Rosemount 4088 Transmitter Utility Upgrade User manual

Type
User manual
Manual Supplement
00809-0300-4088, Rev BA
November 2018
Rosemount
4088 Transmitter Utility Upgrade
User Manual
Installation and user guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 1
What update was made to the firmware? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 1
Upgrade utility release information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 2
System requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 2
Hardware requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 2
Connecting to the transmitter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 2
Using the upgrade utility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 3
Technical support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 4
1.0 Installation and user guide
This guide provides information required to install and use the Rosemount
4088 Firmware Upgrade
Utility.
2.0 What update was made to the firmware?
As of January 5th, 2018, the Rosemount 4088 firmware was updated from firmware revision 5 to revision
6. Firmware revision 6 has updated the default damping on process temperature from five seconds to
two seconds, allowing for faster temperature measurement response times as well as reduced
calibration time required. Firmware revision 6 also enhanced the calibration process between Emerson
flow computers and the Rosemount 4088 transmitter, creating tighter integration and reduced
maintenance time.
NOTICE
Per the license agreement, do not share this tool, with anyone outside your organization. If you do
share the tool with others within your organization, let any additional users know that this tool is
proprietary and absolutely cannot be shared outside of the organization.
2
Manual Supplement
00809-0300-4088, Rev BA
Rosemount 4088 Transmitter Utility Upgrade User Manual
2018
Rosemount 4088 Transmitter Utility Upgrade User Manual
3.0 Upgrade utility release information
Utility version: 1.0.0.5
Released date: January, 2018
Released by: Emerson
4.0 System requirements
Microsoft
®
Windows
7 Operating System (32 or 64 bit)
5.0 Hardware requirements
Serial to RS-485 Modem (computer must have serial port)
If computer does not have a serial port, a USB to serial modem converter must be used.
The tool may work with many different modems and converters, but all testing at Rosemount was
completed with the following modems:
Modem 1: Rosemount serial to RS-485 modem, Part # 03095-5106-0002
Modem 2: B&B Electronics, Model 485SD9TB
6.0 Connecting to the transmitter
To ensure there are no connection interruptions, the Rosemount 4088 communications should be
isolated from any other transmitter or flow computer when the firmware flash is in process.
Connect a reliable power source to the PWR (+) and (-) terminals on the transmitter.
Connect the communication leads from the modem to the RS-485 (A) and (B) terminals of the
transmitter.
Transmitter covers should not be removed in explosion-proof areas with power applied.
3
Manual Supplement
00809-0300-4088, Rev BA
Rosemount 4088 Transmitter Utility Upgrade User Manual
2018
Rosemount 4088 Transmitter Utility Upgrade User Manual
7.0 Using the upgrade utility
1. Enter the Modbus
®
address for the transmitter.
2. Ensure the baud rate in the transmitter and utility tool match.
3. Select the proper serial port on your PC.
4. Select the Flash button.
Each transmitter will take about 10 minutes to upgrade at 9600 Baud.
Device configuration and calibration will be maintained throughout the update process, so there is
no need to recalibrate or reconfigure after the update completes.
7.1 Error message
If an error message is received during the upgrade process, it will appear as follows.
4
Manual Supplement
00809-0300-4088, Rev BA
Rosemount 4088 Transmitter Utility Upgrade User Manual
2018
Rosemount 4088 Transmitter Utility Upgrade User Manual
If this happens, ensure the transmitter communication is isolated, the power supply is providing
sufficient power, all connections are good, and simply start the upgrade process over.
8.0 Technical support
If issues arise during upgrade, contact your local Emerson sales representative for help or answers to
your questions.
5
Manual Supplement
00809-0300-4088, Rev BA
Rosemount 4088 Transmitter Utility Upgrade User Manual
2018
Rosemount 4088 Transmitter Utility Upgrade User Manual
Manual Supplement
00809-0300-4088, Rev BA
November 2018
Global Headquarters
Emerson Automation Solutions
6021 Innovation Blvd.
Shakopee, MN 55379, USA
+1 800 999 9307 or +1 952 906 8888
+1 952 949 7001
RFQ.RMD-RCC@Emerson.com
North America Regional Office
Emerson Automation Solutions
8200 Market Blvd.
Chanhassen, MN 55317, USA
+1 800 999 9307 or +1 952 906 8888
+1 952 949 7001
RMT-NA.RCCRFQ@Emerson.com
Latin America Regional Office
Emerson Automation Solutions
1300 Concord Terrace, Suite 400
Sunrise, FL 33323, USA
+1 954 846 5030
+1 954 846 5121
RFQ.RMD-RCC@Emerson.com
Europe Regional Office
Emerson Automation Solutions Europe GmbH
Neuhofstrasse 19a P.O. Box 1046
CH 6340 Baar
Switzerland
+41 (0) 41 768 6111
+41 (0) 41 768 6300
RFQ.RMD-RCC@Emerson.com
Asia Pacific Regional Office
Emerson Automation Solutions
1 Pandan Crescent
Singapore 128461
+65 6777 8211
+65 6777 0947
Middle East and Africa Regional Office
Emerson Automation Solutions
Emerson FZE P.O. Box 17033
Jebel Ali Free Zone - South 2
Dubai, United Arab Emirates
+971 4 8118100
+971 4 8865465
RFQ.RMTMEA@Emerson.com
Linkedin.com/company/Emerson-Automation-Solutions
Twitter.com/Rosemount_News
Facebook.com/Rosemount
Youtube.com/user/RosemountMeasurement
Google.com/+RosemountMeasurement
Emerson Terms and Conditions of Sale are available upon request.
The Emerson logo is a trademark and service mark of Emerson Electric Co.
Rosemount is a mark of one of the Emerson family of companies. All other
marks are the property of their respective owners.
© 2018 Emerson. All rights reserved.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6

Rosemount 4088 Transmitter Utility Upgrade User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI