Mobicool COOL BOXES – Mobile Refrigerating Appliance User manual

Category
Cool boxes
Type
User manual

This manual is also suitable for

mobicool.com
Mobile refrigerating appliance
Operating manual . . . . . . . . . . . . . . 5
Mobiles Kühlgerät
Bedienungsanleitung. . . . . . . . . . . 21
Appareil de réfrigération mobile
Notice d’utilisation . . . . . . . . . . . . . 38
Aparato móvil de refrigeración
Instrucciones de uso . . . . . . . . . . . 55
Apparecchio di refrigerazione
mobile
Istruzioni per l’uso. . . . . . . . . . . . . . 72
Mobiel koelapparaat
Gebruiksaanwijzing . . . . . . . . . . . . 89
Transportabelt køle-/
fryseapparat
Betjeningsvejledning . . . . . . . . . . 106
Mobil kyl-/frysprodukt
Bruksanvisning . . . . . . . . . . . . . . . .121
Mobil kjøleboks
Bruksanvisning . . . . . . . . . . . . . . . 136
Siirrettävä kylmäsäilytyslaite
Käyttöohje. . . . . . . . . . . . . . . . . . . .152
Aparelho de refrigeração móvel
Manual de instruções . . . . . . . . . .168
Мобильное охлаждающее
устройство
Инструкция по эксплуатации . . 185
Przenośne urządzenie
chłodnicze
Instrukcja obsługi. . . . . . . . . . . . . 203
Mobilní chladicí spotřebič
Návod k obsluze . . . . . . . . . . . . . 220
Mobilný chladiaci spotrebič
Návod na obsluhu. . . . . . . . . . . . 235
Mobil hűtőkészülék
Használati utasítás . . . . . . . . . . . .251
EN
DE
FR
ES
IT
NL
DA
SV
NO
FI
PT
RU
PL
CS
SK
HU
COOL BOXES
MCF32, MCF40, MCF60, FR40 AC/DC
FR34-FR40-FR60_MCF32-MCF40-MRF40-MCF60_OPM_EMEA16.book Seite 1 Mittwoch, 23. Dezember 2020 3:42 15
© 2020 Dometic Group. The visual appearance of the contents of this manual is
protected by copyright and design law. The underlying technical design and the
products contained herein may be protected by design, patent or be patent
pending. The trademarks mentioned in this manual belong to Dometic Sweden AB.
All rights are reserved.
FR34-FR40-FR60_MCF32-MCF40-MRF40-MCF60_OPM_EMEA16.book Seite 2 Mittwoch, 23. Dezember 2020 3:42 15
EN
MCF32, MCF40, MCF60, FR40 AC/DC
5
Please read these instructions carefully and follow all instructions, guidelines, and warnings included in this product manual in order to ensure
that you install, use, and maintain the product properly at all times. These instructions MUST stay with this product.
By using the product, you hereby confirm that you have read all instructions, guidelines, and warnings carefully and that you understand and
agree to abide by the terms and conditions as set forth herein. You agree to use this product only for the intended purpose and application
and in accordance with the instructions, guidelines, and warnings as set forth in this product manual as well as in accordance with all appli-
cable laws and regulations. A failure to read and follow the instructions and warnings set forth herein may result in an injury to yourself and
others, damage to your product or damage to other property in the vicinity. This product manual, including the instructions, guidelines, and
warnings, and related documentation, may be subject to changes and updates. For up-to-date product information, please visit
www.dometic.com.
Contents
1 Explanation of symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
2 Safety instructions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
3 Scope of delivery. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
4 Intended use. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
5 Function description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
5.1 Scope of functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
5.2 Operating and display elements . . . . . . . . . . . . . . . . . . . . . . . . . . 10
6 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
6.1 Before initial use. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
6.2 Saving energy. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
6.3 Connecting the cooling device . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
6.4 Using the battery monitor. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
6.5 Using the cooling device . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
6.6 Latching the cooling device lid . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
6.7 Setting the temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
6.8 Switching off the cooling device . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
6.9 Using the interior light (only MCF60) . . . . . . . . . . . . . . . . . . . . . . . 16
6.10 Defrosting the cooling device . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
6.11 Replacing the fuse. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
7 Cleaning and maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
8 Guarantee. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
9 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
FR34-FR40-FR60_MCF32-MCF40-MRF40-MCF60_OPM_EMEA16.book Seite 5 Mittwoch, 23. Dezember 2020 3:42 15
EN
Explanation of symbols MCF32, MCF40, MCF60, FR40 AC/DC
6
10 Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
11 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
1 Explanation of symbols
!
!
A
I
2Safety instructions
!
WARNING! Failure to obey these warnings could result in death
or serious injury.
Electrocution hazard
Do not operate the cooling device if it is visibly damaged.
If this cooling device's power cable is damaged, it must be
replaced to prevent safety hazards.
This cooling device may only be repaired by qualified personnel.
Improper repairs can lead to considerable hazards.
Fire hazard
When positioning the device, ensure the supply cord is not
trapped or damaged.
Do not locate multiple portable socket-outlets or portable power
supplies at the rear of the device.
WARNING!
Safety instruction: Indicates a hazardous situation that, if not
avoided, could result in death or serious injury.
CAUTION!
Safety instruction: Indicates a hazardous situation that, if not
avoided, could result in minor or moderate injury.
NOTICE!
Indicates a situation that, if not avoided, can result in property
damage.
NOTE
Supplementary information for operating the product.
FR34-FR40-FR60_MCF32-MCF40-MRF40-MCF60_OPM_EMEA16.book Seite 6 Mittwoch, 23. Dezember 2020 3:42 15
EN
MCF32, MCF40, MCF60, FR40 AC/DC Safety instructions
7
Health hazard
This device can be used by children aged from 8 years and
above and persons with reduced physical, sensory or mental
capabilities or lack of experience and knowledge if they have
been given supervision or instruction concerning use of the
device in a safe way and understand the hazards involved.
Children shall not play with the device.
Cleaning and user maintenance shall not be made by children
without supervision.
Children aged from 3 to 8 years are allowed to load and unload
cooling devices.
Explosion hazard
Do not store any explosive substances such as spray cans with
a flammable propellant in the cooling device.
!
CAUTION! Failure to obey these cautions could result in minor
or moderate injury.
Electrocution hazard
Before starting the cooling device, ensure that the power supply
line and the plug are dry.
Disconnect the cooling device from the power supply
before each cleaning and maintenance
after every use
Health hazard
Please check if the cooling capacity of the device is suitable for
storing the food or medicine you wish to cool.
Food may only be stored in its original packaging or in suitable
containers.
Opening the cooling device for long periods can cause signifi-
cant increase of the temperature in the compartments of the
device.
Clean regularly surfaces that can come in contact with food and
accessible drainage systems.
FR34-FR40-FR60_MCF32-MCF40-MRF40-MCF60_OPM_EMEA16.book Seite 7 Mittwoch, 23. Dezember 2020 3:42 15
EN
Safety instructions MCF32, MCF40, MCF60, FR40 AC/DC
8
If the device is left empty for long periods:
Switch off the device.
Defrost the device.
Clean and dry the device.
Leave the lid open to prevent mould developing within the
device.
A
NOTICE! Damage hazard
Check that the voltage specification on the type plate
corresponds to that of the energy supply.
Only connect the cooling device as follows:
With the DC connection cable to a DC power supply in the
vehicle
Or with the AC connection cable to an AC power supply
Never pull the plug out of the socket by the cable.
If the cooling device is connected to a DC outlet: Disconnect the
cooling device and other power consuming devices from the bat-
tery before connecting a quick charging device.
If the cooling device is connected to a DC outlet: Disconnect the
cooling device or switch it off when you turn off the engine.
Otherwise you may discharge the battery.
The cooling device is not suitable for transporting caustic
materials or materials containing solvents.
The insulation of the cooling device contains flammable cyclo-
pentane and requires special disposal procedures. Deliver the
cooling device at the end of its life-cycle to an appropriate
recycling center.
Do not use electrical devices inside the cooling device unless
they are recommended by the manufacturer for the purpose.
Do not place the cooling device near naked flames or other heat
sources (heaters, direct sunlight, gas ovens etc.).
Risk of overheating!
Ensure at all times that there is a minimum of 50 mm ventilation
on all four sides of the cooling device. Keep the ventilation area
free of any objects that could restrict the air flow to the cooling
components.
Do not place the cooling device in closed compartments or
areas with none or minimal air flow.
Ensure that the ventilation openings are not covered.
Do not fill the inner container with ice or fluids.
FR34-FR40-FR60_MCF32-MCF40-MRF40-MCF60_OPM_EMEA16.book Seite 8 Mittwoch, 23. Dezember 2020 3:42 15
EN
MCF32, MCF40, MCF60, FR40 AC/DC Scope of delivery
9
Never immerse the cooling device in water.
Protect the cooling device and cables against heat and moisture.
The device shall not to be exposed to rain.
3Scope of delivery
4 Intended use
The cooling box is suitable for cooling food. The cooling box is also suitable
for use on vehicles. The cooling box is designed to be operated from a DC
power supply socket of a vehicle or from an AC power supply.
The cooling box is suitable for camping use.
The cooling box is not suitable for:
storage of corrosive, caustic or solvent-containing substances
freezing of food
This cooling box is not intended to be used as a built-in appliance.
This cooling box is only suitable for the intended purpose and application in
accordance with these instructions.
This manual provides information that is necessary for proper installation and/
or operation of the cooling box. Poor installation and/or improper operating or
maintenance will result in unsatisfactory performance and a possible failure.
The manufacturer accepts no liability for any injury or damage to the product
resulting from:
Incorrect assembly or connection, including excess voltage
Incorrect maintenance or use of spare parts other than original spare parts
provided by the manufacturer
Quantity Description
1 Compressor cooler
1 DC connection cable
1 AC connection cable
1 Operating manual
FR34-FR40-FR60_MCF32-MCF40-MRF40-MCF60_OPM_EMEA16.book Seite 9 Mittwoch, 23. Dezember 2020 3:42 15
EN
Function description MCF32, MCF40, MCF60, FR40 AC/DC
10
Alterations to the product without express permission from the manufac-
turer
Use for purposes other than those described in this manual
Dometic reserves the right to change product appearance and product
specifications.
5 Function description
The cooling device can chill products, keep them cool.
A low maintenance refrigerant circuit with compressor provides the cooling.
The foamed in place insulation and compact compressor ensure optimum
cooling.
The cooling device is portable.
When used on boats, the cooling device can withstand a constant heel
(inclination) of 30°.
5.1 Scope of functions
Three-level battery monitor to protect the vehicle battery switches off
automatically at low battery voltage
Display with temperature gauge
Temperature setting: With two buttons in steps of 1 °C (2 °F)
5.2 Operating and display elements
Latch for lid: fig. 1 1, page 3
Operating panel (fig. 2, page 3)
Item Description Explanation
1ON
OFF
Switches the cooling device on or off when the
button is pressed for between one and two seconds
FR34-FR40-FR60_MCF32-MCF40-MRF40-MCF60_OPM_EMEA16.book Seite 10 Mittwoch, 23. Dezember 2020 3:42 15
EN
MCF32, MCF40, MCF60, FR40 AC/DC Function description
11
Connectors (fig. 3, page 4)
2 POWER Status indication
LED lights up green: Compressor is on
LED lights up orange: Compressor is off
LED flashes orange: Display switched off auto-
matically due to low
battery voltage
3 ERROR LED flashes red: Cooling device is switched
on but not ready for oper-
ation
4 SET Selects the input mode
– Temperature setting
– Celsius or Fahrenheit display
– Set battery monitor
5 Display, shows the information
6 “+” Press once to increase the value
7 “–” Press once to decrease the value
8 Only MCF60: If displayed, the interior light is
switched on.
Item Description
1AC socket
2 Fuse holder
3 Cover AC socket
4 Cover DC socket
5DC socket
Item Description Explanation
FR34-FR40-FR60_MCF32-MCF40-MRF40-MCF60_OPM_EMEA16.book Seite 11 Mittwoch, 23. Dezember 2020 3:42 15
EN
Operation MCF32, MCF40, MCF60, FR40 AC/DC
12
6Operation
6.1 Before initial use
I
Selecting the temperature units
You can switch the temperature display between Celsius and Fahrenheit.
Proceed as follows:
Switch on the cooling device.
Press the “SET” button twice.
Use the “+” and “–” buttons to select Celsius or Fahrenheit.
The selected temperature units then appear in the display for a few
seconds. The display flashes several times before it returns to the current
temperature.
6.2 Saving energy
Choose a well ventilated location which is protected from direct sunlight.
Allow warm food to cool down first before placing it in the cooling device
to keep cool.
Do not open the cooling device more often than necessary.
Do not leave the cooling device open for longer than necessary.
If the cooler has a basket: For optimal energy consumption, position the
basket according to its position on delivery.
On a regularly basis, make sure the lid seal still fits properly.
6.3 Connecting the cooling device
The cooling device can be operated with DC or AC voltage.
NOTE
Before starting your new cooling device for the first time, you
should clean it inside and outside with a damp cloth for hygienic
reasons (please also refer to the chapter “Cleaning and mainte-
nance” on page 17).
FR34-FR40-FR60_MCF32-MCF40-MRF40-MCF60_OPM_EMEA16.book Seite 12 Mittwoch, 23. Dezember 2020 3:42 15
EN
MCF32, MCF40, MCF60, FR40 AC/DC Operation
13
A
For safety reasons the cooling device is equipped with an electronic system
to prevent the polarity reversal. This protects the cooling device against short-
circuiting when connecting to a battery.
Plug the DC connection cable into the DC socket and connect it to a DC
power socket.
Plug the AC connection cable into the AC voltage socket and connect it to
an AC mains.
Close the covers of the sockets not in use to prevent accidentally touching
the sockets. This also prevents dust, water and dirt from entering the
socket.
6.4 Using the battery monitor
The cooling device is equipped with a multi-level battery monitor that protects
your vehicle battery against excessive discharging when the cooling device is
connected to the DC power supply.
If the cooling device is operated when the vehicle ignition is switched off, the
cooling device switches off automatically as soon as the supply voltage falls
below a set level. The cooling device will switch back on once the vehicle
battery has been recharged to the restart voltage level.
A
NOTICE! Danger of damage!
Disconnect the cooling device and other consumer units from the
vehicle battery before you connect the vehicle battery to a quick
charging device.
Overvoltage can damage the electronics of the cooling device.
NOTICE! Danger of damage!
When switched off by the battery monitor, the vehicle battery will
no longer be fully charged. Avoid starting repeatedly or operating
current consumers without longer charging phases. Ensure that the
vehicle battery is recharged.
FR34-FR40-FR60_MCF32-MCF40-MRF40-MCF60_OPM_EMEA16.book Seite 13 Mittwoch, 23. Dezember 2020 3:42 15
EN
Operation MCF32, MCF40, MCF60, FR40 AC/DC
14
In “HIGH” mode, the battery monitor responds faster than at the levels “LOW”
and “MED” (see the following table).
Proceed as follows to select the battery monitor mode:
Switch on the cooling device.
Press the “SET” button three times.
Use the “+” and “–” buttons to select the battery monitor mode.
The selected mode then appears in the display for a few seconds. The dis-
play flashes several times before it returns to the current temperature.
I
6.5 Using the cooling device
A
Place the cooling device on a firm foundation.
I
Battery monitor mode LOW MED HIGH
Switch-off voltage at 12 V
10.1 V 11.4 V 11.8 V
Restart voltage at 12 V
11.1 V 12.2 V 12.6 V
Switch-off voltage at 24 V
21.5 V 24.1 V 24.6 V
Restart voltage at 24 V
23.0 V 25.3 V 26.2 V
NOTE
When the cooling device is supplied by the vehicle battery, select
the battery monitor mode “HIGH”. If the cooling device is con-
nected to a supply battery, the battery monitor mode “LOW” will
suffice.
NOTICE! Danger of overheating!
Ensure at all times that there is sufficient ventilation so that the heat
that generated during operation can dissipate. Ensure that the ven-
tilation slots are not covered. Make sure that the cooling device is
sufficiently far away from walls and other objects so that the air can
circulate.
NOTE
Place the cooling device as shown (fig. 1, page 3). If you operate
the cooling device in a different position it can be damaged.
FR34-FR40-FR60_MCF32-MCF40-MRF40-MCF60_OPM_EMEA16.book Seite 14 Mittwoch, 23. Dezember 2020 3:42 15
EN
MCF32, MCF40, MCF60, FR40 AC/DC Operation
15
Connect the cooling device, see chapter “Connecting the cooling device”
on page 12.
