Marantec FTU Owner's manual

Type
Owner's manual
EN
Chain drives for industrial Fire doors FTU / Rev. C 0.1 – 1
Chain drives for industrial Fire doors
FTU
Installation and operating instructions
Last updated: 08.2023
EN
2 – Chain drives for industrial Fire doors FTU / Rev. C 0.1
1. Contents
1. Contents. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2. Information in this document . . . . . . . . . . . . .2
3. General safety instructions . . . . . . . . . . . . . . .3
4. Product overview. . . . . . . . . . . . . . . . . . . . . . .4
4.1 Product description...................4
4.2 Versions ...........................4
4.3 Limit position system .................4
4.4 Tensioning brackets ..................4
5. Mechanical installation . . . . . . . . . . . . . . . . . .5
5.1 Safety instructions for mechanical installation 5
5.2 Mounting the tensioning bracket.........5
5.3 Mounting the drive ...................5
5.4 Installing the fall protection device .......7
6. Electrical installation . . . . . . . . . . . . . . . . . . . .8
6.1 Safety instructions for electrical installation . 8
6.2 Wiring harness .....................8
6.3 Motor winding ......................8
6.4 Motor cable wire assignment ...........9
6.5 Wire assignment of cables for mechanical
limit switches MEC ..................9
6.6 Wire assignment of cables for absolute
value encoder (optional) ..............10
6.7 Door control .......................10
6.8 Connection to the CS320 .............10
6.9 Design of CS320 FTU ................13
6.10 Connection to the CS320 FTU..........14
7. Limit position setting. . . . . . . . . . . . . . . . . . .15
7.1 Mechanical limit switches KM50 ........15
7.2 Absolute value encoder...............15
8. Start-up . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
9. Maintenance / testing . . . . . . . . . . . . . . . . . .17
10. Technical data . . . . . . . . . . . . . . . . . . . . . . . .18
11. Declaration of incorporation (EU) . . . . . . . . .21
12. Declaration of incorporation (UK) . . . . . . . . .22
Original assembly instructions
Copyright.
No part of these instructions may be reproduced without
our prior approval.
Subject to alterations in the interest of technical progress.
All dimensions given in mm.
The diagrams in this manual are not to scale.
Key to symbols
WARNING!
Indicates a hazard with a medium level of risk which, if not
avoided, could result in death or serious injury.
CAUTION!
Indicates a hazard with a low level of risk which, if not
avoided, could result in minor or moderate injury.
ATTENTION!
Indicates an imminent danger of damage or destruction.
CHECK
Indicates a check to be performed.
REFERENCE
Reference to separate documents which must be complied
with.
Action requestAction request
List, itemisation
ÔReference to other sections of this document
2. Information in this document
EN
Chain drives for industrial Fire doors FTU / Rev. C 0.1 – 3
3. General safety instructions
WARNING!
Failure to comply with the documentation could
result in life-threatening danger!
Be sure to follow all the safety instructions in this docu-
Be sure to follow all the safety instructions in this docu-
ment.
ment.
Warranty
The function and safety of the equipment is only guaranteed
if the warning and safety instructions included in these
assembly instructions are adhered to.
The manufacturer is not liable for personal injury or damage
to property if these occur as a result of the warnings and
safety advice being disregarded.
The manufacturer does not accept any liability or warranty
for damage due to the use of non-approved spare parts and
accessories.
Intended use
The drives in the FTU series are suitable exclusively for
opening and closing re-resistant roller doors without spring
or weight compensation. The force transfer to the door takes
place via a chain drive.
In the case of doors that must be secured against falling, a
separate safety catch device is required.
Target group
Only qualied and trained specialist tters are permitted to
install the drive and perform mechanical maintenance.
Qualied and trained specialist tters must satisfy the
following requirements:
Knowledge of the general and specic safety and accident
prevention regulations,
Knowledge of the relevant regulations,
Training in the use and care of appropriate safety
equipment,
Capable of recognising the dangers associated with
assembly.
Only qualied and trained electricians are permitted to
connect the drive and perform the electrical maintenance.
Qualied and trained electricians must satisfy the following
requirements:
Knowledge of the general and specic safety and accident
prevention regulations,
Knowledge of the relevant electrical regulations,
Training in the use and care of appropriate safety
equipment,
Capable of recognising the dangers associated with
electricity.
Instructions regarding installation, connection and
testing
The system must be disconnected from the electricity supply
before carrying out any electrical work. It must be ensured
that the electricity supply remains disconnected for the
duration of the work.
It is essential to observe the local protective regulations.
Observe the valid standards and regulations.
Information concerning operation
If oil or emulsion mist is to be expected in the direct vicinity
of the drive, which can inuence the friction coefcient of
the brake, protection class IP65 must be selected.
Unauthorised persons (particularly children) should not be
allowed to play with permanently installed adjusting or
control devices.
Keep remote controls beyond the reach of children.
4 – Chain drives for industrial Fire doors FTU / Rev. C 0.1
4. Product overview
4.1 4.1 Product descriptionProduct description
The drives in the FTU series are specially designed for re-
resistant doors without spring or weight compensation. They
form a model series from 250–1050Nm. They are connected
with the door shaft by a roller chain. In case of re, they close
independently and automatically by means of gravity alone,
without an energy supply.
In normal operation, the door is opened and closed again
through power operation by a three-phase motor. The gearing
consists of a non-self-locking spur gear unit, a centrifugal and
magnetic brake, an electric motor and an end position system.
The drives are not equipped with manual emergency
operation.
The door load is held by a magnetic brake that is released
immediately in case of re. The centrifugal brake ensures that
the door speed is limited.
In the case of doors that must be secured against falling, a
separate fall protection device is required.
4.2 4.2 VersionsVersions
The following versions of the FTU drive are available for
delivery:
FTU 05-25-20
FTU 3-50-20
FTU 4-70-20
FTU 5-105-20
B
C
A
4.2 / 1
A Spur gear with centrifugal brake
B Electric motor with magnetic brake
C Limit position system
The precise technical specications of all drives are listed in
the technical data.
Ô“10. Technical data”
Further product combinations are possible.
Information on this is available from the manufacturer.
4.3 4.3 Limit position systemLimit position system
Two systems can be selected for the limit position setting:
Mechanical limit switches MEC (A).
Electronic absolute value encoder AWG (B).
A
4.3 / 1
B
4.4 4.4 Tensioning bracketsTensioning brackets
A special base means mounting the FTU drives is extremely
safe. These tensioning brackets, type MK-FT, enable tensioning
or re-tensioning of the chain drive at any time.
The list of available brackets and assignment to the individual
drive types can be found in the technical data.
Ô“10. Technical data”
4.4 / 1
EN
Chain drives for industrial Fire doors FTU / Rev. C 0.1 – 5
5. Mechanical installation
5.1 5.1 Safety instructions for mechanical Safety instructions for mechanical
installationinstallation
WARNING!
Serious injuries possible due to incorrect installati-
on of the drive!
All components for fastening, connection and the trans-
fer of force must be designed for the maximum loads
that can occur.
The installation base (wall, pillar, etc.) must be suitable
for the maximum loads that can arise.
Installation must take place whilst standing on a stable
foundation
(e. g. scaffolding).
ATTENTION!
Property damage due to improper installation of
the drive!
To avoid damage to the drive and door, only install the
drive if
a special bracket for fastening the drive permits
tensioning or re-tensioning of the chain drive at any time,
the drive is undamaged and not blocked,
it has been checked after an extended time in storage
that the drive runs smoothly and does not exhibit any
corrosion,
the ambient temperature is -20 ºC to +60ºC,
the installation altitude does not exceed 1,000 m above
sea level,
the correct protection type has been selected,
no other danger sources are present,
the installation location is widely cordoned off.
REFERENCE
When installing the drive on the door system, observe the
corresponding installation and operating manual from the
door manufacturer.
5.2 5.2 Mounting the tensioning bracketMounting the tensioning bracket
5.2 / 1
Specify the installation location of the tensioning bracket.Specify the installation location of the tensioning bracket.
Mount the tensioning bracket next to the roller door bracket.Mount the tensioning bracket next to the roller door bracket.
5.3 5.3 Mounting the driveMounting the drive
5.3 / 1
Mount the drive on the tensioning bracket.Mount the drive on the tensioning bracket.
Only tighten the screws lightly.Only tighten the screws lightly.
6 – Chain drives for industrial Fire doors FTU / Rev. C 0.1
5.3 / 4
Make sure the sprocket is slid correctly onto the drive shaft.Make sure the sprocket is slid correctly onto the drive shaft.
5.3 / 2
Bring the sprocket into position.Bring the sprocket into position.
Mount the chain.Mount the chain.
To guarantee correct function, it is essential to observe the
following specications (“5.3 / 3”“5.3 / 5”).
5.3 / 3
Make sure the sprockets of the door shaft and drive shaft Make sure the sprockets of the door shaft and drive shaft
are ush with each other.are ush with each other.
Mechanical installation
EN
Chain drives for industrial Fire doors FTU / Rev. C 0.1 – 7
s
5.3 / 5
Make sure that the chain tension specications are observed Make sure that the chain tension specications are observed
(see = width of chain link).(see = width of chain link).
5.3 / 6
Tension the chain.Tension the chain.
Tighten the connection screws for the tensioning bracket.Tighten the connection screws for the tensioning bracket.
5.4 5.4 Installing the fall protection deviceInstalling the fall protection device
A roller chain is used for the transfer of force. Safe operation
of the roller/door system is therefore only possible in
connection with a fall protection device (e.g. external safety
catch device).
Fall protection must be additionally equipped with an electri-
cal disconnect device in the following case:
The door drive is able to move the door leaf by motor
power after it has been stopped by the fall protection.
5.4 / 1
A
B
A External safety catch device
(e.g. TS series, Marantec Legden drives)
B Electrical disconnect device
8 – Chain drives for industrial Fire doors FTU / Rev. C 0.1
6. Electrical installation
6.1 6.1 Safety instructions for electrical Safety instructions for electrical
installationinstallation
WARNING!
Life-threatening danger due to electric shock!
Before performing wiring work, always disconnect the
Before performing wiring work, always disconnect the
drive system from the power supply. Make sure that the
drive system from the power supply. Make sure that the
power supply remains disconnected during wiring work.
power supply remains disconnected during wiring work.
ATTENTION!
Property damage due to improper installation of
the drive!
In order to avoid damage to the drive, observe the
following points:
Mains cables and control cables must be routed
separately.
The line types and cross-sections must be selected in
accordance with the valid specications.
It is essential to observe the local protective regulations.
Observe the specications of the door manufacturer for
assembly.
The mains voltage must correspond with the information
on the type plate for the drive and the wiring on the
motor terminal board.
In the case of three-phase power, this must have a
clockwise rotating eld.
With a xed connection, an all-pole main switch must be
used.
With three-phase power, only triple block circuit breakers
(10A) shall be used.
Observe the valid standards and regulations!
REFERENCE
In case of operation with a door control (e.g. CS320,
CS320FTU) consider the corresponding assembly manuals.
6.2 6.2 Wiring harness Wiring harness
Drives from the FTU series are pre-wired with a wiring
harness in the factory. The wiring harness consists of 2 cables
and the length is selectable.
B
A
6.2 / 1
A Cable for limit position system MEC / absolute value
encoder
B Motor cable
6.3 6.3 Motor windingMotor winding
The motor is pre-wired for connection to a 400V / 3~ in
star connection. The motor can be converted at the motor
terminal board for operation on 230V / 3~ (delta connection)
if necessary.
6.3 / 1
Δ 230V/3~Y 400V/3~
EN
Chain drives for industrial Fire doors FTU / Rev. C 0.1 – 9
6.5 6.5 Wire assignment of cables for mechanical Wire assignment of cables for mechanical
limit switches MEC limit switches MEC
The mechanical limit switches are designed as changeover
contacts and are equipped with 3 plug-in connections.
6.5 / 1 COM
NO NC
NOTE:
The mechanical limit switches are always wired as an
NC contact, although they can also be used as an
NO contact if necessary.
Wire assignment
A
B
C
D
E
6.5 / 2
7
6
5
4
8
9
10
11
A Switch cam limit switch OPEN (green)
B Switch cam safety limit switch OPEN (red)
C Switch cam safety limit switch CLOSE (red)
D Switch cam limit switch CLOSE (white)
E Switch cam supplementary limit switch CLOSE (white)
6.4 6.4 Motor cable wire assignment Motor cable wire assignment
q
W2 U2 V2
U1 V1 W1
1 2 3 4 5 6 7 PE
B
A
6.4 / 1
C
D
A Motor terminal board
B Thermal protection
C Motor brake (103V=)
D Brake rectier (230V~/103V=)
10 – Chain drives for industrial Fire doors FTU / Rev. C 0.1
6.6 6.6 Wire assignment of cables for absolute Wire assignment of cables for absolute
value encoder (optional)value encoder (optional)
The absolute value encoder (AWG) as an electronic limit
position system is equipped with a 6-pole plug for connecting
to the door control and a plug-in terminal for the optional
connection of safety elements.
6.6 / 1
A
B
C
A Absolute value encoder plug
B Absolute value encoder plug-in terminals
C Jumper (use is essential)
Absolute value encoder plug wire assignment
6.6 / 2
Cables with either numbered or coloured wires are used for
the absolute value encoder, depending on the drive.
4 (grey) Safety circuit input
5 (green) Communication RS 485 B
6 (white) GND
7 (yellow) Communication RS 485 A
8 (pink) Safety circuit output
9 (brown) 12 V-DC
6.7 6.7 Door controlDoor control
The FTU drive series is designed for operation with the CS320
and CS320 FTU door controls from Marantec Legden.
REFERENCE
The assembly manual for the CS 320 control must be
observed.
6.8 6.8 Connection to the CS320Connection to the CS320
The CS320 operates in normal mode as a door control
with active safety equipment. In case of re, automatic
(emergency) closing is implemented by the re alarm system
with active closing edge protection.
In case of a power failure, the door closes by releasing the
magnetic brake, without active closing edge protection.
Electrical installation
EN
Chain drives for industrial Fire doors FTU / Rev. C 0.1 – 11
Version 1: Mechanical limit switches (standard)
6.8 / 1
A
B
A Cable for mechanical limit switches MEC
B Motor cable
Connect the motor cable with the CS320 door control.Connect the motor cable with the CS320 door control.
Ô“6.8 / 1”
Connect terminal L/X19 with terminal 7/X5.Connect terminal L/X19 with terminal 7/X5.
Connect the cable of the mechanical limit switches with the CS320 door control.Connect the cable of the mechanical limit switches with the CS320 door control.
Ô“6.8 / 1”
Set the parameter RELAY 4 in the input menu of the control to MOD 15.Set the parameter RELAY 4 in the input menu of the control to MOD 15.
Connection of the re alarm system
The connection of the re alarm system to the CS320 control takes place via the programmable input 1 (X4/9-10).
Setting the input for the emergency closing is dependent on the output contact of the re alarm system (NO or NC).
REFERENCE
For further information refer to the assembly manual for the CS320.
12 – Chain drives for industrial Fire doors FTU / Rev. C 0.1
Version 2: Absolute value encoder (optional)
6.8 / 2
C
B
B Motor cable
C Cable for absolute value encoder
Connect the motor cable with the CS320 door control.Connect the motor cable with the CS320 door control.
Ô“6.8 / 2”
Connect terminal L/X19 with terminal 7/X5.Connect terminal L/X19 with terminal 7/X5.
Connect the cable of the absolute value encoder with the CS320 door control (plug-in connection to X11).Connect the cable of the absolute value encoder with the CS320 door control (plug-in connection to X11).
Ô“6.8 / 2”
Set the parameter RELAY 4 in the input menu of the control to MOD 15.Set the parameter RELAY 4 in the input menu of the control to MOD 15.
Connection of the re alarm system
The connection of the re alarm system to the CS320 control takes place via the programmable input 1 (X4/9-10).
Setting the input for the emergency closing is dependent on the output contact of the re alarm system (NO or NC).
REFERENCE
For further information refer to the operating manual for the CS320.
Electrical installation
EN
Chain drives for industrial Fire doors FTU / Rev. C 0.1 – 13
6.9 6.9 Design of CS320 FTUDesign of CS320 FTU
The CS320 FTU is installed in the combination housing and is
equipped with
one additional power unit,
two external relays for brake actuation and
one separate connection terminal for accommodating
the FTU motor cable,
the UPS connection cable and the
connection cable for the re alarm system.
A
6.9 / 1
A CS320 circuit board
K1 Relay for brake actuation
K2 Relay for brake actuation
T1 Power unit
X01 UPS connection
X02 Fire alarm system connection (NC)
X03 Motor cable FTU connection
X11 Absolute value encoder connection
X15 Mechanical limit switch connection
Equipped with an additional power supply (UPS) for the
magnetic brake, the CS320 FTU operates in normal mode as a
door control with active safety devices.
In the event of a power failure, the magnetic brake continues
to be supplied via the UPS system and the door remains open.
In case of re, automatic (emergency) closing is implemented
by the re alarm system, independent of the mains power
supply.
The control and UPS are connected with each other in
accordance with the plug & play principle.
A
6.9 / 2
D
F
C
E
B
A CS320 FTU control
B FTU drive
C UPS
D CS320 FTU power supply (400/230/3~)
E UPS power supply (230V/1~)
F Fire alarm system connection (NC)
14 – Chain drives for industrial Fire doors FTU / Rev. C 0.1
6.10 6.10 Connection to the CS320 FTUConnection to the CS320 FTU
Version 1: Mechanical limit switches (standard)
A
6.10 / 1
B
A Cable for mechanical limit switches MEC
B Motor cable
Connect the motor cable with the CS320FTU door control.Connect the motor cable with the CS320FTU door control.
Ô“6.10 / 1”
Connect the cable of the mechanical limit switches with the Connect the cable of the mechanical limit switches with the
CS320 FTU door control.CS320 FTU door control.
Ô“6.10 / 1”
Make sure the parameter RELAY 4 in the input menu of the Make sure the parameter RELAY 4 in the input menu of the
control has been set to MOD 14.control has been set to MOD 14.
Version 2: Absolute value encoder (optional)
C
6.10 / 2
B
B Motor cable
C Cable for absolute value encoder
Connect the motor cable with the CS320FTU door control.Connect the motor cable with the CS320FTU door control.
Ô“6.10 / 2”
Connect the cable of the absolute value encoder with the Connect the cable of the absolute value encoder with the
CS320 FTU door control (plug-in connection to X11).CS320 FTU door control (plug-in connection to X11).
Ô“6.10 / 2”
Make sure the parameter RELAY 4 in the input menu of the Make sure the parameter RELAY 4 in the input menu of the
control has been set to MOD 14.control has been set to MOD 14.
Connection of the re alarm system
The connection for the emergency closing by the re alarm
system is established at terminal X02/1-2 of the CS320FTU
control.
Ô“6.9 / 1”
The re alarm system output must be designed as an NC
contact.
REFERENCE
For further information please refer to the operating manual
for the CS320 and the UPS.
Electrical installation
EN
Chain drives for industrial Fire doors FTU / Rev. C 0.1 – 15
7. Limit position setting
7.1 7.1 Mechanical limit switches KM50Mechanical limit switches KM50
With drives with mechanical limit switch cams, it is necessary
to set the limit positions manually.
7.1 / 1
DCBA
E
A Switch cam limit switch OPEN (green)
B Switch cam safety limit switch OPEN (red)
C Switch cam safety limit switch CLOSE (red)
D Switch cam limit switch CLOSE (white)
E Switch cam supplementary limit switch CLOSE (white)
Each switch cam is equipped with a set screw (F) and a ne
adjustment screw (G).
7.1 / 2
F
G
Using the set screw (F), the corresponding switch cam is held
in the desired position.
A more precise setting can be realised with the ne adjust-
ment screw (G).
Setting the CLOSE limit position
Drive the door into the limit position CLOSE.Drive the door into the limit position CLOSE.
Set the switch cam such that the limit switch CLOSE (D) is Set the switch cam such that the limit switch CLOSE (D) is
actuated.actuated.
Tighten the set screw (F).Tighten the set screw (F).
The safety limit switch CLOSE (C) must be set such that it
switches immediately if the limit switch CLOSE (D) is overrun.
Set the safety limit switch CLOSE (D).Set the safety limit switch CLOSE (D).
Setting the OPEN limit position
Drive the door into the limit position OPEN.Drive the door into the limit position OPEN.
Set the switch cam such that the limit switch OPEN (A) is Set the switch cam such that the limit switch OPEN (A) is
actuated.actuated.
Tighten the set screw (F).Tighten the set screw (F).
The safety limit switch OPEN (B) must be set such that it swit-
ches immediately if the limit switch OPEN (A) is overrun.
Set the safety limit switch OPEN (B).Set the safety limit switch OPEN (B).
The setting is implemented using a 2.5 mm hexagon socket
wrench.
7.2 7.2 Absolute value encoderAbsolute value encoder
REFERENCE
For drives with an electronic limit position system (H) the
limit position setting is described in the operation manual of
the control.
7.2 / 1
H
16 – Chain drives for industrial Fire doors FTU / Rev. C 0.1
8. Start-up
After completion of assembly and installation, all drive
components must be checked for mechanical strength and
function.
Checking the mechanical components
Check that all components for fastening, connection and Check that all components for fastening, connection and
power transmission are tight and in perfect condition.power transmission are tight and in perfect condition.
Check whether the gear unit is losing oil.Check whether the gear unit is losing oil.
Permanently protect the output shaft from corrosion.Permanently protect the output shaft from corrosion.
ATTENTION!
Property damage due to improper start-up of the
drive!
If the drive makes unusual noises or loses oil, it is necessary
to put the drive out of operation immediately and inform
customer service.
Checking the electrical components
Check all lines for damage.Check all lines for damage.
Check all screw and plug-in connections and cable glands Check all screw and plug-in connections and cable glands
for tightness.for tightness.
Check whether all motor protection devices are active.Check whether all motor protection devices are active.
Checking the brake
Check the brake function.Check the brake function.
Check the run-on path of the door.Check the run-on path of the door.
Check the mechanical venting of the brake Check the mechanical venting of the brake ONLYONLY with a with a
completely closed door.completely closed door.
Checking the running direction
Check the running direction according to the button com-Check the running direction according to the button com-
mand (OPEN / CLOSE). mand (OPEN / CLOSE).
If the running direction of the door does not comply with If the running direction of the door does not comply with
the button commands, the direction of rotation must be the button commands, the direction of rotation must be
changed.changed.
REFERENCE
In order to change the direction of rotation, refer to the
operating manual for the control.
After changing the direction of rotation, check the running After changing the direction of rotation, check the running
direction again.direction again.
Checking the limit switch positions
Drive the door into both limit positions. Drive the door into both limit positions.
The door must stop at the desired positions. The door must stop at the desired positions.
Only MEC:
The safety limit switches must not be actuated.
Check the seating of the fastening screws.Check the seating of the fastening screws.
EN
Chain drives for industrial Fire doors FTU / Rev. C 0.1 – 17
9. Maintenance / testing
WARNING!
Life-threatening danger due to electric shock!
Before performing wiring work, always disconnect the
Before performing wiring work, always disconnect the
drive system from the power supply. Make sure that the
drive system from the power supply. Make sure that the
power supply remains disconnected during wiring work.
power supply remains disconnected during wiring work.
The drives of the FTU series are maintenance-free.
However, the drive must be checked by a qualied and trained
specialist at least once a year.
With a greater number of cycles the check must take place
more frequently.
The brake is subject to wear and must be checked regularly
and tested for functionality.
The hollow shaft must be kept free of rust.
ATTENTION!
Property damage due to improper testing of the
drive!
In order to avoid damage to the drive and door, observe the
following points:
Testing must only be carried out by authorised persons.
Worn or faulty parts must be replaced.
Only approved original parts may be installed.
The test results must be documented in the log book for
the door system.
Check that all components for fastening, connection and Check that all components for fastening, connection and
power transmission are tight and in perfect condition.power transmission are tight and in perfect condition.
Check for corrosion, noise and oil loss.Check for corrosion, noise and oil loss.
Permanently protect the output shaft from corrosionPermanently protect the output shaft from corrosion
Check the brake function and run-on path of the door.Check the brake function and run-on path of the door.
Check the mechanical venting of the brake Check the mechanical venting of the brake
((ONLYONLY with a completely closed door). with a completely closed door).
Check the limit switches and safety switches.Check the limit switches and safety switches.
Check all electrical cables and the housing for damage. A Check all electrical cables and the housing for damage. A
defective cable must be replaced immediately.defective cable must be replaced immediately.
Replaced faulty parts must be disposed of properly in accor-
dance with the materials they contain and local regulations.
In case of malfunctions, please contact the manufacturer.
18 – Chain drives for industrial Fire doors FTU / Rev. C 0.1
FTU 05-25-20 FTU 3-50-20 FTU 4-70-20 FTU 5-105-20
Output torque Nm 250 500 700 1050
Output speed min -1 20 20 20 20
Reverse torque Nm 7 27 27 27
Motor power kw 0.55 1.1 1.5 2.2
Operating voltage V 230 / 400 / 3~ 230 / 400 / 3~ 230 / 400 / 3~ 230 / 400 / 3~
Mains frequency Hz 50 50 50 50
Control voltage V 24 24 24 24
Motor nominal current A 2.8 / 1.3 5.4 / 3.1 6.6 / 3.8 9.2 / 5.3
Max. cycles per hour * 30 30 30 30
Customer-provided fuse A 10 10 10 10
Protection grade IP 54 54 54 54
Temperature range** °C -20 / +60 -20 / +60 -20 / +60 -20 / +60
Continuous sound pressure level dB (A) < 70 < 70 < 70 < 70
Unit weight kg 40 59 68 94
Maximum output revolutions 48 48 48 48
Ø - plug pins (standard) mm 25 40 40 40
Tensioning bracket MK2-FT 05 MK2-FT 2-4 MK2-FT 2-4 MK7-FT 5
Unit weight kg 10.8 11.9 11.9 19.5
* One cycle equates to two travels of the door (opening and closing).
The cited values pertain to 10 revolutions of the output shaft per travel and assume equal distribution.
** Temperature ranges < -20°C : Oil type and electric heating on inquiry
10. Technical data
EN
FTU 3-50-20
10 / 2
FTU 05-25-20
9
160
150
125
9045
110
13015
30
15
90
11.5
10
DIN 6885-A 8x7x27
25
322
150
138
520
218
10 / 1
FTU 4-70-20
10 / 3
FTU 5-105-20
DIN 6885 -A- 14x9x80
205
245
20
25
140
Ø40
59
Ø17.5
405
867
391
170
230
250
10 / 4
Technical data
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24