Dacor ER30G, dacor er30g User manual

  • Hello! I am an AI chatbot trained to assist you with the Dacor ER30G User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
  • What is the product width?
    What is the overall depth of the range?
    What are the electrical requirements?
    Where can I find utility connections?
    What are the gas supply pressure requirements for natural gas?
    What are the gas supply pressure requirements for LP gas?
    Where is the gas connection located?
    What is the minimum cabinet depth?
    What is the maximum cabinet depth?
PLANNING
GUIDE
Web: http://www.Dacor.com
Corporate Phone: 800-793-0093
Specifications are subject to change without notice.
See installation instructions for additional details.
5.5
30” Wide, Epicure™
All Gas Range
ER30G
1/2
Revised
10/08/08
WARNING
Observe all governing codes and ordinances during ◊
planning and installation. Contact your local building
department for further information.
This appliance must be installed in accordance with the ◊
accompanying installation instructions.
All tolerances +1/16” -0 (+1.6 mm, 0) unless otherwise noted.
1 1/16” (27mm)
1 9/16”
(40mm)
Front of open door
Front of handle
Front edge of bullnose
Front panel
Rear of front panel
Backguard
thickness
26 1/16” (662mm)
27” (686mm)
28 1/2” (724mm)
23 15/16” (608mm)
3” (76mm)
Backguard**
6” (152mm)
Backguard*
** Optional
* Standard
35”
(889mm)
to
37 1/8”
(943mm)
9” (229mm)
Backguard**
45 1/2” (1156mm)
ER30G
OVERALL DEPTH DIMENSIONS
SIDE VIEW
Product Width: 29 7/8” (759mm)
Range Model
Electrical
Circuit
Required
Total
Connected
Load
ER30G 240 Vac,
60 Hz, 15 Amp
0.5 kW
(4.0 Amp)
ELECTRICAL REQUIREMENTS
PLANNING
GUIDE
Web: http://www.Dacor.com
Corporate Phone: 800-793-0093
Specifications are subject to change without notice.
See installation instructions for additional details.
5.6
30” Wide, Epicure™
All Gas Range
ER30G
2/2
Revised
10/08/08
All tolerances +1/16” -0 (+1.6 mm, 0) unless otherwise noted.
NOTES:
1. Utilities may be located in the lower left
corner of the adjacent right cabinet.
(Recommended)
2. Contact your local building department
to verify compliance with local code
interpretation.
Model Number “A” “B”
ER30G 30 1/16” (764mm)
30” (762mm) Minimum
36” (914mm) Recommended
**
** Cabinet depth is at discretion of customer
but cabinet face MUST NOT protrude further
than rear of front panel, see product dimesions
*** Consult local code for exact location
requirements.
* Vertical to combustible surface
B
A
Non-Combustible
surface along
back wall
recommended
Suggested
location of
utilities***
30” (762mm)
min.*
CUTOUT DIMENSIONS
12 1/2”
(31.8 cm)
to
14 5/8”
(37.1 cm)
2 5/8”
(66.7 cm)
BACK OF RANGE
GAS SUPPLY PRESSURE REQUIREMENTS
Gas
Type
Manifold
Pressure* (WC)
Min. Gas Supply
Pressure (WC)
Max. Input
Pressure
Natural 5” 6” 1/2 p.s.i.
LP 10” 11” 1/2 p.s.i.
IMPORTANT: The information above is for reference only. If the
above data does not agree with the product data label, use the
data on the product data label on top of the kick plate below the
door (remove the door according to the installation instructions to
view it).
The gas connection is located on the back of the unit as shown.
/