A
Press the “ON/OFF” button for between one and two seconds.
The “POWER” LED lights up.
The display switches on and shows the current cooling temperature.
I
The cooling device starts cooling the interior.
I
To avoid food waste, note the following:
Keep temperature fluctuation as low as possible. Only open the cooling
box as often and for as long as necessary. Store the foodstuff in such a way
that the air can still circulate well.
Adjust the temperature to the quantity and type of the foodstuff.
Foodstuff can easily absorb or release odor or taste. Always store food-
stuff covered or in closed containers/bottles.
6.6 Latching the cooling device lid
Lift the latch (fig. 1 1, page 3) and close the lid.
Release the latch.
The latch audibly clicks in place and secures the cooling device lid.
NOTICE! Danger from excessively low temperature!
Ensure that only those objects are placed in the cooling device
that are intended to be cooled at the selected temperature.
NOTE
The temperature displayed is that of the middle of the interior.
The temperatures elsewhere can deviate from this temperature.
NOTE
When operating with the battery, the display switches off auto-
matically if the battery voltage is low. The LED “POWER” flashes
orange.
FR34-FR40-FR60_MCF32-MCF40-MRF40-MCF60_OPM_EMEA16.book Seite 15 Mittwoch, 23. Dezember 2020 3:42 15
EN
Operation MCF32, MCF40, MCF60, FR40 AC/DC
16
6.7 Setting the temperature
Press the “SET” button once.
Use the “+” and “–” buttons to select the cooling temperature.
The cooling temperature appears in the display for a few seconds. The
display flashes several times and then the current temperature is
displayed again.
6.8 Switching off the cooling device
Empty the cooling device.
Switch the cooling device off.
Pull out the connection cable.
If you do not want to use the cooling device for a longer period of time:
Leave the lid slightly open. This prevents odour build-up.
6.9 Using the interior light (only MCF60)
Ensure the display shows the actual temperature.
Press the “–” button to switch the interior light on.
Press the “–” button again to switch the interior light off.
The black dot (fig. 2 8, page 3) in the upper left corner of the display indi-
cates whether the interior light is switched on or off.
I
6.10 Defrosting the cooling device
Humidity can form frost in the interior of the cooling device or on the evapora-
tor. This reduces the cooling capacity. Defrost the cooling device in good time
to avoid this.
A
NOTE
The interior light switches off automatically after 30 minutes.
NOTICE! Danger of damage!
Never use hard or pointed tools to remove ice or to loosen objects
which have frozen in place.
FR34-FR40-FR60_MCF32-MCF40-MRF40-MCF60_OPM_EMEA16.book Seite 16 Mittwoch, 23. Dezember 2020 3:42 15
EN
MCF32, MCF40, MCF60, FR40 AC/DC Cleaning and maintenance
17
To defrost the cooling device, proceed as follows:
Take out the contents of the cooling device.
If necessary, place them in another cooling device to keep them cool.
Switch off the cooling device.
Leave the lid open.
Wipe off the defrosted water.
6.11 Replacing the fuse
Replace the fuse (8 A 32 V) as shown (fig. 4, page 4).
7 Cleaning and maintenance
A
Occasionally clean the device interior and exterior with a damp cloth.
Make sure that the air inlet and outlet vents on the device are free of any
dust and dirt, so that heat can be released and the device is not damaged.
8 Guarantee
The statutory warranty period applies. If the product is defective, please
contact the manufacturer's branch in your country (see dometic.com/dealer) or
your retailer.
For repair and warranty processing, please include the following documents
when you send in the device:
A copy of the receipt with purchasing date
A reason for the claim or description of the fault
NOTICE! Damage hazard
Never clean the cooler under running water or in dish water.
Do not use abrasive cleaning agents or hard objects during
cleaning as these can damage the cooler.
FR34-FR40-FR60_MCF32-MCF40-MRF40-MCF60_OPM_EMEA16.book Seite 17 Mittwoch, 23. Dezember 2020 3:42 15
EN
Troubleshooting MCF32, MCF40, MCF60, FR40 AC/DC
18
9 Troubleshooting
10 Disposal
Place the packaging material in the appropriate recycling waste bins
wherever possible.
M
If you wish to finally dispose of the product, ask your local recycling
centre or specialist dealer for details about how to do this in
accordance with the applicable disposal regulations.
Fault Possible cause Suggested remedy
The cooling device
does not function,
“POWER” LED does not
glow.
There is no voltage
present in the DC power
socket in your vehicle.
The ignition must be switched on in most
vehicles to apply current to the DC power
socket.
The cooling device
does not cool (plug is
inserted, “POWER” LED
is lit).
Defective compressor. This can only be repaired by an
authorised customer services unit.
The cooling device
does not cool (plug is
inserted, “POWER” LED
flashes orange, dis-
play is switched off).
Voltage of the vehicle
battery is too low.
Test the vehicle battery and charge it as
needed.
When operating from
the DC power socket:
The ignition is on and
the cooling device is
not working and the
“POWER” LED is not lit.
The DC power socket is
dirty. This results in a
poor electrical contact.
If the plug of your cooling device
becomes very warm in the DC power
socket, either the DC power socket must
be cleaned or the plug has not been
assembled correctly.
The fuse of the DC plug
has blown.
Replace the fuse (8 A) in the DC plug, see
chapter “Replacing the fuse” on page 17.
The vehicle fuse has
blown.
Replace the vehicle’s DC power socket
fuse (usually 15 A). Please refer to your
vehicle’s operating manual.
The display shows an
error message (e.g.
“Err1”) and the cooling
device does not cool.
The cooling device has
switched off due to an
internal fault.
This can only be repaired by an
authorised repair centre.
FR34-FR40-FR60_MCF32-MCF40-MRF40-MCF60_OPM_EMEA16.book Seite 18 Mittwoch, 23. Dezember 2020 3:42 15
EN
MCF32, MCF40, MCF60, FR40 AC/DC Technical data
19
11 Technical data
I
MCF32 AC/DC
MCF40 AC/DC,
FR40 AC/DC
MCF60 AC/DC
Connection voltage: 12/24 Vg
100 – 240 Vw, 50/60 Hz
Power consumption: 4 A (12 Vg) 6 A (12 Vg)
2A (24Vg) 3 A (24 Vg)
1.0 – 0.4 A (100 – 240 Vw)
Cooling capacity: +20 °C to –10 °C
(+68 °F to +14 °F)
Total v olume : 31 l 38 l 58 l
Climate class: N
Ambient temperature: +16 °C to +32 °C
Refrigerant quantity: 40 g 42 g 58 g
CO
2
equivalent: 0.057 t 0.060 t 0.083 t
Global warming potential
(GWP):
1430
Dimensions (L x W x H): 584 x 365 x
407 mm
584 x 365 x
446 mm
680 x 440 x
470 mm
Weight: 11.4kg 11.5kg 18.4kg
Test/certificates:
NOTE
If the ambient temperature is above +32 °C (+90 °F), the minimum
temperature cannot be attained.
ID 1419063589
9
ID 1419056512
FR34-FR40-FR60_MCF32-MCF40-MRF40-MCF60_OPM_EMEA16.book Seite 19 Mittwoch, 23. Dezember 2020 3:42 15
EN
Technical data MCF32, MCF40, MCF60, FR40 AC/DC
20
The refrigerant circuit contains R134a.
Contains fluorinated greenhouse gases
Hermetically sealed equipment
FR34-FR40-FR60_MCF32-MCF40-MRF40-MCF60_OPM_EMEA16.book Seite 20 Mittwoch, 23. Dezember 2020 3:42 15
ES
Datos técnicos MCF32, MCF40, MCF60, FR40 AC/DC
70
11 Datos técnicos
I
MCF32 CA/CC
MCF40 CA/CC,
FR40 CA/CC
MCF60 CA/CC
Tensión de conexión: 12/24 Vg
100 – 240 Vw, 50/60 Hz
Consumo de corriente: 4 A (12 Vg) 6 A (12 Vg)
2A (24Vg) 3 A (24 Vg)
1,0 – 0,4 A (100 – 240 Vw)
Potencia de refrigera-
ción:
De +20 °C a -10 °C
(de +68 °F a +14 °F)
Volumen total: 31 l 38 l 58 l
Clase climática: N
Temperatura ambiente: De +16 °C a +32 °C
Cantidad de refrigerante: 40 g 42 g 58 g
Equivalente de CO
2
: 0,057 t 0,060 t 0,083 t
Índice GWP (Global war-
ming potential):
1430
Dimensiones (L x A x H): 584 x 365 x
407 mm
584 x 365 x
446 mm
680 x 440 x
470 mm
Peso: 11,4kg 11,5kg 18,4kg
Inspección/certificados:
NOTA
Si la temperatura ambiente es mayor de +32 °C (+90 °F), no se
puede alcanzar la temperatura mínima.
ID 1419063589
9
ID 1419056512
FR34-FR40-FR60_MCF32-MCF40-MRF40-MCF60_OPM_EMEA16.book Seite 70 Mittwoch, 23. Dezember 2020 3:42 15
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122
  • Page 123 123
  • Page 124 124
  • Page 125 125
  • Page 126 126
  • Page 127 127
  • Page 128 128
  • Page 129 129
  • Page 130 130
  • Page 131 131
  • Page 132 132
  • Page 133 133
  • Page 134 134
  • Page 135 135
  • Page 136 136
  • Page 137 137
  • Page 138 138
  • Page 139 139
  • Page 140 140
  • Page 141 141
  • Page 142 142
  • Page 143 143
  • Page 144 144
  • Page 145 145
  • Page 146 146
  • Page 147 147
  • Page 148 148
  • Page 149 149
  • Page 150 150
  • Page 151 151
  • Page 152 152
  • Page 153 153
  • Page 154 154
  • Page 155 155
  • Page 156 156
  • Page 157 157
  • Page 158 158
  • Page 159 159
  • Page 160 160
  • Page 161 161
  • Page 162 162
  • Page 163 163
  • Page 164 164
  • Page 165 165
  • Page 166 166
  • Page 167 167
  • Page 168 168
  • Page 169 169
  • Page 170 170
  • Page 171 171
  • Page 172 172
  • Page 173 173
  • Page 174 174
  • Page 175 175
  • Page 176 176
  • Page 177 177
  • Page 178 178
  • Page 179 179
  • Page 180 180
  • Page 181 181
  • Page 182 182
  • Page 183 183
  • Page 184 184
  • Page 185 185
  • Page 186 186
  • Page 187 187
  • Page 188 188
  • Page 189 189
  • Page 190 190
  • Page 191 191
  • Page 192 192
  • Page 193 193
  • Page 194 194
  • Page 195 195
  • Page 196 196
  • Page 197 197
  • Page 198 198
  • Page 199 199
  • Page 200 200
  • Page 201 201
  • Page 202 202
  • Page 203 203
  • Page 204 204
  • Page 205 205
  • Page 206 206
  • Page 207 207
  • Page 208 208
  • Page 209 209
  • Page 210 210
  • Page 211 211
  • Page 212 212
  • Page 213 213
  • Page 214 214
  • Page 215 215
  • Page 216 216
  • Page 217 217
  • Page 218 218
  • Page 219 219
  • Page 220 220
  • Page 221 221
  • Page 222 222
  • Page 223 223
  • Page 224 224
  • Page 225 225
  • Page 226 226
  • Page 227 227
  • Page 228 228
  • Page 229 229
  • Page 230 230
  • Page 231 231
  • Page 232 232
  • Page 233 233
  • Page 234 234
  • Page 235 235
  • Page 236 236
  • Page 237 237
  • Page 238 238
  • Page 239 239
  • Page 240 240
  • Page 241 241
  • Page 242 242
  • Page 243 243
  • Page 244 244
  • Page 245 245
  • Page 246 246
  • Page 247 247
  • Page 248 248
  • Page 249 249
  • Page 250 250
  • Page 251 251
  • Page 252 252
  • Page 253 253
  • Page 254 254
  • Page 255 255
  • Page 256 256
  • Page 257 257
  • Page 258 258
  • Page 259 259
  • Page 260 260
  • Page 261 261
  • Page 262 262
  • Page 263 263
  • Page 264 264
  • Page 265 265
  • Page 266 266
  • Page 267 267
  • Page 268 268

Mobicool COOL BOXES – Mobile Refrigerating Appliance User manual

Category
Cool boxes
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI