Dacor REMP16 Planning Guides

Type
Planning Guides

Dacor REMP16 is a powerful remote blower designed for use with downdraft vents or hoods. It features a galvanized finish that can be painted to match your kitchen décor. The REMP16 has a maximum duct length of 33 1/2 inches and a total connected load of 2.7 amps. It operates on a 120-volt power supply and delivers an impressive airflow of 1000 CFM (nominal) and 994.8 CFM (actual). With its efficient performance and durable construction, the REMP16 is the ideal choice for demanding ventilation needs.

Dacor REMP16 is a powerful remote blower designed for use with downdraft vents or hoods. It features a galvanized finish that can be painted to match your kitchen décor. The REMP16 has a maximum duct length of 33 1/2 inches and a total connected load of 2.7 amps. It operates on a 120-volt power supply and delivers an impressive airflow of 1000 CFM (nominal) and 994.8 CFM (actual). With its efficient performance and durable construction, the REMP16 is the ideal choice for demanding ventilation needs.

All specications subject to change without notice.
Phone: (800) 793-0093www.dacor.com
PLANNING
GUIDE
REMP3, REMP16
Renaissance
®
Remote Blowers
Document # PG09-003
Revised 10/16/13 Page 1/3
REMP3 OVERALL DIMENSIONS
(TOP AND SIDE VIEWS)
17 3/8” (44.1 cm)
19” (48.3 cm)
24 1/4”
(61.6 cm)
3 5/8”
(9.2 cm)
2 1/8”
(5.4 cm)
9 1/4”
(23.5 cm)
Mounting
flange
25 1/2”
(64.8 cm)
7 1/2”
(19.1 cm)
4”
(10.2 cm)
9 1/2” (24.1 cm)
Exhaust
Cutout location
11” W x 12 5/8” H
(27.9 cm X 32.1 cm)
Intake collar
Power supply
conduit hole
C
L
C
L
C
L
C
L
5 13/16”
(14.8 cm)
8” Nom.
(20.3 cm)
7 15/16”
(20.2 cm)
Discharge
Intake collar
REMP16 OVERALL DIMENSIONS
(TOP AND SIDE VIEWS)
26” (66.0 cm)
32 1/4”
(81.9 cm)
3 5/8”
(9.2 cm)
2 1/8”
(5.4 cm)
12 1/4”
(31.1 cm)
Mounting
flange
33 1/2”
(85.1 cm)
9 1/2”
(24.1 cm)
4”
(10.2 cm)
13 1/8
(33.3 cm)
Exhaust
Cutout location
13” W X 16 5/8” H
(33.0 cm X 42.2 cm)
Intake collar
Power supply
conduit
location
C
L
C
L
C
L
C
L
24 1/4” (61.6 cm)
9 9/16”
(24.3 cm)
10” Nom.
(25.4 cm)
11 1/2”
(29.2 cm)
Discharge
Intake collar
± 1/16” (± 1.6 mm) unless otherwise stated
Model No.
Electrical Supply
Requirements
Maximum Duct
Length
Total Connected
Load
Blower Rating*
Approximate
Shipping Weight
Finish
REMP3
Refer to downdraft
vent or hood
specications
Refer to downdraft
vent or hood speci-
cations
120 Vac, 3.8 Amp.
600 CFM (nominal)
620.5 CFM (actual)
35 lbs.
Galvanized
(may be painted)
REMP16 120 Vac, 2.7 Amp.
1000 CFM (nominal)
994.8 CFM (actual)
55 lbs.
* At 0" static pressure
WARNING
• Observe all governing codes and ordinances
during planning and installation. Contact your
local building department for further information.
• This appliance must be installed in accordance
with the hood or downdraft vent system
installation instructions.
All specications subject to change without notice.
Phone: (800) 793-0093www.dacor.com
PLANNING
GUIDE
REMP3, REMP16
Renaissance
Remote Blowers
Document # PG09-003
Revised 10/16/13 Page 2/3
Airflow CFM (Cubic feet/minute)
Static pressure - inches of water
0
1.0
2.0
3.0
4.0
5.0
100 200 300 400 500 600 700
REMP3 Blower Performance
Airflow CFM (Cubic feet/minute)
Static pressure - inches of water
0
0.5
1.0
1.5
2.0
2.5
200 400 600 800 1000
REMP16 Blower Performance
All specications subject to change without notice.
Phone: (800) 793-0093www.dacor.com
PLANNING
GUIDE
REMP3, REMP16
Renaissance
Remote Blowers
Document # PG09-003
Revised 10/16/13 Page 3/3
Blower
Roof
Exhaust
Blower
Duct
Wiring/conduit
Wiring/conduit
Duct
Wall
No obstructions
within 15 inches of exhaust
Exhaust
Blower
discharge
Roof curb
Prevailing
wind
REMP FLAT ROOF INSTALLATION
TOP AND SIDE VIEWS (SEE NOTE 2)
25 1/2"
(64.8 cm)
2"
(5.1 cm)
19"
(48.3 cm)
23 ¼"
(59.1 cm)
6"
(15.2 cm)
2"
(5.1 cm)
REMP3
ROOF CURB DIMENSIONS
NOTE:
1. The REMP chassis may be rotated to clear obstructions. 15” (38.1 cm) min. clearance must be maintained from the air
discharge to any obstruction. In cold climates, take into account snow accumulation which can also act as an obstruction.
2. When mounting in a horizontal position, shield the REMP to protect from possible water collection in the chassis. Maintain
a minimum down slope of 1/4” (6 mm) per foot for evacuation of water.
3. When the REMP is installed on to a flat (less than a 2:12 pitch) roof, a roof curb is required.
4. The blower discharge must be pointed in the same direction as the prevailing wind.
EXAMPLE REMP
WALL INSTALLATION
SIDE VIEW
(EXHAUST MUST
POINT DOWN)
33 1/2”
(85.1 cm)
2”
(5.1 cm)
26"
(66.0 cm)
30 1/2”
(77.6 cm)
6”
(15.2 cm)
2”
(5.1 cm)
REMP16
ROOF CURB DIMENSIONS
+/- 1/16” (+/- 1.6 mm) unless otherwise stated
EXAMPLE REMP
ROOF INSTALLATION
SIDE VIEW
  • Page 1 1
  • Page 2 2
  • Page 3 3

Dacor REMP16 Planning Guides

Type
Planning Guides

Dacor REMP16 is a powerful remote blower designed for use with downdraft vents or hoods. It features a galvanized finish that can be painted to match your kitchen décor. The REMP16 has a maximum duct length of 33 1/2 inches and a total connected load of 2.7 amps. It operates on a 120-volt power supply and delivers an impressive airflow of 1000 CFM (nominal) and 994.8 CFM (actual). With its efficient performance and durable construction, the REMP16 is the ideal choice for demanding ventilation needs.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI