All specications subject to change without notice.
Phone: (800) 793-0093www.dacor.com
PLANNING
GUIDE
REMP3, REMP16
Renaissance
Remote Blowers
Document # PG09-003
Revised 10/16/13 Page 3/3
Blower
Roof
Exhaust
Blower
Duct
Wiring/conduit
Wiring/conduit
Duct
Wall
No obstructions
within 15 inches of exhaust
Exhaust
Blower
discharge
Roof curb
Prevailing
wind
REMP FLAT ROOF INSTALLATION
TOP AND SIDE VIEWS (SEE NOTE 2)
25 1/2"
(64.8 cm)
2"
(5.1 cm)
19"
(48.3 cm)
23 ¼"
(59.1 cm)
6"
(15.2 cm)
2"
(5.1 cm)
REMP3
ROOF CURB DIMENSIONS
NOTE:
1. The REMP chassis may be rotated to clear obstructions. 15” (38.1 cm) min. clearance must be maintained from the air
discharge to any obstruction. In cold climates, take into account snow accumulation which can also act as an obstruction.
2. When mounting in a horizontal position, shield the REMP to protect from possible water collection in the chassis. Maintain
a minimum down slope of 1/4” (6 mm) per foot for evacuation of water.
3. When the REMP is installed on to a flat (less than a 2:12 pitch) roof, a roof curb is required.
4. The blower discharge must be pointed in the same direction as the prevailing wind.
EXAMPLE REMP
WALL INSTALLATION
SIDE VIEW
(EXHAUST MUST
POINT DOWN)
33 1/2”
(85.1 cm)
2”
(5.1 cm)
26"
(66.0 cm)
30 1/2”
(77.6 cm)
6”
(15.2 cm)
2”
(5.1 cm)
REMP16
ROOF CURB DIMENSIONS
+/- 1/16” (+/- 1.6 mm) unless otherwise stated
EXAMPLE REMP
ROOF INSTALLATION
SIDE VIEW