecting interface cables ······································································································· 15
Connecting the console cable and setting terminal parameters ··················································· 15
Connecting Ethernet cables ································································································· 16
Installing a power module ·········································································································· 17
Connecting an AC power cord ···································································································· 18
Connecting a DC power cord ······································································································ 18
Verifying the installation ············································································································· 19
Powering on the device ············································································································· 19
Troubleshooting ············································································· 22
Power module failure ················································································································ 22
Symptom ························································································································· 22
Solution ··························································································································· 22
No display or garbled display on the configuration terminal ······························································· 22
Symptom ························································································································· 22
Solution ··························································································································· 22
Software loading failure ············································································································· 23
Symptom ························································································································· 23
Solution ··························································································································· 23
Hardware management and maintenance ··········································· 24
Displaying hardware information for the device ··············································································· 24
Displaying operational statistics for the device ········································································· 24
Displaying information about the device ················································································· 26
Displaying the electronic label data for the device ····································································· 26
Displaying the CPU usage of the device ················································································· 26
Displaying the memory usage of the device ············································································ 27
Displaying the operational status of the built-in fans ·································································· 27
Displaying the operating state of power modules ······································································ 28
Rebooting the device ················································································································ 28
ii
Restrictions and guidelines ·································································································· 28
Configuration procedure ····································································································· 29
Appendix A Chassis views and technical specifications ·························· 30
Chassis views ························································································································· 30
WX3508H ························································································································ 30
WX3510H ························································································································ 30
WX3520H ························································································································ 31
WX3540H ························································································································ 32
Power module views ················································································································· 32
AC power module ·············································································································· 32
DC power module ·············································································································· 33
Interface numbering·················································································································· 33
WX3508H ························································································································ 33
WX3510H ························································································································ 33
WX3520H and WX3540H ···································································································· 33
Technical specifications ············································································································· 34
WX3508H ························································································································ 34
WX3510H ························································································································ 34
WX3520H ························································································································ 35
WX3540H ························································································································ 35
AC power module ·············································································································· 36
DC power module ·············································································································· 36
Transceiver module, fiber connector, and optical fiber views ····························································· 36
Transceiver module specifications ······························································································· 37
Appendix B LEDs ··········································································· 42
LEDs ····································································································································· 42
LED description ······················································································································· 44
Index ··························································································· 46
1
Preparing for installation
H3C WX3500H access controllers include the following models:
WX3508H.
WX3510H.
WX3520H.
WX3540H.
Safety recommendations
To avoid any equipment damage or bodily injury, read the following safety recommendations before
installation. Note that the recommendations do not cover every possible hazardous condition.
Safety symbols
When reading this document, note the following symbols:
WARNING means an alert that calls attention to important information that if not understood or
followed can result in personal injury.
CAUTION means an alert that calls attention to important information that if not understood or
followed can result in data loss, data corruption, or damage to hardware or software.
General safety recommendations
Make sure the installation site is flat, vibration-free, and away from electromagnetic
interferences. Make sure ESD and anti-slip measures are in place.
Do not place the device on an unstable case or desk. The device might be severely damaged in
case of a fall.
Keep the chassis and installation tools away from walk areas.
Keep the chassis clean and dust-free.
Do not place the device near water or in a damp environment. Prevent water or moisture from
entering the device chassis.
Ensure good ventilation of the equipment room and keep the air inlet and outlet vents of the
device free of obstruction.
Make sure the operating voltage is in the required range.
Use a screwdriver to fasten screws.
After you move the device from a location below 0°C (32°F) to the equipment room, follow these
guidelines to prevent condensation:
{ Wait a minimum of 30 minutes before unpacking the device.
{ Wait a minimum of 2 hours before powering on the device.
Electrical safety
Carefully examine your work area for possible hazards, such as moist floors, ungrounded
power extension cables, or missing safety grounds.
2
Locate the emergency power-off switch in the room before installation. Shut off the power
immediately if an accident occurs.
Unplug all the external cables (including power cords) before moving the chassis.
Do not work alone when you operate the device with the device powered on.
Always verify that the power has been disconnected when you perform operations that require
the device to be powered off.
Laser safety
WARNING!
Do not stare into any open apertures of operating transceiver modules or optical fiber connectors.
The laser light emitted from these apertures might hurt your eyes.
CAUTION:
Before you remove the optical fiber connector from a fiber port, execute the shutdown command
in interface view to shut down the port.
Insert a dust cap into any open optical fiber connector and a dust plug into any open fiber port o
r
transceiver module port to protect them from contamination and ESD damage.
Examining the installation site
The device can only be used indoors. To ensure correct operation and a long lifespan for your device,
the installation site must meet the requirements in this section.
Temperature and humidity
Maintain the temperature and humidity in the equipment room at acceptable levels.
Lasting high relative humidity can cause poor insulation, electricity leakage, mechanical
property change of materials, and metal corrosion.
Lasting low relative humidity can cause washer contraction and ESD and bring problems
including loose captive screws and circuit failure.
High temperature can accelerate the aging of insulation materials and significantly lower the
reliability and lifespan of the switch.
To ensure correct operation of the device, the equipment room must meet the temperature and
humidity requirements listed in Table 1.
Table 1
Temperature/humidity requirements in the equipment room
Temperature Humidity
0°C to 45°C (32°F to 113°F) 5% RH to 95% RH, noncondensing
Cleanliness
Dust buildup on the chassis can result in electrostatic adsorption, which causes poor contact of metal
components and contact points, especially when indoor relative humidity is low. In the worst case,
electrostatic adsorption can cause communication failure. To ensure correct operation, the
equipment room must meet the dust concentration requirements listed in Table 2.
3
Table 2 Dust concentration limit in the equipment room
Substance Concentration limit (particles/m
3
)
Dust particles
3 x 10
4
(No visible dust on desk in three days)
NOTE:
Dust particle diameter 5 µm
To eliminate corrosion and premature aging of components, the equipment room must also meet
limits on salts, acids, and sulfides, as shown in Table 3.
Table 3
Harmful gas limits in an equipment room
Gas Max. (mg/m
3
)
SO
2
0.2
H
2
S 0.006
NH
3
0.05
Cl
2
0.01
NO
2
0.04
Cooling
The device uses left-to-right airflow. For adequate heat dissipation, make sure the following
requirements are met:
A minimum clearance of 100 mm (3.94 in) is reserved around the air vents.
The rack has a good ventilation system.
Figure 1 Airflow through the chassis (WX3508H)
ESD prevention
To prevent electrostatic discharge (ESD), follow these guidelines:
Ground the device and rack or workbench reliably.
Take dust-proof measures for the equipment room. For more information, see "Cleanliness."
4
Maintain the humidity and temperature at acceptable levels. For more information, see
"Temperature and humidity."
Before workin
g with the device, wear an ESD wrist strap or gloves and ESD garment, and
remove conductive objects such as jewelry or watch. Make sure the wrist strap makes good
skin contact and is reliably grounded.
Always remember to wear an ESD wrist strap when working with a transceiver module.
No ESD wrist strap is provided with the device. Prepare one yourself.
To attach an ESD wrist strap:
1. Wear the wrist strap on your wrist.
2. Lock the wrist strap tight around your wrist to maintain good contact with the skin.
3. Secure the wrist strap lock and the alligator clip lock together.
4. Attach the alligator clip to the rack.
5. Make sure the rack is reliably grounded.
Figure 2 Attaching an ESD wrist strap (WX3540H)
(1) ESD wrist strap (2) Lock
(3) Alligator clip
EMI
All electromagnetic interference (EMI) sources, from outside or inside of the device and application
system, adversely affect the device in the following ways:
A conduction pattern of capacitance coupling.
Inductance coupling.
Electromagnetic wave radiation.
Common impedance (including the grounding system) coupling.
To prevent EMI, perform the following tasks:
If AC power is used, use a single-phase three-wire power receptacle with protection earth (PE)
to filter interference from the power grid.
5
Keep the device far away from radio transmitting stations, radar stations, and high-frequency
devices.
Use electromagnetic shielding, for example, shielded interface cables, when necessary.
To prevent signal ports from getting damaged by overvoltage or overcurrent caused by lightning
strikes, route interface cables only indoors. If you must route interface cables outdoors, install
network port lightning protectors.
Lightning protection
To better protect the device from lightning, follow these guidelines:
Make sure the grounding cable of the chassis is reliably grounded.
Make sure the grounding terminal of the AC power receptacle is reliably grounded.
Install a lightning protector at the input end of the power module to enhance the lightning
protection capability of the power supply.
Installation accessories
The installation accessories vary by device model. Table 4 describes the installation accessories
available for the access controllers.
Table 4 Installation accessories for the access controllers
Accessory WX3508H WX3510H WX3520H WX3540H
Cage nut
4, user supplied 4, user supplied
4, user
supplied
4, user
supplied
M6 rack screw
4, user supplied 4, user supplied
4, user
supplied
4, user
supplied
M4 mounting
bracket screw
4 N/A N/A N/A
M3 mounting
bracket screw
N/A 8 8 8
Rubber feet
1 set 1 set 1 set 1 set
Grounding
cable
1 1 1 1
Console cable
1 1 1 1
AC power cord
1 N/A N/A N/A
Bail latch
1 N/A N/A N/A
6
Accessory WX3508H WX3510H WX3520H WX3540H
Front mounting bracket
× 2
× 2
×
2
×
2
Installation tools
No installation tools are provided with the device. Prepare installation tools as required.
Figure 3 Installation tools
Pre-installation checklist
Table 5 Pre-installation checklist
Item Requirements Result
Installation
site
Ventilation
There is a minimum clearance of 100 mm (3.94 in))
around the inlet and outlet vents for heat dissipation
of the device chassis.
A good ventilation system is available at the
installation site.
Temperature 0°C to 45°C (32°F to 113°F)
Humidity 5% RH to 95% RH (noncondensing)
Cleanliness
Dust concentration 3 × 10
4
particles/m
3
No dust on desk within three days
ESD prevention
The equipment and rack or workbench are reliably
grounded.
The equipment room is dust-proof.
The humidity and temperature are at acceptable
levels.
An ESD wrist strap is available.
Flathead screwdriver Phillips screwdriver Needle-nose pliers Wire-stripping pliers
Diagonal pliers Mark ESD wrist strap
7
Item Requirements Result
EMI prevention
Effective measures are taken for filtering interference
from the power grid.
The protection ground of the device is away from the
grounding facility of power equipment or lightning
protection grounding facility.
The device is far away from radio transmitting
stations, radar stations, and high-frequency devices.
Electromagnetic shielding, for example, shielded
interface cables, is used as required.
Lightning
protection
The device is reliably grounded.
The AC power source is reliably grounded.
(Optional.) Network port lightning protectors are
available.
(Optional.) A surge protected power strip is available.
Electricity safety
A UPS is available.
The power-off switch in the equipment room is
identified and accessible so that the power can be
immediately shut off when an accident occurs.
Rack-mounting
requirements
The rack has a good ventilation system.
The rack is sturdy enough to support the weight of
the device and installation accessories.
The size of the rack is appropriate for the device.
The front and rear of the rack are a minimum of 0.8 m
(31.50 in) away from walls or other devices.
Safety
precautions
The device is far away from any moist area and heat source.
You have located the emergency power switch in the equipment room.
Accessories Accessories provided with the device are available.
Reference
Documents shipped with the device are available.
Online documents are available.
8
Installing the device
WARNING!
Keep the tamper-proof seal on a mounting screw on the chassis cover intact, and if you want to open
the chassis, contact H3C Support for permission. Otherwise, H3C will not be liable for any
consequence caused thereby.
Confirming installation preparations
Before you install the device, verify that you have read "Preparing for installation" carefully and the
installation site meets all the requirements.
9
Installation flow
Figure 4 Installation flow
Mounting the device on a workbench
CAUTION:
Do not place heavy objects on the device.
If a standard 19-inch rack is not available, you can mount the device on a clean, flat workbench.
To mount the device on a workbench:
10
1. Place the device upside down. Clean the recessed areas on the chassis bottom.
2. Attach the four rubber feet to the recessed areas on the chassis bottom.
3. Place the device on the workbench with the upside up. Make sure the four rubber feet stand
firmly on the workbench.
Figure 5 Mounting the device on a workbench (WX3508H)
Installing the device in a 19-inch rack
IMPORTANT:
Keep a minimum distance of 1 U (44.45 mm, or 1.75 in) between devices in a rack for good heat
dissipation.
Mounting brackets
The available mounting brackets vary by device model. Table 6 describes the mounting brackets
available for the access controllers.
Table 6 Mounting brackets available for the access controllers
Device model Mounting bracket
WX3508H
WX3510H
WX3520H
WX3540H
Mounting the device in a rack
1. Attach cage nuts to the front rack posts:
a. Wear the ESD wrist strap and make sure the rack is sturdy and is reliably grounded.
11
b. Use a mounting bracket to mark cage nut installation positions on the two front rack posts.
c. Install cage nuts into the marked square holes on the front rack posts.
Figure 6 Installing cage nuts
2. Use the screws supplied with the mounting brackets to secure the mounting brackets to both
sides of the device.
Figure 7 Installing the mounting brackets (WX3508H)
3. Supporting the device bottom with one hand and holding the device front with the other, place
the device gently in the rack. Use M6 rack screws to attach the mounting brackets on the device
to the front rack posts.
12
Figure 8 Installing the device in the rack (WX3508H)
Grounding the device
WARNING!
Correctly connecting the grounding cable is crucial to lightning protection and EMI protection.
Connect the grounding cable to the grounding system in the equipment room. Do not connect it
to a fire main or lightning rod.
To ground the device:
1. Use a Phillips screwdriver to remove the grounding screw from the chassis.
2. Use the grounding screw to attach the ring terminal of the grounding cable to the chassis.
3. Connect the other end of the grounding cable according to the grounding method you use:
{ Grounding the device with a grounding strip—If a grounding strip is available at the
installation site, connect the other end of the grounding cable to the grounding strip and
make sure the grounding strip has been reliably grounded.
13
Figure 9 Grounding the device with a grounding strip (WX3508H)
{ Grounding the device with the rack—Connect the other end of the grounding cable to the
grounding point on the rack and make sure the rack has been reliably grounded.
Figure 10 Grounding the device with the rack (WX3508H)
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56

H3C WX3508H Installation guide