Kelvinator Q6SE, Single Phase Product information

Type
Product information

This manual is also suitable for

1
2
3
4
5
6
7
8
9
G
C
A1
W1
R
Y2
E
O Y1
W2
L1
L2
T1T2
C
R
S
R
C
S
T2
T1
N
G
L
C
T3
T4
T5
TO 208/230 VAC
POWER SUPPLY
9
8
1
7
6
5
4
3
2
9
8
1
7
6
5
4
3
2
9
8
1
7
6
5
4
3
2
9
8
1
7
6
5
4
3
2
COMPRESSOR
COMPRESSOR
DUAL CAPACITOR
HEATER
PLUG
OUTDOOR
FAN MOTOR
DEFROST
SENSOR
ECONOMIZER
PLUG
ECONOMIZER
PLUG
TO DISCHARGE
AIR SENSOR
3 AMP
FUSE
BLOWER
RELAY
BLOWER
MOTOR
BLACK
YELLOW
RED
YE
YE
YE
CONTACTOR
FH
C
24V
TRANSFORMER
240V
208V
COM
1
5
2
6
3
4
BLUE
ORANGE
FIELD WIRING
LEGEND:
LOW VOLTAGE
HIGH VOLTAGE
CCH
BLACK
BLACK
AMBIENT
SENSOR
M
PRESS
SW
REV
VALVE
AMBIENT
AMBG
COILG
COIL
L
DEMAND
DEFROST
BOARD
R CYO
W2-IN
W2-OUT
COND FAN
BLACK
BLACK
REVERSING
VALVE SOLENOID
24VDC OUTPUT TO A COMPATIBLE
THERMOSTAT
SEE II FOR DETAILS
BLACK
OPTIONAL
ODT(HUD
APPLICATIONS)
208/230 VoltConvertible Packaged Heat Pump Single Phase 60Hz
NOTES:
1. Disconnect all power before servicing.
2. For supply connections use copper conductors only.
3. Not suitable on systems that exceed 150V to ground.
4. If any of the original wire as supplied with the furnace
must be replaced, it must be replaced with wiring
material having a temperature rating of at least 105°C.
5. For supply wire ampacities overcurrent protection, see
unit rating plate.
6. For HUD installations only. See installation instructions
in the branding kit.
1. Couper le courant avant de faire letretien.
2. Employez uniquement des conducteurs en cuivre.
3. Ne convient pas aux installations de plus de 150 V
a la terre.
10214950
(Replaces 1006497A)
04/18
NOTE: See Installation
Instructions for wiring,
application, and
Information concerning
accessory Heat Kits and
other options.
WIRING DIAGRAM
DEFROST BOARD OPERATION:
Heat Pump operates in heating mode until the combination of outdoor ambient and outdoor coil temperatures initiate
a defrost cycle. The outdoor coil temperature must be at or below 32°F before the defrost cycle begins.
There must be a minimum of 20 minutes between defrost cycles. After this time, temperature conditions must call for
defrost continuously for 4 1/2 minutes before a defrost cycle is initiated.
The defrost cycle ends when the outdoor temperature reaches 32°F or the defrost terminate time of 13 minutes 39
seconds is reached.
1
2
3
RED
RED
WHITE
YELLOW
BLUE
YELLOW
BLACK
GRAY
GREEN
GREEN
ORANGE
GREEN
BLACK
GRAY
YELLOW
BLUE
YELLOW
RED
RED
HIGH
PRESSURE
SWITCH
LOW PRESSURE
SWITCH
(SELECT MODELS)
GN WITH YE STRIPE
BLACK
ORANGE
YELLOW
RED
RED
BROWN
BROWN
ORANGE
WHITE
WHITE
WHITE
YELLOW
BLUE
YELLOW
BLACK
BLACK
BLACK
BLACK
RED
RED
BLACK
WHITE
RED
RED
YELLOW
GRAY
YELLOW
YELLOW
ORANGE
SEE NOTE 6