Fixture Diagram
Parts List
Cauons
CAUTION – RISK OF SHOCK –
Disconnect Power at the main circuit breaker panel or main
fusebox before starng and during the installaon.
WARNING:
This xture is intended for installaon in accordance
with the Naonal Electrical Code (NEC) and all local code
specicaons. If you are not familiar with code requirements,
installaon by a cered electrician is recommended.
CLEANING:
Always be certain that electric current is turned o before
cleaning.
• Only a so damp cloth should be used. Harsh cleaning
products may damage the nish.
[A] Mounting
Strap
[B] Outlet Box
[C] Mounting
Screws
[D] Canopy
[E] Strap
Mounting
Screws
[F] Knobs
[G] Lockwasher
[H] Cable
1) Find the appropriate threaded holes on mounng
strap[A] that align with hole distance in canopy[D]
Thread mounng screws[C] into threaded holes starng
from outlet box[B] side.
2) Aach mounng strap[A] to outlet box[B] using the
strap mounng screws[E]. Mounng strap can be
adjusted to suit posion of xture.
3) Adjust the cable[H] to the desired length by loosening
the screw in the strain reliefs on the boom of the
canopy[D] and pushing the cable up into the canopy.
Once the desired length is achieved ghten the loose
screws.
4) Grounding instrucons: (See Illus. a or b).
a) On xtures where mounng strap is provided with a
hole and two raised dimples, wrap ground wire from
outlet box around green ground screw, and thread
into hole.
b) On xtures where a cupped washer is provided,
aach ground wire from outlet box under cupped
washer and green ground screw, and thread into
mounng strap.
If xture is provided with ground wire, connect xture
ground wire to outlet box ground wire with wire
connector aer following the above steps. Never connect
ground wire to black or white power supply wires.
5) Make wire connecons. Reference chart below for
correct connecons and wire accordingly.
Connect Black or Red
Supply Wire to:
Connect White Supply
Wire to:
Black White
*Parallel cord (round &
smooth)
*Parallel cord (square &
ridged)
Clear, Brown, Gold or
Black without Tracer
Clear, Brown, Gold or Black
with Tracer
Insulated wire (other
than green) with copper
conductor
Insulated wire (other
than green) with silver
conductor
*Note: When parallel wire (SPT
1 & SPT 2) are used. The neutral
wire is square shaped or ridged
and the other wire will be round
in shape or smooth (See illus.)
Neutral Wire
6) Push xture to ceiling, carefully passing mounng screws
through holes in canopy[D]. NOTE: Be certain wires do
not get pinched between canopy and ceiling.
7) Use knobs[F] and lockwashers[G] to secure canopy.
Tighten to secure.
8) Insert recommended bulb (not supplied).
GREEN GROUND
SCREW
CUPPED
WASHER
OUTLET BOX
GROUND
FIXTURE
GROUND
DIMPLES
WIRE CONNECTOR
OUTLET BOX
GROUND
GREEN GROUND
SCREW
FIXTURE
GROUND
a
b